25.07.2013 Views

Catalogue 2006

Catalogue 2006

Catalogue 2006

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Air Handling Units<br />

<strong>Catalogue</strong> <strong>2006</strong><br />

made of expectations


Central Europe<br />

Main Representative Offices:<br />

Poland<br />

VTS Polska Sp. z o.o.<br />

Słonecznikowa 2<br />

81-198 Kosakowo<br />

tel.: +48 58 7826319<br />

fax: +48 58 7826310<br />

e-mail: gdynia@vtsclima.com<br />

Czech Republic<br />

VTS Clima s.r.o.<br />

Zelený pruh 99<br />

140 02 Praha 4<br />

tel.: +420 241 443 839<br />

fax: +420 241 444 118<br />

e-mail: prague@vtsclima.com<br />

Slovakia<br />

VTS Clima s.r.o.<br />

Seberíniho 1<br />

821 03 Bratislava<br />

tel.: +4212 43 33 96 84<br />

fax: +4212 43 64 20 52<br />

e-mail: bratislava@vtsclima.com<br />

Lithuania<br />

UAB “VTS Clima Vilnius”<br />

Šeimyniškių g. 3a<br />

LT-09312 Vilnius<br />

tel.: +370 5 2636152-54,<br />

fax: +370 5 2636156<br />

e-mail: vilnius@vtsclima.com<br />

Latvia<br />

SIA VTS CLIMA<br />

Ganību dambis 24a<br />

Rīga, LV-1005<br />

tel.: + 371 7382530<br />

fax: + 371 7395241<br />

e-mail: riga@vtsclima.com<br />

Estonia<br />

VTS Clima OÜ<br />

Tööstuse 48a - 406<br />

Tallinn, 10413<br />

tel.: +372 6830750, +372 6830751<br />

fax: +372 6830751<br />

e-mail: tallinn@vtsclima.com<br />

Hungary<br />

VTS Clima Kft.<br />

Hungária krt. 162, Hermina Business Tower, B épület<br />

1146 Budapest<br />

tel.: +36 1 436 0100<br />

fax: +36 1 439 1636<br />

e-mail: budapest@vtsclima.com<br />

www.vtsclima.com Infocenter 0 801 222 555


Index<br />

VTS<br />

Corporation ............................................................... 2<br />

Certificates ................................................................ 3<br />

New VENTUS typeline ............................................... 4<br />

Application ................................................................. 5<br />

Design ........................................................................ 6<br />

Delivery ...................................................................... 8<br />

Operation ................................................................... 9<br />

VENTUS – Air Handling Units<br />

General description ................................................... 12<br />

How to select an AHU? ............................................. 13<br />

Symbols and labels ..................................................... 14<br />

Base AHUs and optional functions .............................. 15<br />

Quick selection ........................................................... 16<br />

Navigation .................................................................. 20<br />

Base VENTUS AHUs ................................................... 21<br />

Supply AHUs .............................................................. 21<br />

Exhaust AHUs ............................................................. 25<br />

Supply-exhaust AHUs ................................................. 27<br />

Optional functions ...................................................... 53<br />

Components .............................................................. 54<br />

Casing ........................................................................ 54<br />

Filters .......................................................................... 56<br />

Heaters ....................................................................... 58<br />

Coolers ....................................................................... 60<br />

Energy Recovery ......................................................... 62<br />

Fan sets ....................................................................... 64<br />

Mixing box, Silencers .................................................. 66<br />

Accessories ................................................................. 68<br />

Automatics<br />

Control elements ........................................................ 72<br />

Control applications .................................................... 78<br />

Psychrometric chart .................................................... 88<br />

Optional functions, accessories .......................... bookmark


Corporation<br />

VTS is a leading supplier of VENTUS air handling units.<br />

VTS was established in 1989 in Poland. Today it proudly employs<br />

more than 600 people in 54 offices located in Europe,<br />

Middle East & Africa as well as in the Asia-Pacific Region.<br />

We constantly develop and implement innovative technologies<br />

to provide our customers with excellent solutions perfectly<br />

suited to their expectations.<br />

We are able to provide perfect atmosphere in any construction<br />

project around the world – regardless of its purpose, size and<br />

climate conditions.<br />

Our units handle 885 000 000 m 3 of air every hour in more<br />

than 59 000 locations around the world. In 2005 the sales will<br />

exceed 34 000 devices.<br />

‘93 ‘94 ‘95 ‘96 ‘97 ‘98 ‘99 ‘00 ‘01 ‘02 ‘03 ‘04 ‘05 ‘06<br />

40 thousand devices


Certificates<br />

The quality and technical parameters of VTS products have been<br />

proven by the international Eurovent and TÜV certificates. We comply<br />

with all the requirements of European Product Safety Standards (CE) as<br />

well as the integrated ISO 9001/ISO 14001 Quality and Environmental<br />

Management System.<br />

ISO 9001<br />

ISO 14001<br />

Eurovent<br />

Proves the conformity of the<br />

selected VENTUS AHUs’ parameters<br />

calculated by our ClimaCAD<br />

On-line (CCOL) application,<br />

with the units’ actual operation<br />

parameters.<br />

TÜV<br />

EN 1886, EN 13053<br />

ISO 9001, ISO 14001 CE-Marking<br />

ISO 9001 guarantees full repeatability<br />

of all VTS products. ISO 14001<br />

proves effectiveness of the Environmental<br />

Management System.<br />

Two most important European<br />

branch-related standards specifying<br />

the parameters and construction of<br />

air handling units.<br />

VTS products comply with the<br />

EU safety standards.<br />

3


VENTUS is a new AHU typeline offered by VTS.<br />

New AHUs line is the result of the strategy of continuous<br />

improvement of our products – work of experienced<br />

team of engineers supported by thorough<br />

analysis of the market’s demands.<br />

Application of the latest technologies, advanced<br />

material engineering as well as implementation<br />

of completely innovative constructional solutions<br />

enabled us to create an AHU which fully satisfies<br />

market’s needs.<br />

The VENTUS typeline has been made of customers’<br />

expectations in application, design, delivery and AHU<br />

operation.<br />

made of expectations<br />

in application<br />

in delivery<br />

in design<br />

in operation


Application<br />

Wide range of capacity<br />

as many as 16 sizes!<br />

adjusting an AHUs size to<br />

capacity of an individual<br />

building<br />

Small dimensions<br />

of an AHU<br />

low AHUs – minimum<br />

height is only 36 cm!<br />

adapting a specific AHU to<br />

technical and utility rooms as<br />

well as ventilation ducts<br />

high stability of construction<br />

Any climate<br />

non-skeleton casing<br />

operation in any climatic zone<br />

(-40 do +70˚C)<br />

no thermal bridges<br />

durability for years – polyurethane<br />

foam panels<br />

air treatment functions<br />

adjusting air treatment functions<br />

to a desired microclimate<br />

5


Design<br />

ClimaCAD On-Line<br />

4 step selection of an AHU<br />

calculation possible in only<br />

few seconds<br />

analytical module – alternative<br />

results with an indication<br />

of the best solution<br />

<strong>Catalogue</strong><br />

ready sets of AHUs and<br />

control applications<br />

„quick selection”<br />

simple and clear navigation<br />

Sales and technical adviser<br />

top-class engineers specialized in AHU trade<br />

an extensive network of commercial<br />

offices<br />

assistance throughout the process of<br />

selection and purchase of a unit<br />

Infocenter<br />

detailed information about<br />

VTS’s products and services


ClimaCAD On-Line<br />

4 step selection:<br />

step 1 – selection of a base AHU<br />

step 3 – selection of an AHU out of several<br />

alternative options<br />

www.vtsclima.com<br />

step 2 – selection of optional functions and<br />

parameters<br />

step 4 - a ready AHU with a complete<br />

technical specification<br />

7


Delivery<br />

Product delivery in packages<br />

safe and convenient transport<br />

reducing the costs of logistics<br />

easy on site installation<br />

Professional installation<br />

installation as standard<br />

on site installation carried<br />

out by an authorized<br />

service centre<br />

Service assistance<br />

network of authorized service centers<br />

available 24 hours a day<br />

guarantees an AHU’s proper<br />

operation


Operation<br />

Silent operation of AHUs<br />

„Plug Fan” with<br />

a frequency converter<br />

optional sizes of fans for a<br />

single AHU size<br />

improved shape<br />

of impeller blades<br />

low air flow speed – 2,6m/s<br />

Energy recovery<br />

various types of energy recovery<br />

efficiency up to 85%<br />

separation of supply and<br />

exhaust air streams<br />

sensible and latent heat<br />

recovery<br />

Simple control<br />

HMI (Human Machine Interface)<br />

simple and clear interface<br />

reading out and setting up operation<br />

parameters from any location<br />

in a building<br />

communication with multiple<br />

number of AHUs<br />

BMS (Building Management System)<br />

system open to external control<br />

systems<br />

monitoring an AHU’s operation<br />

from any location<br />

9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!