27.07.2013 Views

U UNIVAC 1218 - Bitsavers

U UNIVAC 1218 - Bitsavers

U UNIVAC 1218 - Bitsavers

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

50 27<br />

instruction will transfer a word whether the buffer<br />

is active or not. The transfer takes place under<br />

control of the output buffer control registers.<br />

EXTERNAL FUNCTION OVERRIDE (EXFOV)<br />

Execution time: 4.67 microseconds<br />

Wait for the output device to accept the word in the<br />

C register(s). Then simulate an external function<br />

request on channel k and transfer the word designated<br />

by the address in the external function buffer control<br />

register for that channel. Ignore the ESI mode if active.<br />

This instruction will transfer a word whether the buffer<br />

is active or not. The transfer takes place under control<br />

of the external function buffer control registers.<br />

5. MISCELLANEOUS I/O INSTRUCTIONS<br />

The instruction repertoire includes the following instructions which are useful<br />

in programming the transfer of information between the computer and peripheral<br />

deviceso<br />

50 20<br />

50 21<br />

50 22<br />

50 23<br />

SET RESUME (SRSM)<br />

Execution time: 4 microseconds<br />

Set the resume designator for channel k group to<br />

permit honoring the next requesting output function<br />

on that group. Loss of any information currently<br />

held by that output register(s) for a peripheral<br />

device is allowed by this instruction.<br />

SKIP ON INPUT INACTIVE (SKPIIN)<br />

Execution time: 6 microseconds skip; 4.67 no skip<br />

Test for input activity on channel k. If inactive, skip<br />

the next instruction; otherwise, take the next instruction.<br />

SKIP ON OUTPUT INACTIVE (SKPOIN)<br />

Execution time: 6 microseconds; 4.67 no skip<br />

Test for output activity on channel k. If inactive, skip<br />

the next instruction; otherwise, take the next instruction.<br />

SKIP ON EXTERNAL FUNCTION INACTIVE (SKPFIN)<br />

Execution time: 6 microseconds skip; 4.67 no skip<br />

Test for external function activity on channel k. If<br />

inactive, skip the next instruction; otherwise, take the<br />

next instruction.<br />

1-8-44