Table S5.26: Average observed rate constants, kobs(1 st ), at 298.15 K, for the<br />

displacement <strong>of</strong> the first aqua ligand <strong>of</strong> pht with a series <strong>of</strong><br />

nucleophiles at different concentrations.<br />

[NU]/ M kobs(1 st ), s -1<br />

TU DMTU TMTU<br />

0.00138 1. 3024 x 10 -3 3.480 x 10 -4 1.480 x 10 -4<br />

0.00276 2.4908 x 10 -3 6.850 x 10 -4 2.955 x 10 -4<br />

0.00414 3.8949 x 10 -3 1.030 x 10 -3 4.440 x 10 -4<br />

0.00552 5.1913 x 10 -3 1.390 x 10 -3 6.080 x 10 -4<br />

0.0069 6.5099 x 10 -3 — 7.892 x 10 -4<br />

Table S5.27: Average observed rate constants, kobs(2 nd ), at 298.15 K, for the<br />

displacement <strong>of</strong> the second aqua ligand <strong>of</strong> pht with a series <strong>of</strong><br />

nucleophiles at different concentrations.<br />

[NU]/ M kobs(2 nd ), s -1<br />

TU DMTU TMTU<br />

0.00138 7.454 x 10 -5 6.299 x 10 -5 2.574 x 10 -6<br />

0.00276 1.496 x 10 -4 1.249 x 10 -4 5.618 x 10 -6<br />

0.00414 2.235 x 10 -4 1.870 x 10 -4 7.987 x 10 -6<br />

0.00552 3.003 x 10 -4 2.524 x10 -4 1.109 x 10 -5<br />

0.0069 3.732 x 10 -4 3.123 x 10 -4 1.424 x 10 -5<br />