GHO-Tron 5 R RUS
GHO-Tron 5 R RUS
GHO-Tron 5 R RUS
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
10/16<br />
25<br />
420010264101 <strong>GHO</strong> - TRON 5.5000 / 5.5800 R<br />
Connection examples with vent pipe to atmosphere using burner controls type LGB2..., LGB3... or LGB4...<br />
For other connections, refer to the connection diagram of the relevant burner control.<br />
H<br />
L<br />
N<br />
Valve proving test prior to burner startup Valve proving test following immediately the controlled<br />
shutdown<br />
LGB2.../3.../4.../LMG2...<br />
12<br />
SB / R / W<br />
1 3 6<br />
12 14 19 20 22<br />
hr2<br />
21 24<br />
ar2 III<br />
17 15<br />
XI<br />
hr1<br />
N<br />
2 4 5<br />
DW<br />
16<br />
GP<br />
11 23 LDU11 13<br />
C<br />
3 4<br />
M<br />
B<br />
A1<br />
E<br />
5<br />
A2<br />
7696a05/0403<br />
10<br />
AL<br />
Plants with vent pipe to atmosphere<br />
E<br />
GP<br />
B<br />
C<br />
LDU<br />
DW<br />
A<br />
Building Technologies CC1N7696en<br />
HVAC Products 25.04.2005<br />
L<br />
N<br />
LGB2.../3.../4.../LMG2...<br />
H<br />
14 15<br />
7696s01/0695<br />
16<br />
2<br />
DW<br />
17 3<br />
ar2<br />
4<br />
C<br />
SB / R / W<br />
P<br />
1<br />
12<br />
6<br />
III<br />
5<br />
GP<br />
3<br />
M<br />
I<br />
7<br />
E<br />
5<br />
A2 A1<br />
8 12<br />
XI<br />
11<br />
B<br />
³) Only in connection with LMG2...<br />
E<br />
GP<br />
B<br />
C<br />
LDU<br />
DW<br />
A1<br />
A2<br />
19 23 20 22 21 24<br />
hr2<br />
Connection examples with vent pipe to atmosphere using burner controls type LFE..., LFL... or LGK..., or the<br />
control unit LEC...<br />
Valve proving test during the prepurge time (min. 60 seconds)<br />
and following immediately the controlled shutdown<br />
in plants with vent pipe to atmosphere.<br />
Delay on make of relay d > 2 seconds.<br />
2) Expanding flame burner or interrupted pilot burner<br />
LFE1<br />
LEC1<br />
LFL1...<br />
LGK16...<br />
EK2<br />
DW<br />
16<br />
18 1<br />
ar2<br />
3 4<br />
17<br />
15 14 2<br />
N<br />
W<br />
R<br />
d<br />
2<br />
8<br />
4<br />
9<br />
5<br />
5<br />
GP C<br />
18 19 4 5°/10°°<br />
12 1314<br />
LP<br />
6<br />
III<br />
E<br />
8<br />
I<br />
7<br />
A<br />
N<br />
10<br />
V<br />
9<br />
18°/17°°<br />
12 19 23 20 22 21 24<br />
hr2<br />
XI hr1 N<br />
11 LDU11 13<br />
B<br />
2)<br />
2)<br />
7696a10/0401<br />
AL<br />
hr1<br />
LDU11<br />
Valve proving test following immediately the controlled<br />
shutdown<br />
2) Expanding flame burner or interrupted pilot burner<br />
LFE1<br />
LEC1<br />
LFL1...<br />
LGK16...<br />
N<br />
EK2<br />
DW<br />
16<br />
17<br />
18 1<br />
15<br />
8<br />
4<br />
ar2<br />
14<br />
3 4<br />
2<br />
5<br />
GP C<br />
W<br />
R<br />
III<br />
9<br />
5<br />
6<br />
E<br />
8<br />
I<br />
7<br />
A<br />
N<br />
10<br />
V<br />
9<br />
5°/10°°<br />
18°/17°°<br />
12<br />
B<br />
XI<br />
11<br />
2)<br />
2)<br />
19 23 20<br />
hr2<br />
22 21 24<br />
hr1<br />
LDU11<br />
7696a06/0703<br />
AL<br />
4<br />
7696a11/0401<br />
N<br />
13<br />
AGK25 3)<br />
N<br />
13<br />
AL<br />
EN