29.07.2013 Views

WebAccess and its modules for ECL Comfort 200 / 300 - Danfoss.com

WebAccess and its modules for ECL Comfort 200 / 300 - Danfoss.com

WebAccess and its modules for ECL Comfort 200 / 300 - Danfoss.com

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Data sheet<br />

<strong>WebAccess</strong> <strong>and</strong> <strong>its</strong> <strong>modules</strong><br />

<strong>for</strong> <strong>ECL</strong> Com<strong>for</strong>t <strong>200</strong> / <strong>300</strong><br />

Application The <strong>WebAccess</strong> kit enables:<br />

The <strong>WebAccess</strong> unit with <strong>its</strong> remote control<br />

<strong>and</strong> data log provides an easy access to the<br />

<strong>ECL</strong> Com<strong>for</strong>t <strong>200</strong> / <strong>300</strong> controller by means of a<br />

st<strong>and</strong>ard Internet browser.<br />

It is possible to connect up to 4 <strong>ECL</strong> Com<strong>for</strong>t<br />

controllers to each <strong>WebAccess</strong> unit. It is also<br />

possible to connect up to 10 additional <strong>modules</strong><br />

such as heat meters via LON as well as water <strong>and</strong><br />

electrical meters with pulse output.<br />

DH-SMT/DK VD.KM.G2.02 © <strong>Danfoss</strong> 09/<strong>200</strong>7<br />

• Remote monitoring <strong>and</strong> control via Internet /<br />

Intranet<br />

• Configurable alarm settings <strong>and</strong> notification<br />

of external recipients via e-mail / SMS.<br />

• Data logging of sensor <strong>and</strong> reference<br />

temperatures<br />

The <strong>com</strong>munication between the <strong>WebAccess</strong><br />

unit <strong>and</strong> the <strong>ECL</strong> Com<strong>for</strong>t controller is based on<br />

the LonWorks® protocol.<br />

The <strong>WebAccess</strong> unit can be used <strong>for</strong> the <strong>ECL</strong><br />

Cards P16, C14, C30, C37, C55, C62, C66, C75, F11,<br />

F66, <strong>and</strong> L10 in the <strong>ECL</strong> Com<strong>for</strong>t <strong>200</strong> / <strong>300</strong> series.<br />

Operating principles The <strong>WebAccess</strong> unit is a web server <strong>for</strong> the <strong>ECL</strong><br />

Com<strong>for</strong>t <strong>200</strong> / <strong>300</strong> series.<br />

By inserting the ECA 82 LON module in the <strong>ECL</strong><br />

Com<strong>for</strong>t <strong>200</strong> / <strong>300</strong> controller <strong>and</strong> connecting this<br />

to the <strong>WebAccess</strong> unit, it is possible to monitor,<br />

to log data <strong>and</strong> to control the <strong>ECL</strong> Com<strong>for</strong>t <strong>200</strong> /<br />

<strong>300</strong> controller.<br />

All logged data are stored in the <strong>WebAccess</strong> unit.<br />

All LON nodes / <strong>com</strong>ponents are set up by means<br />

of Plug <strong>and</strong> Play. No extra LON setup tools are<br />

required.<br />

No dedicated software is needed on the client’s<br />

PC.


Data sheet <strong>WebAccess</strong> <strong>and</strong> <strong>its</strong> <strong>modules</strong><br />

Ordering Description Code No.<br />

<strong>WebAccess</strong> kit* 087B1173<br />

* incl. 1 LON module <strong>and</strong> trans<strong>for</strong>mer<br />

Accessories Description Code No.<br />

LON extension module 087B1174<br />

WAS energy measuring module 087B1179<br />

Operation<br />

Digital<br />

WAH pulse interface 087B1187<br />

WAS digital input, 1 channel 087B1194<br />

WAS digital input, 2 channels 087B1195<br />

WAS digital input, 3 channels 087B1196<br />

WAS digital input, 4 channels 087B1197<br />

Analog<br />

WAH analog interface 087B1188<br />

WAS analog input, 4 channels 087B1198<br />

1. TP / FT-10 LON connection:<br />

Free topology / twisted pair<br />

2. Power supply:<br />

8-24 V a.c. or 12-30 V d.c.<br />

3. RS 232 interface <strong>for</strong> PC connection<br />

4. Ethernet connection<br />

5. TP / FT-10 LON connection:<br />

Free topology / twisted pair<br />

6. Wireless (connection type)<br />

7. Status (availability of data logger)<br />

8. 100 Mb (data transmission via Ethernet)<br />

9. Link (Ethernet connection)<br />

10. Power (power connection)<br />

11. Service condition<br />

2 VD.KM.G2.02 © <strong>Danfoss</strong> 09/<strong>200</strong>7 DH-SMT/DK


Data sheet <strong>WebAccess</strong> <strong>and</strong> <strong>its</strong> <strong>modules</strong><br />

Technical data Storage temperature -40 °C - 70 °C<br />

Ambient temperature 0 - 50 °C<br />

Weight 0.3 kg<br />

Power supply 8-24 V a.c. /12-30 V d.c.<br />

Power consumption Max. 350 mA @ 24 V d.c. / <strong>300</strong> mA @ 24 V a.c.<br />

Grade of enclosure IP00<br />

Mounting DIN rail<br />

LON port cable length / type <strong>300</strong> m max. / twisted pair<br />

Ethernet cable length / type 100 m max. / RJ 45-10 / 100 Mbit<br />

Protocol TCP / IP<br />

Modem cable length / type 1.5 m max. / DB 9 / RS 232<br />

LON typology TP / FT-10 / auto termination<br />

Data log memory >250,000 logs ~ 1 month<br />

Data log sample time / accuracy 5 sec. - 15 min. / ± 2%<br />

Log data Sensor <strong>and</strong> reference temperatures<br />

EMC immunity IEC 61000-6-2<br />

EMC emission EN 50081-2<br />

System requirements • Microsoft Explorer 6.xx browser or later<br />

versions<br />

• Adobe SVG Viewer 3.xx or later versions<br />

• Internet / Intranet connection<br />

Dimensions<br />

DH-SMT/DK VD.KM.G2.02 © <strong>Danfoss</strong> 09/<strong>200</strong>7 3


Data sheet <strong>WebAccess</strong> <strong>and</strong> <strong>its</strong> <strong>modules</strong><br />

Module<br />

WAH pulse interface<br />

Description The WAH pulse interface has 4 optically isolated<br />

digital inputs. The typical use of these inputs is<br />

to convert impulse signals to a value that can be<br />

stored in the <strong>WebAccess</strong> unit.<br />

Operation<br />

The data type can be configured to liters, kWh<br />

etc.<br />

1. TP / FT-10 LON connection:<br />

Free topology / twisted pair<br />

2. Power supply:<br />

8-24 V a.c. or 12-30 V d.c.<br />

3. TP / FT-10 LON connection:<br />

Free topology / twisted pair<br />

4. Power (power connection)<br />

5. Service condition<br />

6. Service switch (activates neuron service pin)<br />

7. Digital input, 4 channels + input power supply<br />

Technical data Storage temperature -40 °C - 70 °C<br />

Ambient temperature 0 - 50 °C<br />

Power supply 8-24 V a.c. /12-30 V d.c.<br />

Power consumption 15 mA @ 24 V d.c.<br />

Grade of enclosure IP00<br />

Mounting DIN rail<br />

LON typology TP / FT-10<br />

Input power supply Min. 15 V d.c., max. 27 V d.c.<br />

Consumption max. 60 mA @ 27 V d.c., all inputs<br />

short-circuited<br />

Number of inputs 4<br />

Input type Digital<br />

Input ON consumption >5 mA @ RI 800 ohm @ V = 15 V d.c.<br />

> 10 mA @ RI 800 ohm @ V = 27 V d.c.<br />

Input OFF consumption < 1 mA @ RI 1 Mohm @ V = 27 V d.c.<br />

Short-circuit current Max. 15 mA /input<br />

EMC immunity EN 50082-2<br />

EMC emission EN 50081-1<br />

VD.KM.G2.02 © <strong>Danfoss</strong> 09/<strong>200</strong>7 DH-SMT/DK


Data sheet <strong>WebAccess</strong> <strong>and</strong> <strong>its</strong> <strong>modules</strong><br />

Dimensions<br />

DH-SMT/DK VD.KM.G2.02 © <strong>Danfoss</strong> 09/<strong>200</strong>7


Data sheet <strong>WebAccess</strong> <strong>and</strong> <strong>its</strong> <strong>modules</strong><br />

Module<br />

WAH analog interface<br />

Description The typical use of these inputs is to convert<br />

analog signals to a value that can be stored in<br />

the <strong>WebAccess</strong> unit.<br />

Operation<br />

The data type can be configured to bar, pH etc.<br />

1. TP / FT-10 LON connection:<br />

Free topology / twisted pair<br />

2. Power supply:<br />

8-24 V a.c. or 12-30 V d.c.<br />

3. TP / FT-10 LON connection:<br />

Free topology / twisted pair<br />

4. Power (power connection)<br />

5. Service condition<br />

6. Service switch (activates neuron service pin)<br />

7. Analog input, 4 channels<br />

Technical data Storage temperature -40 °C - 70 °C<br />

Ambient temperature 0 - 50 °C<br />

Power supply 8-24 V a.c. /12-30 V d.c.<br />

Power consumption 15 mA @ 24 V d.c.<br />

Grade of enclosure IP00<br />

Mounting DIN rail<br />

LON typology TP / FT-10<br />

Input voltage 0-10 V d.c., 20 mA<br />

Number of inputs 4<br />

Input type Analog<br />

Input impedance 4 kΩ<br />

Input resolution 10 bit<br />

Short-circuit current Max. 15 mA /input<br />

EMC immunity EN 50082-2<br />

EMC emission EN 50081-1<br />

VD.KM.G2.02 © <strong>Danfoss</strong> 09/<strong>200</strong>7 DH-SMT/DK


Data sheet <strong>WebAccess</strong> <strong>and</strong> <strong>its</strong> <strong>modules</strong><br />

Dimensions<br />

DH-SMT/DK VD.KM.G2.02 © <strong>Danfoss</strong> 09/<strong>200</strong>7


Data sheet <strong>WebAccess</strong> <strong>and</strong> <strong>its</strong> <strong>modules</strong><br />

<strong>Danfoss</strong> can accept no responsibility <strong>for</strong> possible errors in catalogues, brochures <strong>and</strong> other printed material. <strong>Danfoss</strong> reserves the right to alter <strong>its</strong> products without notice. This also applies to products<br />

already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed.<br />

All trademarks in this material are property of the respective <strong>com</strong>panies. <strong>Danfoss</strong> <strong>and</strong> the <strong>Danfoss</strong> logotype are trademarks of <strong>Danfoss</strong> A/S. All rights reserved.<br />

VD.KM.G2.02 © <strong>Danfoss</strong> 09/<strong>200</strong>7 DH-SMT/DK

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!