<strong>JANUS</strong> <strong>2020</strong> <strong>Hand</strong>-<strong>Held</strong> <strong>Computer</strong> User’s Manual (<strong>4MB</strong>) NF BC<br />

Entering Variable Data in a Configuration Command<br />

12-6<br />

You can enter variable data for many of the configuration commands. For<br />

example, you can set the End of File (EOF) character to any ASCII character.<br />

You need to follow these general instructions to enter variable data.<br />

To enter variable data in a configuration command<br />

1. Scan a bar code label with this syntax:<br />

+/$+command<br />

where:<br />

+/ is the syntax for the Enter Accumulate Mode command.<br />

$+ is the syntax for the Change Configuration command.<br />

command is the syntax for the command you want to change.<br />

For example, the command syntax for EOF is FAdata. To change the EOF<br />

configuration, scan this bar code:<br />

Enter Accumulate Mode / Change Configuration / Set EOF<br />

*+/$+FA*<br />

*+/$+FA*<br />

2. Scan a bar code label from the “Full ASCII Bar Code Chart” in Appendix C.<br />

To set EOF to SOH (Start of Heading), scan this label:<br />

SOH<br />

*$A*<br />

**<br />

3. Scan the Exit Accumulate Mode bar code label to update the reader’s<br />

configuration:<br />

Exit Accumulate Mode<br />

*-/*<br />

*-/*

Hooray! Your file is uploaded and ready to be published.