Main Concepts of System Operation<br />

The user actions remembered by the system can be undone by a certain number of steps back. This can be<br />

done by repeatedly calling the command “UN: Undo Changes”, that brings the system back by one step.<br />

The “UN: Undo Changes” command can be called from any other command using<br />

or combination.<br />

If the command “UN: Undo Changes” was called in error, there is the “RED: Redo Changes”<br />

command in the system, which restores the undone action. The “RED: Redo Changes” command can be<br />

called from any other command by or combination. Repeatedly<br />

calling the command “RED: Redo Changes” brings the system into the state when undoing began.<br />

The “UN: Undo Changes” command can be called as follows:<br />

Keyboard Textual Menu Icon<br />

,<br />

,<br />

<br />

“Edit|Undo”<br />

The “RED: Redo Changes” command is called via:<br />

Keyboard Textual Menu Icon<br />

,<br />

,<br />

<br />

“Edit|Redo”<br />

To cancel or repeat several actions at once, press the button on the main toolbar to the right of the icon of<br />

the corresponding command. After pressing the button the dropping list of actions which can be canceled or<br />

repeated will pop up. Then it is enough just to select the desired group of actions with the help of .<br />

General Principles of Assigning Parameters. Assigning Variables to Parameters<br />

General principles of assigning parameters<br />

Various ways of assigning parameter values are used in element creation and editing commands. These<br />

include using parameter dialog box and property window, as follows:<br />

• A parameter can be assigned a constant value. For example, the parameter "Rotation angle" of a text<br />

can be assigned 0.<br />

• A parameter value can be substituted by the string “Default”. This means, the parameter value will be<br />

set from the respective parameter of the command “ST: Set Model Status”. For example, the<br />

parameters on the “Font” tab in the parameter dialog box for dimensions, roughnesses and notes will<br />

be substituted from the “Font” tab of the command “ST: Set Model Status” when the respective<br />

elements are displayed.<br />

Using default parameters helps quickly modify elements of the whole drawing. For example, using<br />

default parameters for dimensions allows to instantly change dimension display and, therefore, the<br />

whole drawing. This can be done by modifying parameters on the “Dimensions” tab of the “ST: Set<br />

Model Status” command.<br />

• The values of most of various element parameters defined by number can be set using string variables<br />

and expressions. In this case, the parameter value will be driven by the value of the variable or<br />

expression. In this way, the value of the parameter can be changed by varying the respective variable<br />

value. This mechanism allows changing any parameters of the following T-<strong>FLEX</strong> <strong>CAD</strong> elements: the<br />

size of text boxes, the slanting angle, the size of arrows of the dimension leaders and graphic lines, etc.<br />