24.07.2013 Views

high precision thermoregulation - CMS

high precision thermoregulation - CMS

high precision thermoregulation - CMS

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>high</strong> <strong>precision</strong> <strong>thermoregulation</strong><br />

Catalogue 2006


EDITORIAL<br />

What a great day!<br />

Many thanks! Your wanting to discover<br />

more about our current product range,<br />

by reading this catalogue makes this a<br />

great day!<br />

The focus of our product development<br />

is centred on process requirements for<br />

<strong>thermoregulation</strong>. Our target of remaining<br />

the leaders in environmentally-friendly<br />

refrigeration and thermal control<br />

is reflected in the catalogue.<br />

Our early and voluntary decision to<br />

cease using CFC and HCFC refrigerants<br />

in 1994 has been followed by our recent<br />

decision and ability to offer refrigeration<br />

machines that use ZERO impact refrigerants<br />

(natural refrigerants).<br />

Precise <strong>thermoregulation</strong>: The range,<br />

over 500 models wide, offers various<br />

models of cooling and heating circulators.<br />

Varying cooling and heating powers<br />

of between 0.1 kW and 130 kW with a<br />

temperature range from -120°C to 400°C<br />

guarantees that we have a product that is<br />

perfect for your application/process.<br />

We have separated the product range<br />

into three groups.<br />

1. Convential bath-circulators:<br />

the Compatible Control Range<br />

2. Hydraulically sealed circulators:<br />

the Unistats<br />

3. Chillers: the Minichillers, Unichillers<br />

Our convential bath-circulators are<br />

named „Compatible Control“ range because<br />

of their unique electronic controllers<br />

which can be freely exchanged between<br />

models. The simple models have<br />

a pressure pump and are typically used<br />

for the temperature control of objects<br />

in their bath. By using a pump adaptor<br />

they become an economical solution<br />

for the <strong>thermoregulation</strong> of small externally-closed<br />

systems (refractometers,<br />

viscometers etc.). The more sophisticated<br />

Compatible Control circulators have<br />

a <strong>high</strong> performance variable-speed<br />

pump. When used in conjunction with<br />

an optional pressure sensor, the output<br />

maximum pump pressure can be regulated.<br />

The suffix „vpc“ (Variable Pressure<br />

Control) identifies these models.<br />

In 1990, the Tango Technology and Unistats<br />

began to dominate process thermal<br />

control. Now, over fifty models allow the<br />

same thermal regulation concept to be<br />

employed from drug discovery through<br />

scale-up, pilot plant to production. Highly<br />

efficient thermal transfer capability of<br />

the unique design provides the fastest<br />

ramp rates and responses to changing<br />

thermal loads during reactions and<br />

crystallisation processes. This results in<br />

faster process times and replication of<br />

results leading to <strong>high</strong>er yields, greater<br />

purity and consumption of fewer resources.<br />

Operational safety is foremost.<br />

The Tango Technology‘s ability to transfer<br />

thermal energy makes it the safest<br />

choice and only reliable choice to control<br />

a fast-running exothermic reaction.<br />

Standing still is a backward step for us.<br />

Through your feedback we have further<br />

developed the Tango Technology. Since<br />

its conception more than fifteen years<br />

ago, the next generation of Unistats, forged<br />

in experience and driven by results<br />

is now available. The Tango Nuevo is<br />

the New Dimension! You will find more<br />

information on the „Nuevo“ at the end<br />

of the Unistat chapter.<br />

Last but not least, you will find a wide<br />

assortment of air- and water-cooled<br />

Chillers, the „Unichillers“. Unichillers<br />

have the task of removing process heat.<br />

Expensive mains-supplied cooling water<br />

is replaced by mechanically-cooled,<br />

circulating water systems. The payback<br />

time is often only a few years and, depending<br />

on operation and cost structures,<br />

may sometimes be only a few months.<br />

Unichillers can be fitted with an optional<br />

heater for operation at <strong>high</strong>er temperatures.<br />

More in-depth technical information on<br />

the products can be found at the back of<br />

the catalogue.<br />

We look forward to receiving your questions<br />

and further requests.<br />

... have a great day!<br />

Daniel Huber


Compatible Control Thermostats<br />

Huber Software<br />

SpyLight 24<br />

SpyWatch 24<br />

SpyControl 24<br />

Unistats with Tango Technology<br />

Introduction, Concept 25<br />

The Tango Technology explained 28<br />

Unistat Range 29<br />

Calibration Baths, Specials, Unistat Nuevo 34<br />

Accessories 36<br />

Unichillers<br />

Introduction, Concept 37<br />

Bench Top models 38<br />

Tower Casing models 39<br />

Unichiller ETH, Rotacool 42<br />

Accessories 43<br />

Specials<br />

Hotbox 44<br />

Beer „Force Ageing“ Thermostats 44<br />

Accessories<br />

Thermal Fluids 45<br />

Adapters, Tubing 46<br />

Quick Finder<br />

Quick Finder Thermostats 48<br />

Quick Finder Chillers 49<br />

Technical Data<br />

Technical Data 50<br />

Glossary<br />

Thermodynamic Terms explained 60<br />

General<br />

CONTENTS<br />

Introduction, Concept 4<br />

Heating Bath Thermostats 7<br />

Cooling Bath Thermostats 11<br />

Ministat Family 14<br />

Accessories 19<br />

Hotline-Service 62<br />

3-2-1 Warranty 62<br />

Extract from Terms and Conditions 62


ompatible<br />

ontrol Thermostats<br />

Thermostat<br />

Plug & Play<br />

New in Blue, „Plug and<br />

Advances in microprocessor and display technologies<br />

together with feedback from our customer and user<br />

base has driven us to take our controllers to a new level<br />

of functionality.<br />

4 www.huber-online.com · Tel. +49-781-96030


Plug & Play<br />

3 Years<br />

Warranty<br />

ompatible<br />

It‘s so easy ontrol Thermostats<br />

Thermostat<br />

The controllers are microprocessor<br />

based and have all of the features that<br />

are expected but we would like to concentrate<br />

on what the controllers have<br />

that brings a unique dimension of flexibility<br />

and functionality to your laboratory.<br />

Differentiating facts<br />

– 3-year replacement warranty<br />

– User level and password protected<br />

Administrator level. The Administrator<br />

level allows the Administrator to lockout<br />

functions that are not required or<br />

should not be accessed by the operator<br />

– A uniformity of operation means that<br />

you only need to know how to drive one<br />

controller to know how to drive all three<br />

controllers and the equipment to which<br />

they are fitted.<br />

– The controllers are fitted with an encoder<br />

that the user “turns to search and<br />

pushes to select” the required menu option.<br />

– A full text alphabetically arranged<br />

user menu makes the new controllers<br />

intuitively easier to operate.<br />

Controller Options<br />

Play“ Technology<br />

Interchangeable controllers through “Plug & Play” technology<br />

– The controllers are not an “integral”<br />

part of the machine that they are fitted<br />

to. They can be exchanged by simply<br />

un-plugging the current controller and<br />

plugging in a new one.<br />

The display can be customised to show<br />

as much information as the user requires<br />

… from simply the bath temperature to<br />

a real time “program progress” display.<br />

Controller CC1 – Basic and practical<br />

New…User and Administrator levels<br />

New…Digital encoder “turn to search -<br />

push to select”<br />

New…48 character, 4-line LCD display<br />

New…Full character user menu<br />

Visual and audible alarms<br />

Also includes programmable alarm functions<br />

Microprocessor based controller ... and more.<br />

Controller CC2 – External process oriented<br />

All that the CC1 is furnished with plus<br />

Process control capability, Ramping function,<br />

5-step internal programmer ... and more.<br />

Controller CC3 – Automation capable<br />

All that the CC2 is furnished with plus<br />

10-program, 50 step internal programmer<br />

RS232, RS485 and analogue interfaces<br />

... and more.<br />

www.huber-online.com · Tel. +49-781-96030<br />

5


ompatible<br />

ontrol Thermostats<br />

Thermostat<br />

Concept<br />

Simple, Functional,<br />

Flexible and Robust<br />

Temperature control with in-built flexible control options to address applications and<br />

processes not yet thought of! The principle of Plug-and-Play technology has given our<br />

customers the ability to swap or upgrade systems since 1980.<br />

Because you cannot predict the future,<br />

controllers with Plug-and-Play technology<br />

enable you to adapt to it. The Huber<br />

“Compatible Controllers” fitted to our<br />

thermostats, circulators and chillers are<br />

fully interchangeable with each other.<br />

Upgrading to more features or ease of<br />

support will never be simpler.<br />

The Environment Fully Protected<br />

All Huber refrigeration machines are<br />

CFC and HCFC free. We also are able to<br />

offer refrigeration machines with natural<br />

refrigerants which have ZERO IMPACT<br />

on the environment.<br />

Plug & Play Technology<br />

The CC1, CC2 and CC3 controllers are<br />

fully interchangeable by the user. Designed<br />

for post sale flexibility and support,<br />

they provide the user with varying<br />

control options easily accessed through<br />

an intuitive menu driven display. The<br />

Ministat range offers this flexibility with<br />

the added advantage giving powerful<br />

heating and cooling from an extremely<br />

compact design.<br />

General Purpose, Low Duty Thermostats<br />

Starting with units designed for general<br />

and simple thermal control applications<br />

in the temperature range of -30…200°C,<br />

the range offers options of available bath<br />

materials. Baths constructed from Polycarbonate<br />

(A-series) or stainless steel<br />

(B-series) are available. Baths with the<br />

6 www.huber-online.com · Tel. +49-781-96030<br />

VPC<br />

Variable Pressure<br />

Control New!<br />

Option: Natural<br />

Refrigerants<br />

refrigeration plant built in are also available<br />

(K-series).<br />

All of the units are designed and built<br />

to conform to DIN12876 and are fitted<br />

with “Run dry” protection and an adjustable<br />

independent “Over-Temperature”<br />

cut-out.<br />

VPC-Models for Higher Demands<br />

For more demanding applications, the<br />

“VPC“range provides more powerful<br />

heating and cooling over a wider temperature<br />

range (-90…300°C) together<br />

with powerful and adjustable pumps.<br />

(Pressure and suction)<br />

Constructed from robust stainless steel,<br />

the practical, functional and sturdy design<br />

gives an unrivalled functional longevity<br />

to these units.<br />

Available as either heating only or heating/cooling<br />

units, the VPC range offers<br />

cooling powers up to 7 kW @ 20°C and<br />

heating powers up to 4 kW. The functional<br />

design gives a further dimension<br />

of flexibility by allowing the use of a<br />

“Calibration Insert” or a “Displacement<br />

Insert” to tune the units to specific applications.<br />

Options for the VPC-range include<br />

“ComBox” (to NAMUR) communication<br />

system/protocol and an external pressure<br />

sensor.<br />

All of the units are designed and built<br />

to conform to DIN12876 and are fitted<br />

with “Run dry” protection and an adjustable<br />

independent “Over-Temperature”<br />

cut-out.<br />

Plug & Play<br />

3 Years<br />

Warranty<br />

VPC Facts<br />

Thermal Insulation<br />

The thermal insulation is constructed<br />

to be vapour-tight over the life of the<br />

unit. The bath and outer surfaces are<br />

welded directly together. No seals or<br />

gaskets. Everything is in one entire<br />

piece.<br />

Stainless Steel Construction<br />

Quality, functionality and longevity.<br />

Stainless steel is used throughout<br />

which makes them resistive to corrosion<br />

and easy to clean.<br />

High Watts/Litre Ratio [W/L]<br />

Faster response, quicker cooling, faster<br />

heating. Compact designs and low<br />

volume baths so that you get more of<br />

the power you paid for!.<br />

High Power Density [W/dm³]<br />

High cooling powers in compact cases<br />

means more power for less bench<br />

space consumed. The Ministats are<br />

the shining example here!<br />

Air-Cooled or Water-Cooled or both!<br />

Standard options are for air or water<br />

cooled refrigerated units. The “wl”<br />

versions have both so that rejected<br />

heat can help warm the lab in winter<br />

when in the air-cooled mode and in<br />

summer time, the rejected heat can be<br />

carried away when used in the watercooled<br />

mode.


Immersion Thermostats<br />

The CC-E Immersion Thermostats are<br />

the basis for many combinations using<br />

polycarbonate and stainless steel baths.<br />

In combination with a cooling both, exact<br />

and reproducible temperatures down<br />

to -30°C can be achieved.<br />

ompatible<br />

Heating Thermostats ontrol Thermostats<br />

Thermostat<br />

CC1-E<br />

Simple<br />

CC2-E<br />

Versatile<br />

CC3-E<br />

Interactive<br />

Model Temperature Temperature Heating Pressure Pump Safety Dimensions Cat.No. G Price<br />

Range Stability* Power max. Class** W x D x H / ID<br />

[°C] [K] [kW] [l/min] [bar] [mm]<br />

CC1-E (prev.: Polystat cc1) (-30) 25..200 0,02 2,0 10 0,2 FL, III 120x135x300/150 688.0051 1<br />

CC2-E (prev.: Polystat cc2) (-30) 25..200 0,02 2,0 10 0,2 FL, III 120x135x300/150 688.0052 1<br />

CC3-E (prev.: Polystat cc3) (-30) 25..200 0,02 2,0 10 0,2 FL, III 120x135x300/150 688.0053 1<br />

* to DIN 12876, measured in a stainless steel tank 12 litres ** FL for flammable liquids<br />

III = adjustable overtemperature protection and addition low-liquid level protection<br />

Bridge Thermostats<br />

The Bridge Thermostats have a “vpc“ variable speed pressure-suction<br />

pump. Models with larger heating capacities are<br />

available for use with large baths. The telescopic arm can be<br />

extended up to max. 880 mm, for use with wider baths.<br />

VPC<br />

Variable Pressure<br />

Control<br />

Model Temperature Heating Temperature Pump Data Cat.No. G Price<br />

Range Power Stability to max. Pressure max. Suction<br />

[°C] [kW] DIN 12876 [K] [l/min] [bar] [l/min] [bar]<br />

CC1-300B2X vpc (prev.: CC302BX-1) (-20)28..300 2,0 0,02 33 0,7 22 0,4 683.0011BX 1<br />

CC2-300B2X vpc (prev.: CC302BX-2) (-20)28..300 2,0 0,02 33 0,7 22 0,4 683.0012BX 1<br />

CC3-300B2X vpc (prev.: CC302BX-3) (-20)28..300 2,0 0,02 33 0,7 22 0,4 683.0013BX 1<br />

CC1-300B4X vpc (prev.: CC303BX-1) (-20)28..300 3,0/4,0 0,02 33 0,7 22 0,4 684.0011BX 1<br />

CC2-300B4X vpc (prev.: CC303BX-2) (-20)28..300 3,0/4,0 0,02 33 0,7 22 0,4 684.0012BX 1<br />

CC3-300B4X vpc (prev.: CC303BX-2) (-20)28..300 3,0/4,0 0,02 33 0,7 22 0,4 684.0013BX 1<br />

Accessories see page 19.., 45.. www.huber-online.com · Tel. +49-781-96030<br />

7


ompatible<br />

ontrol Thermostats<br />

Thermostat<br />

Heating Thermostats<br />

Heating Bath Thermostats with Polycarbonate bath<br />

The transparent polycarbonate baths are suitable for use up to 100°C. A CC-E Immersion Thermostat is mounted on the bath<br />

bridge for all models. With a pump adaptor, this combination can also be used with external, closed applications. The temperature<br />

stability, in accordance with DIN 12876, is 0.02K .<br />

CC3-118A<br />

CC1-111A CC3-105A<br />

CC2-107A<br />

CC1-106A<br />

Model Temperature Bath Bath Bath Opening Pressure Pump Dimensions Cat.No. G Price<br />

max. Volume Depth W x D max. W x D x H<br />

[°C] [ltr] [mm] [mm] [l/min] [bar] [mm]<br />

CC1-105A (prev.: Polystat A5-1) 100 5 150 120x110 10 0,2 132x280x320 405.0001 1<br />

CC2-105A (prev.: Polystat A5-2) 100 5 150 120x110 10 0,2 132x280x320 405.0002 1<br />

CC3-105A (prev.: Polystat A5-2) 100 5 150 120x110 10 0,2 132x280x320 405.0003 1<br />

CC1-106A (prev.: Polystat A6-1) 100 6 150 120x210 10 0,2 132x380x320 405.0011 1<br />

CC2-106A (prev.: Polystat A6-2) 100 6 150 120x210 10 0,2 132x380x320 405.0012 1<br />

CC3-106A (prev.: Polystat A6-3) 100 6 150 120x210 10 0,2 132x380x320 405.0013 1<br />

CC1-107A (prev.: Polystat A7-1) 100 7 150 120x310 10 0,2 132x480x320 405.0021 1<br />

CC2-107A (prev.: Polystat A7-2) 100 7 150 120x310 10 0,2 132x480x320 405.0022 1<br />

CC3-107A (prev.: Polystat A7-3) 100 7 150 120x310 10 0,2 132x480x320 405.0023 1<br />

CC1-111A (prev.: Polystat A11-1) 100 11 150 302x165 10 0,2 333x313x325 405.0031 1<br />

CC2-111A (prev.: Polystat A11-2) 100 11 150 302x165 10 0,2 333x313x325 405.0032 1<br />

CC3-111A (prev.: Polystat A11-3) 100 11 150 302x165 10 0,2 333x313x325 405.0033 1<br />

CC1-118A (prev.: Polystat A18-1) 100 18 150 302x325 10 0,2 333x473x325 405.0041 1<br />

CC2-118A (prev.: Polystat A18-2) 100 18 150 302x325 10 0,2 333x473x325 405.0042 1<br />

CC3-118A (prev.: Polystat A18-3) 100 18 150 302x325 10 0,2 333x473x325 405.0043 1<br />

CC1-130A Visco 3 80 31 370 90x90 10 0,2 500x200x560 405.0051 1<br />

CC2-130A Visco 3 80 31 370 90x90 10 0,2 500x200x560 405.0052 1<br />

CC3-130A Visco 3 80 31 370 90x90 10 0,2 500x200x560 405.0053 1<br />

CC1-130A Visco 5 80 31 370 Ø 51 10 0,2 500x200x560 405.0061 1<br />

CC2-130A Visco 5 80 31 370 Ø 51 10 0,2 500x200x560 405.0062 1<br />

CC3-130A Visco 5 80 31 370 Ø 51 10 0,2 500x200x560 405.0063 1<br />

Plug & Play<br />

3 Years<br />

Warranty<br />

8 www.huber-online.com · Tel. +49-781-96030 Accessories see page 19.., 45..


Heating Thermostats with Stainless steel bath<br />

ompatible<br />

Heating Thermostats ontrol Thermostats<br />

Thermostat<br />

The insulated stainless steel baths are suitable for use up to 200°C. All models have a bridge-mounted CC-E Immersion Thermostat.<br />

With a pump adaptor, this combination can also be used with external, closed applications. The temperature stability,<br />

in accordance with DIN 12876, is 0.02K.<br />

CC3-220B<br />

CC1-215B CC3-212B<br />

CC1-208B<br />

Model Temperature Bath Bath Bath Opening Pressure Pump Dimensions Cat.No. G Price<br />

max. Volume Depth W x D max. W x D x H<br />

[°C] [ltr] [mm] [mm] [l/min] [bar] [mm]<br />

CC1-208B (prev.: Polystat B8-1) 200 8,5 150 235x165 10 0,2 290x350x375 407.0001 1<br />

CC2-208B (prev.: Polystat B8-2) 200 8,5 150 235x165 10 0,2 290x350x375 407.0002 1<br />

CC3-208B (prev.: Polystat B8-3) 200 8,5 150 235x165 10 0,2 290x350x375 407.0003 1<br />

CC1-212B (prev.: Polystat B12-1) 200 12 150 295x193 10 0,2 350x375x375 407.0011 1<br />

CC2-212B (prev.: Polystat B12-2) 200 12 150 295x193 10 0,2 350x375x375 407.0012 1<br />

CC3-212B (prev.: Polystat B12-3) 200 12 150 295x193 10 0,2 350x375x375 407.0013 1<br />

CC1-215B (prev.: Polystat B15-1) 200 15 200 295x193 10 0,2 350x375x420 407.0021 1<br />

CC2-215B (prev.: Polystat B15-2) 200 15 200 295x193 10 0,2 350x375x420 407.0022 1<br />

CC3-215B (prev.: Polystat B15-3) 200 15 200 295x193 10 0,2 350x375x420 407.0023 1<br />

CC1-220B (prev.: Polystat B20-1) 200 20 150 295x370 10 0,2 350x555x375 407.0031 1<br />

CC2-220B (prev.: Polystat B20-2) 200 20 150 295x370 10 0,2 350x555x375 407.0032 1<br />

CC3-220B (prev.: Polystat B20-3) 200 20 150 295x370 10 0,2 350x555x375 407.0033 1<br />

CC1-225B (prev.: Polystat B25-1) 200 25 200 295x370 10 0,2 350x555x420 407.0041 1<br />

CC2-225B (prev.: Polystat B25-2) 200 25 200 295x370 10 0,2 350x555x420 407.0042 1<br />

CC3-225B (prev.: Polystat B25-3) 200 25 200 295x370 10 0,2 350x555x420 407.0043 1<br />

Accessories see page 19.., 45..<br />

www.huber-online.com · Tel. +49-781-96030<br />

9


ompatible<br />

ontrol Thermostats<br />

Thermostat<br />

Heating Circulation Thermostats<br />

Heating Thermostats<br />

Good things come in small packages! Thanks to<br />

their low bath volumes the CC202C and CC205B are<br />

especially suitable to control the temperature of small<br />

external application. The temperature of small objects<br />

can also be controlled by placing them directly in the<br />

bath of the CC202C. Both models are available in the<br />

variants: CC1 – simple; CC2 – comfortable; and CC3 –<br />

communications equipped. The maximum temperature<br />

is 200°C. The temperature stability, in accordance with<br />

DIN 12876, is 0.05K. CC3-205B<br />

CC2-202C<br />

Model Temperature Bath Bath Opening Heating Pressure Pump Dimensions Cat.No. G Price<br />

Range Depth W x D Power max. W x D x H<br />

[°C] [mm] [mm] [kW] [l/min] [bar] [mm]<br />

CC1-202C (prev.: Polystat 201-1) (-30)45..200 150 Ø25 2,0 10 0,2 150x215x350 685.0011 1<br />

CC2-202C (prev.: Polystat 201-2) (-30)45..200 150 Ø25 2,0 10 0,2 150x215x350 685.0012 1<br />

CC3-202C (prev.: Polystat 201-3) (-30)45..200 150 Ø25 2,0 10 0,2 150x215x350 685.0013 1<br />

CC1-205B (prev.: Polystat 202-1) (-30)45..200 150 105x90 2,0 10 0,2 150x285x350 686.0011 1<br />

CC2-205B (prev.: Polystat 202-2) (-30)45..200 150 105x90 2,0 10 0,2 150x285x350 686.0012 1<br />

CC3-205B (prev.: Polystat 202-3) (-30)45..200 150 105x90 2,0 10 0,2 150x285x350 686.0013 1<br />

Heating Bath- and Circulation thermostats<br />

Temperatures up to 300°C- the extremely compact models have the<br />

smoothly controllable “vpc” pressure and suction pump. The pump<br />

pressure can be controlled from the user-menu, using an optional pressure<br />

sensor, so protecting your glassware or other delicate apparatus<br />

from breakage.<br />

CC2-315B vpc<br />

CC3-308B vpc<br />

CC1-304B vpc<br />

CC315B vpc CC308B vpc CC304B vpc<br />

Bath Depth:<br />

200 mm<br />

Bath Depth:<br />

155 mm<br />

Bath Depth:<br />

145 mm<br />

Model Temperature Bath Heating Temperature Pump Data Cat.No. G Price<br />

Range Volume Power Stability to max. Pressure max. Suction<br />

[°C] [ltr] [kW] DIN 12876 [K] [l/min] [bar] [l/min] [bar]<br />

CC1-304B vpc (prev.: CC301-1) (-20)28..300 4,0 2,0 0,02 33 0,7 22 0,4 679.0001 1<br />

CC2-304B vpc (prev.: CC301-2) (-20)28..300 4,0 2,0 0,02 33 0,7 22 0,4 679.0002 1<br />

CC3-304B vpc (prev.: CC301-3) (-20)28..300 4,0 2,0 0,02 33 0,7 22 0,4 679.0003 1<br />

CC1-308B vpc (prev.: CC302-1) (-20)28..300 8,5/5,2* 3,0 0,02 33 0,7 22 0,4 683.0021 1<br />

CC2-308B vpc (prev.: CC302-2) (-20)28..300 8,5/5,2* 3,0 0,02 33 0,7 22 0,4 683.0022 1<br />

CC3-308B vpc (prev.: CC302-3) (-20)28..300 8,5/5,2* 3,0 0,02 33 0,7 22 0,4 683.0023 1<br />

CC1-315B vpc (prev.: CC303-1) (-20)28..300 15/8,5* 3,0/4,0 0,02 33 0,7 22 0,4 684.0011 1<br />

CC2-315B vpc (prev.: CC303-2) (-20)28..300 15/8,5* 3,0/4,0 0,02 33 0,7 22 0,4 684.0012 1<br />

CC3-315B vpc (prev.: CC303-3) (-20)28..300 15/8,5* 3,0/4,0 0,02 33 0,7 22 0,4 684.0013 1<br />

* with displacement insert<br />

405<br />

110<br />

130<br />

VPC<br />

Variable Pressure<br />

Control<br />

10 www.huber-online.com · Tel. +49-781-96030 Accessories see page 19.., 45..


Cooling Bath Thermostats<br />

CC2-K20<br />

ompatible<br />

Cooling Thermostats ontrol Thermostats<br />

Thermostat<br />

The combination of the CC-E immersion thermostat with an insulated cooling bath is the economical alternative for application<br />

temperatures from -20°C/-30°C to 200°C. With a pump adaptor (see accessories page 22) this combination can also be used for<br />

external, closed applications. Pump: maximum flow 10 l/min; maximum pressure 0.2 bar. The temperature stability, in accordance<br />

with DIN 12876, is 0.02K. Safety classification FL, III.<br />

CC3-K15<br />

Plug & Play<br />

3 Years<br />

Warranty<br />

Natural<br />

Refrigerants<br />

CC1-K12<br />

Model Temperature Bath Bath Bath Opening Cooling Power [kW] at Dimensions Cat.No. G Price<br />

Range Volume Depth W x D 0°C -10°C -20°C W x D x H<br />

[°C] [ltr] [mm] [mm] [mm]<br />

CC1-K12 (prev.: Polystat K12-1) -20..(50)200 12 150 295x193 0,18 0,1 – 350x558x375 653.0021 2<br />

CC2-K12 (prev.: Polystat K12-2) -20..(50)200 12 150 295x193 0,18 0,1 – 350x558x375 653.0022 2<br />

CC3-K12 (prev.: Polystat K12-3) -20..(50)200 12 150 295x193 0,18 0,1 – 350x558x375 653.0023 2<br />

CC1-K15 (prev.: Polystat K15-1) -20..(50)200 15 200 295x193 0,2 0,12 – 350x558x400 645.0031 2<br />

CC2-K15 (prev.: Polystat K15-2) -20..(50)200 15 200 295x193 0,2 0,12 – 350x558x400 645.0032 2<br />

CC3-K15 (prev.: Polystat K15-3) -20..(50)200 15 200 295x193 0,2 0,12 – 350x558x400 645.0033 2<br />

CC1-K20 (prev.: Polystat K20-1) -30..(50)200 20 150 295x370 0,35 0,3 0,21 350x558x530 646.0031 2<br />

CC2-K20 (prev.: Polystat K20-2) -30..(50)200 20 150 295x370 0,35 0,3 0,21 350x558x530 646.0032 2<br />

CC3-K20 (prev.: Polystat K20-3) -30..(50)200 20 150 295x370 0,35 0,3 0,21 350x558x530 646.0033 2<br />

CC1-K25 (prev.: Polystat K25-1) -30..(50)200 25 200 295x370 0,35 0,3 0,21 350x558x580 647.0031 2<br />

CC2-K25 (prev.: Polystat K25-2) -30..(50)200 25 200 295x370 0,35 0,3 0,21 350x558x580 647.0032 2<br />

CC3-K25 (prev.: Polystat K25-3) -30..(50)200 25 200 295x370 0,35 0,3 0,21 350x558x580 647.0033 2<br />

Accessories see page 19.., 45..<br />

www.huber-online.com · Tel. +49-781-96030<br />

11


ompatible<br />

ontrol Thermostats<br />

Thermostat<br />

Variostat cc –<br />

The Cooling and Heating Thermostat<br />

for variable bath sizes<br />

Unique in the world. The Variostat can control the<br />

temperature in any bath size from -30°C to 150°C.<br />

The single-minded construction allows the user the<br />

greatest flexibility. The smooth, controllable “vpc”<br />

pressure and suction pump, allows the circulation<br />

in any bath size to be optimally controlled. Also, the<br />

pump pressure to an external application can be precisely<br />

set and controlled, from the user-menu, using<br />

an optional pressure.<br />

Insulated baths made of stainless steel in three standard<br />

or custom dimensions. Fitted with a drain.<br />

Position 1 Position 2<br />

Cooling Thermostats<br />

Volume End Cooling Time* [min] Free Bath Opening [mm]<br />

Temperature with Ethanol to Position 1 Position 2<br />

[Litre] [°C] 0°C -10°C -20°C A1 B1 C1 A2 B2 C2<br />

5,5 -30 15 30 55 60 60 – 60 75 –<br />

11,0 -25 30 60 110 200 200 45 200 215 30<br />

22,0 -20 65 130 240 300 320 165 320 315 150<br />

* Cooling time, measured with 2/3 of bath covered<br />

Variostat Baths Bath Depth Bath Opening W x D Cat.No. G Price<br />

Standard* 5,5 Litre 165 mm 228x156 mm 6052 2<br />

11 Litre 165 mm 368x196 mm 6053 2<br />

22 Litre 165 mm 468x316 mm 6054 2<br />

Ball Valve M16x1 6091 1<br />

Insulated Cover for: Cat.No. G Price<br />

Bath 5,5 Litre 6176 2<br />

Bath 11 Litre 6178 2<br />

Bath 22 Litre 6180 2<br />

* Custom sizes on request<br />

Model Working Tem- Bath Heating Pump Data Cooling Power [kW] Dimensions Cat.No. G Price<br />

perature Range Volume Power max. Pressure max. Suction at [°C] W x D x H<br />

[°C] [ltr] [kW] [l/min] [bar] [l/min] [bar] 100 20 0 -20 -30 [mm]<br />

variostat cc-1 -30..150 variabel 1,0 18 0,6 12 0,3 0,3 0,3 0,2 0,12 0,03 183x455x395 654.0011 2<br />

3 controller options Temperature Stability to DIN 12876: 0,02 K<br />

12 www.huber-online.com · Tel. +49-781-96030<br />

Option:<br />

Natural<br />

Refrigerants<br />

(Page 50...)<br />

Accessories see page 19.., 45..


Cooling-Bath Thermostats<br />

Accessories see page 19.., 45..<br />

ompatible<br />

Cooling Thermostats ontrol Thermostats<br />

Thermostat<br />

The K6 Models are the compact cooling and heating bath thermostats for temperatures from -25°C to 200°C. Heating capacity<br />

2 kW. With the integrated pump adaptor, the combination of this miniature cooling bath and the CC-E immersion thermostat<br />

can alsp be used for external, closed applications. The K6 is the economical alternative to the Ministat 125 (page 14), the smallest<br />

cooling thermostat in the world. Bestseller since 1976. The small size and large capability of the Ministats, with variable<br />

speed pump, is captivating.<br />

CC1-K6 CC2-K6 CC3-K6<br />

Model Working Tem- Bath Bath Cooling Power [kW] Pressure Pump Dimensions Cat.No. G Price<br />

perature Range Volume Depth at [°C] max. W x D x H<br />

[°C] [ltr] [mm] 0 -10 -20 [l/min] [bar] [mm]<br />

CC1-K6 (prev.: Polystat K6-1) -25..200 4,5 150 0,15 0,1 0,05 10 0,2 210x370x535 666.0021 2<br />

CC2-K6 (prev.: Polystat K6-2) -25..200 4,5 150 0,15 0,1 0,05 10 0,2 210x370x535 666.0022 2<br />

CC3-K6 (prev.: Polystat K6-3) -25..200 4,5 150 0,15 0,1 0,05 10 0,2 210x370x535 666.0023 2<br />

Option:<br />

Natural<br />

Refrigerants<br />

(Page 50...)<br />

www.huber-online.com · Tel. +49-781-96030<br />

13


ompatible<br />

ontrol Thermostats<br />

Thermostat<br />

The Ministat Family<br />

– proves that size is no guarantee of power<br />

Pound for pound, the Ministat range is<br />

more powerful then any other thermostat<br />

in the world. Comfortable in all locations,<br />

it has proved especially useful<br />

when space is restricted such as fume<br />

cabinets or crowded benches.<br />

Robustness:<br />

– The case and base of the Ministats are<br />

completely manufactured from stainless<br />

steel.<br />

Choice of controller:<br />

– The controller available in 3 versions<br />

in the same way as the Polystat controllers.<br />

(Please see “Controller options”<br />

inset opposite).<br />

Application flexibility:<br />

– Air-cooled or water-cooled refrigeration<br />

machine<br />

– There is an adjustable pump fitted.<br />

– User fitted “Displacement Insert” reduces<br />

bath volume and directs power<br />

to the external application (Option)<br />

– User fitted “Calibration Insert” improves<br />

control stability to better than<br />

0,01K (DIN 12876) allows for labora-<br />

Ministats<br />

Model Working Tem- Bath Bath Heating Pump Data Cooling Power [kW] Cat.No. G Price<br />

perature Range Volume W x D / ID Power max. Pressure max. Suction at [°C]<br />

[°C] [ltr] [mm] [kW] [l/min] [bar] [l/min] [bar] 20 0 -20<br />

ministat 125-1 -25..150 2,75/1,3* 178x80/120 1,0 27 0,7 20 0,4 0,30 0,21 0,05 740.0001 2<br />

ministat 125-2 -25..150 2,75/1,3* 178x80/120 1,0 27 0,7 20 0,4 0,30 0,21 0,05 740.0002 2<br />

ministat 125-3 -25..150 2,75/1,3* 178x80/120 1,0 27 0,7 20 0,4 0,30 0,21 0,05 740.0003 2<br />

ministat 125w-1 -25..150 2,75/1,3* 178x80/120 1,0 27 0,7 20 0,4 0,30 0,20 0,10 740.0011 2<br />

ministat 125w-2 -25..150 2,75/1,3* 178x80/120 1,0 27 0,7 20 0,4 0,30 0,20 0,10 740.0012 2<br />

ministat 125w-3 -25..150 2,75/1,3* 178x80/120 1,0 27 0,7 20 0,4 0,30 0,20 0,10 740.0013 2<br />

ministat 230-1 -33..200 3,2/1,7* 170x83/135 2,0 27 0,7 20 0,4 0,40 0,35 0,25 741.0001 2<br />

ministat 230-2 -33..200 3,2/1,7* 170x83/135 2,0 27 0,7 20 0,4 0,40 0,35 0,25 741.0002 2<br />

ministat 230-3 -33..200 3,2/1,7* 170x83/135 2,0 27 0,7 20 0,4 0,40 0,35 0,25 741.0003 2<br />

ministat 230w-1 -33..200 3,2/1,7* 170x83/135 2,0 27 0,7 20 0,4 0,40 0,35 0,25 741.0011 2<br />

ministat 230w-2 -33..200 3,2/1,7* 170x83/135 2,0 27 0,7 20 0,4 0,40 0,35 0,25 741.0012 2<br />

ministat 230w-3 -33..200 3,2/1,7* 170x83/135 2,0 27 0,7 20 0,4 0,40 0,35 0,25 741.0013 2<br />

ministat 240-1 -40..200 4,9/2,8* 200x85/157 2,0 27 0,7 20 0,4 0,55 0,50 0,35 742.0001 2<br />

ministat 240-2 -40..200 4,9/2,8* 200x85/157 2,0 27 0,7 20 0,4 0,55 0,50 0,35 742.0002 2<br />

ministat 240-3 -40..200 4,9/2,8* 200x85/157 2,0 27 0,7 20 0,4 0,55 0,50 0,35 742.0003 2<br />

ministat 240w-1 -40..200 4,9/2,8* 200x85/157 2,0 27 0,7 20 0,4 0,55 0,50 0,35 742.0011 2<br />

ministat 240w-2 -40..200 4,9/2,8* 200x85/157 2,0 27 0,7 20 0,4 0,55 0,50 0,35 742.0012 2<br />

ministat 240w-3 -40..200 4,9/2,8* 200x85/157 2,0 27 0,7 20 0,4 0,55 0,50 0,35 742.0013 2<br />

* with displacement insert Temperature Stability to DIN 12876: 0,02 K<br />

14 www.huber-online.com · Tel. +49-781-96030<br />

tory based calibrations (Option)<br />

– Option: ComBox (NAMUR standard)<br />

The case and bath are pressed from the<br />

same sheet of stainless steel. This eliminates<br />

the need for a gasket between the<br />

bath and the frame.<br />

Thermal transfer from the bath to the<br />

outer casing is prevented by an innovative<br />

thermal control system that prevents<br />

build up of condensation around<br />

the bath opening when running cold and<br />

from heating up during <strong>high</strong> temperature<br />

operation.<br />

We have extend the original range of<br />

two popular laboratory workhorses to a<br />

family of five. The ministat and unistat<br />

cc have been joined by ministat 125, 230<br />

and 240.<br />

Three levels of interchangeable controllers<br />

offers the end-user a choice of<br />

features best suited to the demands of<br />

the application through Huber’s familiar<br />

“Plug and Play” technology. This maintains<br />

the ability for the user to easily upgrade<br />

controllers should the application<br />

demand it.<br />

Accessories see page 19.., 45..


Pressure/ bar<br />

0,8<br />

0,6<br />

0,4<br />

0,2<br />

0<br />

-0,2<br />

-0,4<br />

-0,6<br />

10 20<br />

Flow in l/min<br />

30<br />

Measured with water at 20˚C in accordance to DIN 12876<br />

225 225 mm mm<br />

Option:<br />

Natural<br />

Refrigerants<br />

(Page 50...)<br />

Accessories see page 19.., 45..<br />

370 370 mm mm<br />

360 mm<br />

ompatible<br />

Ministats ontrol Thermostats<br />

Thermostat<br />

255 255 mm mm<br />

450 mm<br />

400 mm<br />

VPC<br />

Variable Pressure<br />

Control<br />

300 300 mm mm<br />

www.huber-online.com · Tel. +49-781-96030<br />

465 mm<br />

455 mm<br />

15


ompatible<br />

ontrol Thermostats<br />

Thermostat<br />

Cooling and heating thermostats to -45°C<br />

Controller Options<br />

305 vpc<br />

Large bath volume<br />

Cooling Thermostats<br />

CC1: CC2: CC3:<br />

Basic and practical External process oriented Automation capable<br />

Please see page 6 for full details.<br />

405 vpc/w 415 vpc/wl, 505 vpc/wl<br />

410wl vpc<br />

Circulators with small volumes especially designed for external<br />

<strong>thermoregulation</strong> applications. Highest cooling power density and<br />

largest volume cooling capacity in their class.<br />

VPC<br />

Variable Pressure<br />

Control<br />

First bath circulator in the<br />

world with an air and water<br />

cooled refrigeration machine.<br />

Bath Depth: 150 mm Bath Depth: 150 mm Bath Depth: 150 mm Bath Depth: 200 mm<br />

Model (previous:) Working Tem- Bath Heating Pump Data Cooling Power [kW] Cat.No. G Price<br />

perature Range Volume Power max. Pressure max. Suction at [°C]<br />

[°C] [ltr] [kW] [l/min] [bar] [l/min] [bar] 100 20 0 -20 -30 -40<br />

CC1-305 vpc (CC130-1) -30..150 20 1,5 33 0,7 22 0,4 0,35 0,35 0,35 0,23 0,03 – 690.0011 2<br />

CC1-405 vpc (CC241-1) -40..200 5 1,5 33 0,7 22 0,4 0,7 0,7 0,7 0,45 0,18 0,03 697.0011 2<br />

CC1-405w vpc (CC241w-1) -40..200 5 1,5 33 0,7 22 0,4 0,7 0,7 0,7 0,45 0,18 0,03 697.0021 2<br />

CC1-415 vpc (CC240-1) -40..200 5 1,5 33 0,7 22 0,4 1,2 1,2 1,0 0,6 0,2 0,05 694.0011 2<br />

CC1-415wl vpc (CC240wl-1) -40..200 5 1,5 33 0,7 22 0,4 1,2 1,2 1,0 0,6 0,2 0,05 694.0021 3<br />

CC1-410wl vpc (CC245wl-1) -45..200 22/8,5* 1,5/4,5 33 0,7 22 0,4 0,8 0,8 0,8 0,5 0,15 0,1 695.0011 3<br />

Plug & Play<br />

3 Years<br />

Warranty<br />

3 controller options * with displacement insert Temperature Stability to DIN 12876: 0,02 K<br />

16 www.huber-online.com · Tel. +49-781-96030<br />

Option:<br />

Natural<br />

Refrigerants<br />

(Page 50...)<br />

Accessories see page 19.., 45..


Cooling and heating thermostats to -55°C<br />

Compact form and large cooling powers at low temperatures<br />

ompatible<br />

Cooling Thermostats ontrol Thermostats<br />

Thermostat<br />

510 vpc/w, 515w vpc 515 vpc, 905 vpc/w 520w vpc, 525w vpc,<br />

810 vpc/w<br />

Bath Depth: 200 mm Bath Depth: 200 mm Bath Depth: 200 mm<br />

Model (previous:) Working Tem- Bath Heating Pump Data Cooling Power [kW] Cat.No. G Price<br />

perature Range Volume Power max. Pressure max. Suction at [°C]<br />

[°C] [ltr] [kW] [l/min] [bar] [l/min] [bar] 100 20 0 -20 -40<br />

CC1-505 vpc (CC250-1) -50..200 5 1,5 33 0,7 22 0,4 1,2 1,2 1,0 0,6 0,15 696.0011 2<br />

CC1-505wl vpc (CC250wl-1) -50..200 5 1,5 33 0,7 22 0,4 1,2 1,2 1,0 0,6 0,15 696.0021 3<br />

CC1-510 vpc (CC150-1) -50..100 18/11* 3,0 31 0,6 24 0,35 2,1 2,1 2,1 1,0 0,4 564.0021 2<br />

CC1-510w vpc (CC150w-1) -50..100 18/11* 3,0 31 0,6 24 0,35 2,4 2,4 2,4 1,0 0,4 564.0031 2<br />

CC1-515 vpc (CC155-1) -55..100 26/15* 3,0 31 0,6 24 0,35 3,3 3,3 3,3 1,6 0,6 651.0011 2<br />

CC1-515w vpc (CC155w-1) -55..100 18/11* 3,0 31 0,6 24 0,35 3,3 3,3 3,3 1,6 0,6 651.0021 2<br />

CC1-520w vpc (CC156w-1) -55..100 17/10* 3,0 31 0,6 24 0,35 5,0 5,0 5,0 3,0 1,5 698.0011 3<br />

CC1-525w vpc (CC157w-1) -55..100 17/10* 3,0 31 0,6 24 0,35 7,0 7,0 5,0 3,0 1,5 700.0001 3<br />

3 controller options * with displacement insert Temperature Stability to DIN 12876: 0,02 K<br />

Accessories see page 19.., 45..<br />

www.huber-online.com · Tel. +49-781-96030<br />

Option:<br />

Natural<br />

Refrigerants<br />

(Page 50...)<br />

17


ompatible<br />

ontrol Thermostats<br />

Thermostat<br />

Cooling and heating thermostats to -90°C<br />

705 vpc, 805 vpc 815 vpc<br />

Lower price alternative to the CC820 vpc for<br />

low temperatures, when low cooling power is<br />

adequate<br />

Bath Depth: 150 mm Bath Depth: 150 mm<br />

Cooling Thermostats<br />

Plug & Play<br />

3 Years<br />

Warranty<br />

VPC<br />

Variable Pressure<br />

Control<br />

Model (previous:) Working Tem- Bath Heating Pump Data Cooling Power [kW] Cat.No. G Price<br />

perature Range Volume Power max. Pressure max. Suction at [°C]<br />

[°C] [ltr] [kW] [l/min] [bar] [l/min] [bar] 100 20 0 -20 -40 -60<br />

CC1-705 vpc (CC175-1) -75..100 5 1,5 33 0,7 22 0,4 0,25 0,25 0,25 0,2 0,15 0,1 692.0011 2<br />

CC1-805 vpc (CC180-1) -80..100 5 1,5 33 0,7 22 0,4 0,5 0,5 0,5 0,4 0,3 0,3 693.0011 2<br />

CC1-820 vpc (CC181-1) -80..100 17/10* 3,0 31 0,6 24 0,35 1,2 1,2 1,2 1,1 0,9 0,6 567.0021 3<br />

CC1-820w vpc (CC181w-1) -80..100 17/10* 3,0 31 0,6 24 0,35 1,2 1,2 1,2 1,1 0,9 0,6 567.0031 3<br />

CC1-815 vpc (CC185-1) -85..100 5 1,5 33 0,7 22 0,4 1,0 1,0 1,0 0,8 0,75 0,6 699.0001 3<br />

CC1-905 vpc (CC190-1) -90..100 26/15* 3,0 31 0,6 24 0,35 2,0 2,0 2,0 1,9 1,7 1,0 568.0011 3<br />

CC1-905w vpc (CC190w-1) -90..100 26/15* 3,0 31 0,6 24 0,35 2,0 2,0 2,0 1,9 1,7 1,0 568.0021 3<br />

3 controller options * with displacement insert Temperature Stability to DIN 12876: 0,02 K<br />

18 www.huber-online.com · Tel. +49-781-96030<br />

Pressure/ bar<br />

Pump Data VPC models<br />

Pressure/ bar<br />

0,8<br />

0,6<br />

0,4<br />

0,2<br />

0<br />

-0,2<br />

-0,4<br />

-0,6<br />

0 10 20 30<br />

Flow in l/min<br />

Measured with water at 20˚C in accordance to DIN 12876<br />

0,8<br />

0,6<br />

0,4<br />

0,2<br />

0<br />

-0,2<br />

-0,4<br />

Option:<br />

-0,6<br />

0 10 20 30<br />

Natural<br />

Refrigerants<br />

(Page 50...)<br />

Flow in l/min<br />

Measured with water at 20˚C in accordance to DIN 12876<br />

Accessories see page 19.., 45..


Flow-through Chillers<br />

The “Flow-through Chillers” are designed for simple, low demand cooling applications.<br />

They are commonly used in combination with the CC202C or CC205B series<br />

to remove heat in order to cool a process back to room temperature.<br />

Model Working Cooling Power [kW] at Dimensions Cat.No. G Price<br />

Temperature Range 0°C -10°C -20°C W x D x H<br />

[°C] [mm]<br />

DC30 -30..50 0,2 0,15 0,07 190x250x360 574.0002 2<br />

DC31 -30..50 0,4 0,35 0,10 250x310x400 575.0002 2<br />

DC32 -30..50 0,6 0,47 0,12 280x340x460 652.0002 2<br />

Immersion Coolers<br />

„Dip“ or „Immersion“ coolers are ideal for simple cooling applications when low<br />

temperatures are required such as vapour traps or for cooling individual flasks.<br />

They are also commonly used to remove heat from the baths in the „A“ and<br />

„B“ series. The units with an “E” have the capability to control the temperature<br />

to a stability of +/- 0,5 K to DIN 12876. All models can be delivered with a flexible<br />

evaporator coil (no extra cost). The model name and Cat.No. get the addition „F“.<br />

Model Working Cooling Power [W] at Dimensions Cat.No. G Price<br />

Temperature Range 0°C -20°C -30°C W x D x H<br />

[°C] [mm]<br />

TC45 -45..100 240 180 100 190x250x360 570.0008 2<br />

TC45E -45..100 240 180 100 190x250x360 570.0009 2<br />

TC50 -50....50 300 260 200 250x310x400 572.0006 2<br />

TC50E -50....50 300 260 200 250x310x400 572.0007 2<br />

TC100 -100..40 150 140 125 280x440x525 573.0007 2<br />

ompatible<br />

Accessories ontrol Thermostats<br />

Thermostat<br />

TC100E -100..40 150 140 125 280x440x525 573.0008 2 TC45E<br />

Polycarbonate Baths<br />

All models are designed to operate up to a maximum temperature of 100°C.<br />

Model Bath Volume Dimensions Bath Depth Cat.No. G Price<br />

[ltr] W x D x H [mm] [mm]<br />

105A (prev.: A5) 5 132x280x161 150 6307 1<br />

106A (prev.: A6) 6 132x380x161 150 6006 1<br />

107A (prev.: A7) 7 132x480x161 150 6007 1<br />

111A (prev.: A11) 11 333x313x166 150 6008 1<br />

118A (prev.: A18) 18 333x473x166 150 6009 1<br />

Insulated Stainless Steel Baths<br />

All models are designed to operate up to a max temperature of 200°C.<br />

Model Bath Volume Dimensions Bath Dimensions Depth Cat.No. G Price<br />

(prev.:) [ltr] W x D x H [mm] W x D x H [mm] [mm]<br />

208B (E8) 8,5 290x350x215 235x295x150 150 6683 1<br />

212B (E12) 12 350x375x215 295x320x150 150 6684 1<br />

215B (E15) 15 350x375x260 295x320x200 200 6012 1<br />

220B (E20) 20 350x555x215 295x500x150 150 6685 1<br />

225B (E25) 25 350x555x260 295x500x200 200 6013 1<br />

118A<br />

106A<br />

Option:<br />

107A<br />

DC30<br />

Natural<br />

Refrigerants<br />

(Page 50...)<br />

www.huber-online.com · Tel. +49-781-96030<br />

105A<br />

111A<br />

Option:<br />

Natural<br />

Refrigerants<br />

(Page 50...)<br />

TC100E<br />

19


ompatible<br />

ontrol Thermostats<br />

Thermostat<br />

K20<br />

K15<br />

K12<br />

Bath Bridges<br />

Accessories<br />

Cold Baths<br />

Featured here are simply „cold baths“<br />

with volumes from 12 to 25 litres.<br />

These can be used in combination with<br />

an immersion heater or simply run at<br />

their lowest achievable temperature for<br />

use as a “plunge pool”.<br />

They are fully constructed from stainless<br />

steel.<br />

Model Temperature Range Bath Bath Bath Opening Cooling Power [kW] at Dimensions Cat.No. G Price<br />

Volume Depth W x D 0°C -10°C -20°C W x D x H<br />

[°C] [ltr] [mm] [mm] [mm]<br />

K12 -20..50(200) 12 150 295x320 0,18 0,1 350x558x215 653.0020 2<br />

K15 -20..50(200) 15 200 295x320 0,2 0,12 350x558x240 645.0021 2<br />

K20 -30..50(200) 20 150 295x500 0,35 0,3 0,21 350x558x370 646.0021 2<br />

K25 -30..50(200) 25 200 295x500 0,35 0,3 0,21 350x558x420 647.0021 2<br />

Model Cat.No. G Price<br />

Polycarbonate bath 105A, 106A, 107A 6309 1<br />

Polycarbonate bath 111A, 118A 6310 1<br />

Stainless steel bath 208B 6303 1<br />

Stainless steel bath 212B, 215B, 220B, 225B 6308 1<br />

Refrigerated bath K12, K15, K20, K25 6311 1<br />

Telescopic bridge for CC1-E to CC3-E extendible up to max. 640 mm 6306 1<br />

Bath Covers for stainless steel and refrigerated baths<br />

Model Cat.No. G Price<br />

Bath cover 208B 6214 1<br />

Bath cover front 212B-225B, K12-K25 6023 1<br />

Bath cover back 220B-225B, K20-K25 6024 1<br />

Bath cover one piece 220B-225B, K20-K25 6025 1<br />

20 litres and larger can be in one or two parts<br />

Adjustable Bases<br />

Available in 3 options<br />

20 www.huber-online.com · Tel. +49-781-96030<br />

Natural<br />

Refrigerants<br />

Model Cat.No. G Price<br />

Adjustable base for 118A 6328 1<br />

Adjustable base for 111A, 212B, 215B, K12, K15 6297 1<br />

Adjustable base for 220B, 225B, K20, K25 6298 1


Polycarbonate test tube racks<br />

for 105A to 107A<br />

Type Holes Immersion Depth [mm] Cat.No. G Price<br />

A 12 x Ø22 50 6028 1<br />

B 20 x Ø17 55 6029 1<br />

C 20 x Ø17 95 6030 1<br />

D 30 x Ø13 45 (Hemolyse) 6031 1<br />

E 6 x Ø30 50 6032 1<br />

F 36 x Ø10 25 (Eppendorf) 6033 1<br />

Stainless Steel test tube racks<br />

for 111A to 118A, 212B to 225B and refrigerated baths K12-K25<br />

Type Holes Immersion Depth [mm] Cat.No. G Price<br />

1 36 x Ø17 100 6037 1<br />

2 45 x Ø13 70 6038 1<br />

3 46 x Ø17 100 6039 1<br />

4 58 x Ø13 70 6040 1<br />

Trolleys<br />

The trolleys make the Compatible Control Thermostats mobile.<br />

Model Cat.No. G Price<br />

K20, K25, CC305 vpc 6334 2<br />

CC705 vpc, CC805 vpc, CC415 vpc, CC505 vpc 6235 2<br />

CC410wl vpc 6295 2<br />

Unipump (pressure booster)<br />

Made of stainless steel for temperatures from -120 to 300°C. To compensate for<br />

the pressure loss in external systems. The Unipump is connected in series with the<br />

pump of the compatible control thermostat and can be controlled via the volt free<br />

contact of the compatible con trol.<br />

Unipump I max. pressure increase Cat.No. G Price<br />

M16x1 [bar]<br />

Unipump I 0,5 527.0001 2<br />

Unipump I 2 stage 1,5 527.0002 2<br />

Control Cable Unipump I / CC (3m) 6222 1<br />

Controller<br />

Controller Cat.No. G Price<br />

Compatible Control Regler CC1 658.0001 1<br />

Compatible Control Regler CC2 658.0002 1<br />

Compatible Control Regler CC3 658.0003 1<br />

Ministat CC1 663.0011 2<br />

Ministat CC2 663.0012 2<br />

Ministat CC3 663.0013 2<br />

ompatible<br />

Accessories ontrol Thermostats<br />

Thermostat<br />

www.huber-online.com · Tel. +49-781-96030<br />

21


ompatible<br />

ontrol Thermostats<br />

External Pt100 sensors<br />

External Pt100 sensors for CC2 and CC3.<br />

For external <strong>thermoregulation</strong> applications,<br />

a range of sensors. Custom models<br />

available on request.<br />

Control cables<br />

Control cables (for CC3) allow remote<br />

control via the RS232, RS485 or the analogue<br />

interfaces (AIF). Open ends allow<br />

flexibility to connect as required.<br />

ComBox<br />

ComBox (NAMUR) with enhanced scope<br />

of functions. The ComBox communicates<br />

with the CC controller via the internal<br />

CAN bus, irrespective of whether the device<br />

is operated with a CC1, CC2 or CC3<br />

controller.<br />

Accessories<br />

Sensors (standard cable length 1,5 m) Cat.No. G Price<br />

Ø 6 mm 180 mm 6138 1<br />

with handle Ø 6 mm 200 mm 6105 1<br />

Ø 8 mm 400 mm 6064 1<br />

mounted in protective pipe Ø 8 mm 170 mm 6205 1<br />

M16x1 sensor for flow or return 6352 1<br />

M16x1 sensor for flow or return double 6353 1<br />

Extension cable Pt100, 3m 6292 1<br />

ComBox Cat.No. G Price<br />

ComBox (NAMUR) Ministate, CC intern 6779 1<br />

Remote control Remote control Cat.No. G Price<br />

Other accessories<br />

6301<br />

6300<br />

6839<br />

6305<br />

6304<br />

22 www.huber-online.com · Tel. +49-781-96030<br />

Control cables Compatible Control Cat.No. G Price<br />

CC RS232 / PC RS232 (3m) 6198 1<br />

CC RS485 / open (3m) 6236 1<br />

CC AIF / POKO open (3m) 6218 1<br />

CC AIF / open (3m) 6320 1<br />

CC complete / open (3m) 6319 1<br />

Y cable PC / AIF 6651 1<br />

15-pole plug (plug only, no cable) 6335 1<br />

for all CC thermostats with controller CC3 6734 1<br />

Other accessories Cat.No. G Price<br />

Holder for TC45(E)-TC100(E) evaporator to be fixed to bath bridge 6022 1<br />

Drain cock with cap 6839 1<br />

Pump adapter for CC1-E to CC3-E, 111A to 118A, 208B to 225B, K12 to K25 6300 1<br />

Pump adapter for 105A to 107A 6304 1<br />

Cooling coil for CC1-E to CC3-E, 111A to 118A, 208B to 225B 6301 1<br />

Cooling coil for 105A to 107A 6305 1<br />

Tripod bar for CC1-E, CC2-E, CC3-E 6302 1<br />

Trolley K20, K25, CC305 vpc 6334 2<br />

Displacement insert for CC205B 6041 1


Calibration inserts<br />

Calibration insert Cat.No. G Price<br />

ministat 125 6806 2<br />

ministat 230 6807 2<br />

ministat 240 6808 2<br />

CC410wl vpc 6294 2<br />

CC505wl vpc - CC520w vpc,<br />

CC810 vpc 6496 2<br />

CC515 vpc, CC905 vpc 6150 2<br />

CC308B vpc 6325 1<br />

CC315B vpc 6126 1<br />

Measuring method<br />

The temperature constancy specified in<br />

the technical data is measured in accordance<br />

as follows:<br />

The sensor of the test thermo meter is<br />

located in the centre of the bath and at<br />

half the overall depth. The preconditioning<br />

time (τ) of the sensor is 5 or 6 seconds<br />

at most. Heating thermostats are<br />

evaluated using water at a tem perature<br />

of 70°C cooling thermo stats using alcohol<br />

at a tem perature of -10°C.<br />

Heating thermostats are opera ted under<br />

load so that a so-called typical cooling<br />

water current has to flow. In cooling<br />

thermostats a load of this kind is generated<br />

by the pump and transmission<br />

due to the temperature diffe rence be-<br />

A<br />

B<br />

ompatible<br />

Accessories ontrol Thermostats<br />

Thermostat<br />

tween the environment and<br />

-10°C. A control sensor with<br />

=5 seconds would be far too<br />

sluggish for a thermostat. We<br />

use sensors with approx. 1.5<br />

seconds. You will therefore<br />

see a greater fluctuation on<br />

the digital actual value display<br />

than corresponds to the<br />

measurement in the centre of<br />

the bath.<br />

Thermostats<br />

as calibration baths<br />

Thermostats are also used as<br />

calibrating baths. However, if<br />

you wish to test tem perature<br />

sensors using a small mass,<br />

for example, the following<br />

may occur:<br />

The calibrating sensor ( = 5 s)<br />

is in the centre of the bath and<br />

shows a fluctu ation of 0.01K.<br />

The test piece A is lo cated directly adjacent<br />

to this, the test piece B is in one<br />

corner of the bath and the test piece C<br />

in the other corner.<br />

The absolute heat capacity of the test object<br />

(the mass) is perhaps less and the<br />

heat transmission (surface times value)<br />

possibly greater than that of the calibrating<br />

sensor, and an unknown temperature<br />

gradient exists in the bath. In this<br />

case each test piece will be exposed to<br />

a different tempera ture fluctuation, but<br />

the silly thing is that this fluctuation<br />

is not known. A standard<br />

thermostat can be a good<br />

calibrating bath if the volume<br />

is large the preconditioning<br />

time of the test piece is great,<br />

and if the temperature gradient<br />

can be incorpo rated in the<br />

testing tole rance.<br />

For <strong>high</strong>er demands, aluminium<br />

car tridges „modelled on<br />

a Swiss cheese“ can be used,<br />

but the better solution for this<br />

is the calibration insert:<br />

Function principle<br />

The thermostat medium at constancy<br />

flows through the heat exchanger (A)<br />

and via the distributor (B) down into the<br />

calibrating bath. Temperature fluctuations<br />

in the thermostat are evened out<br />

in (A) by overlap. The entire system acts<br />

as a calorimeter. There are virtually no<br />

gradients and no delay in the case of<br />

swift ramps. Temperature stability can<br />

be improved by a factor of 5 to 10. The<br />

cali bration baths CAL1 - CAL4 (page 33)<br />

and the UNICAL (page 34) work with the<br />

same principle.<br />

Displacement inserts<br />

Simple options to boost performance<br />

Volume reduction inserts:<br />

– reduce the li quid volume. Reducing the<br />

bath volume reduces the thermal load<br />

and leads to faster ramping times.<br />

– reduce the li quid’s exposed surface area,<br />

which re duces moisture absorption.<br />

– contain the expansion volume HTF and<br />

prevent the bath from overflowing.<br />

Displacement insert Cat.No. G Price<br />

ministat 125 6818 2<br />

ministat 230 6819 2<br />

ministat 240 6820 2<br />

CC410wl vpc 6293 2<br />

CC505wl vpc - CC520w vpc,<br />

CC810 vpc 6049 2<br />

CC515 vpc, CC905 vpc 6050 2<br />

CC308B vpc 6324 1<br />

CC315B vpc 6043 1<br />

www.huber-online.com · Tel. +49-781-96030<br />

23


HUBER SOFTWARE<br />

SpyLight<br />

SpyLight is software for the visualisation<br />

and documentation of process relevant<br />

data. The communication can be via the<br />

RS 232, RS485 or TCP/IP. The installa-tion<br />

is simple. SpyLight requires very little<br />

disk space and is simple to use. The<br />

logged data is displayed against time.<br />

The axes can be scaled as required. The<br />

zoom function allows easy evaluation of<br />

short time frames.<br />

SpyWatch<br />

SpyWatch is based on the SpyLight software<br />

but offers more features. Installation<br />

and operation is identical. SpyWatch<br />

can operate up to 10 channels simulta-<br />

neously. Each channel is independently<br />

documented and the graphic options can<br />

be configured as required. SpyWatch allows<br />

the user to issue the following instructions<br />

to the unit:<br />

– Set point<br />

– Change from jacket to process<br />

temperature<br />

– Start/Stop<br />

Spy-Funktion<br />

for immediate Service<br />

The spy function integrated in both programs<br />

enables simultaneous recording<br />

of machine parameters allowing a simple<br />

diagnosis in the event of a problem.<br />

The data to be displayed can be selected<br />

by the user. Text can be added to every<br />

curve.<br />

Once the curve has been generated<br />

speed support is available. As soon as<br />

our technicians or our service partners<br />

receive your email with the data logging<br />

the situation can be analysed, to establish<br />

if it is a unit or application problem.<br />

Renowned in its worldwide use.<br />

24 www.huber-online.com · Tel. +49-781-96030<br />

Test run with a 20 litre reactor filled with DW Therm<br />

Test run with a 300 watt in a 20 litre reactor filled with DW Therm<br />

Huber Software Cat.No. G Price<br />

SpyLight (1 Channel) 6790 1<br />

SpyWatch (10 Channel) 6791 1<br />

SpyControl (10 Channel) 6792 1<br />

ComBox (NAMUR) Ministate, CC internal 6779 1<br />

ComBox (NAMUR) CC400, CC401 (ext. box) 6789 1<br />

Control cable CC/PC 6198 1<br />

CP RS232/PC RS232 6146 1<br />

Y cable unistat/PC + analogue 6326 1


UNISTATS<br />

Scale-Up<br />

The Unistats cover a temperature of<br />

-120°C to 400°C. They range in cooling<br />

powers from 0,7 to 130 kW and heating<br />

powers from 1,5 kW to 80 kW. A low internal<br />

volume means that this energy is<br />

transmitted to the process (watts/litre<br />

DIN12876). Uniformity in technology<br />

and control throughout the range gives<br />

each scale of application familiarity<br />

unique to the Unistats. They are the system<br />

of choice for kilo labs, process research,<br />

mini-plants and production.


UNISTATS Plug & Play<br />

Why the name „Tango<br />

Technology“?<br />

To perform the Tango dance requires<br />

skilled partners to glide in rhythm and<br />

unity from a tightly held and controlled<br />

posture to another in a rapid and effortless<br />

movement.<br />

The name “Tango” was adopted to reflect<br />

the way in which the Unistats control<br />

the temperature of a process…<br />

…swift change, tight control, minimum<br />

effort.<br />

Safety First<br />

All the Unistats are fitted with an independent<br />

over-temperature protection<br />

device and a circulating fluid monitoring<br />

device. When these devices are activated<br />

the Unistats give a visual and audible<br />

warning and shut down to stand-by<br />

mode.<br />

Unistats are manufactured, tested and<br />

classified to the requirements dictated<br />

by the strict DIN 12876.<br />

High Temperature Cooling<br />

HT cooling means that active cooling<br />

for the process at temperatures up to<br />

400°C is available. This is possible only<br />

because of another unique Unistat feature,<br />

“HT cooling”. “HT” cooling and<br />

mechanical refrigeration work together<br />

to provide the widest working temperature<br />

range in a single unit. The extreme<br />

of this is the “Unistat 420wHT” with a<br />

temperature range that spans 420°K<br />

from -120…300°C.<br />

Differentiating Benefits<br />

Tight thermal control of chemical<br />

reactions<br />

Rapid response to changing thermal<br />

dynamics<br />

No moisture absorption into the<br />

thermal fluid at low temperatures<br />

No oil cracking, oxidisation or discolouring<br />

of thermal fluid<br />

No oil vapours at <strong>high</strong> temperatures<br />

A single fluid to perform <strong>high</strong> and<br />

low temperature chemistry.<br />

(DW-Therm has a temperature<br />

range of -90…200°C when used with<br />

a Unistat)<br />

Extremely low running costs<br />

Extends working temperature range<br />

of thermal fluids<br />

26 www.huber-online.com · Tel. +49-781-96030<br />

Controller Cat.No. G Price<br />

Unistat Control Panel 6139 2<br />

Unistat Control 6107 2


Facts UNISTATS<br />

Unistats … the Concept<br />

… passive components<br />

and the laws of physics…<br />

The Unistat range was first introduced<br />

over 14-years ago. It was and remains<br />

unique in the level of control it gives<br />

to the user and the way in which such<br />

massive cooling and heating powers are<br />

not just generated, but also transferred<br />

to your process.<br />

The Unistat range is designed to give the<br />

operator extremely tight control over the<br />

temperature of a process regardless of<br />

the varying thermal loads generated by<br />

chemical reactions.<br />

The low internal volume ensures that the<br />

cooling and heating power generated by<br />

the machine controls the temperature of<br />

the process … not a large reservoir of<br />

fluid. (Watts/Litre DIN 12876). This allows<br />

rapid changes in temperature and<br />

tight control over the flow of thermal<br />

energy.<br />

The hydraulically sealed fluid system<br />

means no oil vapours or oil cracking at<br />

<strong>high</strong> temperatures and no moisture absorption<br />

at low temperatures. You can<br />

expect far longer life times and extended<br />

temperature ranges from your expensive<br />

thermal fluid with a Unistat.<br />

However, the true engineering triumph<br />

is in the simplicity of the design. In a<br />

standard Unistat … from the smallest<br />

to the largest … there is only one electro-mechanical<br />

valve. The rest is simply<br />

physics and the laws of physics do not<br />

break.<br />

Standard Features<br />

Hydraulically sealed thermal fluid<br />

system<br />

Low internal volume<br />

Process control via external Pt100<br />

Ramp function<br />

Internal programmer<br />

Comprehensive fault diagnostics<br />

Continual self-test<br />

RS232, RS485 and analogue interface<br />

Potential free and programmable<br />

NO/NC contacts (Potential free contacts)<br />

Multifunctional programmable<br />

alarms<br />

Robust stainless steel construction<br />

www.huber-online.com · Tel. +49-781-96030<br />

27


UNISTATS Tango Principle<br />

Tango Technology<br />

and the Unistats<br />

Peter Huber realized the concept of a hydraulically<br />

sealed, low volume thermostat<br />

over 15 years ago. The development of the<br />

first systems (and continuing improvements)<br />

was in partnership with close contacts in the<br />

pharmaceutical industry. Following a period<br />

of Beta testing, “Tango Technology” became<br />

commercially available in the “Unistat” range<br />

of products in 1990.<br />

Tango Technology has been refined and the<br />

Unistats have grown to dominate their field in<br />

a variety of applications.<br />

The latest generation of Unistats have increased<br />

the performance by such large margins<br />

with such massive leaps forward in functionality<br />

and control that we had to re-name them.<br />

The “Nuevo” Unistats bring even faster response,<br />

even tighter control and even greater<br />

efficiencies.<br />

For “internal” applications such as test tubes<br />

or flasks that need to be partially or fully<br />

submersed in the reservoir, an “open-bath”<br />

thermostat is ideal.<br />

Open bath thermostats connected to “external”<br />

applications are clumsy and slow<br />

resulting in poor temperature control of the<br />

application. The large fluid volume and poor<br />

thermal transfer of the heat exchanger coils<br />

immersed in it add up to slow ramping times<br />

and lethargic response to changing thermal<br />

loads such as when a heat generating reaction<br />

takes place.<br />

Open-bath thermostats carry operational disadvantages<br />

that have a direct impact on the<br />

process and more importantly, profits.<br />

The main disadvantages are:<br />

1. The reservoir:<br />

The reservoir serves two functions.<br />

– To contain the thermal fluid<br />

– To allow for the expansion of the thermal<br />

fluid as it heats and cools<br />

The larger the external application the greater<br />

the “tidal flow” as the fluid expands and<br />

contracts and so the bath has to be larger to<br />

contain it.<br />

The total thermal load that the cooling and<br />

heating system must “drive” is made up<br />

(mainly) of the total volume of thermal fluid<br />

+ the process. The larger the bath the less<br />

of the generated power will be spent on the<br />

application.<br />

This phenomenon is expressed in “watts per<br />

litre” (w/l). A simple example that demonstrates<br />

this is a kettle. A two litre kettle with a 1<br />

kW heater will have a w/l ratio of 500 w/l and<br />

will take “time x” to boil. The same kettle with<br />

only 1 litre of water will have a ratio of 1000w/l<br />

and will boil in half the time.<br />

Since the control of a reaction depends on the<br />

speed with which the jacket of the reactor can<br />

be adjusted to initiate and maintain the flow<br />

of thermal energy, a large volume of thermal<br />

fluid acts as effective thermal “slug” which<br />

adversely effects response times.<br />

2. The heat exchange surfaces<br />

Thermal transfer depends greatly on surface<br />

area. This phenomenon is expressed as a ratio<br />

of “watts per square centimetre” (w/cm²). The<br />

28 www.huber-online.com · Tel. +49-781-96030<br />

smaller the surface area the greater this ratio<br />

becomes and the poorer the thermal transfer<br />

becomes. Heat exchangers in the form of coils<br />

have a comparatively small surface area and<br />

so are poor at transferring thermal energy<br />

effectively.<br />

Imagine a sports stadium that holds 50,000<br />

people and it has only one door. Now imagine<br />

if the stadium had open sides. 50,000 people<br />

will be able to transfer are lot quicker through<br />

a larger surface area.<br />

3. Moisture absorption<br />

Water condenses on cold surfaces. At the bath<br />

opening it is seen as condensation but in the<br />

reservoir it condenses on the cold surface and<br />

collects on the evaporator as ice. Since ice is<br />

a good insulator, the growing layer of ice prevents<br />

heat from travelling from the thermal<br />

fluid to the refrigeration system. If the heat<br />

cannot be removed from the thermal fluid, it<br />

cannot be removed from the process.<br />

4. Oil vapours<br />

At elevated temperatures the thermal fluids<br />

give of vapours which condense on laboratory<br />

surfaces. They can also create health and<br />

safety issues and clog HEPA filters. These<br />

vapours also become flammable at temperatures<br />

dependent on the thermal fluids being<br />

used. This limits the operational range of the<br />

thermal fluid.<br />

Tango Technology eliminates all of the above<br />

disadvantages.<br />

The fluid circuit is hydraulically sealed, the expansion<br />

and contraction of the thermal fluid as<br />

it heats and cools is catered for in an “expansion<br />

tank”. This expansion tank is thermally<br />

isolated but mechanically connected to the<br />

circulating fluid system.<br />

This means that no matter what the temperature<br />

is at the process, the fluid in the expansion<br />

tank remains at 2 –3 degrees around room<br />

temperature.<br />

Being hydraulically sealed means that there is<br />

no moisture absorption at low temperatures<br />

and no vapours at <strong>high</strong> temperatures. This has<br />

the effect of widening the operational range of<br />

a thermal fluid. It also means the elimination<br />

of the build up of oily residues in the laboratory.<br />

It is important to note that this is achieved<br />

by using “passive” components and the laws<br />

of physics. Mechanical or electro mechanical<br />

valves have not been employed for safety and<br />

efficiency reasons.<br />

Process control is greatly improved because:<br />

1. There is no “reservoir” in the Unistats. The<br />

volume of the circulating thermal fluid is minimal<br />

(2-4 litres in most Unistats) and so most<br />

of the generated heating and cooling power<br />

is spent at the application.<br />

This is expressed in watts per litre and the<br />

Unistats have the <strong>high</strong>est ratios.<br />

This results in extremely fast ramp times. The<br />

temperature of the jacket can be rapidly adjusted<br />

to initiate and maintain the flow of thermal<br />

energy enabling tight control over the most<br />

dynamic of reactions.<br />

2. Plate heat exchangers are used to transfer<br />

thermal energy much more efficiently. The<br />

characteristic of a plate heat exchanger is to<br />

present a very large surface area within a very<br />

low volume (the sports stadium with no sides<br />

as explained above!)<br />

This is expressed in “watts per square centimetre”<br />

(w/cm²). Because this ratio is so low<br />

Unistats capable of not just generating massive<br />

thermal powers but also of transferring<br />

thermal energy rapidly without damaging the<br />

thermal fluid.<br />

The net effect is a smaller, more compact and<br />

process directed thermostat. Results can be<br />

measured in increased yields, faster process<br />

times and duplication of results.


High Temperature<br />

Thermostats<br />

High-<strong>precision</strong> and space-saving temperature<br />

control up to +400°C. The new<br />

HT thermostats of the Unistat cc400<br />

range set new standards in safety, easy<br />

operation, and rapid, dynamic temperature<br />

control. The Unistat cc401w HT<br />

model features integral stepper motor<br />

to control the HT-Cooling, level protection<br />

and configurable overtemperature<br />

protection. Its minimal internal volume<br />

allows the shortest heat-up times to be<br />

achieved, while at the same time the<br />

maximum expansion tank temperature<br />

is limited to +60°C. The working life and<br />

properties of the thermal fluid are also<br />

protected, by avoiding direct contact<br />

between the hot fluid and atmosphere.<br />

The HT thermostats with controlled HT-<br />

Cooling are suitable for temperature<br />

control applications up to +400°C, e.g.<br />

a double-jacketed reaction vessel (reactor),<br />

and pilot plants, as well as the<br />

semiconductor Industry and <strong>high</strong> temperature<br />

distillation. They are suitable to<br />

maintain a <strong>high</strong> constant temperature,<br />

or to contain an exothermic reaction at<br />

<strong>high</strong> temperature.<br />

Unistats to 400°C<br />

Accessories see page 36, 45..<br />

Models UNISTATS<br />

Model Temperature Range Pump max. Heating Cooling Power [kW] at [°C] Dimensions Cat.No. G Price<br />

[°C] [l/min] [bar] [kW] 400 300 200 100 W x D x H [mm]<br />

unistat cc400-3 75..400 12 0,5 3,0 190x240x635 400.0003 3<br />

unistat cc401-3 50..400 23 0,5 3,0/9,0 285x330x735 400.0023 3<br />

unistat cc401w HT-3 (15) 50..400 23 0,5 3,0/9,0 10,0 10,0 10,0 10,0 285x330x735 400.0033 3<br />

Unistate to 300°C<br />

Model Temperature Range Pump max. Heating Cooling Power [kW] at [°C] Dimensions Cat.No. G Price<br />

[°C] [l/min] [bar] [kW] 400 300 200 100 W x D x H [mm]<br />

unistat T326 (15) 65..300 15 0,5 3,0/6,0 425x220x635 532.0002 3<br />

unistat T326 HT 65..300* 15 0,5 3,0/6,0 3,2 2,3 0,6 425x220x635 531.0002 3<br />

unistat T326w HT (15) 65..300 15 0,5 3,0/6,0 10,0 10,0 6,0 425x220x635 530.0002 3<br />

unistat T327 (15) 65..300 70 1,6 12,0 460x550x1336 525.0002 3<br />

unistat T327w HT (15) 65..300 60 1,6 12,0 10,0 10,0 6,0 460x550x1336 526.0002 3<br />

* The lowest temperature is 15 K above room temperature<br />

Advantages of High Temperature<br />

Thermostats:<br />

Small space required<br />

Low fill-volume<br />

High Pump capacity<br />

Rapid filling of the complete<br />

application efficient with venting<br />

+60°C max. expansion tank temperature<br />

Plug & Play Technology<br />

Simple operation<br />

High level of safety through constant<br />

monitoring<br />

unistat cc400<br />

unistat cc401w HT-3<br />

www.huber-online.com · Tel. +49-781-96030<br />

Plug & Play<br />

3 Years<br />

Warranty<br />

29


UNISTATS Models<br />

It takes two to tango!<br />

Thermo dyna mics and Microelectronics.<br />

Hydrau li-cally sealed, no fumes, no oil<br />

cracking, no moi sture absorption, sea led<br />

expansion vessel for open baths. Tango<br />

and Unistat 360 can be located under the<br />

lab bench and the control panel (Plug &<br />

Play) can be located in the work place<br />

via the adapter cable. These units incorporate<br />

the full range of the vapour<br />

compression technology: sin gle and<br />

multiple stage compression, cas cade, air<br />

and water-cooling. Tem pe ra tu re stability<br />

better than 0,05 K to DIN 12876. Ide al for<br />

scale-up from lab to pro duction. Tan go<br />

and the big-power Unistats are the leading<br />

technology of thermo stats. Please<br />

ask the Tan go Club.<br />

High Technology „CoolNet“<br />

All Unistat refrigeration machines use the<br />

stepper motor control expansion valve<br />

„CoolNet“, manufactured by Huber. This<br />

ensures that optimal performance from the<br />

evaporator is achieved, and the maximum<br />

possible power is obtained. Without the<br />

CoolNet the Unistats could not achieve such<br />

dynamic, performance, control stability and<br />

operational safety.<br />

New! Ex Zone Solutions<br />

There are two solutions for Ex Zone<br />

<strong>thermoregulation</strong> applications. The first<br />

is to work with a standard unit located<br />

in a safe area and an Ex Rated remote<br />

control panel located in the hazardous<br />

zone. The second solution is to locate<br />

a fully Ex Rated unit (pressure encapsulation,<br />

see table below) within the<br />

hazardous zone. Further information is<br />

available on request.<br />

425 425 mm mm<br />

Plug & Play<br />

3 Years<br />

Warranty<br />

New!<br />

Ex Zone<br />

Solutions<br />

Model Cat.No. G Price<br />

EEx p Housing I (for Unistats T327w, 140w, 141w, 150w, 151w, 380w, 385w, 386w, 390w, 420w, 160w, 161w, 162w, 163w) 6967 –<br />

EEx p Housing II (for Unistats 164w, 165w, 290w, 291w and UC160Tw-4) 6968 –<br />

EEx p Housing III (for Unistats 167w, 169w) 6969 –<br />

EEx p Housing IV (for Unistats T326w HT, tango, 340w, 360w) 6970 –<br />

Remote Control Unistat EXi - EEx ib IIC T4 6702 –<br />

EXi Temperature Measurement (Pt100 converter) 6703 –<br />

30 www.huber-online.com · Tel. +49-781-96030<br />

636 636 mm<br />

270 270 mm mm<br />

Accessories see page 36, 45..


Unistats to -55°C<br />

Unistats to -60°C<br />

Unistat Minus<br />

The „Unistat Minus“ models had been specially developed for work at<br />

low temperatures. These low cost alternatives have powerful refrigeration<br />

and „Tango“ technology with the user friendly controller CC3.<br />

They are available either in flat design (FB) or in a tower casing. Typical<br />

applications are pour point apparatus, low temperature calorimetry,<br />

combination chemistry or crystallisations.<br />

Accessories see page 36, 45..<br />

Models UNISTATS<br />

New!<br />

Ex Zone<br />

Solutions<br />

Model Working Temperature Pump max. Heating Cooling Power [kW] at [°C] Dimensions Cat.No. G Price<br />

Range [°C] [l/min] [bar] [kW] 300 200 100 0 -20 -40 W x D x H [mm]<br />

unistat tango -40..200 15 0,5 1,5/3,0 0,7 0,7 0,7 0,4 0,05 425x270x636 534.0003 3<br />

unistat tango HT -40..300 15 0,5 1,5/3.0 3,2 2,3 1,3 0,7 0,4 0,05 425x270x636 533.0003 3<br />

unistat 340 -40..200 20 0,7 1,5/3.0 1,0 1,0 1,0 0,6 0,1 425x300x636 710.0004 3<br />

unistat 340w -40..200 20 0,7 1,5/3.0 1,0 1,0 1,0 0,6 0,1 425x270x636 710.0003 3<br />

unistat 340 HT -40..300 15 0,5 1,5/3.0 3,2 2,3 1,8 1,0 0,6 0,1 425x300x636 711.0003 3<br />

unistat 340w HT -40..300 15 0,5 1,5/3.0 3,5 2,3 1,8 1,0 0,6 0,1 425x300x636 711.0004 3<br />

unistat 140 -40..200 100 1,5 2,0 2,0 2,0 2,5 1,8 0,2 460x550x1336 544.0004 3<br />

unistat 140w -40..200 100 1,5 2,0 2,0 2,0 2,5 1,8 0,2 460x550x1336 545.0004 3<br />

unistat 140w-FB -40..200 100 1,5 2,0 2,0 2,0 2,5 1,8 0,2 920x635x740 545.0004FB 3<br />

unistat 140 HT -40..300 60 1,6 2,0 3,2 2,3 2,7 2,5 1,8 0,2 460x550x1336 712.0001 3<br />

unistat 140w HT -40..300 60 1,6 2,0 3,5 3,0 2,7 2,5 1,8 0,2 460x550x1336 712.0002 3<br />

unistat 141 -40..200 90 1,5 4,0 3,5 3,5 3,5 2,2 0,3 460x550x1336 550.0005 3<br />

unistat 141w -40..200 90 1,5 4,0 3,5 3,5 3,5 2,2 0,2 460x550x1336 551.0005 3<br />

unistat 141w-FB -40..200 70 1,6 4,0 3,0 3,5 3,5 2,2 0,2 920x635x740 551.0005FB 3<br />

unistat 141 HT -40..300 60 1,6 4,0 3,2 4,0 3,5 3,5 2,2 0,3 460x550x1336 713.0003 3<br />

unistat 141w HT -40..300 60 1,6 4,0 3,5 4,0 3,5 3,5 2,2 0,2 460x550x1336 713.0004 3<br />

unistat 150w -50..200 100 1,5 6,0 5,0 5,0 5,0 2,8 0,9 460x550x1336 715.0001 3<br />

unistat 150w HT -50..300 80 1,5 6,0 3,5 6,0 5,5 5,0 2,8 0,9 460x550x1336 716.0001 3<br />

unistat 151w -55..200 60 1,5 6,0 5,0 5,0 6,0 4,2 1,5 540x600x1336 717.0001 3<br />

unistat 151w-FB -55..200 60 1,5 6,0 5,0 5,0 6,0 4,2 1,5 920x635x740 717.0001FB 3<br />

Model Working Temperature Pump max. Heating Cooling Power [kW] at [°C] Dimensions Cat.No. G Price<br />

Range [°C] [l/min] [bar] [kW] 200 100 0 -20 -40 -60 W x D x H [mm]<br />

unistat 160w -60..200 50 1,5 6,0 7,0 7,0 7,0 6,0 3,3 0,8 600x700x1515 552.0005 4<br />

unistat 161w -60..200 50 1,5 12,0 9,0 9,0 9,0 7,0 4,8 1,0 600x700x1515 556.0005 4<br />

unistat 162w -60..200 90 2,5 12,0 12,0 12,0 12,0 12,0 7,0 2,0 700x800x1515 557.0005 4<br />

unistat 163w -60..200 90 2,5 12,0 16,0 16,0 16,0 13,5 8,4 2,2 700x800x1515 559.0004 4<br />

unistat 164w -60..200 110 2,5 24,0 22,0 22,0 20,0 18,0 15,0 5,0 920x1000x1655 719.0001 5<br />

unistat 165w -60..200 110 2,5 24,0 26,0 26,0 25,0 24,0 18,0 6,0 920x1000x1655 720.0001 5<br />

unistat 166w -60..200 100 2,5 30,0 30,0 30,0 30,0 30,0 20,0 6,0 920x1200x1655 723.0001 5<br />

unistat 167w -60..200 100 2,5 36,0 40,0 40,0 40,0 40,0 22,0 7,0 1800x1200x1830 724.0001 5<br />

unistat 169w -60..200 100 2,5 48,0 65,0 65,0 65,0 65,0 38,0 11,0 1800x1200x1830 726.0001 5<br />

unistat 1060w -60..200 100 2,5 96,0 130,0 130,0 130,0 80,0 60,0 20,0 4500x2000x2000 733.0001 5<br />

unistat minus 55w-FB-3<br />

Model Working Temperature Pump max. Heating Cooling Power [kW] at [°C] Dimensions Cat.No. G Price<br />

Range [°C] [l/min] [bar] [kW] 0 -20 -40 -60 -80 W x D x H [mm]<br />

unistat minus 55w-FB-3 -55..50 55 1,6 2,0 6,0 4,2 1,5 920x635x740 717.0106 4<br />

unistat minus 85w-FB-3 -85..50 18 0,7 2,0 2,3 2,3 2,0 1,2 0,2 1200x650x745 549.0105 4<br />

unistat minus 90w-3 -90..50 40 1,5 4,0 5,2 5,0 4,2 2,9 0,75 600x700x1550 554.0112 4<br />

unistat minus 90w-FB-3 -90..50 40 1,5 4,0 5,2 5,0 4,2 2,9 0,75 1500x700x900 554.0109 4<br />

Option:<br />

Natural<br />

Refrigerants<br />

(Page 50...)<br />

www.huber-online.com · Tel. +49-781-96030<br />

31


UNISTATS Models<br />

Option:<br />

Natural<br />

Refrigerants<br />

(Page 50...)<br />

unistat 360<br />

Unistats to -85°C<br />

Unistats to -90°C<br />

unistat 385<br />

Model variations<br />

w: water-cooled refrigeration<br />

HT: with <strong>high</strong> temperature cooler<br />

FB: flat built version<br />

unistat 385w-FB<br />

Model Working Tempera- Pump max. Heating Cooling Power [kW] at [°C] Dimensions Cat.No. G Price<br />

ture Range [°C] [l/min] [bar] [kW] 300 200 100 0 -20 -40 -60 -80 W x D x H [mm]<br />

unistat 360 -75..200 25 0,8 1,5/3,0 0,6 0,6 0,6 0,6 0,3 425x400x720 536.0006 3<br />

unistat 360w -75..200 25 0,8 1,5/3,0 0,6 0,6 0,6 0,6 0,3 425x400x720 536.0005 3<br />

unistat 360 HT -75..300 16 0,8 1,5/3,0 3,2 2,3 1,4 0,6 0,6 0,6 0,3 425x400x720 535.0006 3<br />

unistat 360w HT -75..300 16 0,8 1,5/3,0 3,5 2,3 1,4 0,6 0,6 0,6 0,3 425x400x720 535.0005 3<br />

unistat 380 -80..200 35 0,8 2,0 1,3 1,3 1,3 1,3 0,9 0,2 460x600x1346 539.0006 3<br />

unistat 380w -80..200 35 0,8 2,0 1,5 1,5 1,5 1,5 0,9 0,2 460x600x1346 540.0006 3<br />

unistat 380 HT -80..300 30 0,8 2,0 3,2 2,3 1,8 1,3 1,3 1,3 0,9 0,2 460x600x1346 537.0006 3<br />

unistat 380w HT -80..300 30 0,8 2,0 3,5 2,3 1,8 1,5 1,5 1,5 0,9 0,2 460x600x1346 538.0006 3<br />

unistat 380w HT-FB -80..300 30 0,8 2,0 3,5 2,3 1,8 1,5 1,5 1,5 0,9 0,2 1200x650x740 538.0006FB 3<br />

unistat 385 -85..200 30 0,8 3,0 2,3 2,3 2,3 2,0 1,2 0,3 460x600x1346 548.0006 4<br />

unistat 385w -85..200 30 0,8 3,0 2,3 2,3 2,3 2,0 1,2 0,3 460x600x1346 549.0006 4<br />

unistat 385w-FB -85..200 30 0,8 3,0 2,3 2,3 2,3 2,0 1,2 0,3 1200x650x740 549.0005FB 4<br />

unistat 385 HT -85..300 30 0,8 3,0 3,2 2,3 2,7 2,3 2,3 2,0 1,2 0,3 460x600x1346 546.0006 4<br />

unistat 385w HT -85..300 30 0,8 3,0 3,5 2,3 2,7 2,3 2,3 2,0 1,2 0,3 460x600x1346 547.0006 4<br />

unistat 386 -85..200 32 0,8 3,0 4,0 3,8 3,5 3,5 3,0 2,0 0,6 540x650x1490 721.0002 4<br />

unistat 386w -85..200 32 0,8 3,0 4,0 3,8 3,5 3,5 3,0 2,0 0,6 540x650x1490 722.0002 4<br />

Model Working Tempera- Pump max. Heating Cooling Power [kW] at [°C] Dimensions Cat.No. G Price<br />

ture Range [°C] [l/min] [bar] [kW] 300 200 100 0 -20 -40 -60 -80 W x D x H [mm]<br />

unistat 390w -90..200 40 1,5 6,0 5,2 5,2 5,0 4,2 3,1 0,9 600x700x1560 554.0005 4<br />

unistat 390w HT -90..300 35 1,5 6,0 4,5 2,6 7,0 5,2 5,0 4,2 3,1 0,9 600x700x1560 553.0005 4<br />

unistat 290w -90..200 57 1,3 12,0 16,0 16,0 16,0 16,0 15,0 13,5 3,5 920x1200x1655 558.0003 4<br />

unistat 291w -90..200 80 2,5 24,0 19,0 19,0 19,0 19,0 17,0 15,0 6,0 920x1200x1655 705.0001 5<br />

unistat 292 -90..200 100 2,5 36,0 36,0 30,0 30,0 30,0 28,0 24,0 10,0 1700x3500x1850 706.0001 5<br />

unistat 292w -90..200 100 2,5 36,0 36,0 30,0 30,0 30,0 28,0 24,0 10,0 2400x1200x1750 706.0002 5<br />

32 www.huber-online.com · Tel. +49-781-96030<br />

New!<br />

Ex Zone<br />

Solutions<br />

Accessories see page 36, 45..


Unistats to -120°C<br />

Calibration Baths<br />

Models UNISTATS<br />

unistat 390w<br />

unistat 291w<br />

Model Working Tempera- Pump max. Heating Cooling Power [kW] at [°C] Dimensions Cat.No. G Price<br />

ture Range [°C] [l/min] [bar] [kW] 300 200 100 0 -20 -60 -80 -100 W x D x H [mm]<br />

unistat 420w -120..100 18 0,7 2,0 1,5 1,5 1,5 1,4 1,3 1,0 700x800x1515 543.0004 4<br />

unistat 420w HT -120..300 16 0,7 2,0 3,5 3,2 3,0 1,5 1,5 1,4 1,3 1,0 700x800x1515 541.0004 4<br />

unistat 421w -120..100 44 1,5 4,0 2,5 2,5 2,5 2,5 2,0 2,0 920x1200x1655 707.0001 5<br />

This range of calibration baths are designed<br />

for physically small devices.<br />

– Stability better than 0,02 K<br />

to DIN 12876<br />

– Temperature range: -80…250°C<br />

– Bath depth 400 mm<br />

Model Working Temperature Bath Bath Heating Power Cooling Power [kW] Dimensions Cat.No. G Price<br />

Range Volume [kW] at 0°C W x D x H<br />

[°C] [mm] [ltr] [mm]<br />

CAL1 -20..150 Ø120 x 400 7 1,0 0,3 585x425x550 665.0004 3<br />

CAL2 -40..200 Ø120 x 400 7 1,5 0,5 585x425x550 665.0005 3<br />

CAL3 -80..150 Ø120 x 400 7 1,5 0,3 585x560x550 665.0003 3<br />

CAL4 +25..250 Ø120 x 400 7 1,5 – 585x355x550 665.0006 3<br />

All measurements valid for an ambient temperature of +20°C<br />

Accessories see page 36, 45..<br />

New!<br />

Ex Zone<br />

Solutions<br />

www.huber-online.com · Tel. +49-781-96030<br />

Option:<br />

Natural<br />

Refrigerants<br />

(Page 50...)<br />

33


UNISTATS Specials<br />

UNICAL<br />

Calibration systems<br />

The “Unicals” are range of calibration<br />

baths that are designed to be powered<br />

by the Unistat range.<br />

In this way it is possible to manufacture<br />

very large calibration baths capable of<br />

carrying out calibrations from very low<br />

temperatures to very <strong>high</strong> temperatures.<br />

– Stability better than 0,02 K<br />

to DIN 12876<br />

– Temperature range: -80…250°C<br />

– Very large bath volumes available<br />

for batch calibrations<br />

– Can be customised to suit application<br />

The range of calibration baths grows<br />

continually: Large, round (overflow in<br />

the middle) open baths or rectangular<br />

form com bi ned with quick and precise<br />

Uni stats. Temperature Range: -100 to<br />

300°C.<br />

Model Volume Bath Opening Volts at Dimensions Cat.No. G Price<br />

[ltr] [mm] 50 Hz W x D x H [mm]<br />

UniCAL 1 7 Ø115 x 400 230V 708x365x550 655.0001 3<br />

UniCAL 2 32 Ø500 x 215 230V Ø700x490 655.0002 3<br />

UniCAL 3 23 298 x 395 x 200 230V 520x620x505 655.0003 3<br />

Custom models available<br />

Cover Temperature Range Dimensions Cat.No. G Price Holes Price<br />

Material [°C] D x H [mm] [mm]<br />

Edelstahl -100...+300 Ø 220 x 65 6367 1 Ø4-Ø10<br />

Teflon -100...+200 Ø 220 x 30 6365 1 Ø4-Ø10<br />

Polyethylen -100...+100 Ø 220 x 30 6366 1 Ø4-Ø10<br />

Custom models available<br />

34 www.huber-online.com · Tel. +49-781-96030<br />

Custom Model:<br />

UniCAL 8 with Unistat 161w<br />

Insulated Stainless Steel Cover<br />

Accessories see page 36, 45..


The New Dimension<br />

Touchscreen TFT-Display<br />

Simple to operate<br />

Variable Pressure Control VPC<br />

Non-linear programmable ramping<br />

True Adaptive Control (TAC)<br />

Bench top models -75 ... +250°C<br />

Plug & Play Technology<br />

Natural Refrigerants (Option)<br />

Models and further information available at www.huber-online.com<br />

The proven Unistat Technology (Page 28): The<br />

Unistat Tango Nuevo is a hydraulically sealed<br />

circulator with a fully self contained expansion<br />

tank at atmospheric pressure. This means that<br />

the thermostat is atmospherically sealed and<br />

can be located below or above the level of the<br />

application without the risk of siphoning or<br />

back-flow even during power-down or when in<br />

stand-by status.<br />

UNISTAT NUEVO<br />

Effect (Selectable of True system Adaptive response) Control<br />

Rapid ramping (no overshoot)<br />

The new dimension: Air-cooled or air AND water-cooled<br />

refrigeration system (introduced by<br />

Huber in 1997) with an environmental option<br />

using natural refrigerants. Active mechanical<br />

cooling from -45 up to +250°C. Stronger pump<br />

with soft start to eliminate pressure surges is<br />

fitted. The flow pressure is monitored and fully<br />

controlled by VPC technology. The Unistat Pilot<br />

features a colour TFT display with touch-screen.<br />

Temperature<br />

True Adaptive Control<br />

Setpoint<br />

with TAC<br />

without TAC<br />

Faster ramping (minimal overshoot)<br />

Time Time<br />

Temperature<br />

Setpoint<br />

with TAC<br />

without TAC<br />

Easy to operate, it features an internal programmer,<br />

process control capability and an organically<br />

adaptive, self tuning PID controller. The<br />

advanced controller learns and adapts to changing<br />

application demands … constantly. Accessories<br />

include: PC software for documentation<br />

of process relevant data, diagnostics and PCbased<br />

control: SpyLight, SpyWatch, SpyControl.<br />

www.huber-online.com · Tel. +49-781-96030<br />

35


UNISTATS Accessories<br />

Connections for Mettler<br />

Toledo ‚LabMax‘ and ‚RC1‘<br />

For use with the LabMax or the RC1 in<br />

variations High temp, Mid temp and low<br />

temp, use the adapters listed here.<br />

External Pt100 sensors Sensors (standard cable length 1,5 m) Cat.No. G Price<br />

For external <strong>thermoregulation</strong> appli cations<br />

there are dif fe rent sensors available.<br />

Special ver sions can be made on<br />

request.<br />

Control Cables<br />

Control cable for use with RS232, RS485<br />

or analogue interface (AIF). Control cables<br />

can be configured to request.<br />

Pressure booster pump<br />

Pressure pump of stainless steel for temperatures<br />

from -120 to 300°C. To compensate<br />

for the pressure loss in external systems.<br />

The Uni pump is connected in series<br />

with the pump of the unistat and can be<br />

controlled via the volt free contacts of the<br />

unistat con trol.<br />

Adaptor Quantity Cat.No. G Price<br />

unistat 14x Metal Hose NW20/ M30x1,5:<br />

M30x1,5 AG - 1/2“ female 2x 6394 1<br />

M30x1,5 AG - 3/4“ female 2x 6442 1<br />

M30x1,5 AG - M16x1 female 2x 6431 1<br />

Ø 6 mm 180 mm 6138 1<br />

with handle Ø 6 mm 200 mm 6105 1<br />

Ø 8 mm 400 mm 6064 1<br />

mounted in protective pipe Ø 8 mm 170 mm 6205 1<br />

M16x1 sensor for flow or return 6352 1<br />

M16x1 sensor for flow or return double 6353 1<br />

M30x1,5 sensor for flow or return 6509 1<br />

M30x1,5 sensor for flow or return double 6363 1<br />

Extension cable Pt100, 3m 6292 1<br />

Unipump Pump max. Dimensions Cat.No. G Price<br />

[l/min] [bar] W x D x H [mm]<br />

Unipump I M16x1 23 0,5 170x380x175 527.0001 2<br />

Unipump I 2 stage M16x1 35 1,5 170x380x175 527.0002 2<br />

Unipump II M30x1,5 70 1,5 205x430x290 527.0003 2<br />

Unipump II 2 stage M30x1,5 70 2,5 205x430x290 527.0004 2<br />

Control cable Unipump / unistat (3m) 6221 1<br />

Bypass Bypass Cat.No. G Price<br />

For systems with <strong>high</strong> pressure loss. The<br />

Bypass is connected between the flow<br />

and return and is manually controlled<br />

(stepless).<br />

Unistat, bench top M16x1 6415 1<br />

Unistat, others (non-bench top) M16x1 6416 1<br />

Unistat M30x1,5 6417 1<br />

Unistat 420w M16x1 6418 1<br />

Safety Devices<br />

Float switch in-sight glass, leak mo ni-<br />

Safety Devices Cat.No. G Price<br />

toring (<strong>high</strong>est safety class).<br />

Float Switch 6152 1<br />

Atmospheric sealing kit for sight glass<br />

and expansion vessel, e.g. for inert gas<br />

blanketing.<br />

Sealing Kit 6523 2<br />

Trolleys<br />

The trolleys make the Unistats mobile.<br />

36 www.huber-online.com · Tel. +49-781-96030<br />

Communication cables Control Panel CP (standard cable length 3 m) Cat.No. G Price<br />

from to Note<br />

CP PC RS232 6146 1<br />

CP Unistat controller Extension cable for control panel 6147 1<br />

CP RS485 Cable end open 6279 1<br />

CP Analog Cable end open 6254 1<br />

CP Remote control CC3 6737 1<br />

Y cable unistat/PC + analogue 6326 1<br />

Model Cat.No. G Price<br />

unistat tango, unistat tango HT, 340w 6280 2<br />

unistat T326 6469 2<br />

unistat 360, 360w, 360 HT, 360w HT 6263 2<br />

unistat 340, 340 HT, 340w HT 6630 2


Controller Cat.No. G Price<br />

CC1 658.0001 1<br />

CC2 658.0002 1<br />

CC3 658.0003 1<br />

Unistat Control Panel 6139 2<br />

Unistat Control 6107 2<br />

Facts UNICHILLERS<br />

Differentiating Features<br />

Simple to use<br />

Robustly reliable and innovative refrigeration<br />

system<br />

Bright LED level display…can easily be read<br />

from long distances<br />

Powerful pumps for demanding applications<br />

Frame and casing manufactured from<br />

stainless steel<br />

Industrial strength resists work-place abuse<br />

Efficient energy management lowers resource<br />

consumption<br />

Tower design consumes less floor space<br />

CC1, CC2 and CC3 controllers for operational<br />

uniformity<br />

Water-cooled and air-cooled versions available<br />

Lifting lugs fitted to aid location


38<br />

UNICHILLER Bench Top<br />

Features<br />

Operation<br />

Simple menu driven control<br />

LCD for good view<br />

LCD for set point/actual temperature,<br />

operating conditions, set<br />

point limits, service information<br />

Dialogue<br />

digital interface RS232, RS485,<br />

analogue interface 4 - 20 mA<br />

(not CC1 and CC2)<br />

Cascade Control<br />

Connection for external<br />

Pt100 sensor (not CC1)<br />

Software<br />

Windows-software for documentation<br />

and visualization. Free Software<br />

updates are guaranteed!<br />

New Minichillers<br />

The minichiller is an incredibly compact<br />

chiller that packs a cooling punch<br />

beyond its size. Compact, robust and<br />

powerful, now in stainless<br />

steel casing. There<br />

are four controller<br />

options, the simplest<br />

option does not offer<br />

the unique advantages<br />

of Plug & Play technology.<br />

The CC1 to CC3<br />

options with the superior<br />

funtionality do have<br />

these benefits. The<br />

cooling performance<br />

is the same irrespective<br />

of the controller.<br />

Unichiller (bench top)<br />

Unichillers are intelligent circulation<br />

coolers in the low-priced, classic desktop<br />

housing.<br />

Typical is the flat construction with a<br />

footprint which orientates itself by the<br />

depth of the desk. The more power ful<br />

models beginning from UC015 fit under<br />

the working bench. All Unichillers work<br />

with the interchangeable CC con trollers.<br />

With the help of a remote kit the controller<br />

can be sepa rated from the Unichiller.<br />

All Uni chillers have an automatic power<br />

adjust ment and can be factory-fitted<br />

with a heating.<br />

UC006A-2<br />

Model Working Temperature Pump max. Cooling Power [kW] at [°C] Dimensions mobile Cat.No. G Price<br />

Range [°C] [l/min] [bar] 15 0 -10 W x D x H [mm] with roller<br />

minichiller -20...40 12 0,2 0,3 0,2 0,14 225x360x380 – 466.0010 2<br />

minichiller w -20...40 12 0,2 0,3 0,2 0,14 225x360x380 – 466.0020 2<br />

minichiller-1* -20...40 12 0,2 0,3 0,2 0,14 225x360x380 – 466.0011 2<br />

minichiller w-1* -20...40 12 0,2 0,3 0,2 0,14 225x360x380 – 466.0021 2<br />

UC006A-1* -20...40 18 0,5 0,6 0,5 0,22 277x500x425 – 576.0031 3<br />

UC007 -20...40 22 3,0 0,7 0,55 0,35 320x500x493 – 576.0050 3<br />

UC007-1* -20...40 22 3,0 0,7 0,55 0,35 320x500x493 – 576.0051 3<br />

UC015-1* -10...40 25 3,0 1,5 1,0 0,4 410x480x540 height: 610 677.0021 3<br />

UC015w-1* -10...40 25 3,0 1,5 1,0 0,4 410x480x540 height: 610 677.0031 3<br />

UC022-1* -10...40 25 3,0 2,2 1,6 1,0 460x510x755 incl. 670.0031 3<br />

UC022w-1* -10...40 25 3,0 2,2 1,6 1,0 460x510x755 incl. 670.0041 3<br />

UC020-1* -10...40 25 3,0 2,0 2,0 1,3 460x510x755 incl. 672.0031 3<br />

UC020w-1* -10...40 25 3,0 2,0 2,0 1,3 460x510x755 incl. 672.0041 3<br />

UC025-1* -10...40 25 3,0 2,5 2,0 1,2 460x615x755 incl. 674.0041 3<br />

UC025w-1* -10...40 25 3,0 2,5 2,0 1,2 460x510x755 incl. 674.0051 3<br />

* 3 controller options Option heating for minichiller-x 1 kW, for UC models 2 kW<br />

www.huber-online.com · Tel. +49-781-96030<br />

Programmer<br />

cc2 up to 5 steps<br />

cc3 50 steps divisible in<br />

10 programs<br />

from 10 kW:<br />

9 programs with 30 steps<br />

Self Diagnostic<br />

Automatically after switch on<br />

Multifunctional Alarm<br />

visual and audio, adjustable alarm<br />

values volt free contact programmable<br />

(not cc1 and cc2)<br />

Calibrateable<br />

Internal and external Pt100 sensor<br />

calibrated through offset correction.<br />

Mains Failure Programmable<br />

Option to switch the thermostat off<br />

in the event of mains failure or auto<br />

restart on reinstatement of electrical<br />

supply.<br />

Fault Diagnosis<br />

Flow-control<br />

Over- and undertemperature control<br />

overheating protection<br />

for units from 10 kW on remote<br />

maintenance via modem<br />

constant memory for the logging<br />

of the unit’s state<br />

Autostart<br />

Date/time and after mains failure<br />

(from 10 kW)<br />

Option:<br />

Accessories see page 43, 45..<br />

UC015-3<br />

Natural<br />

Refrigerants<br />

(Page 50...)


Plug & Play<br />

3 Years<br />

Warranty<br />

Plug & Play UNICHILLERS<br />

New Look:<br />

Unichiller in<br />

Tower Casings<br />

Unichillers.<br />

0,6 kW…100 kW @ 15°C<br />

The smaller Unichillers consume<br />

minimum floor space<br />

with the new tower construction.<br />

High cooling powers are<br />

matched with low volume<br />

(to DIN 12876) in typical<br />

HUBER style so that <strong>high</strong><br />

cooling powers does not<br />

mean sacrificing valuable<br />

laboratory floor space.<br />

New: to save power and reduce<br />

noise, the chillers are<br />

fitted with condensor fans<br />

that vary their speed according<br />

to the load conditions.<br />

Familiar HUBER flexibility is<br />

brought via the “CC” choice<br />

of interchangeable/upgradeable<br />

controllers.<br />

Controller Options<br />

UC006Tw-3<br />

Controller CC1 – Basic and practical<br />

New…User and Administrator levels<br />

New…Digital encoder “turn to search -<br />

push to select”<br />

New…48 character, 4-line LCD display<br />

New…Full character user menu<br />

Visual and audible alarms<br />

Also includes programmable alarm functions<br />

Microprocessor based controller ... and more.<br />

Controller CC2 – External process oriented<br />

All that the CC1 is furnished with plus<br />

Process control capability, Ramping function,<br />

5-step internal programmer ... and more.<br />

Controller CC3 – Automation capable<br />

All that the CC2 is furnished with plus<br />

10-program, 50 step internal programmer<br />

RS232, RS485 and analogue interfaces<br />

... and more.<br />

www.huber-online.com · Tel. +49-781-96030<br />

39


UNICHILLERS in Tower Casings<br />

Unichillers (air cooled bench models)<br />

Model Working Tempera- Pump max. Cooling Power [kW] at [°C] Dimensions [W/dm³] at Cat.No. G Price<br />

ture Range [°C] Type [l/min] [bar] 15 0 -10 -20 W x D x H [mm] 15°C 0°C<br />

UC006T-1* -25..40 A 30 0,7 0,6 0,45 0,25 0,07 350x310x615 9,0 6,7 582.0011 3<br />

UC009T-1* -25..40 A 30 0,7 0,9 0,7 0,48 0,25 350x310x615 13,5 10,5 584.0011 3<br />

UC012T-1* -25..40 A 30 0,7 1,2 1,0 0,7 0,4 350x310x615 18,0 15,0 586.0011 3<br />

* 3 controller options Option heating 2 kW to 100°C<br />

Controller Options<br />

CC1: CC2: CC3:<br />

Basic and practical External process oriented Automation capable<br />

Please see page 37 for full details.<br />

Option:<br />

Natural<br />

Refrigerants<br />

(Page 50...)<br />

UC012T-1 UC016T-3<br />

UC055T-2<br />

Unichillers (air cooled)<br />

Model Working Tempera- Pump max. Cooling Power [kW] at [°C] Dimensions [W/dm³] at Cat.No. G Price<br />

ture Range [°C] Type [l/min] [bar] 15 0 -10 -20 W x D x H [mm] 15°C 0°C<br />

UC016T-1* -10..40 B 22 3,0 1,7 0,9 0,4 - 450x510x1160 6,4 3,4 587.0011 3<br />

UC020T-1* -20..40 B 22 3,0 2,0 2,0 1,3 0,5 450x510x1160 7,5 7,5 588.0011 3<br />

UC025T-1* -10..40 B 22 3,0 2,5 1,2 0,6 - 450x510x1160 9,4 4,5 589.0011 3<br />

UC040T-1* -10..40 B 22 3,0 4,0 2,2 1,0 - 500x550x1265 11,5 6,3 590.0011 3<br />

UC045T-1* -20..40 B 22 3,0 4,5 4,3 2,9 1,5 500x550x1265 12,9 12,4 591.0011 3<br />

UC055T-1* -10..40 C3 65 4,0 5,5 3,0 1,3 - 600x630x1570 9,3 5,1 592.0011 3<br />

UC060T-1* -20..40 C3 65 4,0 6,0 6,0 3,9 1,5 600x630x1570 10,1 10,1 593.0011 3<br />

UC080T-1* -10..40 C3 65 4,0 8,0 4,8 2,5 - 600x730x1570 11,6 7,0 594.0011 3<br />

UC100T-4 -20..40 C3 65 4,0 10,0 10,0 6,5 2,5 600x790x1570 13,4 13,4 595.0006 4<br />

UC110T-4 -10..40 C3 65 4,0 11,0 6,0 2,7 - 600x790x1570 14,8 8,1 596.0006 4<br />

UC130T-4** -10..40 C3 65 4,0 13,0 7,2 3,2 - 874x1185x1870 6,7 3,7 597.0006 4<br />

UC150T-4** -20..40 D3 140 4,0 15,0 15,0 9,7 3,7 874x1485x1870 6,2 6,2 598.0005 4<br />

UC160T-4** -10..40 D3 140 4,0 16,0 8,8 4,0 - 874x1185x1870 8,3 4,5 600.0005 4<br />

UC200T-4** -10..40 D3 140 4,0 20,0 11,0 5,0 - 874x1485x1870 8,2 4,5 601.0005 4<br />

UC210T-4** -20..40 D3 140 4,0 21,0 21,0 13,6 5,2 874x1985x1870 6,5 6,5 602.0005 4<br />

UC250T-4** -10..40 D3 140 4,0 25,0 14,0 6,2 - 874x1985x1870 7,7 4,3 603.0005 5<br />

UC260T-4** -20..40 D3 140 4,0 26,0 26,0 13,6 5,2 874x1985x1870 8,0 8,0 604.0005 5<br />

UC300T-4** -10..40 D3 140 4,0 30,0 16,5 7,5 - 874x1985x1870 9,2 5,1 605.0005 5<br />

UC400T-4** -10..40 D3 140 4,0 40,0 22,0 10,0 - 2500x1685x1800 5,3 2,9 650.0005 5<br />

* 3 controller options ** without trolley Option heating 2 kW to 100°C Dimension may vary slightly<br />

40 www.huber-online.com · Tel. +49-781-96030<br />

Accessories see page 43, 45..


Unichillers (water cooled bench models)<br />

Heating Option<br />

All models (except UC006Tw and UC009Tw)<br />

can be factory-fitted with a heating. The temperature<br />

range is ex ten ded to +100°C. Please<br />

ask for the additional price for the heating.<br />

The model name and Order No. get the addition<br />

“H”. Increased heating powers available<br />

on request.<br />

in Tower Casings UNICHILLERS<br />

Model Working Tempera- Pump max. Cooling Power [kW] at [°C] Dimensions [W/dm³] at Cat.No. G Price<br />

ture Range [°C] Type [l/min] [bar] 15 0 -10 -20 W x D x H [mm] 15°C 0°C<br />

UC006Tw-1* -20..40 A 30 0,7 0,6 0,45 0,4 0,25 230x280x550 16,9 12,7 606.0031 3<br />

UC009Tw-1* -25..40 A 30 0,7 0,9 0,7 0,4 0,2 230x280x550 25,4 22,6 607.0031 3<br />

UC012Tw-1* -25..40 A 30 0,7 1,2 1,0 0,6 0,3 350x310x615 18,0 15,0 611.0011 3<br />

UC015Tw-1* -25..40 A 30 0,7 1,5 1,2 0,8 0,4 350x310x615 22,5 18,0 613.0011 3<br />

UC023Tw-1* -25..40 A 30 0,7 2,3 1,6 0,9 0,5 350x310x615 34,5 24,0 615.0011 3<br />

* 3 controller options Option heating 2 kW to 100°C, except UC006Tw and UC009Tw<br />

UC006Tw-3 UC012Tw-3 UC055Tw-1 UC100Tw-4<br />

Unichillers (water cooled)<br />

Model Working Tempera- Pump max. Cooling Power [kW] at [°C] Dimensions [W/dm³] at Cat.No. G Price<br />

ture Range [°C] Type [l/min] [bar] 15 0 -10 -20 W x D x H [mm] 15°C 0°C<br />

UC016Tw-1* -10..40 B 22 3,0 1,7 0,9 0,4 - 400x440x1100 8,8 4,6 616.0011 3<br />

UC020Tw-1* -20..40 B 22 3,0 2,0 2,0 1,3 0,5 400x440x1100 10,3 10,3 617.0011 3<br />

UC025Tw-1* -10..40 B 22 3,0 2,5 1,2 0,6 - 400x440x1100 12,9 6,2 618.0011 3<br />

UC030Tw-1* -20..40 B 22 3,0 3,0 3,0 2,0 1,0 400x440x1100 15,5 15,5 619.0011 3<br />

UC040Tw-1* -10..40 B 22 3,0 4,0 2,1 0,95 - 400x440x1100 20,7 10,8 620.0011 3<br />

UC055Tw-1* -10..40 C3 65 4,0 5,5 4,0 2,0 - 500x550x1265 15,8 11,5 621.0011 3<br />

UC060Tw-1* -20..40 C3 65 4,0 6,0 6,0 3,8 1,4 500x550x1265 17,2 17,2 622.0011 3<br />

UC080Tw-1* -10..40 C3 65 4,0 8,0 4,65 2,35 - 500x550x1265 23,0 13,4 623.0011 3<br />

UC100Tw-4 -20..40 C3 65 4,0 10,0 10,0 6,3 3,0 600x600x1450 19,2 19,2 624.0005 4<br />

UC110Tw-4 -10..40 C3 65 4,0 11,0 5,8 2,55 - 600x600x1450 21,1 11,1 625.0005 4<br />

UC130Tw-4 -10..40 C3 65 4,0 13,0 7,0 3,0 - 600x600x1450 24,9 13,4 626.0005 4<br />

UC150Tw-4 -20..40 D3 140 4,0 15,0 15,0 10,0 5,0 760x800x1560 15,8 15,8 627.0005 4<br />

UC160Tw-4 -10..40 D3 140 4,0 16,0 9,5 5,5 - 600x600x1450 30,7 18,2 628.0005 4<br />

UC200Tw-4 -10..40 D3 140 4,0 20,0 10,7 4,7 - 760x800x1560 21,1 11,3 629.0005 4<br />

UC210Tw-4 -20..40 D3 140 4,0 21,0 21,0 16,5 10,0 760x800x1560 22,1 22,1 630.0007 4<br />

UC250Tw-4 -10..40 D3 140 4,0 25,0 13,6 5,8 - 760x800x1560 26,4 14,3 631.0005 5<br />

UC260Tw-4 -20..40 D3 140 4,0 26,0 26,0 20,0 12,0 760x800x1560 27,4 27,4 632.0005 5<br />

UC300Tw-4** -10..40 D3 140 4,0 30,0 16,0 7,1 - 760x800x1560 31,6 16,9 633.0005 5<br />

UC400Tw-4** -10..40 D3 140 4,0 40,0 21,0 10,0 - 1000x920x1665 26,1 13,7 634.0005 5<br />

UC500Tw-4** -10..40 D3 140 4,0 50,0 26,0 - - 1000x920x1665 32,6 17,0 635.0005 5<br />

* 3 controller options ** without trolley Option heating 2 kW to 100°C Dimension may vary slightly<br />

Accessories see page 43, 45..<br />

www.huber-online.com · Tel. +49-781-96030<br />

Option:<br />

Natural<br />

Refrigerants<br />

(Page 50...)<br />

41


42<br />

UNICHILLERS Specials<br />

ROTACOOL – a Co-product<br />

Unichiller ETH<br />

Unichillers are intelligent circulation<br />

coolers which have been specially designed<br />

to operate under the workbench<br />

and in general to be connected to an<br />

air-extract duct. The refrigeration unit is<br />

a development, in terms of thermodynamics,<br />

of the unique Unistat Tan go unit.<br />

The term Unichiller indicates that it is universally<br />

suitable for heat dissipation.<br />

Air-cooled refrigeration units which operate<br />

under the workbench or in similarly<br />

con fined areas usually cause heat<br />

to accumu late. Integrated Unichillers are<br />

both air- and water-cooled. The waste<br />

heat can therefore be removed either<br />

using air or cooling water, as desired.<br />

The unit will automati cally switch to water-cooled<br />

operation if the cooling-water<br />

supply is connected. The unit will automatically<br />

switch to air-cooled operation<br />

if the water is not connected or if there<br />

is no cooling-water supply.<br />

Model Working Temperature Cooling Power [kW] at [°C] Pump max. Dimensions Cat.No. G Price<br />

Range [°C] 15 0 -10 [l/min] [bar] W x D x H [mm]<br />

Unichiller ETH-1 wl -10..40 2,5 2,0 1,2 30 1,4 460x615x760 673.0011 3<br />

Unichiller ETH-2 wl -10..40 2,5 2,0 1,2 30 1,4 460x615x760 673.0012 3<br />

Unichiller ETH-3 wl -10..40 2,5 2,0 1,2 30 1,4 460x615x760 673.0013 3<br />

The „Rotacool“ is a product co-developed<br />

with Heidolph to provide a dedicated<br />

cooling service to small bench top<br />

Rotary Evaporators.<br />

Benefits are:<br />

– Independent cooling for individual<br />

rotary evaporators<br />

– Non-reliance on un-predictable<br />

house water supplies<br />

– Consumes no additional bench space,<br />

the rotary evaporator sits on top<br />

– Compact and powerful<br />

Also available from:<br />

Heidolph Instruments GmbH & Co. KG<br />

Walpersdorferstrasse 12, D-91126 Schwabach<br />

Tel. 09122-9920-69<br />

E-Mail: Heidolph.Instruments@Heidolph.de<br />

Internet: www.heidolph.com<br />

From a customer in New Zealand „…I’ve had<br />

a regular trickle of inquisitive people into the<br />

lab to view the Rotacool. I ran it with DCM and<br />

our house vacuum. Using 200 ml in the flask,<br />

I normally recover less than 50 ml. With the<br />

Rotacool down at -10 I got 175 ml and with it<br />

starting off at -20 I got 195 ml back so it does a<br />

superb job of saving our vacuum system“.<br />

Model Working Temperature Cooling Power [kW] at [°C] Pump max. Dimensions Cat.No. G Price<br />

Range [°C] 15 0 -10 [l/min] [bar] W x D x H [mm]<br />

RotaCool -20..40 0,42 0,35 0,22 10 0,2 470x580x420 659.0001 3<br />

www.huber-online.com · Tel. +49-781-96030<br />

Option:<br />

Natural<br />

Refrigerants<br />

(Page 50...)<br />

Option:<br />

Natural<br />

Refrigerants<br />

(Page 50...)<br />

Accessories see page 43, 45..


Pump Pump duty [l/min] at [bar]<br />

0,2 0,5 1,0 2,0 2,5 3,0 4,0<br />

A 20 10 – – – – –<br />

B* 22 20 17 10 – 5 –<br />

B1* – 40 35 28 24 20 10<br />

C3** – – 65 60 45 40 25<br />

C4* ** – – 80 75 75 60 30<br />

D3** – – 140 120 110 90 50<br />

*Stronger pump options available from UC006T and UC012Tw and above ** Pump suitable for UC055 and above<br />

Pump Reduction in cooling power Price<br />

B for A 150 W<br />

B1 for B 150 W<br />

C4 for C3 400 W<br />

D3 for C3 750 W<br />

D3 for C4 350 W<br />

Ocassionally it might be necessarry to increase the unit housing to the next bigger size.<br />

Sensors (standard cable length 1,5 m) Cat.No. G Price<br />

Ø 6 mm 180 mm 6138 1<br />

with handle Ø 6 mm 200 mm 6105 1<br />

Ø 8 mm 400 mm 6064 1<br />

mounted in protective pipe Ø 8 mm 170 mm 6205 1<br />

M16x1 sensor for flow or return 6352 1<br />

M16x1 sensor for flow or return double 6353 1<br />

M30x1,5 sensor for flow or return 6509 1<br />

M30x1,5 sensor for flow or return double 6363 1<br />

Extension cable Pt100, 3m 6292 1<br />

Control cables Compatible Control Cat.No. G Price<br />

CC RS232 / PC RS232 (3m) 6198 1<br />

CC RS485 / open (3m) 6236 1<br />

CC AIF / POKO open (3m) 6218 1<br />

CC AIF / open (3m) 6320 1<br />

CC complete / open (3m) 6319 1<br />

Y cable PC / AIF 6651 1<br />

15-pole plug (plug only, no cable) 6335 1<br />

Communication cables Control Panel CP (standard cable length 3 m) Cat.No. G Price<br />

from to Note<br />

CP PC RS232 6146 1<br />

CP Unistat controller Extension cable for control panel 6147 1<br />

CP RS485 Cable end open 6279 1<br />

CP Analog Cable end open 6254 1<br />

CP Remote control CC3 6737 1<br />

Y cable unistat/PC + analogue 6326 1<br />

Other accessories Cat.No. G Price<br />

Float switch 6173 1<br />

Trolley UC015 6235 2<br />

Weather resistant option on request<br />

Accessories UNICHILLERS<br />

Pumps<br />

Instead of the standard pump you can<br />

get stronger pumps for systems with a<br />

<strong>high</strong>er pressure drop.<br />

The bench top models with standard<br />

pump A are for external closed systems<br />

only. The air-cooled models UC006T to<br />

UC012T and the water-cooled models<br />

UC012Tw to UC023Tw (not UC006Tw<br />

and UC009Tw) are also available with a<br />

stronger pump B which allows the temperature<br />

control of open baths and closed<br />

systems. Model names and Cat.No. will<br />

then get the additional induction ‚B‘<br />

(e.g. UC012Tw-3 B, Cat.No. 611.0013B).<br />

External Pt100 sensors<br />

For external <strong>thermoregulation</strong> applications<br />

there are different sensors available.<br />

Special versions can be made on<br />

request.<br />

Control cables for use with<br />

CC controllers<br />

Control cables (for CC3) allow remote<br />

control via the RS232, RS485 or the analogue<br />

interfaces (AIF). Open ends allow<br />

flexibility to connect as required.<br />

Control cables for use with<br />

Unistat Control<br />

Control cable for use with RS232, RS485<br />

or analogue interface (AIF). Control cables<br />

can be configured to request.<br />

Other accessories<br />

www.huber-online.com · Tel. +49-781-96030<br />

43


SPECIALS Models<br />

Hotbox<br />

HOTBOX – really hot units are the new,<br />

compact recircu lators to maintain the<br />

temperature of externally open systems.<br />

Safety first: The safety standards of industry<br />

and research are reached with an<br />

adjustable overheat protection and level<br />

protection (pressure switch). Casing and<br />

pump made of stainless steel. HB2-HB5<br />

with swirl ca s tors. The temperature is<br />

controlled with the exchan ge able microprocessor<br />

controllers CC1, CC2 or CC3<br />

with 3 years warranty.<br />

Controller Options<br />

CC1: CC2: CC3:<br />

Basic and practical External process oriented Automation capable<br />

Please see page 37 for full details.<br />

Beer „Force Ageing“<br />

Thermostats<br />

We offer a special air- or water chilled<br />

chiller unit for the Beer Forcier-Test. Both<br />

models are equipped with a comfortable<br />

programmer for the usual change between<br />

0°C and 60°C in the usual 24 hour<br />

cycle. The BFT 2 is for 20 bottles in the<br />

original Eurobox.<br />

The CFC free units comply with the safety<br />

class FL, III. Ca sings and bath parts are<br />

made of Stainless steel.<br />

HB1-3<br />

HB5-3<br />

Model Working Tempera- Pump Connections Heating Power Dimensions Cat.No. G Price<br />

ture Range [°C] [l/min] [bar] [kW] W x D x H [mm]<br />

Hotbox HB1 -1 45..250 M16x1 18 at 0,5 4,5 180x430x360 290.0051 3<br />

Hotbox HB2 -1 60..250 M16x1 25 at 0,5 6,0 455x320x500 290.0061 3<br />

Hotbox HB3 -1 60..250 M30x1,5 50 at 0,5 6,0 455x320x500 290.0071 3<br />

Hotbox HB4 -1 60..250 M30x1,5 50 at 0,5 12,0 455x320x500 290.0081 3<br />

Hotbox HB5 -1 60..250 M30x1,5 56 at 0,5 12,0 455x320x500 290.0091 3<br />

3 controller options<br />

BFT1-2 BFT2w-2<br />

Model Working Tempera- Bath Opening Bath Depth Heating Power Cooling Power Dimensions Cat.No. G Price<br />

ture Range W x D at 20°C W x D x H<br />

[°C] [mm] [mm] [kW] [kW] [mm]<br />

BFT 1-2 0..80 280x280 150 2,0 1,0 420x590x700 569.0005 2<br />

BFT 1w-2 0..80 280x280 150 2,0 1,0 420x590x700 569.0006 2<br />

BFT 2-2 0..80 530x400 360 3,0 2,5 670x720x1070 249.0005 2<br />

BFT 2w-2 0..80 530x400 360 3,0 2,5 670x720x1070 249.0006 2<br />

BFT 4-2 0..80 300x400 300 2,0 0,35 540x600x775 414.0001 2<br />

also available with controller CC3<br />

44 www.huber-online.com · Tel. +49-781-96030<br />

Option:<br />

Natural<br />

Refrigerants<br />

(Page 50...)<br />

Accessories see page 45..


DW-Therm -90°C...+200°C<br />

Specifications<br />

Appearance and odour: transparent, colourless or yellow<br />

liquid with characteristic odour<br />

Silane content: 99%<br />

Viscosity: 2,0-2,2 mm²/sec at 20°C<br />

Density: 0,88 g/cm³ at 15°C<br />

Boiling range: 228-235°C<br />

Solidification at: -137°C<br />

Flash point: 101°C<br />

Ignition temperature: 265°C<br />

Properties<br />

DW-Therm is a mixture of isometric triethoxysilanes and has<br />

been developed for hydraulically sealed systems.<br />

Notes<br />

– broad working range from -90°C to +200°C (hydraulically<br />

sealed systems)<br />

– excellent thermooxidative stability at <strong>high</strong> temperatures<br />

– low viscosity at low temperatures<br />

– low volatility and pleasant odour<br />

– easy handling (no creeping like silicone oils)<br />

– good compatibility with silicone oils<br />

– insoluble in water and environmentally friendly<br />

– no known toxicity<br />

DW-Therm HT +20°C...+330°C<br />

Specifications<br />

Appearance: clear, orange coloured liquid<br />

Content: 99,5% partially hydrogenated<br />

terphenyls<br />

kinematic viscosity: 101 mm²/sec at 20°C<br />

Density: 1,004 g/cm³ at 20°C<br />

Boiling starts at: approx. 350°C<br />

Pour point: -33°C<br />

Flash point: approx. 190°C<br />

Ignition temperature: approx. 390°C<br />

Properties<br />

DW-Therm HT is a mixture of partially hydrogenated terphenyls.<br />

It is especially suited for <strong>high</strong> temperature applications<br />

using hydraulically sealed thermostats.<br />

Notes<br />

– broad working range from +20°C to +330°C<br />

(hydraulically sealed system)<br />

– long lifetime at <strong>high</strong> temperatures under inert atmosphere:<br />

3-4 years<br />

– good thermal properties for heat transfer<br />

– <strong>high</strong> oxidation stability<br />

– not classified as dangerous goods, no known toxicity<br />

More information available at www.dws-synthese.de<br />

Thermal Fluids ACCESSORIES<br />

Operating range of thermal fluids<br />

P20.330.90: plus 20°C +330°C 90 mm²/s at 25°C<br />

M40.165.10: minus 40°C +165°C 10 mm²/s at 25°C<br />

-120 -100 -80 -60 -40 -20 0 +20 +40 +60 +80 +100 +200 +300<br />

M120.M08.02<br />

DW-Therm M90.200.02<br />

M90.055.03<br />

M80.055.03<br />

M60.115.05<br />

M40.165.10<br />

M20.235.20<br />

M10.155.08<br />

DW-Therm HT P20.330.90<br />

P20.190.40<br />

P20.275.50<br />

-120 -100 -80 -60 -40 -20 0 +20 +40 +60 +80 +100 +200 +300<br />

Thermal Fluid (G1) Litre Cat.No. Price<br />

DW-Therm* M90.200.02 10 6479<br />

DW-Therm HT* P20.330.90 5 6672<br />

10 6673<br />

MinOil P20.190.40 5 6155<br />

20 6156<br />

SynOil M10.155.08 5 6159<br />

10 6160<br />

SilOil P20.275.50 5 6157<br />

10 6158<br />

SilOil M20.235.20 5 6161<br />

10 6162<br />

SilOil M40.165.10 5 6163<br />

10 6164<br />

SilOil M60.115.05 5 6165<br />

10 6166<br />

SilOil M80.055.03 5 6167<br />

10 6168<br />

SilOil M80.100.03 5 6275<br />

10 6276<br />

SilOil M90.055.03 5 6258<br />

10 6259<br />

Kryothermal S M120.M08.02 5 6282<br />

Antifreeze (Ethylenglycol) 10 6170<br />

50 6171<br />

Algae Protection 0,1 6172<br />

* exclusive for Unistats<br />

www.huber-online.com · Tel. +49-781-96030<br />

45


ACCESSORIES General<br />

M16x1<br />

M24x1,5<br />

M30x1,5<br />

M38x1,5<br />

1/2“<br />

3/4“<br />

Accessories M16x1 (G1) Cat.No. Price<br />

Hose Connector NW 8 6086<br />

Hose Connector NW 12 6087<br />

Blank Plug 6088<br />

Nut 6089<br />

Micro Hose Connector NW 3,2 6090<br />

90° Adaptor 6195<br />

Ball Valve 6091<br />

2-way Header 6194<br />

3-way Header 6193<br />

4-way Header 6187<br />

5-way Header 6815<br />

2-way Valve System 6284<br />

3-way Valve System 6285<br />

4-way Valve System 6286<br />

5-way Valve System 6816<br />

Accessories M24x1,5 (G1) Cat.No. Price<br />

90° Adaptor 9256<br />

Ball Valve 9236<br />

2-way Header 9233<br />

3-way Header 9234<br />

4-way Header 9235<br />

2-way Valve System 9245<br />

3-way Valve System 9246<br />

4-way Valve System 9247<br />

Accessories M30x1,5 (G1) Cat.No. Price<br />

90° Adaptor 6461<br />

Ball Valve 6451<br />

2-way Header 6420<br />

3-way Header 6421<br />

4-way Header 6422<br />

2-way Header with Ball Valves 6423<br />

3-way Header with Ball Valves 6463<br />

4-way Header with Ball Valves 6464<br />

Accessories M38x1,5 (G1) Cat.No. Price<br />

90° Adaptor 6699<br />

Ball Valve 6700<br />

2-way Header 6706<br />

3-way Header 6707<br />

4-way Header 6708<br />

2-way Valve System 6709<br />

3-way Valve System 6710<br />

4-way Valve System 6711<br />

Accessories 1/2“ and 3/4“ (G1) Cat.No. Price<br />

Hose connections 1/2“ 2294<br />

for 3/8“ hose<br />

Hose connections 3/4“ 2295<br />

for 1/2“ hose<br />

46 www.huber-online.com · Tel. +49-781-96030<br />

Adaptors<br />

Adaptor (G1) Cat.No. Price<br />

M16x1 male to M16x1 male 6278<br />

M16x1 female to M16x1 female 6359<br />

M16x1 male to 1/2“ male 6299<br />

M16x1 male to 1/2“ female 6364<br />

M16x1 female to 1/2“ male 6360<br />

M16x1 female to 1/2“ female 6229<br />

M16x1 male to 3/4“ female 5443<br />

M16x1 female to 3/4“ female 6361<br />

M16x1 female to M30x1,5 male 6431<br />

M16x1 male to M30x1,5 male 6449<br />

M16x1 male to M30x1,5 female 6454<br />

M24x1,5 female to M30x 1,5 male 6723<br />

M24x1,5 female to M16x1 male 6724<br />

M24x1,5 female to 3/4“ NPT female 6874<br />

M24x1,5 male to M16x1 female 6945<br />

M30x1,5 male to M30x1,5 male 6448<br />

M30x1,5 female to 3/8“ male 6445<br />

M30x1,5 male to 1/2“ male 6393<br />

M30x1,5 male to 1/2“ female 6394<br />

M30x1,5 female to 1/2“ male 6391<br />

M30x1,5 female to 1/2“ female 6392<br />

M30x1,5 male to 3/4“ male 6447<br />

M30x1,5 male to 3/4“ female 6442<br />

M30x1,5 female to 3/4“ NPT male 6472<br />

M30x1,5 female to 3/4“ female 6452<br />

M30x1,5 male to 1“ male 6444<br />

M30x1,5 female to 1“ female 6453<br />

1/2“ female to 1/2“ female 6358<br />

1/2“ female to 3/4“ NPT female 6356<br />

M38x1,5 female to 1“ NPT male 6600<br />

M38x1,5 female to M30x1,5 male 6612<br />

M38x1,5 female to 3/4“ male 6665<br />

Other adaptors on request


Hoses<br />

Hose max. [°C] Length Cat.No. G Price<br />

NW 3,2 PVC 60 variable 6072 1<br />

NW 8 PVC 60 variable 6071 1<br />

NW 12 PVC 60 variable 6070 1<br />

NW 8 Perbunan 120 variable 6075 1<br />

NW 12 Perbunan 120 variable 6073 1<br />

NW 8 Silicon 180 variable 6077 1<br />

NW 12 Silicon 180 variable 6076 1<br />

NW 8 Viton 200 variable 6079 1<br />

NW 12 Viton 200 variable 6078 1<br />

NW 8 Teflon 200 variable 6350 1<br />

NW 12 Teflon 200 variable 6351 1<br />

Insulated hose Temperature Length Cat.No. G Price<br />

Range<br />

NW 10 M16x1 -100...350°C 100 cm 6084 1<br />

NW 10 M16x1 -100...350°C 150 cm 6085 1<br />

NW 10 M16x1 -100...350°C 200 cm 6136 1<br />

NW 10 M16x1 -100...350°C 300 cm 6255 1<br />

NW 12 M24x1,5 -120...400°C 100 cm 6784 1<br />

NW 12 M24x1,5 -120...400°C 150 cm 6785 1<br />

NW 12 M24x1,5 -120...400°C 200 cm 6786 1<br />

NW 12 M24x1,5 -120...400°C 300 cm 6787 1<br />

NW 20 M30x1,5 -100...350°C 100 cm 6426 1<br />

NW 20 M30x1,5 -100...350°C 150 cm 6386 1<br />

NW 20 M30x1,5 -100...350°C 200 cm 6427 1<br />

NW 20 M30x1,5 -100...350°C 300 cm 6428 1<br />

NW 25 M38x1,5 -100...350°C 100 cm 6655 1<br />

NW 25 M38x1,5 -100...350°C 150 cm 6656 1<br />

NW 25 M38x1,5 -100...350°C 200 cm 6657 1<br />

NW 25 M38x1,5 -100...350°C 300 cm 6658 1<br />

Cooling Water Hoses<br />

Cooling Water Hose Temperature Length Cat.No. G Price<br />

(Flexible braided hose) Range<br />

1/2“ -10...100°C 100 cm 16851 1<br />

1/2“ -10...100°C 150 cm 16852 1<br />

1/2“ -10...100°C 200 cm 16853 1<br />

3/4“ -10...100°C 100 cm 16854 1<br />

3/4“ -10...100°C 150 cm 16855 1<br />

3/4“ -10...100°C 200 cm 16856 1<br />

1“ -10...100°C 100 cm 16857 1<br />

1“ -10...100°C 150 cm 16858 1<br />

1“ -10...100°C 200 cm 16859 1<br />

General ACCESSORIES<br />

Hose insulation Digital thermometer<br />

Hose insulation Internal Ø Thickness Cat.No. G Price<br />

For hose:<br />

For metal hose:<br />

13 mm 7 mm NW 8 6083 1<br />

17 mm 7 mm NW 12 6082 1<br />

17 mm 12 mm NW 12 3968 1<br />

42 mm 22 mm M16x1 6375 1<br />

57 mm 23 mm M30x1,5 6377 1<br />

50 mm 22 mm 1/2“ 6376 1<br />

for precise temperature measurement<br />

from -60 to +400°C<br />

Digital thermometer D400 Cat.No. Price<br />

(G1)<br />

Digital thermometer D400 307.0001<br />

Handle D400 for dense masses 6116<br />

Imitation leather pocket for D400 6190<br />

Battery 9V IEC 6F22 (pack of 3) 6191<br />

Heat transfer paste 15 g 6122<br />

Heat transfer paste 50 g 6149<br />

www.huber-online.com · Tel. +49-781-96030<br />

47


QUICK FINDER<br />

Quick Finder Thermostats<br />

Low<br />

Demand<br />

„A“ Series<br />

„B“ Series<br />

VPC Range<br />

304B Series<br />

308B Series<br />

315B Series<br />

Above 30°C<br />

Heating<br />

High<br />

Demand<br />

Internal<br />

(e.g. Sample immersion,<br />

test tubes etc.)<br />

Below 30°C<br />

Heating + Cooling<br />

Low<br />

Demand<br />

„K“ Series<br />

„DC“ Series<br />

„TC“ Series<br />

VPC Range<br />

Variostat<br />

Ministat Series<br />

48 www.huber-online.com · Tel. +49-781-96030<br />

High<br />

Demand<br />

Thermal Control<br />

Required<br />

Open Bath Systems<br />

80°C…400°C<br />

Heating<br />

Unistat range<br />

CC400 Series<br />

CC401 Series<br />

Unistat range<br />

T326 Series<br />

T327 Series<br />

Unistat range<br />

Tango<br />

34x Series<br />

14x Series<br />

15x Series<br />

16x Series<br />

36x Series<br />

38x Series<br />

39x Series<br />

29x Series<br />

42x Series<br />

External<br />

(e. g. reactor,<br />

reaction block, rotary<br />

evap. etc.)<br />

100°C…300°C<br />

Heating<br />

Low Volume Sealed<br />

Systems<br />

-120°C…300°C<br />

Heating +<br />

Cooling


Quick Finder Chillers<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

QUICK FINDER<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

www.huber-online.com · Tel. +49-781-96030<br />

49


TECHNICAL DATA<br />

Model<br />

Catalogue Page<br />

COMPATIBLE CONTROL THERMOSTATS<br />

Temperature Range<br />

Tmin with cooling<br />

Tmin with water cooling<br />

Heating Power<br />

Bath Volume<br />

min. Filling Capacity<br />

Bath Volume with<br />

Displacement Insert<br />

Bath Opening WxDxH<br />

Resolution of Display<br />

CC1-E 7 25...200 -30 20 2 0.1 0.02<br />

CC1-300B2X vpc 7 28...300 -20 2 0.1 0.02<br />

CC1-300B4X vpc 7 28...300 -20 3.0 / 4.0 0.1 0.02<br />

CC1-105A 8 25...100 -30 20 2 5 5 120x110x150 0.1 0.02<br />

CC1-106A 8 25...100 -30 20 2 6 6 120x210x150 0.1 0.02<br />

CC1-107A 8 25...100 -30 20 2 7 7 120x310x150 0.1 0.02<br />

CC1-111A 8 25...100 -30 20 2 11 11 302x165x150 0.1 0.02<br />

CC1-118A 8 25...100 -30 20 2 18 18 302x325x150 0.1 0.02<br />

CC1-130A Visco 3 8 20...80 20 2 31 90x90x370 0,01 0,01<br />

CC1-130A Visco 5 8 20...80 20 2 31 Ø51x370 0,01 0,01<br />

CC1-208B 9 25...200 -30 20 2 8.5 8.5 235x165x150 0.1 0.02<br />

CC1-212B 9 25...200 -30 20 2 12 12 295x193x150 0.1 0.02<br />

CC1-215B 9 25...200 -30 20 2 15 15 295x193x200 0.1 0.02<br />

CC1-220B 9 25...200 -30 20 2 20 20 295x370x150 0.1 0.02<br />

CC1-225B 9 25...200 -30 20 2 25 25 295x370x200 0.1 0.02<br />

CC1-202C 10 45...200 -30 20 2 1.8 1.8 Ø25x150 0.1 0.05<br />

CC1-205B 10 45...200 -30 20 2 4.5 3.1 3.1 105x90x150 0.1 0.05<br />

CC1-304B vpc 10 28...300 -20 2 4 100x130x145 0.1 0.02<br />

CC1-308B vpc 10 28...300 -20 3 8.5 5.2 130x110x155 0.1 0.02<br />

CC1-315B vpc 10 28...300 -20 3.0 / 4.0 15 8.5 270x145x200 0.1 0.02<br />

CC1-K12 11 -20...200 2 12 8 295x193x150 0.1 0.02 0.18<br />

CC1-K15 11 -20...200 2 15 11 295x193x200 0.1 0.02 0.2<br />

Cooling Power at<br />

CC1-K20 11 -30...200 2 20 12 295x370x150 0.1 0.02 0.35 0.21<br />

CC1-K25 11 -30...200 2 25 17 295x370x200 0.1 0.02 0.35 0.21<br />

variostat cc-1 12 -30...150 1 0.1 0.02 0.3 0.3 0.2 0.12<br />

CC1-K6 13 -25...200 2 4.5 150x140x150 0.1 0.02 0.15 0.05<br />

ministat 125-1 14 -25...150 1 2.75 1.3 178x80x120 0.1 0.02 0.3 0.3 0.21 0.05<br />

ministat 125w-1 14 -25...150 1 2.75 1.3 178x80x120 0.1 0.02 0.3 0.3 0.2 0.1<br />

ministat 230-1 14 -33...200 2 3.2 1.7 170x83x135 0.1 0.02 0.4 0.4 0.35 0.25<br />

ministat 230w-1 14 -33...200 2 3.2 1.7 170x83x135 0.1 0.02 0.4 0.4 0.35 0.25<br />

ministat 240-1 14 -40...200 2 4.9 2.8 200x85x157 0.1 0.02 0.55 0.55 0.5 0.35 0.03<br />

ministat 240w-1 14 -40...200 2 4.9 2.8 200x85x157 0.1 0.02 0.55 0.55 0.5 0.35 0.03<br />

CC1-305 vpc 16 -30...150 1.5 20 300x330x150 0.1 0.02 0.35 0.35 0.35 0.23<br />

CC1-405 vpc 16 -40...200 1.5 5 120x110x150 0.1 0.02 0.7 0.7 0.7 0.45 0.03<br />

CC1-405w vpc 16 -40...200 1.5 5 120x110x150 0.1 0.02 0.7 0.7 0.7 0.45 0.03<br />

CC1-415 vpc 16 -40...200 1.5 5 120x110x150 0.1 0.02 1.2 1.2 1 0.6 0.05<br />

CC1-415wl vpc 16 -40...200 1.5 5 120x110x150 0.1 0.02 1.2 1.2 1 0.6 0.05<br />

CC1-410wl vpc 16 -45...200 1.5 / 4.5 22 8.5 280x280x200 0.1 0.02 0.8 0.8 0.8 0.5 0.1<br />

CC1-505 vpc 17 -50...200 1.5 5 120x110x150 0.1 0.02 1.2 1.2 1 0.6 0.15<br />

CC1-505wl vpc 17 -50...200 1.5 5 120x110x150 0.1 0.02 1.2 1.2 1 0.6 0.15<br />

CC1-510 vpc 17 -50...100 3 18 11 270x150x200 0.1 0.02 2.1 2.1 2.1 1 0.4<br />

CC1-510w vpc 17 -50...100 3 18 11 270x150x200 0.1 0.02 2.4 2.4 2.4 1 0.4<br />

CC1-515 vpc 17 -55...100 3 26 15 260x260x200 0.1 0.02 3.3 3.3 3.3 1.6 0.6<br />

CC1-515w vpc 17 -55...100 3 18 11 270x150x200 0.1 0.02 3.3 3.3 3.3 1.6 0.6<br />

CC1-520w vpc 17 -55...100 3 17 10 270x150x200 0.1 0.02 5 5 5 3 1.5<br />

CC1-525w vpc 17 -55...100 3 17 10 270x150x200 0.1 0.02 7 7 5 3 1.5<br />

Temperature Stability<br />

300°C<br />

200°C<br />

100°C<br />

20°C<br />

0°C<br />

-20°C<br />

-40°C<br />

-60°C<br />

-80°C<br />

-100°C<br />

°C °C °C kW l l l mm K K kW kW kW kW kW kW kW kW kW kW<br />

CC1-705 vpc 18 -75...100 1.5 5 120x110x150 0.1 0.02 0.25 0.25 0.25 0.2 0.15 0.1<br />

CC1-805 vpc 18 -80...100 1.5 5 120x110x150 0.1 0.02 0.5 0.5 0.5 0.4 0.3 0.3<br />

CC1-820 vpc 18 -80...100 3 17 10 270x150x200 0.1 0.02 1.2 1.2 1.2 1.1 0.9 0.5 0.14<br />

CC1-820w vpc 18 -80...100 3 17 10 270x150x200 0.1 0.02 1.2 1.2 1.2 1.1 0.9 0.5 0.14<br />

Models with CC1 controller: Technical Data remains identical with controller change (CC2, CC3) FL = Suitable for inflammable and non-inflammable fluids<br />

50 www.huber-online.com · Tel. +49-781-96030


max. Flow Rate - Pressure Pump<br />

max. Press - Pressure Pump<br />

max. Flow Rate - Suction Pump<br />

max. Press - Suction Pump<br />

Pump Connection<br />

Circulation Pump<br />

Safety Standard<br />

Low Level Protection<br />

Overtemperature Protection<br />

Dimensions WxDxH<br />

TECHNICAL DATA<br />

Power supply<br />

Cooling of refrigeration machine<br />

l/min bar l/min bar mm kg V; Hz °C °C<br />

10 0.2 FL Yes Yes 120x135x300 4 230;50/60 5 32 688.0051 CC1-E<br />

Weight<br />

min. Ambient Temperature<br />

max. Ambient Temperature<br />

Natural Refrigerant**<br />

Cat.No.<br />

Cooling Water Connection<br />

33 0.7 22 0.4 M16x1 FL Yes Yes 345x190x380 11 230;50/60 5 32 683.0011BX CC1-300B2X vpc<br />

34 0.7 22 0.4 M16x1 FL Yes Yes 345x190x395 13 230;50/60 / 400;3~N;50* 5 32 684.0011BX CC1-300B4X vpc<br />

10 0.2 M16x1 FL Yes Yes 132x280x320 4.5 230;50/60 5 32 405.0001 CC1-105A<br />

10 0.2 M16x1 FL Yes Yes 132x380x320 5 230;50/60 5 32 405.0011 CC1-106A<br />

10 0.2 M16x1 FL Yes Yes 132x480x320 5 230;50/60 5 32 405.0021 CC1-107A<br />

10 0.2 M16x1 FL Yes Yes 333x313x325 6.5 230;50/60 5 32 405.0031 CC1-111A<br />

10 0.2 M16x1 FL Yes Yes 333x473x325 8 230;50/60 5 32 405.0041 CC1-118A<br />

10 0.2 FL Ja Ja 500x200x560 11 230;50/60 5 32 405.0051 CC1-130A Visco 3<br />

10 0,2 FL Ja Ja 500x200x560 11 230;50/60 5 32 405.0061 CC1-130A Visco 5<br />

10 0.2 M16x1 FL Yes Yes 290x350x375 10 230;50/60 5 32 407.0001 CC1-208B<br />

10 0.2 M16x1 FL Yes Yes 350x375x375 11 230;50/60 5 32 407.0011 CC1-212B<br />

10 0.2 M16x1 FL Yes Yes 350x375x420 12 230;50/60 5 32 407.0021 CC1-215B<br />

10 0.2 M16x1 FL Yes Yes 350x555x375 14 230;50/60 5 32 407.0031 CC1-220B<br />

10 0.2 M16x1 FL Yes Yes 350x555x420 16 230;50/60 5 32 407.0041 CC1-225B<br />

10 0.2 M16x1 FL Yes Yes 150x215x350 7.5 230;50/60 5 32 685.0011 CC1-202C<br />

10 0.2 M16x1 FL Yes Yes 150x285x350 8.5 230;50/60 5 32 686.0011 CC1-205B<br />

34 0.7 22 0.4 M16x1 FL Yes Yes 210x310x390 13 230;50/60 5 32 679.0001 CC1-304B vpc<br />

33 0.7 22 0.4 M16x1 FL Yes Yes 240x405x390 18 230;50/60 5 32 683.0021 CC1-308B vpc<br />

34 0.7 22 0.4 M16x1 FL Yes Yes 335x385x430 22 230; 50/60 / 400;3~N;50* 5 32 684.0011 CC1-315B vpc<br />

10 0.2 M16x1 FL Yes Yes 350x558x375 24 230;50 AIR 5 32 S 653.0021 CC1-K12<br />

10 0.2 M16x1 FL Yes Yes 350x558x420 28 230;50 AIR 5 32 S 645.0031 CC1-K15<br />

10 0.2 M16x1 FL Yes Yes 350x558x550 34 230;50/60 AIR 5 32 S 646.0031 CC1-K20<br />

10 0.2 M16x1 FL Yes Yes 350x558x600 36 230;50/60 AIR 5 32 S 647.0031 CC1-K25<br />

18 0.6 12 0.3 M16x1 FL Yes Yes 183x455x395 24 230;50/60 AIR 5 32 O 654.0011 variostat cc-1<br />

10 0.2 M16x1 FL Yes Yes 210x370x535 20 230;50 AIR 5 32 O 666.0021 CC1-K6<br />

27 0.7 20 0.4 M16x1 FL Yes Yes 225x370x360 25 230;50 AIR 5 32 O 740.0001 ministat 125-1<br />

27 0.7 20 0.4 M16x1 FL Yes Yes 225x370x360 25 230;50 WATER 5 32 1/2“ O 740.0011 ministat 125w-1<br />

27 0.7 20 0.4 M16x1 FL Yes Yes 255x450x400 35 230;50 AIR 5 32 O 741.0001 ministat 230-1<br />

27 0.7 20 0.4 M16x1 FL Yes Yes 255x450x400 35 230;50 WATER 5 32 1/2“ O 741.0011 ministat 230w-1<br />

27 0.7 20 0.4 M16x1 FL Yes Yes 300x465x455 41 230;50 AIR 5 32 O 742.0001 ministat 240-1<br />

27 0.7 20 0.4 M16x1 FL Yes Yes 300x465x455 41 230;50 WATER 5 32 1/2“ O 742.0011 ministat 240w-1<br />

33 0.7 22 0.4 M16x1 FL Yes Yes 350x575x600 43 230;50 AIR 5 32 O 690.0011 CC1-305 vpc<br />

33 0.7 22 0.4 M16x1 FL Yes Yes 370x480x660 55 230;50/60 AIR 5 32 O 697.0011 CC1-405 vpc<br />

33 0.7 22 0.4 M16x1 FL Yes Yes 370x480x660 55 230;50/60 WATER 5 32 1/2“ O 697.0021 CC1-405w vpc<br />

33 0.7 22 0.4 M16x1 FL Yes Yes 410x480x720 60 230;50/60 / 400;3~N;50* AIR 5 32 O 694.0011 CC1-415 vpc<br />

33 0.7 22 0.4 M16x1 FL Yes Yes 410x480x720 62 230;50/60 / 400;3~N;50* AIR+WATER 5 32 1/2“ O 694.0021 CC1-415wl vpc<br />

33 0.7 22 0.4 M16x1 FL Yes Yes 420x590x700 72 230;50 / 400;3~N;50* AIR+WATER 5 32 1/2“ O 695.0011 CC1-410wl vpc<br />

33 0.7 22 0.4 M16x1 FL Yes Yes 410x480x720 60 230;50/60 / 400;3~N;50* AIR 5 32 O 696.0011 CC1-505 vpc<br />

33 0.7 22 0.4 M16x1 FL Yes Yes 410x480x720 62 230;50/60 / 400;3~N;50* AIR+WATER 5 32 1/2“ O 696.0021 CC1-505wl vpc<br />

31 0.6 24 0.35 M16x1 FL Yes Yes 455x515x995 99 400;3~N;50 AIR 5 32 O 564.0021 CC1-510 vpc<br />

31 0.6 24 0.35 M16x1 FL Yes Yes 455x515x995 96 400;3~N;50 WATER 5 32 1/2“ O 564.0031 CC1-510w vpc<br />

31 0.6 24 0.35 M16x1 FL Yes Yes 600x700x1130 98 400;3~N;50 AIR 5 32 O 651.0011 CC1-515 vpc<br />

31 0.6 24 0.35 M16x1 FL Yes Yes 455x515x995 98 400;3~N;50 WATER 5 32 1/2“ O 651.0021 CC1-515w vpc<br />

31 0.6 24 0.35 M16x1 FL Yes Yes 540x630x1085 142 400;3~N;50 WATER 5 32 1/2“ O 698.0011 CC1-520w vpc<br />

31 0.6 24 0.35 M16x1 FL Yes Yes 540x630x1085 142 400;3~N;50 WATER 5 32 1/2“ O 700.0001 CC1-525w vpc<br />

33 0.7 22 0.4 M16x1 FL Yes Yes 410x480x720 78 230;50 / 400;3~N;50* AIR 5 32 O 692.0011 CC1-705 vpc<br />

33 0.7 22 0.4 M16x1 FL Yes Yes 410x480x720 81 230;50 / 400;3~N;50* AIR 5 32 O 693.0011 CC1-805 vpc<br />

31 0.6 24 0.35 M16x1 FL Yes Yes 540x630x1085 150 400;3~N;50 AIR 5 32 O 567.0021 CC1-820 vpc<br />

31 0.6 24 0.35 M16x1 FL Yes Yes 540x630x1085 150 400;3~N;50 WATER 5 32 1/2“ O 567.0031 CC1-820w vpc<br />

* Voltage can be changed, must be specified with order ** S = Standard, O = Option, R = on Request<br />

www.huber-online.com · Tel. +49-781-96030<br />

Model<br />

51


TECHNICAL DATA<br />

Model<br />

CC1-815 vpc 18 -85...100 1.5 5 120x110x150 0.1 0.02 1 1 1 0.8 0.75 0.6<br />

CC1-905 vpc 18 -90...100 3 26 15 260x260x200 0.1 0.02 2 2 2 1.9 1.7 0.5 0.34<br />

CC1-905w vpc 18 -90...100 3 26 15 260x260x200 0.1 0.02 2 2 2 1.9 1.7 0.5 0.34<br />

DC30 19 -30...50 0.15 0.07<br />

DC31 19 -30...50 0.35 0.1<br />

DC32 19 -30...50 0.47 0.12<br />

TC45 19 45...100 0.24 0.18 0.05<br />

TC45E 19 -45...100 0.1 0.5 0.24 0.18 0.05<br />

TC50 19 -50...50 0.3 0.26<br />

TC50E 19 -50...50 0.1 0.5 0.3 0.26<br />

TC100 19 -100...40 0.15 0.14<br />

TC100E 19 -100...40 0.1 0.5 0.15 0.14<br />

K12 20 -20...200 12 295x320x150 0.18<br />

K15 20 -20...200 15 295x320x200 0.2<br />

K20 20 -30...200 20 295x500x150 0.35 0.21<br />

K25 20 -30...200 25 295x500x200 0.35 0.21<br />

UNISTATS<br />

Catalogue Page<br />

Temperature Range<br />

Tmin with cooling<br />

Heating Power<br />

Tmin with water cooling<br />

Bath Volume<br />

min. Filling Capacity<br />

Bath Volume with<br />

Displacement Insert<br />

Bath Opening WxDxH<br />

Resolution of Display<br />

unistat T326 29 65...300 15 3.0 / 6.0 1.45 0.1 0.02<br />

unistat T326 HT 29 65...300 3.0 / 6.0 1.9 0.1 0.02 3.2 2.3 0.6<br />

unistat T326w HT 29 65...300 15 3.0 / 6.0 1.9 0.1 0.02 10 10 10<br />

unistat T327 29 65...300 15 12 3.5 0.1 0.02<br />

unistat T327w HT 29 65...300 15 12 3.5 0.1 0.02 10 10 6<br />

unistat cc 400-3 29 75...400 3 0.8 0.1 0.05<br />

unistat cc 401-3 29 50...400 3.0 / 9.0 3 0.1 0.05<br />

unistat cc 401w HT-3 29 50...400 3.0 / 9.0 2.3 0.1 0.05 10 10 10<br />

Cooling Power at<br />

unistat tango 31 -40...200 1.5 / 3.0 1.45 0.1 0.02 0.7 0.7 0.7 0.7 0.4 0.05<br />

unistat tango HT 31 -40...300 1.5 / 3.0 1.9 0.1 0.02 3.2 2.3 1.3 0.7 0.7 0.4 0.05<br />

unistat 340 31 -40...200 1.5 / 3.0 1.45 0.1 0.02 1 1 1 1 0.6 0.1<br />

unistat 340w 31 -40...200 1.5 / 3.0 1.45 0.1 0.02 1 1 1 1 0.6 0.1<br />

unistat 340 HT 31 -40...300 1.5 / 3.0 1.9 0.1 0.02 3.2 2.3 1.8 1 1 0.6 0.1<br />

unistat 340w HT 31 -40...300 1.5 / 3.0 1.9 0.1 0.02 3.5 2.3 1.8 1 1 0.6 0.1<br />

unistat 140 31 -40...200 2 3.6 0.1 0.02 2 2 2 2.5 1.8 0.2<br />

unistat 140w 31 -40...200 2 3.6 0.1 0.02 2 2 2 2.5 1.8 0.2<br />

unistat 140w-FB 31 -40...200 2 4.7 0.1 0.02 2 2 2 2.5 1.8 0.2<br />

unistat 140 HT 31 -40...300 2 5 0.1 0.02 3.2 2.3 2.7 2 2.5 1.8 0.2<br />

unistat 140w HT 31 -40...300 2 5 0.1 0.02 3.5 3 2.7 2 2.5 1.8 0.2<br />

unistat 141 31 -40...200 4 3.9 0.1 0.02 3.5 3.5 3.5 3.5 2.2 0.3<br />

unistat 141w 31 -40...200 4 3.9 0.1 0.02 3.5 3.5 3.5 3.5 2.2 0.2<br />

unistat 141w-FB 31 -40...200 4 4.1 0.1 0.02 3.5 3.5 3.5 3.5 2.2 0.2<br />

unistat 141 HT 31 -40...300 4 5 0.1 0.02 3.2 4 3.5 3.5 3.5 2.2 0.3<br />

unistat 141w HT 31 -40...300 4 5 0.1 0.02 3.5 4 3.5 3.5 3.5 2.2 0.2<br />

unistat 150w 31 -50...200 6 4.3 0.1 0.02 5 5 5 2.8 0.9<br />

unistat 150w HT 31 -50...300 6 6.4 0.1 0.02 3.5 6 5.5 5 2.8 0.9<br />

unistat 151w 31 -55...200 6 5.1 0.1 0.02 6 6 6 4.2 1.5<br />

unistat 151w-FB 31 -55...200 6 8.6 0.1 0.02 5 5 6 4.2 1.5<br />

Temperature Stability<br />

300°C<br />

200°C<br />

100°C<br />

20°C<br />

0°C<br />

-20°C<br />

-40°C<br />

-60°C<br />

-80°C<br />

-100°C<br />

°C °C °C kW l l l mm K K kW kW kW kW kW kW kW kW kW kW<br />

unistat 160w 31 -60...200 6 5.65 0.1 0.02 7 7 7 6 3.3 0.8<br />

unistat 161w 31 -60...200 12 5.65 0.1 0.02 9 9 9 7 5 1<br />

unistat 162w 31 -60...200 12 5.2 0.1 0.02 12 12 12 12 7 2<br />

unistat 163w 31 -60...200 12 3.4 0.1 0.02 16 16 16 16 13.5 8.4 2.2<br />

unistat 164w 31 -60...200 24 20 0.1 0.02 22 22 20 18 15 5<br />

unistat 165w 31 -60...200 24 21 0.1 0.02 26 26 25 24 18 6<br />

Models with CC1 controller: Technical Data remains identical with controller change (CC2, CC3) FL = Suitable for inflammable and non-inflammable fluids<br />

52 www.huber-online.com · Tel. +49-781-96030


max. Flow Rate - Pressure Pump<br />

max. Press - Pressure Pump<br />

max. Flow Rate - Suction Pump<br />

max. Press - Suction Pump<br />

Pump Connection<br />

Circulation Pump<br />

Safety Standard<br />

Low Level Protection<br />

Overtemperature Protection<br />

Dimensions WxDxH<br />

TECHNICAL DATA<br />

Power supply<br />

Cooling of refrigeration machine<br />

l/min bar l/min bar mm kg V; Hz °C °C<br />

Weight<br />

min. Ambient Temperature<br />

max. Ambient Temperature<br />

Natural Refrigerant**<br />

Cat.No.<br />

Cooling Water Connection<br />

33 0.7 22 0.4 M16x1 FL Yes Yes 550x600x890 139 230;50 AIR 5 32 O 699.0001 CC1-815 vpc<br />

31 0.6 24 0.35 M16x1 FL Yes Yes 600x700x1130 162 400;3~N;50 AIR 5 32 O 568.0011 CC1-905 vpc<br />

31 0.6 24 0.35 M16x1 FL Yes Yes 600x700x1130 170 400;3~N;50 WATER 5 32 1/2“ O 568.0021 CC1-905w vpc<br />

M16x1 No No 190x250x360 16 230;50 AIR 5 32 O 574.0002 DC30<br />

M16x1 No No 250x310x400 25 230;50/60 AIR 5 32 S 575.0002 DC31<br />

M16x1 No No 280x340x460 30 230;50 AIR 5 32 O 652.0002 DC32<br />

No No 190x250x360 16 230;50 AIR S 570.0008 TC45<br />

No No 190x250x360 16 230;50 AIR S 570.0009 TC45E<br />

No No 250x310x400 25 230;50/60 AIR S 572.0006 TC50<br />

No No 250x310x400 25 230;50/60 AIR S 572.0007 TC50E<br />

No No 280x440x525 55 230;50 AIR O 573.0007 TC100<br />

No No 280x440x525 55 230;50 AIR O 573.0008 TC100E<br />

No No 350x558x215 20 230;50 AIR S 653.0020 K12<br />

No No 350x558x240 19 230;50 AIR S 645.0021 K15<br />

No No 350x558x370 30 230;50/60 AIR S 646.0021 K20<br />

No No 350x558x420 35 230;50/60 AIR S 647.0021 K25<br />

15 0.5 M16x1 FL Yes Yes 425x220x635 35 230;50/60 / 400;3~N;50* 5 32 1/2“ 532.0002 unistat T326<br />

15 0.5 M16x1 FL Yes Yes 425x220x635 36 230;50/60 / 400;3~N;50* 5 32 531.0002 unistat T326 HT<br />

15 0.5 M16x1 FL Yes Yes 425x220x635 42 230;50/60 / 400;3~N;50* 5 32 1/2“ 530.0002 unistat T326w HT<br />

70 1.6 M30x1,5 FL Yes Yes 460x550x1336 90 400;3~N;50 5 32 1/2“ 525.0002 unistat T327<br />

60 1.6 M30x1,5 FL Yes Yes 460x550x1336 124 400;3~N;50 5 32 1/2“ 526.0002 unistat T327w HT<br />

27 0.75 FL Yes Yes 190x240x635 21 230;50/60 5 32 1/2“ 400.0003 unistat cc 400-3<br />

31 1 FL Yes Yes 285x330x735 37 230;50 / 400;3~N;50* 5 40 1/2“ 400.0023 unistat cc 401-3<br />

31 1.0 FL Yes Yes 285x330x735 45 230;50 / 400;3~N;50* 5 40 1/2“ 400.0033 unistat cc 401w HT-3<br />

15 0.5 M16x1 FL Yes Yes 425x270x636 58 230;50/60 / 400;3~N;50* AIR 5 32 O 534.0003 unistat tango<br />

15 0.5 M16x1 FL Yes Yes 425x270x636 59 230;50/60 / 400;3~N;50* AIR 5 32 O 533.0003 unistat tango HT<br />

20 0.7 M16x1 FL Yes Yes 425x300x636 62 230;50/60 / 400;3~N;50* AIR 5 32 O 710.0004 unistat 340<br />

20 0.7 M16x1 FL Yes Yes 425x270x636 55 230;50/60 / 400;3~N;50* WATER 5 32 1/2“ O 710.0003 unistat 340w<br />

15 0.5 M16x1 FL Yes Yes 425x300x636 65 230;50/60 / 400;3~N;50* AIR 5 32 O 711.0003 unistat 340 HT<br />

15 0.5 M16x1 FL Yes Yes 425x300x636 62 230;50/60 / 400;3~N;50* WATER 5 32 1/2“ O 711.0004 unistat 340w HT<br />

100 1.5 M30x1,5 FL Yes Yes 460x550x1336 155 400;3~N;50 AIR 5 32 R 544.0004 unistat 140<br />

100 1.5 M30x1,5 FL Yes Yes 460x550x1336 159 400;3~N;50 WATER 5 32 1/2“ R 545.0004 unistat 140w<br />

100 1.5 M30x1,5 FL Yes Yes 920x635x740 153 400;3~N;50 WATER 5 32 1/2“ R 545.0004FB unistat 140w-FB<br />

60 1.6 M30x1,5 FL Yes Yes 460x550x1336 190 400;3~N;50 AIR 5 32 R 712.0001 unistat 140 HT<br />

60 1.6 M30x1,5 FL Yes Yes 460x550x1336 178 400;3~N;50 WATER 5 32 1/2“ R 712.0002 unistat 140w HT<br />

90 1.5 M30x1,5 FL Yes Yes 460x550x1336 161 400;3~N;50 AIR 5 32 R 550.0005 unistat 141<br />

90 1.5 M30x1,5 FL Yes Yes 460x550x1336 159 400;3~N;50 WATER 5 32 1/2“ R 551.0005 unistat 141w<br />

70 1.6 M30x1,5 FL Yes Yes 920x635x740 153 400;3~N;50 WATER 5 32 1/2“ R 551.0005FB unistat 141w-FB<br />

60 1.6 M30x1,5 FL Yes Yes 460x550x1336 159 400;3~N;50 AIR 5 32 R 713.0003 unistat 141 HT<br />

60 1.6 M30x1,5 FL Yes Yes 460x550x1336 159 400;3~N;50 WATER 5 32 1/2“ R 713.0004 unistat 141w HT<br />

100 1.5 M30x1,5 FL Yes Yes 460x550x1336 163 400;3~N;50 WATER 5 32 1/2“ R 715.0001 unistat 150w<br />

80 1.5 M30x1,5 FL Yes Yes 460x550x1336 180 400;3~N;50 WATER 5 32 1/2“ R 716.0001 unistat 150w HT<br />

60 1.5 M30x1,5 FL Yes Yes 540x600x1336 203 400;3~N;50 WATER 5 32 1/2“ R 717.0001 unistat 151w<br />

60 1.5 M30x1,5 FL Yes Yes 920x635x740 202 400;3~N;50 WATER 5 32 1/2“ R 717.0001FB unistat 151w-FB<br />

50 1.5 M30x1,5 FL Yes Yes 600x700x1515 348 400;3~N;50 WATER 5 32 1/2“ R 552.0005 unistat 160w<br />

50 1.5 M30x1,5 FL Yes Yes 600x700x1515 358 400;3~N;50 WATER 5 32 1/2“ R 556.0005 unistat 161w<br />

90 2.5 M30x1,5 FL Yes Yes 700x800x1515 440 400;3~N;50 WATER 5 32 3/4“ R 557.0005 unistat 162w<br />

90 2.5 M30x1,5 FL Yes Yes 700x800x1515 448 400;3~N;50 WATER 5 32 3/4“ R 559.0004 unistat 163w<br />

110 2.5 M38x1,5 FL Yes Yes 920x1000x1655 740 400;3~N;50 WATER 5 32 3/4“ R 719.0001 unistat 164w<br />

110 2.5 M38x1,5 FL Yes Yes 920x1000x1655 734 400;3~;50 WATER 5 32 3/4“ R 720.0001 unistat 165w<br />

* Voltage can be changed, must be specified with order ** S = Standard, O = Option, R = on Request<br />

www.huber-online.com · Tel. +49-781-96030<br />

Model<br />

53


TECHNICAL DATA<br />

Model<br />

unistat 166w 31 -60...200 30 27.5 0.1 0.02 30 30 30 27 20 6<br />

unistat 167w 31 -60...200 36 30 0.1 0.02 40 40 40 40 22 7<br />

unistat 169w 31 -60...200 48 28 0.1 0.02 65 65 65 65 38 11<br />

unistat 1060w 31 -60...200 96 40 0.1 0.02 130 130 80 60 20<br />

unistat minus 55w-FB-3 31 -55...50 2 16.7 0.1 1 6 6 4.2 1.5<br />

unistat minus 85w-3-FB 31 -85...50 2 3 0.1 1.5 2.3 2.3 2.3 2 1.2 0.2<br />

unistat minus 90w-3 31 -90...50 4 3.8 0.1 1.5 5.2 5.2 5 4.2 2.9 0.75<br />

unistat minus 90w-FB-3 31 -90...50 4 3.8 0.1 1.5 5.2 5.2 5 4.2 2.9 0.75<br />

unistat 360 32 -75...200 1.5 / 3.0 1.45 0.1 0.02 0.6 0.6 0.6 0.6 0.6 0.6 0.3<br />

unistat 360w 32 -75...200 1.5 / 3.0 1.45 0.1 0.02 0.6 0.6 0.6 0.6 0.6 0.6 0.3<br />

unistat 360 HT 32 -75...300 1.5 / 3.0 1.9 0.1 0.02 3.2 2.3 1.4 0.6 0.6 0.6 0.6 0.3<br />

unistat 360w HT 32 -75...300 1.5 / 3.0 1.9 0.1 0.02 3.5 2.3 1.4 0.6 0.6 0.6 0.6 0.3<br />

unistat 380 32 -80...200 2 3.8 0.1 0.02 1.3 1.3 1.3 1.3 1.3 1.3 0.9 0.2<br />

unistat 380w 32 -80...200 2 3.2 0.1 0.02 1.5 1.5 1.5 1.5 1.5 1.5 0.9 0.2<br />

unistat 380 HT 32 -80...300 2 3.8 0.1 0.02 3.2 2.3 1.8 1.3 1.3 1.3 1.3 0.9 0.2<br />

unistat 380w HT 32 -80...300 2 3.8 0.1 0.02 3.5 2.3 1.8 1.5 1.5 1.5 1.5 0.9 0.2<br />

unistat 380w HT-FB 32 -80...300 2 3.8 0.1 0.02 3.5 2.3 1.8 1.5 1.5 1.5 1.5 0.9 0.2<br />

unistat 385 32 -85...200 3 2.9 0.1 0.02 2.3 2.3 2.3 2.3 2.3 2 1.2 0.3<br />

unistat 385w 32 -85...200 3 3 0.1 0.02 2.3 0 2.3 2.3 2.3 2 1.2 0.3<br />

unistat 385w-FB 32 -85...200 3 0.1 0.02 2.3 2.3 2.3 2.3 2.3 2 1.2 0.3<br />

unistat 385 HT 32 -85...300 3 3.8 0.1 0.02 3.2 2.3 2.7 2.3 2.3 2.3 2 1.2 0.3<br />

unistat 385w HT 32 -85...300 3 4.6 0.1 0.02 3.5 2.3 2.7 2.3 2.3 2.3 2 1.2 0.3<br />

unistat 386 32 -85...200 3 3 0.1 0.02 4.0 3.8 3.6 3.5 3.5 3 2 0.6<br />

unistat 386w 32 -85...200 3 3 0.1 0.02 4.0 3.8 3.6 3.5 3.5 3 2 0.6<br />

unistat 390w 32 -90...200 6 4.3 0.1 0.02 5.2 5.2 5.2 5 4.2 3.1 0.9<br />

unistat 390w HT 32 -90...300 6 6.4 0.1 0.02 4.5 2.6 7 5.2 5.2 5 4.2 3.1 0.9<br />

unistat 290w 32 -90...200 12 5.5 0.1 0.02 16 16 16 16 16 15 13.5 3.5<br />

unistat 291w 32 -90...200 24 5.5 0.1 0.02 19 19 19 19 19 17 15 6<br />

unistat 292 32 -90...200 36 11 0.1 0.02 30 30 30 30 30 28 24 10<br />

unistat 292w 32 -90...200 36 11 0.1 0.02 30 30 30 30 30 28 24 10<br />

unistat 420w 33 -120...100 2 3.6 0.1 0.02 1.5 1.5 1.5 1.5 1.5 1.4 1.3 1<br />

unistat 420w HT 33 -120...300 2 5 0.1 0.02 3.5 3.2 3 1.5 1.5 1.5 1.5 1.4 1.3 1<br />

unistat 421w 33 -120...100 4 7 0.1 0.02 2.5 2.5 2.5 2.5 2.5 2.5 2 2<br />

CAL 1 33 -20...150 1 7 0 Ø120 x 400 0.1 0.01 0.3<br />

CAL 2 33 -40...200 1.5 7 7 Ø120 x 400 0.1 0.01 0.5<br />

CAL 3 33 -80...150 1.5 7 7 Ø120 x 400 0.1 0.01 0.3<br />

CAL 4 33 25...250 1.5 7 7 Ø120 x 400 0.1 0.01<br />

UNICHILLERS<br />

Catalogue Page<br />

Temperature Range<br />

Tmin with cooling<br />

Heating Power<br />

Tmin with water cooling<br />

Bath Volume<br />

min. Filling Capacity<br />

Bath Volume with<br />

Displacement Insert<br />

Bath Opening WxDxH<br />

Resolution of Display<br />

minichiller 38 -20...40 1.4 0.1 1 0.2 0.07<br />

minichiller w 38 -20...40 1.4 0.1 1 0.2 0.07<br />

minichiller-1 38 -20...40 1.4 0.1 1 0.2 0.07<br />

minichiller w-1 38 -20...40 2.6 0.1 1 0.2 0.07<br />

UC006A-1 38 -20...40 1.25 0.1 0.5 0.5<br />

UC007 38 -20...40 4.4 0.1 1 0.55 0.16<br />

UC007-1 38 -20...40 4.4 0.1 1 0.55 0.16<br />

UC015-1 38 -10...40 0.9 0.1 0.5 1<br />

UC015w-1 38 -10...40 0.9 0.1 0.5 1<br />

UC022-1 38 -10...40 3.5 0.1 0.5 1.6<br />

UC022w-1 38 -10...40 0.8 0.1 0.5 1.6<br />

UC020-1 38 -10...40 0.8 0.1 0.5 2<br />

UC020w-1 38 -10...40 0.8 0.1 0.5 2<br />

Cooling Power at<br />

Temperature Stability<br />

300°C<br />

200°C<br />

100°C<br />

20°C<br />

0°C<br />

-20°C<br />

-40°C<br />

-60°C<br />

-80°C<br />

-100°C<br />

°C °C °C kW l l l mm K K kW kW kW kW kW kW kW kW kW kW<br />

Models with CC1 controller: Technical Data remains identical with controller change (CC2, CC3) FL = Suitable for inflammable and non-inflammable fluids<br />

54 www.huber-online.com · Tel. +49-781-96030


max. Flow Rate - Pressure Pump<br />

max. Press - Pressure Pump<br />

max. Flow Rate - Suction Pump<br />

max. Press - Suction Pump<br />

Pump Connection<br />

Circulation Pump<br />

Safety Standard<br />

Overtemperature Protection<br />

Low Level Protection<br />

Dimensions WxDxH<br />

TECHNICAL DATA<br />

Power supply<br />

Cooling of refrigeration machine<br />

l/min bar l/min bar mm kg V; Hz °C °C<br />

100 2.5 M38x1,5 FL Yes Yes 920x1200x1655 825 400;3~;50 WATER 5 32 3/4“ R 723.0001 unistat 166w<br />

100 2.5 M38x1,5 FL Yes Yes 1800x1200x1830 1400 400;3~;50 WATER 5 32 1 1/2“ R 724.0001 unistat 167w<br />

100 2.5 M38x1,5 FL Yes Yes 1800x1200x1830 1400 400;3~;50 WATER 5 32 1 1/2“ R 726.0001 unistat 169w<br />

100 2.5 M38x1,5 FL Yes Yes 4500x2000x2000 3500 400;3~N;50 WATER 5 32 2“ R 733.0001 unistat 1060w<br />

55 1.6 M30x1,5 FL Yes Yes 920x635x740 206 400;3~N;50 WATER 5 32 1/2“ R 717.0106 unistat minus 55w FB-3<br />

18 0.7 M30x1,5 FL Yes Yes 1200x650x745 277 400;3~N;50 WATER 5 32 1/2“ R 549.0105 unistat minus 85w-3-FB<br />

40 1.5 M30x1,5 FL Yes Yes 600x700x1550 392 400;3~N;50 WATER 5 32 1/2“ R 554.0112 unistat minus 90w-3<br />

40 1.5 M30x1,5 FL Yes Yes 1500x700x900 399 400;3~N;50 WATER 5 30 1/2“ R 554.0109 unistat minus 90w-FB-3<br />

25 0.8 M16x1 FL Yes Yes 425x400x720 88 230;50 / 400;3~N;50* AIR 5 32 O 536.0006 unistat 360<br />

25 0.8 M16x1 FL Yes Yes 425x400x720 87 230;50 / 400;3~N;50* WATER 5 32 1/2“ O 536.0005 unistat 360w<br />

16 0.8 M16x1 FL Yes Yes 425x400x720 91 230;50 / 400;3~N;50* AIR 5 32 O 535.0006 unistat 360 HT<br />

16 0.8 M16x1 FL Yes Yes 425x400x720 91 230;50 / 400;3~N;50* WATER 5 32 1/2“ O 535.0005 unistat 360w HT<br />

35 0.8 M30x1,5 FL Yes Yes 460x600x1346 186 400;3~N;50 AIR 5 32 R 539.0006 unistat 380<br />

35 0.8 M30x1,5 FL Yes Yes 460x600x1346 190 400;3~N;50 WATER 5 32 1/2“ R 540.0006 unistat 380w<br />

30 0.8 M30x1,5 FL Yes Yes 460x600x1346 190 400;3~N;50 AIR 5 32 R 537.0006 unistat 380 HT<br />

30 0.8 M30x1,5 FL Yes Yes 460x600x1346 190 400;3~N;50 WATER 5 32 1/2“ R 538.0006 unistat 380w HT<br />

30 0.8 M30x1,5 FL Yes Yes 1200x650x740 190 400;3~N;50 WATER 5 32 1/2“ R 538.0006FB unistat 380w HT-FB<br />

30 0.8 M30x1,5 FL Yes Yes 460x600x1346 208 400;3~N;50 AIR 5 32 R 548.0006 unistat 385<br />

30 0.8 M30x1,5 FL Yes Yes 460x600x1346 204 400;3~N;50 WATER 5 32 1/2“ R 549.0006 unistat 385w<br />

30 0.8 M30x1,5 FL Yes Yes 1200x650x740 234 400;3~N;50 WATER 5 30 1/2“ R 549.0005FB unistat 385w-FB<br />

30 0.8 M30x1,5 FL Yes Yes 460x600x1346 212 400;3~N;50 AIR 5 32 R 546.0006 unistat 385 HT<br />

30 0.8 M30x1,5 FL Yes Yes 460x600x1346 212 400;3~N;50 WATER 5 32 1/2“ R 547.0006 unistat 385w HT<br />

32 0.8 M30x1,5 FL Yes Yes 540x650x1490 245 400;3~N;50 AIR 5 32 R 721.0002 unistat 386<br />

32 0.8 M30x1,5 FL Yes Yes 540x650x1490 238 400;3~N;50 WATER 5 32 1/2“ R 722.0002 unistat 386w<br />

40 1.5 M30x1,5 FL Yes Yes 600x700x1560 390 400;3~N;50 WATER 5 32 1/2“ R 554.0005 unistat 390w<br />

35 1.5 M30x1,5 FL Yes Yes 600x700x1560 424 400;3~N;50 WATER 5 32 1/2“ R 553.0005 unistat 390w HT<br />

57 1.3 M38x1,5 FL Yes Yes 920x1200x1655 995 400;3~;50 WATER 5 32 3/4“ R 558.0003 unistat 290w<br />

80 2.5 M38x1,5 FL Yes Yes 920x1200x1655 991 400;3~;50 WATER 5 32 3/4“ R 705.0001 unistat 291w<br />

100 2.5 1 1/4“ FL Yes Yes 1700x3500x1850 2100 400;3~;50 AIR 5 32 R 706.0001 unistat 292<br />

100 2.5 1 1/4“ FL Yes Yes 2400x1200x1750 1950 400;3~;50 WATER 5 32 1“ R 706.0002 unistat 292w<br />

18 0.7 M16x1 FL Yes Yes 700x800x1515 355 400;3~;50 WATER 5 32 1/2“ R 543.0004 unistat 420w<br />

16 0.7 M16x1 FL Yes Yes 700x800x1515 390 400;3~;50 WATER 5 32 1/2“ R 541.0004 unistat 420w HT<br />

44 1.5 M30x1,5 FL Yes Yes 920x1200x1655 685 400;3~;50 WATER 5 32 1/2“ R 707.0001 unistat 421w<br />

FL Yes Yes 585x425x550 73 230;50 AIR 5 32 R 665.0004 CAL 1<br />

FL Yes Yes 585x425x550 71 230;50 AIR 5 32 R 665.0005 CAL 2<br />

FL Yes Yes 585x560x550 128 230;50 AIR 5 32 R 665.0003 CAL 3<br />

FL Yes Yes 585x355x550 49 230;50 5 32 665.0006 CAL 4<br />

12 0.2 0.1 M16x1 Yes No No 225x360x380 23 230;50/60 AIR 5 32 R 466.0010 minichiller<br />

12 0.2 0.1 M16x1 Yes No No 225x360x380 23 230;50 WATER 5 32 1/2“ R 466.0020 minichiller w<br />

12 0.2 0.1 M16x1 Yes NFL No No 225x360x380 23 230;50/60 AIR 5 32 O 466.0011 minichiller-1<br />

12 0.2 0.1 M16x1 Yes NFL No No 225x360x380 23 230;50 WATER 5 32 1/2“ O 466.0021 minichiller w-1<br />

18 0.5 M16x1 A NFL No Yes 277x500x425 37 230;50 AIR 5 32 O 576.0031 UC006A-1<br />

22 3.0 M16x1 B No No 320x500x493 41 230;50 AIR 5 32 O 576.0050 UC007<br />

Weight<br />

min. Ambient Temperature<br />

max. Ambient Temperature<br />

Natural Refrigerant**<br />

Cat.No.<br />

Cooling Water Connection<br />

22 3.0 M16x1 B NFL No Yes 320x500x493 41 230;50 AIR 5 32 O 576.0051 UC007-1<br />

25 3.0 M16x1 B NFL No Yes 410x480x540 52 230;50 AIR 5 32 O 677.0021 UC015-1<br />

25 3.0 M16x1 B NFL No Yes 410x480x540 53 230;50 WATER 5 32 1/2“ O 677.0031 UC015w-1<br />

25 3.0 3/4“ B NFL No Yes 460x510x755 78 400;3~N;50 AIR 5 32 O 670.0031 UC022-1<br />

25 3.0 3/4“ B NFL No Yes 460x510x755 93 400;3~N;50 WATER 5 32 1/2“ O 670.0041 UC022w-1<br />

25 3.0 3/4“ B NFL No Yes 460x510x755 76 400;3~N;50 AIR 5 32 O 672.0031 UC020-1<br />

25 3.0 3/4“ B NFL No Yes 460x510x755 73 400;3~N;50 WATER 5 32 1/2“ O 672.0041 UC020w-1<br />

* Voltage can be changed, must be specified with order ** S = Standard, O = Option, R = on Request<br />

www.huber-online.com · Tel. +49-781-96030<br />

Model<br />

55


TECHNICAL DATA<br />

Model<br />

Catalogue Page<br />

Temperature Range<br />

Tmin with cooling<br />

Heating Power<br />

Tmin with water cooling<br />

Bath Volume<br />

min. Filling Capacity<br />

Bath Volume with<br />

Displacement Insert<br />

Bath Opening WxDxH<br />

Resolution of Display<br />

UC025-1 38 -10...40 0,8 0.1 0.5 2<br />

UC025w-1 38 -10...40 0.8 0.1 0.5 2<br />

UC006T-1 40 -25...40 1.25 0.1 0.5 0.45 0.07<br />

UC009T-1 40 -25...40 1.25 0.1 0.5 0.7 0.25<br />

UC012T-1 40 -25...40 1.25 0.1 0.5 1 0.4<br />

UC016T-1 40 -10...40 2.5 0.1 0.5 0.9<br />

UC020T-1 40 -20...40 2.5 0.1 0.5 2 0.5<br />

UC025T-1 40 -10...40 2.5 0.1 0.5 1.2<br />

UC040T-1 40 -10...40 2.1 0.1 0.5 2.2<br />

UC045T-1 40 -20...40 2 0.1 0.5 4.3 1.5<br />

UC055T-1 40 -10...40 5 0.1 0.5 3<br />

UC060T-1 40 -20...40 5 0.1 0.5 6 1.5<br />

UC080T-1 40 -10...40 5 0.1 0.5 4.8<br />

UC100T-4 40 -20...40 8.36 0.1 0.5 10 2.5<br />

UC110T-4 40 -10...40 8.36 0.1 0.5 6<br />

UC130T-4 40 -10...40 8.36 0.1 0.5 7.2<br />

UC150T-4 40 -20...40 17 0.1 0.5 15 3.7<br />

UC160T-4 40 -10...40 17 0.1 0.5 8.8<br />

UC200T-4 40 -10...40 17 0.1 0.5 11<br />

UC210T-4 40 -20...40 17 0.1 0.5 21 5.2<br />

UC250T-4 40 -10...40 20 0.1 0.5 14<br />

UC260T-4 40 -20...40 20 0.1 0.5 26 5.2<br />

UC300T-4 40 -10...40 25 0.1 0.5 16.5<br />

UC400T-4 40 -10...40 25 0.1 0.5 22<br />

UC006Tw-1 41 -20...40 1.25 0.1 0.5 0.45 0.25<br />

UC009Tw-1 41 -25...40 1.25 0.1 0.5 0.7 0.2<br />

UC012Tw-1 41 -25...40 1.25 0.1 0.5 1 0.3<br />

UC015Tw-1 41 -25...40 1.55 0.1 0.5 1.2 0.4<br />

UC023Tw-1 41 -25...40 1.55 0.1 0.5 1.6 0.5<br />

UC016Tw-1 41 -10...40 2.5 0.1 0.5 0.9<br />

UC020Tw-1 41 -20...40 2.5 0.1 0.5 2 0.5<br />

UC025Tw-1 41 -10...40 2.5 0.1 0.5 1.2 0.1<br />

UC030Tw-1 41 -20...40 2.5 0.1 0.5 3 1<br />

UC040Tw-1 41 -10...40 2.5 0.1 0.5 2.1<br />

UC055Tw-1 41 -10...40 5.9 0.1 0.5 4<br />

UC060Tw-1 41 -20...40 5.9 0.1 0.5 6 1.4<br />

UC080Tw-1 41 -10...40 5.9 0.1 0.5 4.65<br />

UC100Tw-4 41 -20...40 6.5 0.1 0.5 10 3<br />

UC110Tw-4 41 -10...40 6.5 0.1 0.5 5.8<br />

UC130Tw-4 41 -10...40 6.5 0.1 0.5 7<br />

UC150Tw-4 41 -20...40 11 0.1 0.5 15 5<br />

UC160Tw-4 41 -10...40 11 0.1 0.5 9.5<br />

UC200Tw-4 41 -10...40 11 0.1 0.5 10.7<br />

UC210Tw-4 41 -20...40 12.3 0.1 0.5 21 10<br />

UC250Tw-4 41 -10...40 12.3 0.1 0.5 13.6<br />

UC260Tw-4 41 -20...40 12.3 0.1 0.5 26 12<br />

UC300Tw-4 41 -10...40 12.3 0.1 0.5 16<br />

UC400Tw-4 41 -10...40 18 0.1 0.5 21<br />

UC500Tw-4 41 -10...40 25 0.1 0.5 26<br />

Unichiller ETH-1 wl 42 -10...40 5.2 0.1 0.5 2<br />

Rotacool 42 -20...40 1.5 0.1 1 0.3<br />

Cooling Power at<br />

Temperature Stability<br />

300°C<br />

200°C<br />

100°C<br />

20°C<br />

0°C<br />

-20°C<br />

-40°C<br />

-60°C<br />

-80°C<br />

-100°C<br />

°C °C °C kW l l l mm K K kW kW kW kW kW kW kW kW kW kW<br />

Models with CC1 controller: Technical Data remains identical with controller change (CC2, CC3) FL = Suitable for inflammable and non-inflammable fluids<br />

56 www.huber-online.com · Tel. +49-781-96030


max. Flow Rate - Pressure Pump<br />

max. Press - Pressure Pump<br />

max. Flow Rate - Suction Pump<br />

max. Press - Suction Pump<br />

Pump Connection<br />

Circulation Pump<br />

Safety Standard<br />

Low Level Protection<br />

Overtemperature Protection<br />

Dimensions WxDxH<br />

TECHNICAL DATA<br />

Power supply<br />

Cooling of refrigeration machine<br />

l/min bar l/min bar mm kg V; Hz °C °C<br />

Weight<br />

min. Ambient Temperature<br />

max. Ambient Temperature<br />

Natural Refrigerant**<br />

Cat.No.<br />

Cooling Water Connection<br />

25 3.0 3/4“ B NFL No Yes 460x615x755 88 400;3~N;50 AIR 5 32 O 674.0041 UC025-1<br />

26.5 3.5 3/4“ B NFL No Yes 460x510x755 88 400;3~N;50 WATER 5 32 1/2“ O 674.0051 UC025w-1<br />

30 0.7 M16x1 A NFL No No 350x310x615 40 230;50 AIR 5 32 O 582.0011 UC006T-1<br />

30 0.7 M16x1 A NFL No No 350x310x615 41 230;50 AIR 5 32 O 584.0011 UC009T-1<br />

30 0.7 M16x1 A NFL No No 350x310x615 44 230;50 AIR 5 32 O 586.0011 UC012T-1<br />

22 3.0 1 1/4“ B NFL No Yes 450x510x1160 114 230;50 AIR 5 32 O 587.0011 UC016T-1<br />

22 3.0 3/4“ B NFL No Yes 450x510x1160 130 230;50 AIR 5 32 O 588.0011 UC020T-1<br />

22 3.0 3/4“ B NFL No Yes 450x510x1160 119 230;50 AIR 5 32 O 589.0011 UC025T-1<br />

22 3.0 3/4“ B NFL No Yes 500x550x1265 110 400;3~N;50 AIR 5 32 O 590.0011 UC040T-1<br />

22 3.0 3/4“ B NFL No Yes 500x550x1265 164 400;3~N;50 AIR 5 32 O 591.0011 UC045T-1<br />

65 4.0 1 1/4“ C3 NFL No Yes 600x630x1600 175 400;3~N;50 AIR 5 32 O 592.0011 UC055T-1<br />

65 4.0 1 1/4“ C3 NFL No Yes 600x630x1570 199 400;3~N;50 AIR 5 32 O 593.0011 UC060T-1<br />

65 4.0 1 1/4“ C3 NFL No Yes 600x730x1570 223 400;3~N;50 AIR 5 32 O 594.0011 UC080T-1<br />

65 4.0 1 1/4“ C3 NFL No Yes 600x790x1570 230 400;3~N;50 AIR 5 32 O 595.0006 UC100T-4<br />

65 4.0 1 1/4“ C3 NFL No Yes 600x790x1570 230 400;3~N;50 AIR 5 32 R 596.0006 UC110T-4<br />

65 4.0 1 1/4“ C3 NFL No Yes 874x1185x1870 480 400;3~N;50 AIR 5 32 R 597.0006 UC130T-4<br />

140 4.0 1 1/4“ D3 NFL No Yes 874x1485x1870 480 400;3~N;50 AIR 5 32 R 598.0005 UC150T-4<br />

140 4.0 1 1/4“ D3 NFL No Yes 874x1185x1870 235 400;3~N;50 AIR 5 32 R 600.0005 UC160T-4<br />

140 4.0 1 1/4“ D3 NFL No Yes 874x1465x1870 480 400;3~N;50 AIR 5 32 R 601.0005 UC200T-4<br />

140 4.0 1 1/4“ D3 NFL No Yes 874x1985x1870 430 400;3~N;50 AIR 5 32 R 602.0005 UC210T-4<br />

140 4.0 1 1/4“ D3 NFL No Yes 874x1985x1870 430 400;3~N;50 AIR 5 32 R 603.0005 UC250T-4<br />

140 4.0 1 1/4“ D3 NFL No Yes 874x1985x1870 430 400;3~N;50 AIR 5 32 R 604.0005 UC260T-4<br />

140 4.0 1 1/4“ D3 NFL No Yes 874x1985x1870 450 400;3~N;50 AIR 5 32 R 605.0005 UC300T-4<br />

140 4.0 1 1/4“ D3 NFL No Yes 2500x1685x1800 480 400;3~N;50 AIR 5 32 R 650.0005 UC400T-4<br />

30 0.7 M16x1 A NFL No Yes 230x280x550 30 230;50 WATER 5 40 1/2“ O 606.0031 UC006Tw-1<br />

30 0.7 M16x1 A NFL No Yes 230x280x550 32 230;50 WATER 5 40 1/2“ O 607.0031 UC009Tw-1<br />

30 0.7 M16x1 A NFL No Yes 350x310x615 40 230;50 WATER 5 40 1/2“ O 611.0011 UC012Tw-1<br />

30 0.7 M16x1 A NFL No Yes 350x310x615 43 230;50 WATER 5 40 1/2“ O 613.0011 UC015Tw-1<br />

30 0.7 M16x1 A NFL No Yes 350x310x615 50 230;50 WATER 5 40 1/2“ O 615.0011 UC023Tw-1<br />

22 3.0 3/4“ B NFL No Yes 400x440x1100 96 230;50 WATER 5 40 1/2“ O 616.0011 UC016Tw-1<br />

22 3.0 3/4“ B NFL No Yes 400x440x1100 109 230;50 WATER 5 40 1/2“ O 617.0011 UC020Tw-1<br />

22 3.0 3/4“ B NFL No Yes 400x440x1100 97 230;50 WATER 5 40 1/2“ O 618.0011 UC025Tw-1<br />

22 3.0 3/4“ B NFL No Yes 400x440x1100 115 400;3~N;50 WATER 5 40 1/2“ O 619.0011 UC030Tw-1<br />

22 3.0 3/4“ B NFL No Yes 400x440x1100 110 400;3~N;50 WATER 5 40 1/2“ O 620.0011 UC040Tw-1<br />

65 4.0 1 1/4“ C3 NFL No Yes 500x550x1265 168 400;3~N;50 WATER 5 40 1/2“ O 621.0011 UC055Tw-1<br />

65 4.0 1 1/4“ C3 NFL No Yes 500x550x1265 173 400;3~N;50 WATER 5 40 1/2“ O 622.0011 UC060Tw-1<br />

65 4.0 1 1/4“ C3 NFL No Yes 500x550x1265 225 400;3~N;50 WATER 5 40 1/2“ O 623.0011 UC080Tw-1<br />

90 5.5 1 1/4“ C3 NFL No Yes 600x600x1450 230 400;3~N;50 WATER 5 40 1/2“ O 624.0005 UC100Tw-4<br />

65 4.0 1 1/4“ C3 NFL No Yes 600x600x1450 230 400;3~N;50 WATER 5 40 1/2“ R 625.0005 UC110Tw-4<br />

65 4.0 1 1/4“ C3 NFL No Yes 600x600x1450 370 400;3~N;50 WATER 5 40 1/2“ R 626.0005 UC130Tw-4<br />

140 4.0 1 1/4“ D3 NFL No Yes 760x800x1560 370 400;3~N;50 WATER 5 40 1/2“ R 627.0005 UC150Tw-4<br />

140 4.0 1 1/4“ D3 NFL No Yes 600x600x1450 235 400;3~N;50 WATER 5 40 1/2“ R 628.0005 UC160Tw-4<br />

140 4.0 1 1/4“ D3 NFL No Yes 760x800x1560 430 400;3~N;50 WATER 5 40 3/4“ R 629.0005 UC200Tw-4<br />

140 4.0 1 1/4“ D3 NFL No Yes 760x800x1560 430 400;3~N;50 WATER 5 40 1/2“ R 630.0007 UC210Tw-4<br />

140 4.0 1 1/4“ D3 NFL No Yes 760x800x1560 430 400;3~N;50 WATER 5 40 3/4“ R 631.0005 UC250Tw-4<br />

140 4.0 1 1/4“ D3 NFL No Yes 760x800x1560 430 400;3~N;50 WATER 5 40 3/4“ R 632.0005 UC260Tw-4<br />

140 4.0 1 1/4“ D3 NFL No Yes 760x800x1560 450 400;3~N;50 WATER 5 40 3/4“ R 633.0005 UC300Tw-4<br />

140 4.0 1 1/4“ D3 NFL No Yes 1000x920x1665 480 400;3~N;50 WATER 5 40 3/4“ R 634.0005 UC400Tw-4<br />

140 4.0 1 1/4“ D3 NFL No Yes 1000x920x1665 520 400;3~N;50 WATER 5 40 1/2“ R 635.0005 UC500Tw-4<br />

30 1.4 3/4“ Yes NFL No Yes 460x615x760 93 400;3~N;50 AIR+WATER 5 32 1/2“ R 673.0011 Unichiller ETH-1 wl<br />

10 0.2 M16x1 Yes No Yes 470x580x420 32 230;50/60 AIR 5 32 O 659.0001 Rotacool<br />

* Voltage can be changed, must be specified with order ** S = Standard, O = Option, R = on Request<br />

www.huber-online.com · Tel. +49-781-96030<br />

Model<br />

57


TECHNICAL DATA<br />

Model<br />

SPECIALS<br />

Catalogue Page<br />

Temperature Range<br />

Tmin with cooling<br />

Tmin with water cooling<br />

Heating Power<br />

Bath Volume<br />

min. Filling Capacity<br />

Bath Volume with<br />

Displacement Insert<br />

Bath Opening WxDxH<br />

°C °C °C kW l l l mm K K kW kW kW kW kW kW kW kW kW kW<br />

Hotbox HB1-1 44 45...250 4.5 3.5 0.1<br />

Hotbox HB2-1 44 60...250 6 3.5 0.1<br />

Hotbox HB3-1 44 60...250 6 3.5 0.1<br />

Hotbox HB4-1 44 25...250 12 3.5 0.1<br />

Hotbox HB5-1 44 25...250 12 3.5 0.1<br />

Resolution of Display<br />

BFT1-2 44 0...80 2 22 8.5 280x280x150 0.1 0.02 1<br />

BFT1w-2 44 0...80 2 22 280x280x150 0.1 0.02 1<br />

BFT2-2 44 0...80 3 90 530x400x360 0.1 0.02 2.5<br />

BFT2w-2 44 0...80 3 90 530x400x360 0.1 0.02 2.5<br />

Cooling Power at<br />

Temperature Stability<br />

300°C<br />

200°C<br />

100°C<br />

20°C<br />

0°C<br />

-20°C<br />

-40°C<br />

-60°C<br />

-80°C<br />

-100°C<br />

Models with CC1 controller: Technical Data remains identical with controller change (CC2, CC3) FL = Suitable for inflammable and non-inflammable fluids<br />

58 www.huber-online.com · Tel. +49-781-96030


max. Flow Rate - Pressure Pump<br />

max. Press - Pressure Pump<br />

max. Flow Rate - Suction Pump<br />

max. Press - Suction Pump<br />

Pump Connection<br />

Circulation Pump<br />

Safety Standard<br />

Overtemperature Protection<br />

Low Level Protection<br />

Dimensions WxDxH<br />

l/min bar l/min bar mm kg V; Hz °C °C °C<br />

TECHNICAL DATA<br />

Weight<br />

Power supply<br />

min. Ambient Temperature<br />

Cooling of refrigeration machine<br />

max. Ambient Temperature<br />

Cooling Water Connection<br />

Natural Refrigerant**<br />

Cat.No.<br />

M16x1 FL Yes Yes 180x430x360 19 400;3~N;50 5 32 290.0051 Hotbox HB1-1<br />

M16x1 FL Yes Yes 455x320x500 50 400;3~N;50 5 32 290.0061 Hotbox HB2-1<br />

80 1.6 M30x1,5 FL Yes Yes 455x320x500 44 400;3~N;50 5 32 290.0071 Hotbox HB3-1<br />

M30x1,5 FL Yes Yes 455x320x500 44 400;3~N;50 5 32 290.0081 Hotbox HB4-1<br />

M30x1,5 FL Yes Yes 455x320x500 50 400;3~N;50 5 32 290.0091 Hotbox HB5-1<br />

FL Yes Yes 420x590x700 70 230;50 AIR 5 32 O 569.0005 BFT1-2<br />

FL Yes Yes 420x590x700 70 230;50 WATER 5 32 1/2“ O 569.0006 BFT1w-2<br />

FL Yes Yes 670x720x1070 116 400;3~N;50 AIR 5 32 O 249.0005 BFT2-2<br />

FL Yes Yes 670x720x1070 116 400;3~N;50 WATER 5 32 1/2“ O 249.0006 BFT2w-2<br />

* Voltage can be changed, must be specified with order ** S = Standard, O = Option, R = on Request<br />

www.huber-online.com · Tel. +49-781-96030<br />

Model<br />

59


GLOSSARY<br />

AAmbient Temperature<br />

Range<br />

Ambient Temperature Range is the permissible<br />

temperature range of the environment<br />

in which the unit will function. lt is 5...32°C<br />

for all Huber units in this catalogue. The<br />

quoted cooling powers are for an ambient<br />

temperature of 20°C.<br />

Automatic<br />

Compressor Control<br />

Is a procedure used in refrigeration machines<br />

to save energy. A microprocessor<br />

control decides if the refrigeration machine<br />

is required or if it can be switched off.<br />

Automatic Cooling Capacity<br />

Control<br />

is a control routine to save energy. The microprocessor<br />

based controller determines<br />

whether it is possible to reduce the cooling<br />

power. In addition to saving energy, this<br />

also saves wear and tear of the compressor,<br />

reduces the amount of heat discharged<br />

into the environment, and gives better temperature<br />

control.<br />

CCalibration<br />

Thermostat (CAL)<br />

is a bath thermostat with especially <strong>high</strong><br />

temperature stability and especially consistent<br />

temperature distribution through<br />

the bath.<br />

DDischarge Pressure<br />

is the positive pressure of the circulating<br />

pump of a thermostat directly at the pump<br />

discharge. lf only one value is given in the<br />

tables, then this involves the maximum<br />

B<br />

delivery pressure for flow rate zero. Pump<br />

Bath/Circulation<br />

curves illustrate discharge in relation to the<br />

Thermostat<br />

flow rate.<br />

is a thermostat with a bath opening which<br />

is allows objects to be directly thermoregu-<br />

E<br />

lated in the bath as well as a pump (Com- Extended Working<br />

patible Control thermostats have pressure Temperature Range<br />

and suction pump) for closed (pressure Extended Working Temperature Range is<br />

pump) and open (suction and pressure the temperature range that can be attained<br />

pumps) external circuits.<br />

when using a factory-fitted cooling coil<br />

when operating with cooling water.<br />

Bath Opening<br />

is the usable surface that is available for<br />

direct <strong>thermoregulation</strong>, as a rule over the<br />

entire usable depth.<br />

Bath Thermostat<br />

is a thermostat which is equipped with a<br />

pump and a bath that contains the object<br />

to be thermoregulated. The built-in circulating<br />

pump is used to mix the bath liquid,<br />

but can also be used if necessary to circulate<br />

the thermofluid through an externally<br />

connected circuit, e.g. connection of<br />

a through-flow cooler to allow the cooling<br />

of heating thermostats.<br />

Bath Volume<br />

(also fill volume)<br />

is the volume of the bath liquid that is<br />

required for adequate operation of the<br />

thermostat, but without considering the<br />

volume of thermofluid in the external circuit.<br />

lf two values are given, the lower<br />

value indicates the minimum required vol-<br />

60 www.huber-online.com · Tel. +49-781-96030<br />

ume with displacement insert, the upper<br />

value the permissible maximum amount.<br />

The difference is the so-called expansion<br />

volume. Especially in the case of external<br />

applications, the size of the expansion tank<br />

must be considered, since the circulating<br />

thermostat must also take up the expansion<br />

of the liquid in the external circuit. The<br />

smaller the surface area of the expansion<br />

tank the lower is the area of thermofluid<br />

open to attack from oxidation and air humidity<br />

absorption.<br />

Clear-view Thermostat<br />

is a bath thermostat with transparent walls<br />

for direct observation of the object being<br />

thermoregulated.<br />

FFlow Rate<br />

is the volume of liquid delivered per time<br />

unit by the circulating pump measured with<br />

water. If only one value is given in the table,<br />

this is the maximum flow rate for a zero<br />

discharge pressure. Pump curves illustrate<br />

discharge in relation to the flow rate.<br />

HHeat Load<br />

is the maximum capacity of the installed<br />

N<br />

electric heater. The heating is controlled Net Cooling Capacity<br />

proportionally. The heating is continually is the effective capacity available in refrig-<br />

controlled, and as the set point temperaeration thermostats or circulating chillers.<br />

ture is approached the power is reduced This is the net cooling power of the unit<br />

automatically.<br />

after the frictional heat produced by the<br />

circulating pump and the heat entering as<br />

a result of non-ideal insulation has been<br />

subtracted.<br />

Heating Thermostat<br />

is a thermostat whose working temperature<br />

range is primarily above the ambient<br />

temperature adds heat to the thermofluid.<br />

I O<br />

lmmersion Cooler<br />

is an additional chiller with a flexible tube<br />

and a cooling coil (evaporator) for immersion<br />

cooling of any desired bath.<br />

lmmersion Thermostat<br />

is a thermostat that can be combined with<br />

a bath and to form a complete unit. Immersion<br />

thermostats are equipped with a screw<br />

clamp to attach them to any desired bath<br />

wall or can be fixed on a stand. Immersion<br />

thermostats can also be fitted to a bridge<br />

and mounted permanently in a bath.<br />

Industrial Thermostats<br />

(UC-Hx)<br />

are refrigerated circulators (Unichiller<br />

range) with factory fitted heating. The<br />

units have <strong>high</strong> cooling, heating and<br />

pump powers which allow quick cooling<br />

and heating rates due to the small<br />

internal volumes. They are ideal for<br />

temperature control in process technology,<br />

within a smaller temperature range<br />

(-20..120°C).<br />

Interface, analogue<br />

is used to input the set value or to output<br />

the actual value of temperature in analogue<br />

form, generally in the form of a current<br />

(4...20 mA).<br />

Interface, digital<br />

is used to transfer data between connected<br />

units in digital form via data cable. The set<br />

and actual temperature values are the main<br />

items transferred. The serial RS 232 interface<br />

allows a point-to-point connection.<br />

This means that at anyone time only two<br />

participants such as the thermostat and the<br />

PC can communicate with each other via<br />

the interface. The RS 485 interface is an<br />

addressable interface where up to 32 participants<br />

can be connected. Each participant<br />

of the bus system has its address.<br />

Intrinsic Temperature<br />

is the operating temperature of a heating<br />

thermostat that is reached when the heating<br />

is switched off. lt depends on the pump<br />

power, thermofluid (viscosity and density)<br />

used and the insulation of the thermostat,<br />

e.g. with or without a cover on the bath.<br />

Operating Temperature<br />

Range<br />

Operating Temperature Range is the temperature<br />

range that is limited by the permissible<br />

lowest and <strong>high</strong>est operating<br />

temperatures.


P<br />

Pressure Pump<br />

is used for circulation of the thermofluid in<br />

an external closed circuit and in the bath.<br />

Pressure/Suction Pump<br />

This pump has a pressure and a suction<br />

stage which are driven by the same motor.<br />

The thermofluid is delivered from the<br />

pressure stage from the thermostat into<br />

the circuit, and the suction stage draws<br />

the liquid back into the thermostat. A pressure/suction<br />

pump can be used in just the<br />

same way as a pressure pump for a closed<br />

circuit. lt has the advantage compared to<br />

a pressure pump that the pressure in the<br />

external circuit falls from positive values<br />

(pressure) in the flow line and to negative<br />

values (suction) in the return line and is almost<br />

zero in the application itself. Thus it is<br />

suitable for the <strong>thermoregulation</strong> of pressure-sensitive<br />

glass vessels. Additionally<br />

it is possible to thermoregulate an open<br />

external circuit (e.g. a bath) with the aid of<br />

a pressure/suction pump. This cannot be<br />

done with a pure pressure pump, since this<br />

delivers thermofluid to the bath. The thermofluid<br />

can only be returned to the bath<br />

via a suction stage. In any case a so-called<br />

constant Ievel device is required to maintain<br />

a constant level in the bath and this<br />

ensures that the flows of both pump stages<br />

are controlled so that they are equal. This<br />

is the only way that the Ievel in the external<br />

bath can be maintained constant.<br />

TTemperature Constance<br />

is half of the temperature difference between<br />

the <strong>high</strong>est and bowest temperatures<br />

which are measured for a specific set<br />

point after attaining a stable value over a<br />

30 minute period. The details are quoted for<br />

70°C (using water) for a heating thermostat<br />

and at -10°C (using ethanol) for a cooling<br />

thermostat (see also DIN 12876).<br />

WWorking Temperature<br />

Range<br />

Working Temperature Range is the temperature<br />

range which can be attained at an<br />

ambient temperature of 20°C by the thermostat<br />

alone and with the exclusive use of<br />

electrical energy. In the case of a heating<br />

thermostat the working temperature begins<br />

above room temperature (as a result<br />

of the energy introduced by the pump and<br />

the effective insulation) and ends at the upper<br />

limit of the operating temperature. The<br />

WTR of a refrigeration thermostat begins<br />

with the lowest operating temperature of<br />

the unit and finishes with the upper temperature<br />

at which the refrigeration machine<br />

can permanently operate.<br />

SSafety Classes<br />

lt is possible to use non-flammable or flammable<br />

bath liquids with thermostats. The<br />

relevant safety requirements are given in<br />

DIN EN 61010-2-010. There is a distinction<br />

made between the NFL classes with built-in<br />

over-heating protection that are exclusively<br />

for non-flammable liquids and FL (Flammable)<br />

with adjustable overtemperature<br />

protection and bw level protection for flam-<br />

RRecirculation Thermostat mable liquids (all Huber thermostats).<br />

(Unistats)<br />

Is a thermostat in which thermofluid is<br />

pumped through an open or closed external<br />

circuit. Recirculation thermostats e.g.<br />

the Unistats can have a thermally discoupled<br />

expansion vessel, whose surface temperature<br />

is not the operating temperature.<br />

They do not have an accessible bath. Unistats<br />

have a thermally discoupled active<br />

surface (expansion vessel), where by the<br />

surface temperature is not necessarily the<br />

same as the operating temperature.<br />

Process Control<br />

Often cascade control, is when the temperature<br />

control is dictated by the temperature<br />

of the connected external application.<br />

A temperature sensor (often a Pt100 4 wire<br />

configuration with a Lemosa plug) is therefore<br />

required in the external application,<br />

which is connected to the thermostat. The<br />

actual value measured at the external application<br />

is measured and a set point for<br />

the thermostat is continually calculated.<br />

Depending on the operating temperature,<br />

insulation losses and exothermic reactions,<br />

the bath temperature and thus the<br />

flow temperature of the thermostat can be<br />

considerably above or below the set point.<br />

(Always consider the safety limits of the<br />

fluid!!)<br />

Refrigerated Circulator<br />

is a special cooling thermostat which is designed<br />

exclusively as a circulation thermostat.<br />

Circulation chillers have evolved from<br />

thermostats and form a separate range of<br />

units in terms of their type of construction<br />

(DeskTop, Tower), the cooling and pump<br />

capacities. Generally they have no accessible<br />

bath. They are often used as a substitute<br />

for cooling with tap water. (exception:<br />

minichiller)<br />

Refrigerated/Heating<br />

Thermostat<br />

is a thermostat whose working temperature<br />

range is above and below the ambient<br />

temperature, and which can either add heat<br />

to or extract heat from the bath liquid.<br />

Refrigerant<br />

This is used in the refrigeration unit within<br />

the thermostat and extracts the heat from<br />

the thermoregulating liquid, when the<br />

compressed gas expands in the evaporator.<br />

Huber has been completely CFC free<br />

since 1992 and HCFC (e.g. R22) free since<br />

1994. Huber uses only refrigerants which<br />

do no damage to the ozone layer (ODP<br />

Ozone Depletion Potential, ODP=0), and<br />

minimal Global warming potential (GWP,<br />

i.e. Green house effect).<br />

Refrigerated Thermostat<br />

is a thermostat whose working temperature<br />

range is below the ambient temperature<br />

and draws heat from the thermofluid.<br />

Huber refrigerated thermostats are strictly<br />

speaking cooling/heating thermostats,<br />

since their working temperature range is<br />

above and below the ambient temperature.<br />

Heat can be extracted from and added to<br />

the thermofluid.<br />

Standards<br />

The safety requirements for electrical<br />

Iaboratory equipment, and especially also<br />

those for thermostats, have been defined<br />

in European standards EN 61010-1 and EN<br />

61010-2-01 0, replacement for DIN 12879,<br />

among others. The terms and characteristic<br />

of characteristic data is defined in DIN<br />

12876-1 and DIN 12876-2.<br />

Suction Pressure<br />

is the negative pressure of the circulating<br />

pump of a thermostat directly at the pump<br />

suction. lf only one value is given in the<br />

GLOSSARY<br />

tables, then this involves the maximum<br />

suction pressure for zero flow rate. Pump<br />

curves illustrate suction pressure in relation<br />

to the flow rate.<br />

Through-flow Coolers (DC)<br />

are add-on coolers which are connected<br />

into an external circuit to upgrade a heating<br />

thermostat to a heating/cooling thermostat.<br />

They are used to replace water<br />

cooling, and also to extend the Iower operating<br />

temperature.<br />

www.huber-online.com · Tel. +49-781-96030<br />

61


GENERAL<br />

Hotline<br />

Have you a <strong>thermoregulation</strong> problem<br />

or questions relating to our<br />

products? You can contact us Mon-<br />

day to Friday from 7:30 to 18:00<br />

(CET).<br />

Hotline: +49-781-9603-244<br />

3-2-1 Warranty<br />

on Registration<br />

Many years experience with minimal<br />

failures have allowed us to<br />

extend our warranty conditions.<br />

Since the 1.1.2000 we have extended<br />

our warranty on the refrigeration<br />

system to 2 years.<br />

If you register your unit serial<br />

number with us (in writing), you<br />

will receive the following warranty<br />

conditions:<br />

3 Years warranty on exchangeable<br />

electronic controllers (Plug & Play),<br />

2 Years warranty on the refrige-<br />

ration technology (including compressors)<br />

and 1 Year warranty on<br />

the mechanical and electrical components.<br />

Please register your unit under<br />

SERVICE at www.huber-online.<br />

com or by Fax +49-781-57211,<br />

the warranty period starts on the<br />

dispatch date (ex works). Please<br />

note that these extended warranty<br />

conditions will not necessarily be<br />

adopted by our foreign service<br />

partners. Please speak to our distributors<br />

regarding the conditions<br />

being offered.<br />

We reserve the right to change<br />

specification at any time.<br />

We accept no liability for printing<br />

errors.<br />

62 www.huber-online.com · Tel. +49-781-96030<br />

Extract from the<br />

General Terms and<br />

Conditions<br />

Validity<br />

By placing the order the purchaser<br />

accepts the Sales, Delivery and<br />

Payment Terms of Peter Huber<br />

Kältemaschinenbau GmbH (www.<br />

huber-online.com). The specific<br />

delivery conditions are detailed in<br />

the Confirmation of Order issued<br />

by Huber.<br />

Payment Terms<br />

If pro forma payment has not been<br />

agreed, invoices are all payable<br />

within 30 days net, no discount.<br />

Delivery<br />

Delivery is always ex-works; we reserve<br />

the right to supply the goods<br />

via a third party.<br />

Transport / Transport Damage-<br />

The transport of goods is always<br />

ordered by the purchaser. Should<br />

loss or damage be incurred during<br />

transport the purchaser must contact<br />

the transport company and request<br />

that the goods are inspected<br />

by a loss adjuster, in advance of an<br />

insurance claim.<br />

Faults<br />

The purchaser must check the<br />

goods immediately on receipt, if<br />

any problems are discovered details<br />

should be forwarded to the<br />

Peter Huber Kältemaschinenbau<br />

GmbH within 5 days of receipt. If<br />

the complaint is upheld by Peter<br />

Huber Kältemaschinenbau GmbH<br />

the purchaser is entitled to claim<br />

a repair or replacement part. The<br />

purchaser can only claim damages,<br />

when he can prove that the<br />

Peter Huber Kältemaschinenbau<br />

GmbH has been grossly negligent.<br />

Claims for loss of profit will not be<br />

considered.<br />

Sale or Return of Goods<br />

If goods which have been dispatched<br />

on a sale or return basis are<br />

not returned within the agreed<br />

period the goods are then considered<br />

to be sold. If no return date<br />

is issued, it is considered to be 4<br />

weeks. The date is calculated from<br />

the date on the delivery note.<br />

Retention of Title<br />

The delivered goods shall remain<br />

the property of the Peter Huber<br />

Kältemaschinenbau GmbH until<br />

all claims against the purchaser<br />

arising from the business association<br />

have been settled.<br />

Redemption in acc. with WEEE /<br />

ElektroG (German law on electric<br />

and electronic devices)<br />

The sales prices are valid exclusive<br />

of the costs for the redemption and<br />

disposal of old devices from users<br />

other than private households.<br />

Upon request, the supplier shall<br />

also organize the redemption and<br />

recycling/disposal of such devices<br />

against compensation of the accrueing<br />

costs, given such devices are<br />

distributed by the supplier.<br />

Validity of Contract<br />

If a clause of these conditions is<br />

unworkable, the validity of the<br />

other clauses is unaffected. If one<br />

of the clauses has an unworkable<br />

section, the remainder of the clause<br />

will remain valid. The parties<br />

involved are bound to agree a<br />

replacement clause, with a similar<br />

function.


NOTES


<strong>high</strong> <strong>precision</strong> <strong>thermoregulation</strong><br />

Peter Huber Kältemaschinenbau GmbH<br />

Werner-von-Siemens-Straße 1<br />

D-77656 Offenburg /Germany<br />

Tel. +49-781-96030 · Fax +49-781-57211<br />

E-Mail: info@huber-online.com<br />

Internet: www.huber-online.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!