VisionPRO TM <strong>8000</strong> <strong>Touchscreen</strong> <strong>Programmable</strong> <strong>Thermostat</strong><br />

OUTDOOR/INDOOR<br />

TEMPERATURE<br />

SENSOR<br />

1<br />

2<br />

3<br />

3<br />

Y2 RC<br />

R<br />

W<br />

W2 Y<br />

S1 G<br />

S2 C<br />

FAN<br />

RELAY<br />

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD<br />

PROTECTION AS REQUIRED.<br />

FACTORY INSTALLED JUMPER.<br />

CONVENTIONAL<br />

2<br />

COMPRESSOR<br />

CONTACTOR<br />

OPTIONAL<br />

24 VAC<br />

COMMON<br />

CONNECTION<br />

OPTIONAL OUTDOOR OR INDOOR REMOTE SENSOR. AVAILABLE<br />

ON SELECT MODELS. WIRES MUST HAVE A CABLE SEPARATE<br />

FROM THE THERMOSTAT CABLE.<br />

M19900<br />

Fig. 15. Typical hookup of cool only system<br />

(1C conventional).<br />

OUTDOOR/INDOOR<br />

TEMPERATURE<br />

SENSOR<br />

1<br />

2<br />

3<br />

3<br />

HEAT RELAY 2<br />

Y2 RC<br />

R<br />

W<br />

2<br />

W2 Y<br />

S1 G<br />

S2 C<br />

COOL RELAY 2<br />

FAN<br />

RELAY<br />

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD<br />

PROTECTION AS REQUIRED.<br />

FACTORY INSTALLED JUMPER.<br />

CONVENTIONAL<br />

HEAT RELAY 1<br />

OPTIONAL<br />

24 VAC<br />

COMMON<br />

CONNECTION<br />

MUST COME<br />

FROM THE<br />

COOLING<br />

TRANSFORMER.<br />

COOL RELAY 1<br />

Fig. 16. Typical hookup of conventional multistage<br />

two-stage heating and two-stage cooling in a<br />

single-transformer system<br />

(2H/2C, 2H/1C or 1H/2C conventional).<br />

68-0280 8<br />

1<br />

R<br />

OPTIONAL OUTDOOR OR INDOOR REMOTE SENSOR. AVAILABLE<br />

ON SELECT MODELS. WIRES MUST HAVE A CABLE SEPARATE<br />

FROM THE THERMOSTAT CABLE.<br />

M22438B<br />

C<br />

1<br />

R<br />

C<br />

OUTDOOR/INDOOR<br />

TEMPERATURE<br />

SENSOR<br />

1<br />

2<br />

3<br />

HEAT RELAY 2<br />

Y2 RC<br />

R<br />

W<br />

W2 Y<br />

S1 G<br />

S2 C<br />

FAN<br />

RELAY<br />

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD<br />

PROTECTION AS REQUIRED.<br />

FACTORY INSTALLED JUMPER.<br />

CONVENTIONAL<br />

2<br />

COOL RELAY 2<br />

HEAT RELAY 1<br />

OPTIONAL<br />

24 VAC<br />

COMMON<br />

CONNECTION<br />

MUST COME<br />

FROM THE<br />

COOLING<br />

TRANSFORMER.<br />

COOL RELAY 1<br />

Fig. 17. Typical hookup of conventional multistage<br />

two-stage heating and two-stage cooling in a<br />

two-transformer system (2H/2C, 2H/1C or<br />

1H/2C conventional).<br />

1<br />

R<br />

3 OPTIONAL OUTDOOR OR INDOOR REMOTE SENSOR. AVAILABLE<br />

ON SELECT MODELS. WIRES MUST HAVE A CABLE SEPARATE<br />

FROM THE THERMOSTAT CABLE.<br />

M19902B<br />

C<br />

1<br />

R<br />

C