10/16<br />

25<br />

420010264101 <strong>GHO</strong> - TRON 5.5000 / 5.5800 R<br />

Connection examples with vent pipe to atmosphere using burner controls type LGB2..., LGB3... or LGB4...<br />

For other connections, refer to the connection diagram of the relevant burner control.<br />

H<br />

L<br />

N<br />

Valve proving test prior to burner startup Valve proving test following immediately the controlled<br />

shutdown<br />

LGB2.../3.../4.../LMG2...<br />

12<br />

SB / R / W<br />

1 3 6<br />

12 14 19 20 22<br />

hr2<br />

21 24<br />

ar2 III<br />

17 15<br />

XI<br />

hr1<br />

N<br />

2 4 5<br />

DW<br />

16<br />

GP<br />

11 23 LDU11 13<br />

C<br />

3 4<br />

M<br />

B<br />

A1<br />

E<br />

5<br />

A2<br />

7696a05/0403<br />

10<br />

AL<br />

Plants with vent pipe to atmosphere<br />

E<br />

GP<br />

B<br />

C<br />

LDU<br />

DW<br />

A<br />

Building Technologies CC1N7696en<br />

HVAC Products 25.04.2005<br />

L<br />

N<br />

LGB2.../3.../4.../LMG2...<br />

H<br />

14 15<br />

7696s01/0695<br />

16<br />

2<br />

DW<br />

17 3<br />

ar2<br />

4<br />

C<br />

SB / R / W<br />

P<br />

1<br />

12<br />

6<br />

III<br />

5<br />

GP<br />

3<br />

M<br />

I<br />

7<br />

E<br />

5<br />

A2 A1<br />

8 12<br />

XI<br />

11<br />

B<br />

³) Only in connection with LMG2...<br />

E<br />

GP<br />

B<br />

C<br />

LDU<br />

DW<br />

A1<br />

A2<br />

19 23 20 22 21 24<br />

hr2<br />

Connection examples with vent pipe to atmosphere using burner controls type LFE..., LFL... or LGK..., or the<br />

control unit LEC...<br />

Valve proving test during the prepurge time (min. 60 seconds)<br />

and following immediately the controlled shutdown<br />

in plants with vent pipe to atmosphere.<br />

Delay on make of relay d > 2 seconds.<br />

2) Expanding flame burner or interrupted pilot burner<br />

LFE1<br />

LEC1<br />

LFL1...<br />

LGK16...<br />

EK2<br />

DW<br />

16<br />

18 1<br />

ar2<br />

3 4<br />

17<br />

15 14 2<br />

N<br />

W<br />

R<br />

d<br />

2<br />

8<br />

4<br />

9<br />

5<br />

5<br />

GP C<br />

18 19 4 5°/10°°<br />

12 1314<br />

LP<br />

6<br />

III<br />

E<br />

8<br />

I<br />

7<br />

A<br />

N<br />

10<br />

V<br />

9<br />

18°/17°°<br />

12 19 23 20 22 21 24<br />

hr2<br />

XI hr1 N<br />

11 LDU11 13<br />

B<br />

2)<br />

2)<br />

7696a10/0401<br />

AL<br />

hr1<br />

LDU11<br />

Valve proving test following immediately the controlled<br />

shutdown<br />

2) Expanding flame burner or interrupted pilot burner<br />

LFE1<br />

LEC1<br />

LFL1...<br />

LGK16...<br />

N<br />

EK2<br />

DW<br />

16<br />

17<br />

18 1<br />

15<br />

8<br />

4<br />

ar2<br />

14<br />

3 4<br />

2<br />

5<br />

GP C<br />

W<br />

R<br />

III<br />

9<br />

5<br />

6<br />

E<br />

8<br />

I<br />

7<br />

A<br />

N<br />

10<br />

V<br />

9<br />

5°/10°°<br />

18°/17°°<br />

12<br />

B<br />

XI<br />

11<br />

2)<br />

2)<br />

19 23 20<br />

hr2<br />

22 21 24<br />

hr1<br />

LDU11<br />

7696a06/0703<br />

AL<br />

4<br />

7696a11/0401<br />

N<br />

13<br />

AGK25 3)<br />

N<br />

13<br />

AL<br />

EN