<strong>Fundamentals</strong>. Two-Dimensional <strong>Design</strong><br />

616<br />

The “Main Data” tab contains standard entries of the BOM table:<br />

Group: the BOM group name is selected from the list whose set of values is stored in the file “BOM<br />

Groups.mdb”.<br />

If “” option was selected, the record will not be entered in any of the existing BOM groups.<br />

Such records are always placed in the beginning of the BOM before the header of the first group.<br />

Composition of BOM groups can be edited by the command “BG: Edit BOM Groups”.<br />

Part Description.<br />

Part Number, or name.<br />

Material.<br />

Weight.<br />

Price.<br />

Remarks.<br />

Format. With the flag “Auto” set, the value of this parameter is defined automatically. In this case, keep<br />

in mind the special way of handing multipage documents. Automatic formatting will be based on the<br />

format of the page that hosts the fixing vector of the assembled fragment data. In the case of using a 3-D<br />

fragment, the format of the first document page only is defined automatically. Therefore, definitions of a<br />

multipage document are done manually.<br />

Zone. With the flag “Auto” set, the value of this parameter is defined automatically. Automatic zone<br />

definition requires the flag “Detect Zones for Bills of Materials” be set for the assembly drawing in<br />

the command “ST: Set Model Status”, accessed by the graphic button [Zones] on the tab<br />

“General” (refer to the chapter “Customizing Drawing” for the description of setting up zones). In this<br />

case, the zones are defined either by the fragment position or by the position of the leader denoting the<br />

fragment position. Either mode can be set among BOM properties on the “BOM” tab.<br />

CAGE Code. The code required by the drafting standard.<br />

Quantity.<br />

When using arrays of fragments, the entry “Quantity” can be controlled by an introduced external<br />

variable representing the assembly variable defining the number of elements in the array.<br />

The parameter “Never include in Bills of Materials” is required for fragments used for detailing, such as<br />

title block, tables, leader notes, etc. With the flag checked, the current fragment will not be included in<br />

the assembly BOM table.<br />

The tab “Custom Data” contains the list of additional BOM table entries and allows defining arbitrary data<br />

for the BOM. By default, the list contains the names of data entries for group BOM documents and, possibly,<br />

other standard forms, depending on the T-<strong>FLEX</strong> <strong>CAD</strong> application localization. The list is stored in the file<br />

BOM Custom Data.txt, in the Program folder. This list entries may not be deleted.