Code 39 (continued)<br />

12<br />

NF BC Configuration Command Reference<br />

Syntax: CBdata<br />

Acceptable values for data must be three digits, corresponding to:<br />

First digit: 0 Disabled<br />

1 Enabled with no check digit<br />

2 Enabled with check digit<br />

3 HIBC (Health Industry Bar Code)<br />

4 With AIAG check digit<br />

Second digit: 0 Discard check digit<br />

1 Transmit check digit<br />

Third digit: 0 Code 39 non-full ASCII<br />

1 Code 39 full ASCII<br />

2 Code 39 mixed-full ASCII<br />

Scan: To disable Code 39:<br />

Note: Selecting HIBC Code 39 automatically sets the configuration to non-full ASCII<br />

with the check digit transmitted.<br />

Disable Code 39<br />

*$+CB0*<br />

*$+CB0*<br />

Or: To enable Code 39:<br />

1. Scan this bar code:<br />

Enter Accumulate Mode / Enable Code 39<br />

*+/$+CB*<br />

*+/$+CB*<br />

2. Scan one of these bar codes to set the first digit:<br />

Without a Check Digit With a Check Digit<br />

*1* *2*<br />

*1* *2*<br />

HIBC Code 39 With AIAG Check Digit<br />

*3* *4*<br />

*3* *4*<br />

12-23