Using DOS Commands and Applications (continued)<br />

Problem Solution<br />

The reader locks up just after the DOS<br />

boot banner message appears when you<br />

finish updating drive C with<br />

Auto-Loader.<br />

You cannot access a drive while using<br />

Interlnk.<br />

The reader does not boot after you<br />

modified the CONFIG.SYS file.<br />

nugget<br />

nuggethelCODE39 CODE39Troubleshooting<br />

10<br />

Press Alt-F4 on the host computer and then warm boot the<br />

reader. A lockup occurs when both these conditions are true:<br />

• An active Intersvr connection to the <strong>JANUS</strong> reader exists<br />

when the reader reboots. The reader’s default CONFIG.SYS<br />

file installs Interlnk automatically when the reader is<br />

connected to COM1 of the host computer and the host is<br />

running Intersvr.<br />

• The reader’s CONFIG.SYS and AUTOEXEC.BAT install a<br />

combination of device drivers, DOS options, TSRs, and<br />

applications that absorb the majority of available conventional<br />

memory.<br />

When both conditions exist, there is not enough space for your<br />

software configuration to coexist with the Interlnk device driver.<br />

The reader attempts to allocate memory that is not available, and<br />

a lockup may occur.<br />

To prevent the lockup, press Alt-F4 on the host computer or<br />

break the serial connection between the reader and host<br />

computer before the reader reaches the DOS initialization step of<br />

the warm boot.<br />

When you exit Intersvr on the host computer or break the serial<br />

connection, the Interlnk device driver will not detect<br />

INTERSVR.EXE, and Interlnk will not be loaded into the reader’s<br />

memory.<br />

Interlnk does not redirect network drives, CD-ROM drives, or<br />

any other device that uses a redirection interface. These<br />

commands do not work with Interlnk:<br />

CHKDSK MIRROR<br />

DISKCOMP SYS<br />

DISKCOPY UNDELETE<br />

FORMAT UNFORMAT<br />

Correct the error in CONFIG.SYS. Use Auto-Loader, BFT, or<br />

MakeDisk and PutDisk to load the new CONFIG.SYS onto the<br />

reader.<br />

Boot the reader. The reader should boot with the corrected<br />

CONFIG.SYS file.<br />

10-23