NF BC Configuration and Full ASCII Charts<br />

POL and SEL Combinations for Multi-Drop Protocol<br />

C<br />

To configure User-Defined Multi-Drop protocol, you use POL and SEL<br />

character combinations. You must assign the POL and SEL protocol characters<br />

in a predetermined combination. The following table lists the device address<br />

and the corresponding POL and SEL combinations. When you configure<br />

Multi-Drop protocol, you select the device address and then the reader<br />

automatically sets the predefined POL and SEL combination listed for that<br />

address.<br />

Device Address POL SEL Device Address POL SEL<br />

A FS GS Q < =<br />

B RS US R > ?<br />

C SP ! S @ A<br />

D " # T B C<br />

E $ % U D E<br />

F & ‘ V F G<br />

G ( ) W H I<br />

H * + X J K<br />

I ‘ - Y L M<br />

J . / Z N O<br />

K 0 1 0 P Q<br />

L 2 3 1 R S<br />

M 4 5 2 T U<br />

N 6 7 3 V W<br />

O 8 9 4 X Y<br />

P : ; 5 Z [<br />

C-7