Communications Dock Port<br />

12<br />

NF BC Configuration Command Reference<br />

Purpose: Sets the SELPORT signal on the reader’s COM1, which selects the port on the<br />

communications dock through which the reader will communicate. When<br />

SELPORT is set to 0, the reader communicates through the dock’s network<br />

port. When SELPORT is set to 1, the reader communicates through the dock’s<br />

auxiliary port. You use the Communications Dock Port command only when<br />

the reader is in the communications dock.<br />

Default: Network<br />

Syntax: IPdata<br />

Acceptable values for data are:<br />

0 Network port<br />

1 Auxiliary port<br />

Scan: One of these bar codes:<br />

Network Port Auxiliary Port<br />

*$+IP0* *$+IP1*<br />

*$+IP0* *$+IP1*<br />