<strong>Fundamentals</strong>. Two-Dimensional <strong>Design</strong><br />

“3D Input Device” Tab<br />

T-<strong>FLEX</strong> <strong>CAD</strong> supports three-dimensional<br />

multifunctional manipulators compatible with the<br />

standards Spaceball and SpaceMouse (for example,<br />

the products of 3Dconnexion, a Logitech<br />

Company, http://www.logicad3d.com). The 3D<br />

manipulators allow panning, spinning and zooming<br />

objects in the 3D window.<br />

Once such a device is attached, the “SB: Show<br />

Toolbars” dialog box gains another tab, “3D<br />

Input device”.<br />

This tab is used for setting up 3D device working environment. The user can set up device operating options<br />

in three modes: for working with <strong>2D</strong> drawings, for working in the 3D model window, and for working in the<br />

3D model window in the active workplane mode. Selection of a working mode to set up is done in the pulldown<br />

list of the parameter “View mode”.<br />

152<br />

The user can change:<br />

- Mapping of the device axes on those of the T-<strong>FLEX</strong> <strong>CAD</strong> global coordinate system; direction of<br />

action (translation or rotation) along each axis; sensitivity of the device to impacts for each type of<br />

input (the “Axes” group). The device sensitivity is adjusted by the appropriate sliders. The more a<br />

slider shifted to the right the less impact is required on the device for translating/rotating the model<br />

along this axis;<br />

- The level of filtration from accidental device disturbance (the “Filtering” parameter). The slider<br />

position defines the filtration coefficient in the range from 0 (all impacts handled) in the left-most<br />

position to 100% (only strongest impacts are handled) in the right-most position.<br />

With simultaneous impacts on several axes of the 3D device, the axis of the maximum impact is<br />

determined by the system. This impact is considered primary and is handled always. Other impacts<br />

are handled only when they exceed the product of the maximum impact and the filtration coefficient;