02.08.2013 Views

M12 Oncore Users Guide Supplement - deetc - isel

M12 Oncore Users Guide Supplement - deetc - isel

M12 Oncore Users Guide Supplement - deetc - isel

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Motorola GPS Products<br />

<strong>M12</strong> <strong>Oncore</strong> User’s <strong>Guide</strong> <strong>Supplement</strong><br />

Revision 1.0 01/25/00<br />

GPZDA (TIME AND DATE)<br />

This command enables the GPZDA Time and Date message and determines the rate<br />

at which the information is transmitted. The periodic rate field (yyyy) instructs the<br />

receiver either to output this message once (polled), or to output this message at the<br />

indicated update rate (continuously). Once the receiver is set to continuous output,<br />

the continuous flow can be stopped by sending a one-time (polled) output request.<br />

The receiver will output the response one final time, and then terminate any further<br />

message outputs.<br />

Currently, there is no mechanism to set the local zone description in the NMEA I/O<br />

format, and the receiver operates as if the GMT offset is set to 00:00.<br />

Default mode: Disabled<br />

106

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!