28.07.2013 Views

JANUS? 2020 Hand-Held Computer (4MB) - Intermec

JANUS? 2020 Hand-Held Computer (4MB) - Intermec

JANUS? 2020 Hand-Held Computer (4MB) - Intermec

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>JANUS</strong> <strong>2020</strong> <strong>Hand</strong>-<strong>Held</strong> <strong>Computer</strong> User’s Manual (<strong>4MB</strong>) NF BC<br />

Flow Control<br />

Purpose: Regulates the data transmission through the communications port. The reader<br />

is a DTE device.<br />

Clear To Send/Request To Send (CTS/RTS) is a hardware signal flow control.<br />

The reader sets RTS high when it is ready to transmit. The reader checks CTS<br />

when it tries to transmit data.<br />

XON/XOFF response causes the reader to respond to XON/XOFF characters<br />

received while transmitting. XON/XOFF control specifies that the reader<br />

transmits XON/XOFF characters to control the incoming data flow.<br />

XON/XOFF response and control specify that the reader responds to and<br />

transmits XON/XOFF characters.<br />

Default: None<br />

12-56<br />

Note: You must select the communications port and protocol before you set the<br />

parameters that define the protocol. For help, see “Communications Protocol,<br />

Configure” earlier in this chapter.<br />

Syntax: ILdata<br />

Acceptable values for data are:<br />

0 None<br />

1 CTS checking/RTS control<br />

2 XON/XOFF response<br />

3 XON/XOFF control<br />

4 XON/XOFF response and control<br />

Scan: One of these bar codes:<br />

No Flow Control CTS Checking/RTS Control<br />

*$+IL0* *$+IL1*<br />

*$+IL0* *$+IL1*<br />

XON/XOFF Response XON/XOFF Control<br />

*$+IL2* *$+IL3*<br />

*$+IL2* *$+IL3*<br />

XON/XOFF Response and Control<br />

*$+IL4*<br />

*$+IL4*