Communications Protocol (continued)<br />

Point-to-Point protocol parameters<br />

• Baud rate, parity, data bits, and stop bits<br />

• Flow control<br />

12<br />

NF BC Configuration Command Reference<br />

• Intercharacter delay, turnaround delay, and timeout delay<br />

• Transmit abort timeout<br />

Note: If you use User-Defined or Point-to-Point protocol, you should only set the<br />

Timeout Delay command if the baud rate is 9600 or lower. You should disable Timeout<br />

Delay if the baud rate for either of these protocols is set to 19200 or higher.<br />

Polling Mode D protocol parameters<br />

• Baud rate<br />

• Flow control<br />

• Transmit abort timeout<br />

User-Defined protocol parameters<br />

• Baud rate, parity, data bits, and stop bits<br />

• Flow control and LRC<br />

• Intercharacter delay, turnaround delay, and timeout delay<br />

• Transmit abort timeout<br />

• SOM, EOM (required)<br />

• AFF, NEG, POL, REQ, RES, SEL<br />

Note: You must set AFF and NEG together. If you set REQ, you must also set AFF<br />

and NEG.<br />

You use the following characters with IRL and Communications Manager.<br />

These parameters are not directly supported by the <strong>Intermec</strong> protocol handler.<br />

• EOF, EOR, and records per block<br />

• IRL parameters: BAK, End, EOP, PAK, PSS, Run, and SOP<br />

If you want to configure the reader for User-Defined Multi-Drop protocol,<br />

select User-Defined protocol. For help, see “Communications Protocol,<br />

Multi-Drop, User-Defined” later in this chapter.<br />