high precision thermoregulation - CMS
high precision thermoregulation - CMS
high precision thermoregulation - CMS
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>high</strong> <strong>precision</strong> <strong>thermoregulation</strong><br />
Catalogue 2006
EDITORIAL<br />
What a great day!<br />
Many thanks! Your wanting to discover<br />
more about our current product range,<br />
by reading this catalogue makes this a<br />
great day!<br />
The focus of our product development<br />
is centred on process requirements for<br />
<strong>thermoregulation</strong>. Our target of remaining<br />
the leaders in environmentally-friendly<br />
refrigeration and thermal control<br />
is reflected in the catalogue.<br />
Our early and voluntary decision to<br />
cease using CFC and HCFC refrigerants<br />
in 1994 has been followed by our recent<br />
decision and ability to offer refrigeration<br />
machines that use ZERO impact refrigerants<br />
(natural refrigerants).<br />
Precise <strong>thermoregulation</strong>: The range,<br />
over 500 models wide, offers various<br />
models of cooling and heating circulators.<br />
Varying cooling and heating powers<br />
of between 0.1 kW and 130 kW with a<br />
temperature range from -120°C to 400°C<br />
guarantees that we have a product that is<br />
perfect for your application/process.<br />
We have separated the product range<br />
into three groups.<br />
1. Convential bath-circulators:<br />
the Compatible Control Range<br />
2. Hydraulically sealed circulators:<br />
the Unistats<br />
3. Chillers: the Minichillers, Unichillers<br />
Our convential bath-circulators are<br />
named „Compatible Control“ range because<br />
of their unique electronic controllers<br />
which can be freely exchanged between<br />
models. The simple models have<br />
a pressure pump and are typically used<br />
for the temperature control of objects<br />
in their bath. By using a pump adaptor<br />
they become an economical solution<br />
for the <strong>thermoregulation</strong> of small externally-closed<br />
systems (refractometers,<br />
viscometers etc.). The more sophisticated<br />
Compatible Control circulators have<br />
a <strong>high</strong> performance variable-speed<br />
pump. When used in conjunction with<br />
an optional pressure sensor, the output<br />
maximum pump pressure can be regulated.<br />
The suffix „vpc“ (Variable Pressure<br />
Control) identifies these models.<br />
In 1990, the Tango Technology and Unistats<br />
began to dominate process thermal<br />
control. Now, over fifty models allow the<br />
same thermal regulation concept to be<br />
employed from drug discovery through<br />
scale-up, pilot plant to production. Highly<br />
efficient thermal transfer capability of<br />
the unique design provides the fastest<br />
ramp rates and responses to changing<br />
thermal loads during reactions and<br />
crystallisation processes. This results in<br />
faster process times and replication of<br />
results leading to <strong>high</strong>er yields, greater<br />
purity and consumption of fewer resources.<br />
Operational safety is foremost.<br />
The Tango Technology‘s ability to transfer<br />
thermal energy makes it the safest<br />
choice and only reliable choice to control<br />
a fast-running exothermic reaction.<br />
Standing still is a backward step for us.<br />
Through your feedback we have further<br />
developed the Tango Technology. Since<br />
its conception more than fifteen years<br />
ago, the next generation of Unistats, forged<br />
in experience and driven by results<br />
is now available. The Tango Nuevo is<br />
the New Dimension! You will find more<br />
information on the „Nuevo“ at the end<br />
of the Unistat chapter.<br />
Last but not least, you will find a wide<br />
assortment of air- and water-cooled<br />
Chillers, the „Unichillers“. Unichillers<br />
have the task of removing process heat.<br />
Expensive mains-supplied cooling water<br />
is replaced by mechanically-cooled,<br />
circulating water systems. The payback<br />
time is often only a few years and, depending<br />
on operation and cost structures,<br />
may sometimes be only a few months.<br />
Unichillers can be fitted with an optional<br />
heater for operation at <strong>high</strong>er temperatures.<br />
More in-depth technical information on<br />
the products can be found at the back of<br />
the catalogue.<br />
We look forward to receiving your questions<br />
and further requests.<br />
... have a great day!<br />
Daniel Huber
Compatible Control Thermostats<br />
Huber Software<br />
SpyLight 24<br />
SpyWatch 24<br />
SpyControl 24<br />
Unistats with Tango Technology<br />
Introduction, Concept 25<br />
The Tango Technology explained 28<br />
Unistat Range 29<br />
Calibration Baths, Specials, Unistat Nuevo 34<br />
Accessories 36<br />
Unichillers<br />
Introduction, Concept 37<br />
Bench Top models 38<br />
Tower Casing models 39<br />
Unichiller ETH, Rotacool 42<br />
Accessories 43<br />
Specials<br />
Hotbox 44<br />
Beer „Force Ageing“ Thermostats 44<br />
Accessories<br />
Thermal Fluids 45<br />
Adapters, Tubing 46<br />
Quick Finder<br />
Quick Finder Thermostats 48<br />
Quick Finder Chillers 49<br />
Technical Data<br />
Technical Data 50<br />
Glossary<br />
Thermodynamic Terms explained 60<br />
General<br />
CONTENTS<br />
Introduction, Concept 4<br />
Heating Bath Thermostats 7<br />
Cooling Bath Thermostats 11<br />
Ministat Family 14<br />
Accessories 19<br />
Hotline-Service 62<br />
3-2-1 Warranty 62<br />
Extract from Terms and Conditions 62
ompatible<br />
ontrol Thermostats<br />
Thermostat<br />
Plug & Play<br />
New in Blue, „Plug and<br />
Advances in microprocessor and display technologies<br />
together with feedback from our customer and user<br />
base has driven us to take our controllers to a new level<br />
of functionality.<br />
4 www.huber-online.com · Tel. +49-781-96030
Plug & Play<br />
3 Years<br />
Warranty<br />
ompatible<br />
It‘s so easy ontrol Thermostats<br />
Thermostat<br />
The controllers are microprocessor<br />
based and have all of the features that<br />
are expected but we would like to concentrate<br />
on what the controllers have<br />
that brings a unique dimension of flexibility<br />
and functionality to your laboratory.<br />
Differentiating facts<br />
– 3-year replacement warranty<br />
– User level and password protected<br />
Administrator level. The Administrator<br />
level allows the Administrator to lockout<br />
functions that are not required or<br />
should not be accessed by the operator<br />
– A uniformity of operation means that<br />
you only need to know how to drive one<br />
controller to know how to drive all three<br />
controllers and the equipment to which<br />
they are fitted.<br />
– The controllers are fitted with an encoder<br />
that the user “turns to search and<br />
pushes to select” the required menu option.<br />
– A full text alphabetically arranged<br />
user menu makes the new controllers<br />
intuitively easier to operate.<br />
Controller Options<br />
Play“ Technology<br />
Interchangeable controllers through “Plug & Play” technology<br />
– The controllers are not an “integral”<br />
part of the machine that they are fitted<br />
to. They can be exchanged by simply<br />
un-plugging the current controller and<br />
plugging in a new one.<br />
The display can be customised to show<br />
as much information as the user requires<br />
… from simply the bath temperature to<br />
a real time “program progress” display.<br />
Controller CC1 – Basic and practical<br />
New…User and Administrator levels<br />
New…Digital encoder “turn to search -<br />
push to select”<br />
New…48 character, 4-line LCD display<br />
New…Full character user menu<br />
Visual and audible alarms<br />
Also includes programmable alarm functions<br />
Microprocessor based controller ... and more.<br />
Controller CC2 – External process oriented<br />
All that the CC1 is furnished with plus<br />
Process control capability, Ramping function,<br />
5-step internal programmer ... and more.<br />
Controller CC3 – Automation capable<br />
All that the CC2 is furnished with plus<br />
10-program, 50 step internal programmer<br />
RS232, RS485 and analogue interfaces<br />
... and more.<br />
www.huber-online.com · Tel. +49-781-96030<br />
5
ompatible<br />
ontrol Thermostats<br />
Thermostat<br />
Concept<br />
Simple, Functional,<br />
Flexible and Robust<br />
Temperature control with in-built flexible control options to address applications and<br />
processes not yet thought of! The principle of Plug-and-Play technology has given our<br />
customers the ability to swap or upgrade systems since 1980.<br />
Because you cannot predict the future,<br />
controllers with Plug-and-Play technology<br />
enable you to adapt to it. The Huber<br />
“Compatible Controllers” fitted to our<br />
thermostats, circulators and chillers are<br />
fully interchangeable with each other.<br />
Upgrading to more features or ease of<br />
support will never be simpler.<br />
The Environment Fully Protected<br />
All Huber refrigeration machines are<br />
CFC and HCFC free. We also are able to<br />
offer refrigeration machines with natural<br />
refrigerants which have ZERO IMPACT<br />
on the environment.<br />
Plug & Play Technology<br />
The CC1, CC2 and CC3 controllers are<br />
fully interchangeable by the user. Designed<br />
for post sale flexibility and support,<br />
they provide the user with varying<br />
control options easily accessed through<br />
an intuitive menu driven display. The<br />
Ministat range offers this flexibility with<br />
the added advantage giving powerful<br />
heating and cooling from an extremely<br />
compact design.<br />
General Purpose, Low Duty Thermostats<br />
Starting with units designed for general<br />
and simple thermal control applications<br />
in the temperature range of -30…200°C,<br />
the range offers options of available bath<br />
materials. Baths constructed from Polycarbonate<br />
(A-series) or stainless steel<br />
(B-series) are available. Baths with the<br />
6 www.huber-online.com · Tel. +49-781-96030<br />
VPC<br />
Variable Pressure<br />
Control New!<br />
Option: Natural<br />
Refrigerants<br />
refrigeration plant built in are also available<br />
(K-series).<br />
All of the units are designed and built<br />
to conform to DIN12876 and are fitted<br />
with “Run dry” protection and an adjustable<br />
independent “Over-Temperature”<br />
cut-out.<br />
VPC-Models for Higher Demands<br />
For more demanding applications, the<br />
“VPC“range provides more powerful<br />
heating and cooling over a wider temperature<br />
range (-90…300°C) together<br />
with powerful and adjustable pumps.<br />
(Pressure and suction)<br />
Constructed from robust stainless steel,<br />
the practical, functional and sturdy design<br />
gives an unrivalled functional longevity<br />
to these units.<br />
Available as either heating only or heating/cooling<br />
units, the VPC range offers<br />
cooling powers up to 7 kW @ 20°C and<br />
heating powers up to 4 kW. The functional<br />
design gives a further dimension<br />
of flexibility by allowing the use of a<br />
“Calibration Insert” or a “Displacement<br />
Insert” to tune the units to specific applications.<br />
Options for the VPC-range include<br />
“ComBox” (to NAMUR) communication<br />
system/protocol and an external pressure<br />
sensor.<br />
All of the units are designed and built<br />
to conform to DIN12876 and are fitted<br />
with “Run dry” protection and an adjustable<br />
independent “Over-Temperature”<br />
cut-out.<br />
Plug & Play<br />
3 Years<br />
Warranty<br />
VPC Facts<br />
Thermal Insulation<br />
The thermal insulation is constructed<br />
to be vapour-tight over the life of the<br />
unit. The bath and outer surfaces are<br />
welded directly together. No seals or<br />
gaskets. Everything is in one entire<br />
piece.<br />
Stainless Steel Construction<br />
Quality, functionality and longevity.<br />
Stainless steel is used throughout<br />
which makes them resistive to corrosion<br />
and easy to clean.<br />
High Watts/Litre Ratio [W/L]<br />
Faster response, quicker cooling, faster<br />
heating. Compact designs and low<br />
volume baths so that you get more of<br />
the power you paid for!.<br />
High Power Density [W/dm³]<br />
High cooling powers in compact cases<br />
means more power for less bench<br />
space consumed. The Ministats are<br />
the shining example here!<br />
Air-Cooled or Water-Cooled or both!<br />
Standard options are for air or water<br />
cooled refrigerated units. The “wl”<br />
versions have both so that rejected<br />
heat can help warm the lab in winter<br />
when in the air-cooled mode and in<br />
summer time, the rejected heat can be<br />
carried away when used in the watercooled<br />
mode.
Immersion Thermostats<br />
The CC-E Immersion Thermostats are<br />
the basis for many combinations using<br />
polycarbonate and stainless steel baths.<br />
In combination with a cooling both, exact<br />
and reproducible temperatures down<br />
to -30°C can be achieved.<br />
ompatible<br />
Heating Thermostats ontrol Thermostats<br />
Thermostat<br />
CC1-E<br />
Simple<br />
CC2-E<br />
Versatile<br />
CC3-E<br />
Interactive<br />
Model Temperature Temperature Heating Pressure Pump Safety Dimensions Cat.No. G Price<br />
Range Stability* Power max. Class** W x D x H / ID<br />
[°C] [K] [kW] [l/min] [bar] [mm]<br />
CC1-E (prev.: Polystat cc1) (-30) 25..200 0,02 2,0 10 0,2 FL, III 120x135x300/150 688.0051 1<br />
CC2-E (prev.: Polystat cc2) (-30) 25..200 0,02 2,0 10 0,2 FL, III 120x135x300/150 688.0052 1<br />
CC3-E (prev.: Polystat cc3) (-30) 25..200 0,02 2,0 10 0,2 FL, III 120x135x300/150 688.0053 1<br />
* to DIN 12876, measured in a stainless steel tank 12 litres ** FL for flammable liquids<br />
III = adjustable overtemperature protection and addition low-liquid level protection<br />
Bridge Thermostats<br />
The Bridge Thermostats have a “vpc“ variable speed pressure-suction<br />
pump. Models with larger heating capacities are<br />
available for use with large baths. The telescopic arm can be<br />
extended up to max. 880 mm, for use with wider baths.<br />
VPC<br />
Variable Pressure<br />
Control<br />
Model Temperature Heating Temperature Pump Data Cat.No. G Price<br />
Range Power Stability to max. Pressure max. Suction<br />
[°C] [kW] DIN 12876 [K] [l/min] [bar] [l/min] [bar]<br />
CC1-300B2X vpc (prev.: CC302BX-1) (-20)28..300 2,0 0,02 33 0,7 22 0,4 683.0011BX 1<br />
CC2-300B2X vpc (prev.: CC302BX-2) (-20)28..300 2,0 0,02 33 0,7 22 0,4 683.0012BX 1<br />
CC3-300B2X vpc (prev.: CC302BX-3) (-20)28..300 2,0 0,02 33 0,7 22 0,4 683.0013BX 1<br />
CC1-300B4X vpc (prev.: CC303BX-1) (-20)28..300 3,0/4,0 0,02 33 0,7 22 0,4 684.0011BX 1<br />
CC2-300B4X vpc (prev.: CC303BX-2) (-20)28..300 3,0/4,0 0,02 33 0,7 22 0,4 684.0012BX 1<br />
CC3-300B4X vpc (prev.: CC303BX-2) (-20)28..300 3,0/4,0 0,02 33 0,7 22 0,4 684.0013BX 1<br />
Accessories see page 19.., 45.. www.huber-online.com · Tel. +49-781-96030<br />
7
ompatible<br />
ontrol Thermostats<br />
Thermostat<br />
Heating Thermostats<br />
Heating Bath Thermostats with Polycarbonate bath<br />
The transparent polycarbonate baths are suitable for use up to 100°C. A CC-E Immersion Thermostat is mounted on the bath<br />
bridge for all models. With a pump adaptor, this combination can also be used with external, closed applications. The temperature<br />
stability, in accordance with DIN 12876, is 0.02K .<br />
CC3-118A<br />
CC1-111A CC3-105A<br />
CC2-107A<br />
CC1-106A<br />
Model Temperature Bath Bath Bath Opening Pressure Pump Dimensions Cat.No. G Price<br />
max. Volume Depth W x D max. W x D x H<br />
[°C] [ltr] [mm] [mm] [l/min] [bar] [mm]<br />
CC1-105A (prev.: Polystat A5-1) 100 5 150 120x110 10 0,2 132x280x320 405.0001 1<br />
CC2-105A (prev.: Polystat A5-2) 100 5 150 120x110 10 0,2 132x280x320 405.0002 1<br />
CC3-105A (prev.: Polystat A5-2) 100 5 150 120x110 10 0,2 132x280x320 405.0003 1<br />
CC1-106A (prev.: Polystat A6-1) 100 6 150 120x210 10 0,2 132x380x320 405.0011 1<br />
CC2-106A (prev.: Polystat A6-2) 100 6 150 120x210 10 0,2 132x380x320 405.0012 1<br />
CC3-106A (prev.: Polystat A6-3) 100 6 150 120x210 10 0,2 132x380x320 405.0013 1<br />
CC1-107A (prev.: Polystat A7-1) 100 7 150 120x310 10 0,2 132x480x320 405.0021 1<br />
CC2-107A (prev.: Polystat A7-2) 100 7 150 120x310 10 0,2 132x480x320 405.0022 1<br />
CC3-107A (prev.: Polystat A7-3) 100 7 150 120x310 10 0,2 132x480x320 405.0023 1<br />
CC1-111A (prev.: Polystat A11-1) 100 11 150 302x165 10 0,2 333x313x325 405.0031 1<br />
CC2-111A (prev.: Polystat A11-2) 100 11 150 302x165 10 0,2 333x313x325 405.0032 1<br />
CC3-111A (prev.: Polystat A11-3) 100 11 150 302x165 10 0,2 333x313x325 405.0033 1<br />
CC1-118A (prev.: Polystat A18-1) 100 18 150 302x325 10 0,2 333x473x325 405.0041 1<br />
CC2-118A (prev.: Polystat A18-2) 100 18 150 302x325 10 0,2 333x473x325 405.0042 1<br />
CC3-118A (prev.: Polystat A18-3) 100 18 150 302x325 10 0,2 333x473x325 405.0043 1<br />
CC1-130A Visco 3 80 31 370 90x90 10 0,2 500x200x560 405.0051 1<br />
CC2-130A Visco 3 80 31 370 90x90 10 0,2 500x200x560 405.0052 1<br />
CC3-130A Visco 3 80 31 370 90x90 10 0,2 500x200x560 405.0053 1<br />
CC1-130A Visco 5 80 31 370 Ø 51 10 0,2 500x200x560 405.0061 1<br />
CC2-130A Visco 5 80 31 370 Ø 51 10 0,2 500x200x560 405.0062 1<br />
CC3-130A Visco 5 80 31 370 Ø 51 10 0,2 500x200x560 405.0063 1<br />
Plug & Play<br />
3 Years<br />
Warranty<br />
8 www.huber-online.com · Tel. +49-781-96030 Accessories see page 19.., 45..
Heating Thermostats with Stainless steel bath<br />
ompatible<br />
Heating Thermostats ontrol Thermostats<br />
Thermostat<br />
The insulated stainless steel baths are suitable for use up to 200°C. All models have a bridge-mounted CC-E Immersion Thermostat.<br />
With a pump adaptor, this combination can also be used with external, closed applications. The temperature stability,<br />
in accordance with DIN 12876, is 0.02K.<br />
CC3-220B<br />
CC1-215B CC3-212B<br />
CC1-208B<br />
Model Temperature Bath Bath Bath Opening Pressure Pump Dimensions Cat.No. G Price<br />
max. Volume Depth W x D max. W x D x H<br />
[°C] [ltr] [mm] [mm] [l/min] [bar] [mm]<br />
CC1-208B (prev.: Polystat B8-1) 200 8,5 150 235x165 10 0,2 290x350x375 407.0001 1<br />
CC2-208B (prev.: Polystat B8-2) 200 8,5 150 235x165 10 0,2 290x350x375 407.0002 1<br />
CC3-208B (prev.: Polystat B8-3) 200 8,5 150 235x165 10 0,2 290x350x375 407.0003 1<br />
CC1-212B (prev.: Polystat B12-1) 200 12 150 295x193 10 0,2 350x375x375 407.0011 1<br />
CC2-212B (prev.: Polystat B12-2) 200 12 150 295x193 10 0,2 350x375x375 407.0012 1<br />
CC3-212B (prev.: Polystat B12-3) 200 12 150 295x193 10 0,2 350x375x375 407.0013 1<br />
CC1-215B (prev.: Polystat B15-1) 200 15 200 295x193 10 0,2 350x375x420 407.0021 1<br />
CC2-215B (prev.: Polystat B15-2) 200 15 200 295x193 10 0,2 350x375x420 407.0022 1<br />
CC3-215B (prev.: Polystat B15-3) 200 15 200 295x193 10 0,2 350x375x420 407.0023 1<br />
CC1-220B (prev.: Polystat B20-1) 200 20 150 295x370 10 0,2 350x555x375 407.0031 1<br />
CC2-220B (prev.: Polystat B20-2) 200 20 150 295x370 10 0,2 350x555x375 407.0032 1<br />
CC3-220B (prev.: Polystat B20-3) 200 20 150 295x370 10 0,2 350x555x375 407.0033 1<br />
CC1-225B (prev.: Polystat B25-1) 200 25 200 295x370 10 0,2 350x555x420 407.0041 1<br />
CC2-225B (prev.: Polystat B25-2) 200 25 200 295x370 10 0,2 350x555x420 407.0042 1<br />
CC3-225B (prev.: Polystat B25-3) 200 25 200 295x370 10 0,2 350x555x420 407.0043 1<br />
Accessories see page 19.., 45..<br />
www.huber-online.com · Tel. +49-781-96030<br />
9
ompatible<br />
ontrol Thermostats<br />
Thermostat<br />
Heating Circulation Thermostats<br />
Heating Thermostats<br />
Good things come in small packages! Thanks to<br />
their low bath volumes the CC202C and CC205B are<br />
especially suitable to control the temperature of small<br />
external application. The temperature of small objects<br />
can also be controlled by placing them directly in the<br />
bath of the CC202C. Both models are available in the<br />
variants: CC1 – simple; CC2 – comfortable; and CC3 –<br />
communications equipped. The maximum temperature<br />
is 200°C. The temperature stability, in accordance with<br />
DIN 12876, is 0.05K. CC3-205B<br />
CC2-202C<br />
Model Temperature Bath Bath Opening Heating Pressure Pump Dimensions Cat.No. G Price<br />
Range Depth W x D Power max. W x D x H<br />
[°C] [mm] [mm] [kW] [l/min] [bar] [mm]<br />
CC1-202C (prev.: Polystat 201-1) (-30)45..200 150 Ø25 2,0 10 0,2 150x215x350 685.0011 1<br />
CC2-202C (prev.: Polystat 201-2) (-30)45..200 150 Ø25 2,0 10 0,2 150x215x350 685.0012 1<br />
CC3-202C (prev.: Polystat 201-3) (-30)45..200 150 Ø25 2,0 10 0,2 150x215x350 685.0013 1<br />
CC1-205B (prev.: Polystat 202-1) (-30)45..200 150 105x90 2,0 10 0,2 150x285x350 686.0011 1<br />
CC2-205B (prev.: Polystat 202-2) (-30)45..200 150 105x90 2,0 10 0,2 150x285x350 686.0012 1<br />
CC3-205B (prev.: Polystat 202-3) (-30)45..200 150 105x90 2,0 10 0,2 150x285x350 686.0013 1<br />
Heating Bath- and Circulation thermostats<br />
Temperatures up to 300°C- the extremely compact models have the<br />
smoothly controllable “vpc” pressure and suction pump. The pump<br />
pressure can be controlled from the user-menu, using an optional pressure<br />
sensor, so protecting your glassware or other delicate apparatus<br />
from breakage.<br />
CC2-315B vpc<br />
CC3-308B vpc<br />
CC1-304B vpc<br />
CC315B vpc CC308B vpc CC304B vpc<br />
Bath Depth:<br />
200 mm<br />
Bath Depth:<br />
155 mm<br />
Bath Depth:<br />
145 mm<br />
Model Temperature Bath Heating Temperature Pump Data Cat.No. G Price<br />
Range Volume Power Stability to max. Pressure max. Suction<br />
[°C] [ltr] [kW] DIN 12876 [K] [l/min] [bar] [l/min] [bar]<br />
CC1-304B vpc (prev.: CC301-1) (-20)28..300 4,0 2,0 0,02 33 0,7 22 0,4 679.0001 1<br />
CC2-304B vpc (prev.: CC301-2) (-20)28..300 4,0 2,0 0,02 33 0,7 22 0,4 679.0002 1<br />
CC3-304B vpc (prev.: CC301-3) (-20)28..300 4,0 2,0 0,02 33 0,7 22 0,4 679.0003 1<br />
CC1-308B vpc (prev.: CC302-1) (-20)28..300 8,5/5,2* 3,0 0,02 33 0,7 22 0,4 683.0021 1<br />
CC2-308B vpc (prev.: CC302-2) (-20)28..300 8,5/5,2* 3,0 0,02 33 0,7 22 0,4 683.0022 1<br />
CC3-308B vpc (prev.: CC302-3) (-20)28..300 8,5/5,2* 3,0 0,02 33 0,7 22 0,4 683.0023 1<br />
CC1-315B vpc (prev.: CC303-1) (-20)28..300 15/8,5* 3,0/4,0 0,02 33 0,7 22 0,4 684.0011 1<br />
CC2-315B vpc (prev.: CC303-2) (-20)28..300 15/8,5* 3,0/4,0 0,02 33 0,7 22 0,4 684.0012 1<br />
CC3-315B vpc (prev.: CC303-3) (-20)28..300 15/8,5* 3,0/4,0 0,02 33 0,7 22 0,4 684.0013 1<br />
* with displacement insert<br />
405<br />
110<br />
130<br />
VPC<br />
Variable Pressure<br />
Control<br />
10 www.huber-online.com · Tel. +49-781-96030 Accessories see page 19.., 45..
Cooling Bath Thermostats<br />
CC2-K20<br />
ompatible<br />
Cooling Thermostats ontrol Thermostats<br />
Thermostat<br />
The combination of the CC-E immersion thermostat with an insulated cooling bath is the economical alternative for application<br />
temperatures from -20°C/-30°C to 200°C. With a pump adaptor (see accessories page 22) this combination can also be used for<br />
external, closed applications. Pump: maximum flow 10 l/min; maximum pressure 0.2 bar. The temperature stability, in accordance<br />
with DIN 12876, is 0.02K. Safety classification FL, III.<br />
CC3-K15<br />
Plug & Play<br />
3 Years<br />
Warranty<br />
Natural<br />
Refrigerants<br />
CC1-K12<br />
Model Temperature Bath Bath Bath Opening Cooling Power [kW] at Dimensions Cat.No. G Price<br />
Range Volume Depth W x D 0°C -10°C -20°C W x D x H<br />
[°C] [ltr] [mm] [mm] [mm]<br />
CC1-K12 (prev.: Polystat K12-1) -20..(50)200 12 150 295x193 0,18 0,1 – 350x558x375 653.0021 2<br />
CC2-K12 (prev.: Polystat K12-2) -20..(50)200 12 150 295x193 0,18 0,1 – 350x558x375 653.0022 2<br />
CC3-K12 (prev.: Polystat K12-3) -20..(50)200 12 150 295x193 0,18 0,1 – 350x558x375 653.0023 2<br />
CC1-K15 (prev.: Polystat K15-1) -20..(50)200 15 200 295x193 0,2 0,12 – 350x558x400 645.0031 2<br />
CC2-K15 (prev.: Polystat K15-2) -20..(50)200 15 200 295x193 0,2 0,12 – 350x558x400 645.0032 2<br />
CC3-K15 (prev.: Polystat K15-3) -20..(50)200 15 200 295x193 0,2 0,12 – 350x558x400 645.0033 2<br />
CC1-K20 (prev.: Polystat K20-1) -30..(50)200 20 150 295x370 0,35 0,3 0,21 350x558x530 646.0031 2<br />
CC2-K20 (prev.: Polystat K20-2) -30..(50)200 20 150 295x370 0,35 0,3 0,21 350x558x530 646.0032 2<br />
CC3-K20 (prev.: Polystat K20-3) -30..(50)200 20 150 295x370 0,35 0,3 0,21 350x558x530 646.0033 2<br />
CC1-K25 (prev.: Polystat K25-1) -30..(50)200 25 200 295x370 0,35 0,3 0,21 350x558x580 647.0031 2<br />
CC2-K25 (prev.: Polystat K25-2) -30..(50)200 25 200 295x370 0,35 0,3 0,21 350x558x580 647.0032 2<br />
CC3-K25 (prev.: Polystat K25-3) -30..(50)200 25 200 295x370 0,35 0,3 0,21 350x558x580 647.0033 2<br />
Accessories see page 19.., 45..<br />
www.huber-online.com · Tel. +49-781-96030<br />
11
ompatible<br />
ontrol Thermostats<br />
Thermostat<br />
Variostat cc –<br />
The Cooling and Heating Thermostat<br />
for variable bath sizes<br />
Unique in the world. The Variostat can control the<br />
temperature in any bath size from -30°C to 150°C.<br />
The single-minded construction allows the user the<br />
greatest flexibility. The smooth, controllable “vpc”<br />
pressure and suction pump, allows the circulation<br />
in any bath size to be optimally controlled. Also, the<br />
pump pressure to an external application can be precisely<br />
set and controlled, from the user-menu, using<br />
an optional pressure.<br />
Insulated baths made of stainless steel in three standard<br />
or custom dimensions. Fitted with a drain.<br />
Position 1 Position 2<br />
Cooling Thermostats<br />
Volume End Cooling Time* [min] Free Bath Opening [mm]<br />
Temperature with Ethanol to Position 1 Position 2<br />
[Litre] [°C] 0°C -10°C -20°C A1 B1 C1 A2 B2 C2<br />
5,5 -30 15 30 55 60 60 – 60 75 –<br />
11,0 -25 30 60 110 200 200 45 200 215 30<br />
22,0 -20 65 130 240 300 320 165 320 315 150<br />
* Cooling time, measured with 2/3 of bath covered<br />
Variostat Baths Bath Depth Bath Opening W x D Cat.No. G Price<br />
Standard* 5,5 Litre 165 mm 228x156 mm 6052 2<br />
11 Litre 165 mm 368x196 mm 6053 2<br />
22 Litre 165 mm 468x316 mm 6054 2<br />
Ball Valve M16x1 6091 1<br />
Insulated Cover for: Cat.No. G Price<br />
Bath 5,5 Litre 6176 2<br />
Bath 11 Litre 6178 2<br />
Bath 22 Litre 6180 2<br />
* Custom sizes on request<br />
Model Working Tem- Bath Heating Pump Data Cooling Power [kW] Dimensions Cat.No. G Price<br />
perature Range Volume Power max. Pressure max. Suction at [°C] W x D x H<br />
[°C] [ltr] [kW] [l/min] [bar] [l/min] [bar] 100 20 0 -20 -30 [mm]<br />
variostat cc-1 -30..150 variabel 1,0 18 0,6 12 0,3 0,3 0,3 0,2 0,12 0,03 183x455x395 654.0011 2<br />
3 controller options Temperature Stability to DIN 12876: 0,02 K<br />
12 www.huber-online.com · Tel. +49-781-96030<br />
Option:<br />
Natural<br />
Refrigerants<br />
(Page 50...)<br />
Accessories see page 19.., 45..
Cooling-Bath Thermostats<br />
Accessories see page 19.., 45..<br />
ompatible<br />
Cooling Thermostats ontrol Thermostats<br />
Thermostat<br />
The K6 Models are the compact cooling and heating bath thermostats for temperatures from -25°C to 200°C. Heating capacity<br />
2 kW. With the integrated pump adaptor, the combination of this miniature cooling bath and the CC-E immersion thermostat<br />
can alsp be used for external, closed applications. The K6 is the economical alternative to the Ministat 125 (page 14), the smallest<br />
cooling thermostat in the world. Bestseller since 1976. The small size and large capability of the Ministats, with variable<br />
speed pump, is captivating.<br />
CC1-K6 CC2-K6 CC3-K6<br />
Model Working Tem- Bath Bath Cooling Power [kW] Pressure Pump Dimensions Cat.No. G Price<br />
perature Range Volume Depth at [°C] max. W x D x H<br />
[°C] [ltr] [mm] 0 -10 -20 [l/min] [bar] [mm]<br />
CC1-K6 (prev.: Polystat K6-1) -25..200 4,5 150 0,15 0,1 0,05 10 0,2 210x370x535 666.0021 2<br />
CC2-K6 (prev.: Polystat K6-2) -25..200 4,5 150 0,15 0,1 0,05 10 0,2 210x370x535 666.0022 2<br />
CC3-K6 (prev.: Polystat K6-3) -25..200 4,5 150 0,15 0,1 0,05 10 0,2 210x370x535 666.0023 2<br />
Option:<br />
Natural<br />
Refrigerants<br />
(Page 50...)<br />
www.huber-online.com · Tel. +49-781-96030<br />
13
ompatible<br />
ontrol Thermostats<br />
Thermostat<br />
The Ministat Family<br />
– proves that size is no guarantee of power<br />
Pound for pound, the Ministat range is<br />
more powerful then any other thermostat<br />
in the world. Comfortable in all locations,<br />
it has proved especially useful<br />
when space is restricted such as fume<br />
cabinets or crowded benches.<br />
Robustness:<br />
– The case and base of the Ministats are<br />
completely manufactured from stainless<br />
steel.<br />
Choice of controller:<br />
– The controller available in 3 versions<br />
in the same way as the Polystat controllers.<br />
(Please see “Controller options”<br />
inset opposite).<br />
Application flexibility:<br />
– Air-cooled or water-cooled refrigeration<br />
machine<br />
– There is an adjustable pump fitted.<br />
– User fitted “Displacement Insert” reduces<br />
bath volume and directs power<br />
to the external application (Option)<br />
– User fitted “Calibration Insert” improves<br />
control stability to better than<br />
0,01K (DIN 12876) allows for labora-<br />
Ministats<br />
Model Working Tem- Bath Bath Heating Pump Data Cooling Power [kW] Cat.No. G Price<br />
perature Range Volume W x D / ID Power max. Pressure max. Suction at [°C]<br />
[°C] [ltr] [mm] [kW] [l/min] [bar] [l/min] [bar] 20 0 -20<br />
ministat 125-1 -25..150 2,75/1,3* 178x80/120 1,0 27 0,7 20 0,4 0,30 0,21 0,05 740.0001 2<br />
ministat 125-2 -25..150 2,75/1,3* 178x80/120 1,0 27 0,7 20 0,4 0,30 0,21 0,05 740.0002 2<br />
ministat 125-3 -25..150 2,75/1,3* 178x80/120 1,0 27 0,7 20 0,4 0,30 0,21 0,05 740.0003 2<br />
ministat 125w-1 -25..150 2,75/1,3* 178x80/120 1,0 27 0,7 20 0,4 0,30 0,20 0,10 740.0011 2<br />
ministat 125w-2 -25..150 2,75/1,3* 178x80/120 1,0 27 0,7 20 0,4 0,30 0,20 0,10 740.0012 2<br />
ministat 125w-3 -25..150 2,75/1,3* 178x80/120 1,0 27 0,7 20 0,4 0,30 0,20 0,10 740.0013 2<br />
ministat 230-1 -33..200 3,2/1,7* 170x83/135 2,0 27 0,7 20 0,4 0,40 0,35 0,25 741.0001 2<br />
ministat 230-2 -33..200 3,2/1,7* 170x83/135 2,0 27 0,7 20 0,4 0,40 0,35 0,25 741.0002 2<br />
ministat 230-3 -33..200 3,2/1,7* 170x83/135 2,0 27 0,7 20 0,4 0,40 0,35 0,25 741.0003 2<br />
ministat 230w-1 -33..200 3,2/1,7* 170x83/135 2,0 27 0,7 20 0,4 0,40 0,35 0,25 741.0011 2<br />
ministat 230w-2 -33..200 3,2/1,7* 170x83/135 2,0 27 0,7 20 0,4 0,40 0,35 0,25 741.0012 2<br />
ministat 230w-3 -33..200 3,2/1,7* 170x83/135 2,0 27 0,7 20 0,4 0,40 0,35 0,25 741.0013 2<br />
ministat 240-1 -40..200 4,9/2,8* 200x85/157 2,0 27 0,7 20 0,4 0,55 0,50 0,35 742.0001 2<br />
ministat 240-2 -40..200 4,9/2,8* 200x85/157 2,0 27 0,7 20 0,4 0,55 0,50 0,35 742.0002 2<br />
ministat 240-3 -40..200 4,9/2,8* 200x85/157 2,0 27 0,7 20 0,4 0,55 0,50 0,35 742.0003 2<br />
ministat 240w-1 -40..200 4,9/2,8* 200x85/157 2,0 27 0,7 20 0,4 0,55 0,50 0,35 742.0011 2<br />
ministat 240w-2 -40..200 4,9/2,8* 200x85/157 2,0 27 0,7 20 0,4 0,55 0,50 0,35 742.0012 2<br />
ministat 240w-3 -40..200 4,9/2,8* 200x85/157 2,0 27 0,7 20 0,4 0,55 0,50 0,35 742.0013 2<br />
* with displacement insert Temperature Stability to DIN 12876: 0,02 K<br />
14 www.huber-online.com · Tel. +49-781-96030<br />
tory based calibrations (Option)<br />
– Option: ComBox (NAMUR standard)<br />
The case and bath are pressed from the<br />
same sheet of stainless steel. This eliminates<br />
the need for a gasket between the<br />
bath and the frame.<br />
Thermal transfer from the bath to the<br />
outer casing is prevented by an innovative<br />
thermal control system that prevents<br />
build up of condensation around<br />
the bath opening when running cold and<br />
from heating up during <strong>high</strong> temperature<br />
operation.<br />
We have extend the original range of<br />
two popular laboratory workhorses to a<br />
family of five. The ministat and unistat<br />
cc have been joined by ministat 125, 230<br />
and 240.<br />
Three levels of interchangeable controllers<br />
offers the end-user a choice of<br />
features best suited to the demands of<br />
the application through Huber’s familiar<br />
“Plug and Play” technology. This maintains<br />
the ability for the user to easily upgrade<br />
controllers should the application<br />
demand it.<br />
Accessories see page 19.., 45..
Pressure/ bar<br />
0,8<br />
0,6<br />
0,4<br />
0,2<br />
0<br />
-0,2<br />
-0,4<br />
-0,6<br />
10 20<br />
Flow in l/min<br />
30<br />
Measured with water at 20˚C in accordance to DIN 12876<br />
225 225 mm mm<br />
Option:<br />
Natural<br />
Refrigerants<br />
(Page 50...)<br />
Accessories see page 19.., 45..<br />
370 370 mm mm<br />
360 mm<br />
ompatible<br />
Ministats ontrol Thermostats<br />
Thermostat<br />
255 255 mm mm<br />
450 mm<br />
400 mm<br />
VPC<br />
Variable Pressure<br />
Control<br />
300 300 mm mm<br />
www.huber-online.com · Tel. +49-781-96030<br />
465 mm<br />
455 mm<br />
15
ompatible<br />
ontrol Thermostats<br />
Thermostat<br />
Cooling and heating thermostats to -45°C<br />
Controller Options<br />
305 vpc<br />
Large bath volume<br />
Cooling Thermostats<br />
CC1: CC2: CC3:<br />
Basic and practical External process oriented Automation capable<br />
Please see page 6 for full details.<br />
405 vpc/w 415 vpc/wl, 505 vpc/wl<br />
410wl vpc<br />
Circulators with small volumes especially designed for external<br />
<strong>thermoregulation</strong> applications. Highest cooling power density and<br />
largest volume cooling capacity in their class.<br />
VPC<br />
Variable Pressure<br />
Control<br />
First bath circulator in the<br />
world with an air and water<br />
cooled refrigeration machine.<br />
Bath Depth: 150 mm Bath Depth: 150 mm Bath Depth: 150 mm Bath Depth: 200 mm<br />
Model (previous:) Working Tem- Bath Heating Pump Data Cooling Power [kW] Cat.No. G Price<br />
perature Range Volume Power max. Pressure max. Suction at [°C]<br />
[°C] [ltr] [kW] [l/min] [bar] [l/min] [bar] 100 20 0 -20 -30 -40<br />
CC1-305 vpc (CC130-1) -30..150 20 1,5 33 0,7 22 0,4 0,35 0,35 0,35 0,23 0,03 – 690.0011 2<br />
CC1-405 vpc (CC241-1) -40..200 5 1,5 33 0,7 22 0,4 0,7 0,7 0,7 0,45 0,18 0,03 697.0011 2<br />
CC1-405w vpc (CC241w-1) -40..200 5 1,5 33 0,7 22 0,4 0,7 0,7 0,7 0,45 0,18 0,03 697.0021 2<br />
CC1-415 vpc (CC240-1) -40..200 5 1,5 33 0,7 22 0,4 1,2 1,2 1,0 0,6 0,2 0,05 694.0011 2<br />
CC1-415wl vpc (CC240wl-1) -40..200 5 1,5 33 0,7 22 0,4 1,2 1,2 1,0 0,6 0,2 0,05 694.0021 3<br />
CC1-410wl vpc (CC245wl-1) -45..200 22/8,5* 1,5/4,5 33 0,7 22 0,4 0,8 0,8 0,8 0,5 0,15 0,1 695.0011 3<br />
Plug & Play<br />
3 Years<br />
Warranty<br />
3 controller options * with displacement insert Temperature Stability to DIN 12876: 0,02 K<br />
16 www.huber-online.com · Tel. +49-781-96030<br />
Option:<br />
Natural<br />
Refrigerants<br />
(Page 50...)<br />
Accessories see page 19.., 45..
Cooling and heating thermostats to -55°C<br />
Compact form and large cooling powers at low temperatures<br />
ompatible<br />
Cooling Thermostats ontrol Thermostats<br />
Thermostat<br />
510 vpc/w, 515w vpc 515 vpc, 905 vpc/w 520w vpc, 525w vpc,<br />
810 vpc/w<br />
Bath Depth: 200 mm Bath Depth: 200 mm Bath Depth: 200 mm<br />
Model (previous:) Working Tem- Bath Heating Pump Data Cooling Power [kW] Cat.No. G Price<br />
perature Range Volume Power max. Pressure max. Suction at [°C]<br />
[°C] [ltr] [kW] [l/min] [bar] [l/min] [bar] 100 20 0 -20 -40<br />
CC1-505 vpc (CC250-1) -50..200 5 1,5 33 0,7 22 0,4 1,2 1,2 1,0 0,6 0,15 696.0011 2<br />
CC1-505wl vpc (CC250wl-1) -50..200 5 1,5 33 0,7 22 0,4 1,2 1,2 1,0 0,6 0,15 696.0021 3<br />
CC1-510 vpc (CC150-1) -50..100 18/11* 3,0 31 0,6 24 0,35 2,1 2,1 2,1 1,0 0,4 564.0021 2<br />
CC1-510w vpc (CC150w-1) -50..100 18/11* 3,0 31 0,6 24 0,35 2,4 2,4 2,4 1,0 0,4 564.0031 2<br />
CC1-515 vpc (CC155-1) -55..100 26/15* 3,0 31 0,6 24 0,35 3,3 3,3 3,3 1,6 0,6 651.0011 2<br />
CC1-515w vpc (CC155w-1) -55..100 18/11* 3,0 31 0,6 24 0,35 3,3 3,3 3,3 1,6 0,6 651.0021 2<br />
CC1-520w vpc (CC156w-1) -55..100 17/10* 3,0 31 0,6 24 0,35 5,0 5,0 5,0 3,0 1,5 698.0011 3<br />
CC1-525w vpc (CC157w-1) -55..100 17/10* 3,0 31 0,6 24 0,35 7,0 7,0 5,0 3,0 1,5 700.0001 3<br />
3 controller options * with displacement insert Temperature Stability to DIN 12876: 0,02 K<br />
Accessories see page 19.., 45..<br />
www.huber-online.com · Tel. +49-781-96030<br />
Option:<br />
Natural<br />
Refrigerants<br />
(Page 50...)<br />
17
ompatible<br />
ontrol Thermostats<br />
Thermostat<br />
Cooling and heating thermostats to -90°C<br />
705 vpc, 805 vpc 815 vpc<br />
Lower price alternative to the CC820 vpc for<br />
low temperatures, when low cooling power is<br />
adequate<br />
Bath Depth: 150 mm Bath Depth: 150 mm<br />
Cooling Thermostats<br />
Plug & Play<br />
3 Years<br />
Warranty<br />
VPC<br />
Variable Pressure<br />
Control<br />
Model (previous:) Working Tem- Bath Heating Pump Data Cooling Power [kW] Cat.No. G Price<br />
perature Range Volume Power max. Pressure max. Suction at [°C]<br />
[°C] [ltr] [kW] [l/min] [bar] [l/min] [bar] 100 20 0 -20 -40 -60<br />
CC1-705 vpc (CC175-1) -75..100 5 1,5 33 0,7 22 0,4 0,25 0,25 0,25 0,2 0,15 0,1 692.0011 2<br />
CC1-805 vpc (CC180-1) -80..100 5 1,5 33 0,7 22 0,4 0,5 0,5 0,5 0,4 0,3 0,3 693.0011 2<br />
CC1-820 vpc (CC181-1) -80..100 17/10* 3,0 31 0,6 24 0,35 1,2 1,2 1,2 1,1 0,9 0,6 567.0021 3<br />
CC1-820w vpc (CC181w-1) -80..100 17/10* 3,0 31 0,6 24 0,35 1,2 1,2 1,2 1,1 0,9 0,6 567.0031 3<br />
CC1-815 vpc (CC185-1) -85..100 5 1,5 33 0,7 22 0,4 1,0 1,0 1,0 0,8 0,75 0,6 699.0001 3<br />
CC1-905 vpc (CC190-1) -90..100 26/15* 3,0 31 0,6 24 0,35 2,0 2,0 2,0 1,9 1,7 1,0 568.0011 3<br />
CC1-905w vpc (CC190w-1) -90..100 26/15* 3,0 31 0,6 24 0,35 2,0 2,0 2,0 1,9 1,7 1,0 568.0021 3<br />
3 controller options * with displacement insert Temperature Stability to DIN 12876: 0,02 K<br />
18 www.huber-online.com · Tel. +49-781-96030<br />
Pressure/ bar<br />
Pump Data VPC models<br />
Pressure/ bar<br />
0,8<br />
0,6<br />
0,4<br />
0,2<br />
0<br />
-0,2<br />
-0,4<br />
-0,6<br />
0 10 20 30<br />
Flow in l/min<br />
Measured with water at 20˚C in accordance to DIN 12876<br />
0,8<br />
0,6<br />
0,4<br />
0,2<br />
0<br />
-0,2<br />
-0,4<br />
Option:<br />
-0,6<br />
0 10 20 30<br />
Natural<br />
Refrigerants<br />
(Page 50...)<br />
Flow in l/min<br />
Measured with water at 20˚C in accordance to DIN 12876<br />
Accessories see page 19.., 45..
Flow-through Chillers<br />
The “Flow-through Chillers” are designed for simple, low demand cooling applications.<br />
They are commonly used in combination with the CC202C or CC205B series<br />
to remove heat in order to cool a process back to room temperature.<br />
Model Working Cooling Power [kW] at Dimensions Cat.No. G Price<br />
Temperature Range 0°C -10°C -20°C W x D x H<br />
[°C] [mm]<br />
DC30 -30..50 0,2 0,15 0,07 190x250x360 574.0002 2<br />
DC31 -30..50 0,4 0,35 0,10 250x310x400 575.0002 2<br />
DC32 -30..50 0,6 0,47 0,12 280x340x460 652.0002 2<br />
Immersion Coolers<br />
„Dip“ or „Immersion“ coolers are ideal for simple cooling applications when low<br />
temperatures are required such as vapour traps or for cooling individual flasks.<br />
They are also commonly used to remove heat from the baths in the „A“ and<br />
„B“ series. The units with an “E” have the capability to control the temperature<br />
to a stability of +/- 0,5 K to DIN 12876. All models can be delivered with a flexible<br />
evaporator coil (no extra cost). The model name and Cat.No. get the addition „F“.<br />
Model Working Cooling Power [W] at Dimensions Cat.No. G Price<br />
Temperature Range 0°C -20°C -30°C W x D x H<br />
[°C] [mm]<br />
TC45 -45..100 240 180 100 190x250x360 570.0008 2<br />
TC45E -45..100 240 180 100 190x250x360 570.0009 2<br />
TC50 -50....50 300 260 200 250x310x400 572.0006 2<br />
TC50E -50....50 300 260 200 250x310x400 572.0007 2<br />
TC100 -100..40 150 140 125 280x440x525 573.0007 2<br />
ompatible<br />
Accessories ontrol Thermostats<br />
Thermostat<br />
TC100E -100..40 150 140 125 280x440x525 573.0008 2 TC45E<br />
Polycarbonate Baths<br />
All models are designed to operate up to a maximum temperature of 100°C.<br />
Model Bath Volume Dimensions Bath Depth Cat.No. G Price<br />
[ltr] W x D x H [mm] [mm]<br />
105A (prev.: A5) 5 132x280x161 150 6307 1<br />
106A (prev.: A6) 6 132x380x161 150 6006 1<br />
107A (prev.: A7) 7 132x480x161 150 6007 1<br />
111A (prev.: A11) 11 333x313x166 150 6008 1<br />
118A (prev.: A18) 18 333x473x166 150 6009 1<br />
Insulated Stainless Steel Baths<br />
All models are designed to operate up to a max temperature of 200°C.<br />
Model Bath Volume Dimensions Bath Dimensions Depth Cat.No. G Price<br />
(prev.:) [ltr] W x D x H [mm] W x D x H [mm] [mm]<br />
208B (E8) 8,5 290x350x215 235x295x150 150 6683 1<br />
212B (E12) 12 350x375x215 295x320x150 150 6684 1<br />
215B (E15) 15 350x375x260 295x320x200 200 6012 1<br />
220B (E20) 20 350x555x215 295x500x150 150 6685 1<br />
225B (E25) 25 350x555x260 295x500x200 200 6013 1<br />
118A<br />
106A<br />
Option:<br />
107A<br />
DC30<br />
Natural<br />
Refrigerants<br />
(Page 50...)<br />
www.huber-online.com · Tel. +49-781-96030<br />
105A<br />
111A<br />
Option:<br />
Natural<br />
Refrigerants<br />
(Page 50...)<br />
TC100E<br />
19
ompatible<br />
ontrol Thermostats<br />
Thermostat<br />
K20<br />
K15<br />
K12<br />
Bath Bridges<br />
Accessories<br />
Cold Baths<br />
Featured here are simply „cold baths“<br />
with volumes from 12 to 25 litres.<br />
These can be used in combination with<br />
an immersion heater or simply run at<br />
their lowest achievable temperature for<br />
use as a “plunge pool”.<br />
They are fully constructed from stainless<br />
steel.<br />
Model Temperature Range Bath Bath Bath Opening Cooling Power [kW] at Dimensions Cat.No. G Price<br />
Volume Depth W x D 0°C -10°C -20°C W x D x H<br />
[°C] [ltr] [mm] [mm] [mm]<br />
K12 -20..50(200) 12 150 295x320 0,18 0,1 350x558x215 653.0020 2<br />
K15 -20..50(200) 15 200 295x320 0,2 0,12 350x558x240 645.0021 2<br />
K20 -30..50(200) 20 150 295x500 0,35 0,3 0,21 350x558x370 646.0021 2<br />
K25 -30..50(200) 25 200 295x500 0,35 0,3 0,21 350x558x420 647.0021 2<br />
Model Cat.No. G Price<br />
Polycarbonate bath 105A, 106A, 107A 6309 1<br />
Polycarbonate bath 111A, 118A 6310 1<br />
Stainless steel bath 208B 6303 1<br />
Stainless steel bath 212B, 215B, 220B, 225B 6308 1<br />
Refrigerated bath K12, K15, K20, K25 6311 1<br />
Telescopic bridge for CC1-E to CC3-E extendible up to max. 640 mm 6306 1<br />
Bath Covers for stainless steel and refrigerated baths<br />
Model Cat.No. G Price<br />
Bath cover 208B 6214 1<br />
Bath cover front 212B-225B, K12-K25 6023 1<br />
Bath cover back 220B-225B, K20-K25 6024 1<br />
Bath cover one piece 220B-225B, K20-K25 6025 1<br />
20 litres and larger can be in one or two parts<br />
Adjustable Bases<br />
Available in 3 options<br />
20 www.huber-online.com · Tel. +49-781-96030<br />
Natural<br />
Refrigerants<br />
Model Cat.No. G Price<br />
Adjustable base for 118A 6328 1<br />
Adjustable base for 111A, 212B, 215B, K12, K15 6297 1<br />
Adjustable base for 220B, 225B, K20, K25 6298 1
Polycarbonate test tube racks<br />
for 105A to 107A<br />
Type Holes Immersion Depth [mm] Cat.No. G Price<br />
A 12 x Ø22 50 6028 1<br />
B 20 x Ø17 55 6029 1<br />
C 20 x Ø17 95 6030 1<br />
D 30 x Ø13 45 (Hemolyse) 6031 1<br />
E 6 x Ø30 50 6032 1<br />
F 36 x Ø10 25 (Eppendorf) 6033 1<br />
Stainless Steel test tube racks<br />
for 111A to 118A, 212B to 225B and refrigerated baths K12-K25<br />
Type Holes Immersion Depth [mm] Cat.No. G Price<br />
1 36 x Ø17 100 6037 1<br />
2 45 x Ø13 70 6038 1<br />
3 46 x Ø17 100 6039 1<br />
4 58 x Ø13 70 6040 1<br />
Trolleys<br />
The trolleys make the Compatible Control Thermostats mobile.<br />
Model Cat.No. G Price<br />
K20, K25, CC305 vpc 6334 2<br />
CC705 vpc, CC805 vpc, CC415 vpc, CC505 vpc 6235 2<br />
CC410wl vpc 6295 2<br />
Unipump (pressure booster)<br />
Made of stainless steel for temperatures from -120 to 300°C. To compensate for<br />
the pressure loss in external systems. The Unipump is connected in series with the<br />
pump of the compatible control thermostat and can be controlled via the volt free<br />
contact of the compatible con trol.<br />
Unipump I max. pressure increase Cat.No. G Price<br />
M16x1 [bar]<br />
Unipump I 0,5 527.0001 2<br />
Unipump I 2 stage 1,5 527.0002 2<br />
Control Cable Unipump I / CC (3m) 6222 1<br />
Controller<br />
Controller Cat.No. G Price<br />
Compatible Control Regler CC1 658.0001 1<br />
Compatible Control Regler CC2 658.0002 1<br />
Compatible Control Regler CC3 658.0003 1<br />
Ministat CC1 663.0011 2<br />
Ministat CC2 663.0012 2<br />
Ministat CC3 663.0013 2<br />
ompatible<br />
Accessories ontrol Thermostats<br />
Thermostat<br />
www.huber-online.com · Tel. +49-781-96030<br />
21
ompatible<br />
ontrol Thermostats<br />
External Pt100 sensors<br />
External Pt100 sensors for CC2 and CC3.<br />
For external <strong>thermoregulation</strong> applications,<br />
a range of sensors. Custom models<br />
available on request.<br />
Control cables<br />
Control cables (for CC3) allow remote<br />
control via the RS232, RS485 or the analogue<br />
interfaces (AIF). Open ends allow<br />
flexibility to connect as required.<br />
ComBox<br />
ComBox (NAMUR) with enhanced scope<br />
of functions. The ComBox communicates<br />
with the CC controller via the internal<br />
CAN bus, irrespective of whether the device<br />
is operated with a CC1, CC2 or CC3<br />
controller.<br />
Accessories<br />
Sensors (standard cable length 1,5 m) Cat.No. G Price<br />
Ø 6 mm 180 mm 6138 1<br />
with handle Ø 6 mm 200 mm 6105 1<br />
Ø 8 mm 400 mm 6064 1<br />
mounted in protective pipe Ø 8 mm 170 mm 6205 1<br />
M16x1 sensor for flow or return 6352 1<br />
M16x1 sensor for flow or return double 6353 1<br />
Extension cable Pt100, 3m 6292 1<br />
ComBox Cat.No. G Price<br />
ComBox (NAMUR) Ministate, CC intern 6779 1<br />
Remote control Remote control Cat.No. G Price<br />
Other accessories<br />
6301<br />
6300<br />
6839<br />
6305<br />
6304<br />
22 www.huber-online.com · Tel. +49-781-96030<br />
Control cables Compatible Control Cat.No. G Price<br />
CC RS232 / PC RS232 (3m) 6198 1<br />
CC RS485 / open (3m) 6236 1<br />
CC AIF / POKO open (3m) 6218 1<br />
CC AIF / open (3m) 6320 1<br />
CC complete / open (3m) 6319 1<br />
Y cable PC / AIF 6651 1<br />
15-pole plug (plug only, no cable) 6335 1<br />
for all CC thermostats with controller CC3 6734 1<br />
Other accessories Cat.No. G Price<br />
Holder for TC45(E)-TC100(E) evaporator to be fixed to bath bridge 6022 1<br />
Drain cock with cap 6839 1<br />
Pump adapter for CC1-E to CC3-E, 111A to 118A, 208B to 225B, K12 to K25 6300 1<br />
Pump adapter for 105A to 107A 6304 1<br />
Cooling coil for CC1-E to CC3-E, 111A to 118A, 208B to 225B 6301 1<br />
Cooling coil for 105A to 107A 6305 1<br />
Tripod bar for CC1-E, CC2-E, CC3-E 6302 1<br />
Trolley K20, K25, CC305 vpc 6334 2<br />
Displacement insert for CC205B 6041 1
Calibration inserts<br />
Calibration insert Cat.No. G Price<br />
ministat 125 6806 2<br />
ministat 230 6807 2<br />
ministat 240 6808 2<br />
CC410wl vpc 6294 2<br />
CC505wl vpc - CC520w vpc,<br />
CC810 vpc 6496 2<br />
CC515 vpc, CC905 vpc 6150 2<br />
CC308B vpc 6325 1<br />
CC315B vpc 6126 1<br />
Measuring method<br />
The temperature constancy specified in<br />
the technical data is measured in accordance<br />
as follows:<br />
The sensor of the test thermo meter is<br />
located in the centre of the bath and at<br />
half the overall depth. The preconditioning<br />
time (τ) of the sensor is 5 or 6 seconds<br />
at most. Heating thermostats are<br />
evaluated using water at a tem perature<br />
of 70°C cooling thermo stats using alcohol<br />
at a tem perature of -10°C.<br />
Heating thermostats are opera ted under<br />
load so that a so-called typical cooling<br />
water current has to flow. In cooling<br />
thermostats a load of this kind is generated<br />
by the pump and transmission<br />
due to the temperature diffe rence be-<br />
A<br />
B<br />
ompatible<br />
Accessories ontrol Thermostats<br />
Thermostat<br />
tween the environment and<br />
-10°C. A control sensor with<br />
=5 seconds would be far too<br />
sluggish for a thermostat. We<br />
use sensors with approx. 1.5<br />
seconds. You will therefore<br />
see a greater fluctuation on<br />
the digital actual value display<br />
than corresponds to the<br />
measurement in the centre of<br />
the bath.<br />
Thermostats<br />
as calibration baths<br />
Thermostats are also used as<br />
calibrating baths. However, if<br />
you wish to test tem perature<br />
sensors using a small mass,<br />
for example, the following<br />
may occur:<br />
The calibrating sensor ( = 5 s)<br />
is in the centre of the bath and<br />
shows a fluctu ation of 0.01K.<br />
The test piece A is lo cated directly adjacent<br />
to this, the test piece B is in one<br />
corner of the bath and the test piece C<br />
in the other corner.<br />
The absolute heat capacity of the test object<br />
(the mass) is perhaps less and the<br />
heat transmission (surface times value)<br />
possibly greater than that of the calibrating<br />
sensor, and an unknown temperature<br />
gradient exists in the bath. In this<br />
case each test piece will be exposed to<br />
a different tempera ture fluctuation, but<br />
the silly thing is that this fluctuation<br />
is not known. A standard<br />
thermostat can be a good<br />
calibrating bath if the volume<br />
is large the preconditioning<br />
time of the test piece is great,<br />
and if the temperature gradient<br />
can be incorpo rated in the<br />
testing tole rance.<br />
For <strong>high</strong>er demands, aluminium<br />
car tridges „modelled on<br />
a Swiss cheese“ can be used,<br />
but the better solution for this<br />
is the calibration insert:<br />
Function principle<br />
The thermostat medium at constancy<br />
flows through the heat exchanger (A)<br />
and via the distributor (B) down into the<br />
calibrating bath. Temperature fluctuations<br />
in the thermostat are evened out<br />
in (A) by overlap. The entire system acts<br />
as a calorimeter. There are virtually no<br />
gradients and no delay in the case of<br />
swift ramps. Temperature stability can<br />
be improved by a factor of 5 to 10. The<br />
cali bration baths CAL1 - CAL4 (page 33)<br />
and the UNICAL (page 34) work with the<br />
same principle.<br />
Displacement inserts<br />
Simple options to boost performance<br />
Volume reduction inserts:<br />
– reduce the li quid volume. Reducing the<br />
bath volume reduces the thermal load<br />
and leads to faster ramping times.<br />
– reduce the li quid’s exposed surface area,<br />
which re duces moisture absorption.<br />
– contain the expansion volume HTF and<br />
prevent the bath from overflowing.<br />
Displacement insert Cat.No. G Price<br />
ministat 125 6818 2<br />
ministat 230 6819 2<br />
ministat 240 6820 2<br />
CC410wl vpc 6293 2<br />
CC505wl vpc - CC520w vpc,<br />
CC810 vpc 6049 2<br />
CC515 vpc, CC905 vpc 6050 2<br />
CC308B vpc 6324 1<br />
CC315B vpc 6043 1<br />
www.huber-online.com · Tel. +49-781-96030<br />
23
HUBER SOFTWARE<br />
SpyLight<br />
SpyLight is software for the visualisation<br />
and documentation of process relevant<br />
data. The communication can be via the<br />
RS 232, RS485 or TCP/IP. The installa-tion<br />
is simple. SpyLight requires very little<br />
disk space and is simple to use. The<br />
logged data is displayed against time.<br />
The axes can be scaled as required. The<br />
zoom function allows easy evaluation of<br />
short time frames.<br />
SpyWatch<br />
SpyWatch is based on the SpyLight software<br />
but offers more features. Installation<br />
and operation is identical. SpyWatch<br />
can operate up to 10 channels simulta-<br />
neously. Each channel is independently<br />
documented and the graphic options can<br />
be configured as required. SpyWatch allows<br />
the user to issue the following instructions<br />
to the unit:<br />
– Set point<br />
– Change from jacket to process<br />
temperature<br />
– Start/Stop<br />
Spy-Funktion<br />
for immediate Service<br />
The spy function integrated in both programs<br />
enables simultaneous recording<br />
of machine parameters allowing a simple<br />
diagnosis in the event of a problem.<br />
The data to be displayed can be selected<br />
by the user. Text can be added to every<br />
curve.<br />
Once the curve has been generated<br />
speed support is available. As soon as<br />
our technicians or our service partners<br />
receive your email with the data logging<br />
the situation can be analysed, to establish<br />
if it is a unit or application problem.<br />
Renowned in its worldwide use.<br />
24 www.huber-online.com · Tel. +49-781-96030<br />
Test run with a 20 litre reactor filled with DW Therm<br />
Test run with a 300 watt in a 20 litre reactor filled with DW Therm<br />
Huber Software Cat.No. G Price<br />
SpyLight (1 Channel) 6790 1<br />
SpyWatch (10 Channel) 6791 1<br />
SpyControl (10 Channel) 6792 1<br />
ComBox (NAMUR) Ministate, CC internal 6779 1<br />
ComBox (NAMUR) CC400, CC401 (ext. box) 6789 1<br />
Control cable CC/PC 6198 1<br />
CP RS232/PC RS232 6146 1<br />
Y cable unistat/PC + analogue 6326 1
UNISTATS<br />
Scale-Up<br />
The Unistats cover a temperature of<br />
-120°C to 400°C. They range in cooling<br />
powers from 0,7 to 130 kW and heating<br />
powers from 1,5 kW to 80 kW. A low internal<br />
volume means that this energy is<br />
transmitted to the process (watts/litre<br />
DIN12876). Uniformity in technology<br />
and control throughout the range gives<br />
each scale of application familiarity<br />
unique to the Unistats. They are the system<br />
of choice for kilo labs, process research,<br />
mini-plants and production.
UNISTATS Plug & Play<br />
Why the name „Tango<br />
Technology“?<br />
To perform the Tango dance requires<br />
skilled partners to glide in rhythm and<br />
unity from a tightly held and controlled<br />
posture to another in a rapid and effortless<br />
movement.<br />
The name “Tango” was adopted to reflect<br />
the way in which the Unistats control<br />
the temperature of a process…<br />
…swift change, tight control, minimum<br />
effort.<br />
Safety First<br />
All the Unistats are fitted with an independent<br />
over-temperature protection<br />
device and a circulating fluid monitoring<br />
device. When these devices are activated<br />
the Unistats give a visual and audible<br />
warning and shut down to stand-by<br />
mode.<br />
Unistats are manufactured, tested and<br />
classified to the requirements dictated<br />
by the strict DIN 12876.<br />
High Temperature Cooling<br />
HT cooling means that active cooling<br />
for the process at temperatures up to<br />
400°C is available. This is possible only<br />
because of another unique Unistat feature,<br />
“HT cooling”. “HT” cooling and<br />
mechanical refrigeration work together<br />
to provide the widest working temperature<br />
range in a single unit. The extreme<br />
of this is the “Unistat 420wHT” with a<br />
temperature range that spans 420°K<br />
from -120…300°C.<br />
Differentiating Benefits<br />
Tight thermal control of chemical<br />
reactions<br />
Rapid response to changing thermal<br />
dynamics<br />
No moisture absorption into the<br />
thermal fluid at low temperatures<br />
No oil cracking, oxidisation or discolouring<br />
of thermal fluid<br />
No oil vapours at <strong>high</strong> temperatures<br />
A single fluid to perform <strong>high</strong> and<br />
low temperature chemistry.<br />
(DW-Therm has a temperature<br />
range of -90…200°C when used with<br />
a Unistat)<br />
Extremely low running costs<br />
Extends working temperature range<br />
of thermal fluids<br />
26 www.huber-online.com · Tel. +49-781-96030<br />
Controller Cat.No. G Price<br />
Unistat Control Panel 6139 2<br />
Unistat Control 6107 2
Facts UNISTATS<br />
Unistats … the Concept<br />
… passive components<br />
and the laws of physics…<br />
The Unistat range was first introduced<br />
over 14-years ago. It was and remains<br />
unique in the level of control it gives<br />
to the user and the way in which such<br />
massive cooling and heating powers are<br />
not just generated, but also transferred<br />
to your process.<br />
The Unistat range is designed to give the<br />
operator extremely tight control over the<br />
temperature of a process regardless of<br />
the varying thermal loads generated by<br />
chemical reactions.<br />
The low internal volume ensures that the<br />
cooling and heating power generated by<br />
the machine controls the temperature of<br />
the process … not a large reservoir of<br />
fluid. (Watts/Litre DIN 12876). This allows<br />
rapid changes in temperature and<br />
tight control over the flow of thermal<br />
energy.<br />
The hydraulically sealed fluid system<br />
means no oil vapours or oil cracking at<br />
<strong>high</strong> temperatures and no moisture absorption<br />
at low temperatures. You can<br />
expect far longer life times and extended<br />
temperature ranges from your expensive<br />
thermal fluid with a Unistat.<br />
However, the true engineering triumph<br />
is in the simplicity of the design. In a<br />
standard Unistat … from the smallest<br />
to the largest … there is only one electro-mechanical<br />
valve. The rest is simply<br />
physics and the laws of physics do not<br />
break.<br />
Standard Features<br />
Hydraulically sealed thermal fluid<br />
system<br />
Low internal volume<br />
Process control via external Pt100<br />
Ramp function<br />
Internal programmer<br />
Comprehensive fault diagnostics<br />
Continual self-test<br />
RS232, RS485 and analogue interface<br />
Potential free and programmable<br />
NO/NC contacts (Potential free contacts)<br />
Multifunctional programmable<br />
alarms<br />
Robust stainless steel construction<br />
www.huber-online.com · Tel. +49-781-96030<br />
27
UNISTATS Tango Principle<br />
Tango Technology<br />
and the Unistats<br />
Peter Huber realized the concept of a hydraulically<br />
sealed, low volume thermostat<br />
over 15 years ago. The development of the<br />
first systems (and continuing improvements)<br />
was in partnership with close contacts in the<br />
pharmaceutical industry. Following a period<br />
of Beta testing, “Tango Technology” became<br />
commercially available in the “Unistat” range<br />
of products in 1990.<br />
Tango Technology has been refined and the<br />
Unistats have grown to dominate their field in<br />
a variety of applications.<br />
The latest generation of Unistats have increased<br />
the performance by such large margins<br />
with such massive leaps forward in functionality<br />
and control that we had to re-name them.<br />
The “Nuevo” Unistats bring even faster response,<br />
even tighter control and even greater<br />
efficiencies.<br />
For “internal” applications such as test tubes<br />
or flasks that need to be partially or fully<br />
submersed in the reservoir, an “open-bath”<br />
thermostat is ideal.<br />
Open bath thermostats connected to “external”<br />
applications are clumsy and slow<br />
resulting in poor temperature control of the<br />
application. The large fluid volume and poor<br />
thermal transfer of the heat exchanger coils<br />
immersed in it add up to slow ramping times<br />
and lethargic response to changing thermal<br />
loads such as when a heat generating reaction<br />
takes place.<br />
Open-bath thermostats carry operational disadvantages<br />
that have a direct impact on the<br />
process and more importantly, profits.<br />
The main disadvantages are:<br />
1. The reservoir:<br />
The reservoir serves two functions.<br />
– To contain the thermal fluid<br />
– To allow for the expansion of the thermal<br />
fluid as it heats and cools<br />
The larger the external application the greater<br />
the “tidal flow” as the fluid expands and<br />
contracts and so the bath has to be larger to<br />
contain it.<br />
The total thermal load that the cooling and<br />
heating system must “drive” is made up<br />
(mainly) of the total volume of thermal fluid<br />
+ the process. The larger the bath the less<br />
of the generated power will be spent on the<br />
application.<br />
This phenomenon is expressed in “watts per<br />
litre” (w/l). A simple example that demonstrates<br />
this is a kettle. A two litre kettle with a 1<br />
kW heater will have a w/l ratio of 500 w/l and<br />
will take “time x” to boil. The same kettle with<br />
only 1 litre of water will have a ratio of 1000w/l<br />
and will boil in half the time.<br />
Since the control of a reaction depends on the<br />
speed with which the jacket of the reactor can<br />
be adjusted to initiate and maintain the flow<br />
of thermal energy, a large volume of thermal<br />
fluid acts as effective thermal “slug” which<br />
adversely effects response times.<br />
2. The heat exchange surfaces<br />
Thermal transfer depends greatly on surface<br />
area. This phenomenon is expressed as a ratio<br />
of “watts per square centimetre” (w/cm²). The<br />
28 www.huber-online.com · Tel. +49-781-96030<br />
smaller the surface area the greater this ratio<br />
becomes and the poorer the thermal transfer<br />
becomes. Heat exchangers in the form of coils<br />
have a comparatively small surface area and<br />
so are poor at transferring thermal energy<br />
effectively.<br />
Imagine a sports stadium that holds 50,000<br />
people and it has only one door. Now imagine<br />
if the stadium had open sides. 50,000 people<br />
will be able to transfer are lot quicker through<br />
a larger surface area.<br />
3. Moisture absorption<br />
Water condenses on cold surfaces. At the bath<br />
opening it is seen as condensation but in the<br />
reservoir it condenses on the cold surface and<br />
collects on the evaporator as ice. Since ice is<br />
a good insulator, the growing layer of ice prevents<br />
heat from travelling from the thermal<br />
fluid to the refrigeration system. If the heat<br />
cannot be removed from the thermal fluid, it<br />
cannot be removed from the process.<br />
4. Oil vapours<br />
At elevated temperatures the thermal fluids<br />
give of vapours which condense on laboratory<br />
surfaces. They can also create health and<br />
safety issues and clog HEPA filters. These<br />
vapours also become flammable at temperatures<br />
dependent on the thermal fluids being<br />
used. This limits the operational range of the<br />
thermal fluid.<br />
Tango Technology eliminates all of the above<br />
disadvantages.<br />
The fluid circuit is hydraulically sealed, the expansion<br />
and contraction of the thermal fluid as<br />
it heats and cools is catered for in an “expansion<br />
tank”. This expansion tank is thermally<br />
isolated but mechanically connected to the<br />
circulating fluid system.<br />
This means that no matter what the temperature<br />
is at the process, the fluid in the expansion<br />
tank remains at 2 –3 degrees around room<br />
temperature.<br />
Being hydraulically sealed means that there is<br />
no moisture absorption at low temperatures<br />
and no vapours at <strong>high</strong> temperatures. This has<br />
the effect of widening the operational range of<br />
a thermal fluid. It also means the elimination<br />
of the build up of oily residues in the laboratory.<br />
It is important to note that this is achieved<br />
by using “passive” components and the laws<br />
of physics. Mechanical or electro mechanical<br />
valves have not been employed for safety and<br />
efficiency reasons.<br />
Process control is greatly improved because:<br />
1. There is no “reservoir” in the Unistats. The<br />
volume of the circulating thermal fluid is minimal<br />
(2-4 litres in most Unistats) and so most<br />
of the generated heating and cooling power<br />
is spent at the application.<br />
This is expressed in watts per litre and the<br />
Unistats have the <strong>high</strong>est ratios.<br />
This results in extremely fast ramp times. The<br />
temperature of the jacket can be rapidly adjusted<br />
to initiate and maintain the flow of thermal<br />
energy enabling tight control over the most<br />
dynamic of reactions.<br />
2. Plate heat exchangers are used to transfer<br />
thermal energy much more efficiently. The<br />
characteristic of a plate heat exchanger is to<br />
present a very large surface area within a very<br />
low volume (the sports stadium with no sides<br />
as explained above!)<br />
This is expressed in “watts per square centimetre”<br />
(w/cm²). Because this ratio is so low<br />
Unistats capable of not just generating massive<br />
thermal powers but also of transferring<br />
thermal energy rapidly without damaging the<br />
thermal fluid.<br />
The net effect is a smaller, more compact and<br />
process directed thermostat. Results can be<br />
measured in increased yields, faster process<br />
times and duplication of results.
High Temperature<br />
Thermostats<br />
High-<strong>precision</strong> and space-saving temperature<br />
control up to +400°C. The new<br />
HT thermostats of the Unistat cc400<br />
range set new standards in safety, easy<br />
operation, and rapid, dynamic temperature<br />
control. The Unistat cc401w HT<br />
model features integral stepper motor<br />
to control the HT-Cooling, level protection<br />
and configurable overtemperature<br />
protection. Its minimal internal volume<br />
allows the shortest heat-up times to be<br />
achieved, while at the same time the<br />
maximum expansion tank temperature<br />
is limited to +60°C. The working life and<br />
properties of the thermal fluid are also<br />
protected, by avoiding direct contact<br />
between the hot fluid and atmosphere.<br />
The HT thermostats with controlled HT-<br />
Cooling are suitable for temperature<br />
control applications up to +400°C, e.g.<br />
a double-jacketed reaction vessel (reactor),<br />
and pilot plants, as well as the<br />
semiconductor Industry and <strong>high</strong> temperature<br />
distillation. They are suitable to<br />
maintain a <strong>high</strong> constant temperature,<br />
or to contain an exothermic reaction at<br />
<strong>high</strong> temperature.<br />
Unistats to 400°C<br />
Accessories see page 36, 45..<br />
Models UNISTATS<br />
Model Temperature Range Pump max. Heating Cooling Power [kW] at [°C] Dimensions Cat.No. G Price<br />
[°C] [l/min] [bar] [kW] 400 300 200 100 W x D x H [mm]<br />
unistat cc400-3 75..400 12 0,5 3,0 190x240x635 400.0003 3<br />
unistat cc401-3 50..400 23 0,5 3,0/9,0 285x330x735 400.0023 3<br />
unistat cc401w HT-3 (15) 50..400 23 0,5 3,0/9,0 10,0 10,0 10,0 10,0 285x330x735 400.0033 3<br />
Unistate to 300°C<br />
Model Temperature Range Pump max. Heating Cooling Power [kW] at [°C] Dimensions Cat.No. G Price<br />
[°C] [l/min] [bar] [kW] 400 300 200 100 W x D x H [mm]<br />
unistat T326 (15) 65..300 15 0,5 3,0/6,0 425x220x635 532.0002 3<br />
unistat T326 HT 65..300* 15 0,5 3,0/6,0 3,2 2,3 0,6 425x220x635 531.0002 3<br />
unistat T326w HT (15) 65..300 15 0,5 3,0/6,0 10,0 10,0 6,0 425x220x635 530.0002 3<br />
unistat T327 (15) 65..300 70 1,6 12,0 460x550x1336 525.0002 3<br />
unistat T327w HT (15) 65..300 60 1,6 12,0 10,0 10,0 6,0 460x550x1336 526.0002 3<br />
* The lowest temperature is 15 K above room temperature<br />
Advantages of High Temperature<br />
Thermostats:<br />
Small space required<br />
Low fill-volume<br />
High Pump capacity<br />
Rapid filling of the complete<br />
application efficient with venting<br />
+60°C max. expansion tank temperature<br />
Plug & Play Technology<br />
Simple operation<br />
High level of safety through constant<br />
monitoring<br />
unistat cc400<br />
unistat cc401w HT-3<br />
www.huber-online.com · Tel. +49-781-96030<br />
Plug & Play<br />
3 Years<br />
Warranty<br />
29
UNISTATS Models<br />
It takes two to tango!<br />
Thermo dyna mics and Microelectronics.<br />
Hydrau li-cally sealed, no fumes, no oil<br />
cracking, no moi sture absorption, sea led<br />
expansion vessel for open baths. Tango<br />
and Unistat 360 can be located under the<br />
lab bench and the control panel (Plug &<br />
Play) can be located in the work place<br />
via the adapter cable. These units incorporate<br />
the full range of the vapour<br />
compression technology: sin gle and<br />
multiple stage compression, cas cade, air<br />
and water-cooling. Tem pe ra tu re stability<br />
better than 0,05 K to DIN 12876. Ide al for<br />
scale-up from lab to pro duction. Tan go<br />
and the big-power Unistats are the leading<br />
technology of thermo stats. Please<br />
ask the Tan go Club.<br />
High Technology „CoolNet“<br />
All Unistat refrigeration machines use the<br />
stepper motor control expansion valve<br />
„CoolNet“, manufactured by Huber. This<br />
ensures that optimal performance from the<br />
evaporator is achieved, and the maximum<br />
possible power is obtained. Without the<br />
CoolNet the Unistats could not achieve such<br />
dynamic, performance, control stability and<br />
operational safety.<br />
New! Ex Zone Solutions<br />
There are two solutions for Ex Zone<br />
<strong>thermoregulation</strong> applications. The first<br />
is to work with a standard unit located<br />
in a safe area and an Ex Rated remote<br />
control panel located in the hazardous<br />
zone. The second solution is to locate<br />
a fully Ex Rated unit (pressure encapsulation,<br />
see table below) within the<br />
hazardous zone. Further information is<br />
available on request.<br />
425 425 mm mm<br />
Plug & Play<br />
3 Years<br />
Warranty<br />
New!<br />
Ex Zone<br />
Solutions<br />
Model Cat.No. G Price<br />
EEx p Housing I (for Unistats T327w, 140w, 141w, 150w, 151w, 380w, 385w, 386w, 390w, 420w, 160w, 161w, 162w, 163w) 6967 –<br />
EEx p Housing II (for Unistats 164w, 165w, 290w, 291w and UC160Tw-4) 6968 –<br />
EEx p Housing III (for Unistats 167w, 169w) 6969 –<br />
EEx p Housing IV (for Unistats T326w HT, tango, 340w, 360w) 6970 –<br />
Remote Control Unistat EXi - EEx ib IIC T4 6702 –<br />
EXi Temperature Measurement (Pt100 converter) 6703 –<br />
30 www.huber-online.com · Tel. +49-781-96030<br />
636 636 mm<br />
270 270 mm mm<br />
Accessories see page 36, 45..
Unistats to -55°C<br />
Unistats to -60°C<br />
Unistat Minus<br />
The „Unistat Minus“ models had been specially developed for work at<br />
low temperatures. These low cost alternatives have powerful refrigeration<br />
and „Tango“ technology with the user friendly controller CC3.<br />
They are available either in flat design (FB) or in a tower casing. Typical<br />
applications are pour point apparatus, low temperature calorimetry,<br />
combination chemistry or crystallisations.<br />
Accessories see page 36, 45..<br />
Models UNISTATS<br />
New!<br />
Ex Zone<br />
Solutions<br />
Model Working Temperature Pump max. Heating Cooling Power [kW] at [°C] Dimensions Cat.No. G Price<br />
Range [°C] [l/min] [bar] [kW] 300 200 100 0 -20 -40 W x D x H [mm]<br />
unistat tango -40..200 15 0,5 1,5/3,0 0,7 0,7 0,7 0,4 0,05 425x270x636 534.0003 3<br />
unistat tango HT -40..300 15 0,5 1,5/3.0 3,2 2,3 1,3 0,7 0,4 0,05 425x270x636 533.0003 3<br />
unistat 340 -40..200 20 0,7 1,5/3.0 1,0 1,0 1,0 0,6 0,1 425x300x636 710.0004 3<br />
unistat 340w -40..200 20 0,7 1,5/3.0 1,0 1,0 1,0 0,6 0,1 425x270x636 710.0003 3<br />
unistat 340 HT -40..300 15 0,5 1,5/3.0 3,2 2,3 1,8 1,0 0,6 0,1 425x300x636 711.0003 3<br />
unistat 340w HT -40..300 15 0,5 1,5/3.0 3,5 2,3 1,8 1,0 0,6 0,1 425x300x636 711.0004 3<br />
unistat 140 -40..200 100 1,5 2,0 2,0 2,0 2,5 1,8 0,2 460x550x1336 544.0004 3<br />
unistat 140w -40..200 100 1,5 2,0 2,0 2,0 2,5 1,8 0,2 460x550x1336 545.0004 3<br />
unistat 140w-FB -40..200 100 1,5 2,0 2,0 2,0 2,5 1,8 0,2 920x635x740 545.0004FB 3<br />
unistat 140 HT -40..300 60 1,6 2,0 3,2 2,3 2,7 2,5 1,8 0,2 460x550x1336 712.0001 3<br />
unistat 140w HT -40..300 60 1,6 2,0 3,5 3,0 2,7 2,5 1,8 0,2 460x550x1336 712.0002 3<br />
unistat 141 -40..200 90 1,5 4,0 3,5 3,5 3,5 2,2 0,3 460x550x1336 550.0005 3<br />
unistat 141w -40..200 90 1,5 4,0 3,5 3,5 3,5 2,2 0,2 460x550x1336 551.0005 3<br />
unistat 141w-FB -40..200 70 1,6 4,0 3,0 3,5 3,5 2,2 0,2 920x635x740 551.0005FB 3<br />
unistat 141 HT -40..300 60 1,6 4,0 3,2 4,0 3,5 3,5 2,2 0,3 460x550x1336 713.0003 3<br />
unistat 141w HT -40..300 60 1,6 4,0 3,5 4,0 3,5 3,5 2,2 0,2 460x550x1336 713.0004 3<br />
unistat 150w -50..200 100 1,5 6,0 5,0 5,0 5,0 2,8 0,9 460x550x1336 715.0001 3<br />
unistat 150w HT -50..300 80 1,5 6,0 3,5 6,0 5,5 5,0 2,8 0,9 460x550x1336 716.0001 3<br />
unistat 151w -55..200 60 1,5 6,0 5,0 5,0 6,0 4,2 1,5 540x600x1336 717.0001 3<br />
unistat 151w-FB -55..200 60 1,5 6,0 5,0 5,0 6,0 4,2 1,5 920x635x740 717.0001FB 3<br />
Model Working Temperature Pump max. Heating Cooling Power [kW] at [°C] Dimensions Cat.No. G Price<br />
Range [°C] [l/min] [bar] [kW] 200 100 0 -20 -40 -60 W x D x H [mm]<br />
unistat 160w -60..200 50 1,5 6,0 7,0 7,0 7,0 6,0 3,3 0,8 600x700x1515 552.0005 4<br />
unistat 161w -60..200 50 1,5 12,0 9,0 9,0 9,0 7,0 4,8 1,0 600x700x1515 556.0005 4<br />
unistat 162w -60..200 90 2,5 12,0 12,0 12,0 12,0 12,0 7,0 2,0 700x800x1515 557.0005 4<br />
unistat 163w -60..200 90 2,5 12,0 16,0 16,0 16,0 13,5 8,4 2,2 700x800x1515 559.0004 4<br />
unistat 164w -60..200 110 2,5 24,0 22,0 22,0 20,0 18,0 15,0 5,0 920x1000x1655 719.0001 5<br />
unistat 165w -60..200 110 2,5 24,0 26,0 26,0 25,0 24,0 18,0 6,0 920x1000x1655 720.0001 5<br />
unistat 166w -60..200 100 2,5 30,0 30,0 30,0 30,0 30,0 20,0 6,0 920x1200x1655 723.0001 5<br />
unistat 167w -60..200 100 2,5 36,0 40,0 40,0 40,0 40,0 22,0 7,0 1800x1200x1830 724.0001 5<br />
unistat 169w -60..200 100 2,5 48,0 65,0 65,0 65,0 65,0 38,0 11,0 1800x1200x1830 726.0001 5<br />
unistat 1060w -60..200 100 2,5 96,0 130,0 130,0 130,0 80,0 60,0 20,0 4500x2000x2000 733.0001 5<br />
unistat minus 55w-FB-3<br />
Model Working Temperature Pump max. Heating Cooling Power [kW] at [°C] Dimensions Cat.No. G Price<br />
Range [°C] [l/min] [bar] [kW] 0 -20 -40 -60 -80 W x D x H [mm]<br />
unistat minus 55w-FB-3 -55..50 55 1,6 2,0 6,0 4,2 1,5 920x635x740 717.0106 4<br />
unistat minus 85w-FB-3 -85..50 18 0,7 2,0 2,3 2,3 2,0 1,2 0,2 1200x650x745 549.0105 4<br />
unistat minus 90w-3 -90..50 40 1,5 4,0 5,2 5,0 4,2 2,9 0,75 600x700x1550 554.0112 4<br />
unistat minus 90w-FB-3 -90..50 40 1,5 4,0 5,2 5,0 4,2 2,9 0,75 1500x700x900 554.0109 4<br />
Option:<br />
Natural<br />
Refrigerants<br />
(Page 50...)<br />
www.huber-online.com · Tel. +49-781-96030<br />
31
UNISTATS Models<br />
Option:<br />
Natural<br />
Refrigerants<br />
(Page 50...)<br />
unistat 360<br />
Unistats to -85°C<br />
Unistats to -90°C<br />
unistat 385<br />
Model variations<br />
w: water-cooled refrigeration<br />
HT: with <strong>high</strong> temperature cooler<br />
FB: flat built version<br />
unistat 385w-FB<br />
Model Working Tempera- Pump max. Heating Cooling Power [kW] at [°C] Dimensions Cat.No. G Price<br />
ture Range [°C] [l/min] [bar] [kW] 300 200 100 0 -20 -40 -60 -80 W x D x H [mm]<br />
unistat 360 -75..200 25 0,8 1,5/3,0 0,6 0,6 0,6 0,6 0,3 425x400x720 536.0006 3<br />
unistat 360w -75..200 25 0,8 1,5/3,0 0,6 0,6 0,6 0,6 0,3 425x400x720 536.0005 3<br />
unistat 360 HT -75..300 16 0,8 1,5/3,0 3,2 2,3 1,4 0,6 0,6 0,6 0,3 425x400x720 535.0006 3<br />
unistat 360w HT -75..300 16 0,8 1,5/3,0 3,5 2,3 1,4 0,6 0,6 0,6 0,3 425x400x720 535.0005 3<br />
unistat 380 -80..200 35 0,8 2,0 1,3 1,3 1,3 1,3 0,9 0,2 460x600x1346 539.0006 3<br />
unistat 380w -80..200 35 0,8 2,0 1,5 1,5 1,5 1,5 0,9 0,2 460x600x1346 540.0006 3<br />
unistat 380 HT -80..300 30 0,8 2,0 3,2 2,3 1,8 1,3 1,3 1,3 0,9 0,2 460x600x1346 537.0006 3<br />
unistat 380w HT -80..300 30 0,8 2,0 3,5 2,3 1,8 1,5 1,5 1,5 0,9 0,2 460x600x1346 538.0006 3<br />
unistat 380w HT-FB -80..300 30 0,8 2,0 3,5 2,3 1,8 1,5 1,5 1,5 0,9 0,2 1200x650x740 538.0006FB 3<br />
unistat 385 -85..200 30 0,8 3,0 2,3 2,3 2,3 2,0 1,2 0,3 460x600x1346 548.0006 4<br />
unistat 385w -85..200 30 0,8 3,0 2,3 2,3 2,3 2,0 1,2 0,3 460x600x1346 549.0006 4<br />
unistat 385w-FB -85..200 30 0,8 3,0 2,3 2,3 2,3 2,0 1,2 0,3 1200x650x740 549.0005FB 4<br />
unistat 385 HT -85..300 30 0,8 3,0 3,2 2,3 2,7 2,3 2,3 2,0 1,2 0,3 460x600x1346 546.0006 4<br />
unistat 385w HT -85..300 30 0,8 3,0 3,5 2,3 2,7 2,3 2,3 2,0 1,2 0,3 460x600x1346 547.0006 4<br />
unistat 386 -85..200 32 0,8 3,0 4,0 3,8 3,5 3,5 3,0 2,0 0,6 540x650x1490 721.0002 4<br />
unistat 386w -85..200 32 0,8 3,0 4,0 3,8 3,5 3,5 3,0 2,0 0,6 540x650x1490 722.0002 4<br />
Model Working Tempera- Pump max. Heating Cooling Power [kW] at [°C] Dimensions Cat.No. G Price<br />
ture Range [°C] [l/min] [bar] [kW] 300 200 100 0 -20 -40 -60 -80 W x D x H [mm]<br />
unistat 390w -90..200 40 1,5 6,0 5,2 5,2 5,0 4,2 3,1 0,9 600x700x1560 554.0005 4<br />
unistat 390w HT -90..300 35 1,5 6,0 4,5 2,6 7,0 5,2 5,0 4,2 3,1 0,9 600x700x1560 553.0005 4<br />
unistat 290w -90..200 57 1,3 12,0 16,0 16,0 16,0 16,0 15,0 13,5 3,5 920x1200x1655 558.0003 4<br />
unistat 291w -90..200 80 2,5 24,0 19,0 19,0 19,0 19,0 17,0 15,0 6,0 920x1200x1655 705.0001 5<br />
unistat 292 -90..200 100 2,5 36,0 36,0 30,0 30,0 30,0 28,0 24,0 10,0 1700x3500x1850 706.0001 5<br />
unistat 292w -90..200 100 2,5 36,0 36,0 30,0 30,0 30,0 28,0 24,0 10,0 2400x1200x1750 706.0002 5<br />
32 www.huber-online.com · Tel. +49-781-96030<br />
New!<br />
Ex Zone<br />
Solutions<br />
Accessories see page 36, 45..
Unistats to -120°C<br />
Calibration Baths<br />
Models UNISTATS<br />
unistat 390w<br />
unistat 291w<br />
Model Working Tempera- Pump max. Heating Cooling Power [kW] at [°C] Dimensions Cat.No. G Price<br />
ture Range [°C] [l/min] [bar] [kW] 300 200 100 0 -20 -60 -80 -100 W x D x H [mm]<br />
unistat 420w -120..100 18 0,7 2,0 1,5 1,5 1,5 1,4 1,3 1,0 700x800x1515 543.0004 4<br />
unistat 420w HT -120..300 16 0,7 2,0 3,5 3,2 3,0 1,5 1,5 1,4 1,3 1,0 700x800x1515 541.0004 4<br />
unistat 421w -120..100 44 1,5 4,0 2,5 2,5 2,5 2,5 2,0 2,0 920x1200x1655 707.0001 5<br />
This range of calibration baths are designed<br />
for physically small devices.<br />
– Stability better than 0,02 K<br />
to DIN 12876<br />
– Temperature range: -80…250°C<br />
– Bath depth 400 mm<br />
Model Working Temperature Bath Bath Heating Power Cooling Power [kW] Dimensions Cat.No. G Price<br />
Range Volume [kW] at 0°C W x D x H<br />
[°C] [mm] [ltr] [mm]<br />
CAL1 -20..150 Ø120 x 400 7 1,0 0,3 585x425x550 665.0004 3<br />
CAL2 -40..200 Ø120 x 400 7 1,5 0,5 585x425x550 665.0005 3<br />
CAL3 -80..150 Ø120 x 400 7 1,5 0,3 585x560x550 665.0003 3<br />
CAL4 +25..250 Ø120 x 400 7 1,5 – 585x355x550 665.0006 3<br />
All measurements valid for an ambient temperature of +20°C<br />
Accessories see page 36, 45..<br />
New!<br />
Ex Zone<br />
Solutions<br />
www.huber-online.com · Tel. +49-781-96030<br />
Option:<br />
Natural<br />
Refrigerants<br />
(Page 50...)<br />
33
UNISTATS Specials<br />
UNICAL<br />
Calibration systems<br />
The “Unicals” are range of calibration<br />
baths that are designed to be powered<br />
by the Unistat range.<br />
In this way it is possible to manufacture<br />
very large calibration baths capable of<br />
carrying out calibrations from very low<br />
temperatures to very <strong>high</strong> temperatures.<br />
– Stability better than 0,02 K<br />
to DIN 12876<br />
– Temperature range: -80…250°C<br />
– Very large bath volumes available<br />
for batch calibrations<br />
– Can be customised to suit application<br />
The range of calibration baths grows<br />
continually: Large, round (overflow in<br />
the middle) open baths or rectangular<br />
form com bi ned with quick and precise<br />
Uni stats. Temperature Range: -100 to<br />
300°C.<br />
Model Volume Bath Opening Volts at Dimensions Cat.No. G Price<br />
[ltr] [mm] 50 Hz W x D x H [mm]<br />
UniCAL 1 7 Ø115 x 400 230V 708x365x550 655.0001 3<br />
UniCAL 2 32 Ø500 x 215 230V Ø700x490 655.0002 3<br />
UniCAL 3 23 298 x 395 x 200 230V 520x620x505 655.0003 3<br />
Custom models available<br />
Cover Temperature Range Dimensions Cat.No. G Price Holes Price<br />
Material [°C] D x H [mm] [mm]<br />
Edelstahl -100...+300 Ø 220 x 65 6367 1 Ø4-Ø10<br />
Teflon -100...+200 Ø 220 x 30 6365 1 Ø4-Ø10<br />
Polyethylen -100...+100 Ø 220 x 30 6366 1 Ø4-Ø10<br />
Custom models available<br />
34 www.huber-online.com · Tel. +49-781-96030<br />
Custom Model:<br />
UniCAL 8 with Unistat 161w<br />
Insulated Stainless Steel Cover<br />
Accessories see page 36, 45..
The New Dimension<br />
Touchscreen TFT-Display<br />
Simple to operate<br />
Variable Pressure Control VPC<br />
Non-linear programmable ramping<br />
True Adaptive Control (TAC)<br />
Bench top models -75 ... +250°C<br />
Plug & Play Technology<br />
Natural Refrigerants (Option)<br />
Models and further information available at www.huber-online.com<br />
The proven Unistat Technology (Page 28): The<br />
Unistat Tango Nuevo is a hydraulically sealed<br />
circulator with a fully self contained expansion<br />
tank at atmospheric pressure. This means that<br />
the thermostat is atmospherically sealed and<br />
can be located below or above the level of the<br />
application without the risk of siphoning or<br />
back-flow even during power-down or when in<br />
stand-by status.<br />
UNISTAT NUEVO<br />
Effect (Selectable of True system Adaptive response) Control<br />
Rapid ramping (no overshoot)<br />
The new dimension: Air-cooled or air AND water-cooled<br />
refrigeration system (introduced by<br />
Huber in 1997) with an environmental option<br />
using natural refrigerants. Active mechanical<br />
cooling from -45 up to +250°C. Stronger pump<br />
with soft start to eliminate pressure surges is<br />
fitted. The flow pressure is monitored and fully<br />
controlled by VPC technology. The Unistat Pilot<br />
features a colour TFT display with touch-screen.<br />
Temperature<br />
True Adaptive Control<br />
Setpoint<br />
with TAC<br />
without TAC<br />
Faster ramping (minimal overshoot)<br />
Time Time<br />
Temperature<br />
Setpoint<br />
with TAC<br />
without TAC<br />
Easy to operate, it features an internal programmer,<br />
process control capability and an organically<br />
adaptive, self tuning PID controller. The<br />
advanced controller learns and adapts to changing<br />
application demands … constantly. Accessories<br />
include: PC software for documentation<br />
of process relevant data, diagnostics and PCbased<br />
control: SpyLight, SpyWatch, SpyControl.<br />
www.huber-online.com · Tel. +49-781-96030<br />
35
UNISTATS Accessories<br />
Connections for Mettler<br />
Toledo ‚LabMax‘ and ‚RC1‘<br />
For use with the LabMax or the RC1 in<br />
variations High temp, Mid temp and low<br />
temp, use the adapters listed here.<br />
External Pt100 sensors Sensors (standard cable length 1,5 m) Cat.No. G Price<br />
For external <strong>thermoregulation</strong> appli cations<br />
there are dif fe rent sensors available.<br />
Special ver sions can be made on<br />
request.<br />
Control Cables<br />
Control cable for use with RS232, RS485<br />
or analogue interface (AIF). Control cables<br />
can be configured to request.<br />
Pressure booster pump<br />
Pressure pump of stainless steel for temperatures<br />
from -120 to 300°C. To compensate<br />
for the pressure loss in external systems.<br />
The Uni pump is connected in series<br />
with the pump of the unistat and can be<br />
controlled via the volt free contacts of the<br />
unistat con trol.<br />
Adaptor Quantity Cat.No. G Price<br />
unistat 14x Metal Hose NW20/ M30x1,5:<br />
M30x1,5 AG - 1/2“ female 2x 6394 1<br />
M30x1,5 AG - 3/4“ female 2x 6442 1<br />
M30x1,5 AG - M16x1 female 2x 6431 1<br />
Ø 6 mm 180 mm 6138 1<br />
with handle Ø 6 mm 200 mm 6105 1<br />
Ø 8 mm 400 mm 6064 1<br />
mounted in protective pipe Ø 8 mm 170 mm 6205 1<br />
M16x1 sensor for flow or return 6352 1<br />
M16x1 sensor for flow or return double 6353 1<br />
M30x1,5 sensor for flow or return 6509 1<br />
M30x1,5 sensor for flow or return double 6363 1<br />
Extension cable Pt100, 3m 6292 1<br />
Unipump Pump max. Dimensions Cat.No. G Price<br />
[l/min] [bar] W x D x H [mm]<br />
Unipump I M16x1 23 0,5 170x380x175 527.0001 2<br />
Unipump I 2 stage M16x1 35 1,5 170x380x175 527.0002 2<br />
Unipump II M30x1,5 70 1,5 205x430x290 527.0003 2<br />
Unipump II 2 stage M30x1,5 70 2,5 205x430x290 527.0004 2<br />
Control cable Unipump / unistat (3m) 6221 1<br />
Bypass Bypass Cat.No. G Price<br />
For systems with <strong>high</strong> pressure loss. The<br />
Bypass is connected between the flow<br />
and return and is manually controlled<br />
(stepless).<br />
Unistat, bench top M16x1 6415 1<br />
Unistat, others (non-bench top) M16x1 6416 1<br />
Unistat M30x1,5 6417 1<br />
Unistat 420w M16x1 6418 1<br />
Safety Devices<br />
Float switch in-sight glass, leak mo ni-<br />
Safety Devices Cat.No. G Price<br />
toring (<strong>high</strong>est safety class).<br />
Float Switch 6152 1<br />
Atmospheric sealing kit for sight glass<br />
and expansion vessel, e.g. for inert gas<br />
blanketing.<br />
Sealing Kit 6523 2<br />
Trolleys<br />
The trolleys make the Unistats mobile.<br />
36 www.huber-online.com · Tel. +49-781-96030<br />
Communication cables Control Panel CP (standard cable length 3 m) Cat.No. G Price<br />
from to Note<br />
CP PC RS232 6146 1<br />
CP Unistat controller Extension cable for control panel 6147 1<br />
CP RS485 Cable end open 6279 1<br />
CP Analog Cable end open 6254 1<br />
CP Remote control CC3 6737 1<br />
Y cable unistat/PC + analogue 6326 1<br />
Model Cat.No. G Price<br />
unistat tango, unistat tango HT, 340w 6280 2<br />
unistat T326 6469 2<br />
unistat 360, 360w, 360 HT, 360w HT 6263 2<br />
unistat 340, 340 HT, 340w HT 6630 2
Controller Cat.No. G Price<br />
CC1 658.0001 1<br />
CC2 658.0002 1<br />
CC3 658.0003 1<br />
Unistat Control Panel 6139 2<br />
Unistat Control 6107 2<br />
Facts UNICHILLERS<br />
Differentiating Features<br />
Simple to use<br />
Robustly reliable and innovative refrigeration<br />
system<br />
Bright LED level display…can easily be read<br />
from long distances<br />
Powerful pumps for demanding applications<br />
Frame and casing manufactured from<br />
stainless steel<br />
Industrial strength resists work-place abuse<br />
Efficient energy management lowers resource<br />
consumption<br />
Tower design consumes less floor space<br />
CC1, CC2 and CC3 controllers for operational<br />
uniformity<br />
Water-cooled and air-cooled versions available<br />
Lifting lugs fitted to aid location
38<br />
UNICHILLER Bench Top<br />
Features<br />
Operation<br />
Simple menu driven control<br />
LCD for good view<br />
LCD for set point/actual temperature,<br />
operating conditions, set<br />
point limits, service information<br />
Dialogue<br />
digital interface RS232, RS485,<br />
analogue interface 4 - 20 mA<br />
(not CC1 and CC2)<br />
Cascade Control<br />
Connection for external<br />
Pt100 sensor (not CC1)<br />
Software<br />
Windows-software for documentation<br />
and visualization. Free Software<br />
updates are guaranteed!<br />
New Minichillers<br />
The minichiller is an incredibly compact<br />
chiller that packs a cooling punch<br />
beyond its size. Compact, robust and<br />
powerful, now in stainless<br />
steel casing. There<br />
are four controller<br />
options, the simplest<br />
option does not offer<br />
the unique advantages<br />
of Plug & Play technology.<br />
The CC1 to CC3<br />
options with the superior<br />
funtionality do have<br />
these benefits. The<br />
cooling performance<br />
is the same irrespective<br />
of the controller.<br />
Unichiller (bench top)<br />
Unichillers are intelligent circulation<br />
coolers in the low-priced, classic desktop<br />
housing.<br />
Typical is the flat construction with a<br />
footprint which orientates itself by the<br />
depth of the desk. The more power ful<br />
models beginning from UC015 fit under<br />
the working bench. All Unichillers work<br />
with the interchangeable CC con trollers.<br />
With the help of a remote kit the controller<br />
can be sepa rated from the Unichiller.<br />
All Uni chillers have an automatic power<br />
adjust ment and can be factory-fitted<br />
with a heating.<br />
UC006A-2<br />
Model Working Temperature Pump max. Cooling Power [kW] at [°C] Dimensions mobile Cat.No. G Price<br />
Range [°C] [l/min] [bar] 15 0 -10 W x D x H [mm] with roller<br />
minichiller -20...40 12 0,2 0,3 0,2 0,14 225x360x380 – 466.0010 2<br />
minichiller w -20...40 12 0,2 0,3 0,2 0,14 225x360x380 – 466.0020 2<br />
minichiller-1* -20...40 12 0,2 0,3 0,2 0,14 225x360x380 – 466.0011 2<br />
minichiller w-1* -20...40 12 0,2 0,3 0,2 0,14 225x360x380 – 466.0021 2<br />
UC006A-1* -20...40 18 0,5 0,6 0,5 0,22 277x500x425 – 576.0031 3<br />
UC007 -20...40 22 3,0 0,7 0,55 0,35 320x500x493 – 576.0050 3<br />
UC007-1* -20...40 22 3,0 0,7 0,55 0,35 320x500x493 – 576.0051 3<br />
UC015-1* -10...40 25 3,0 1,5 1,0 0,4 410x480x540 height: 610 677.0021 3<br />
UC015w-1* -10...40 25 3,0 1,5 1,0 0,4 410x480x540 height: 610 677.0031 3<br />
UC022-1* -10...40 25 3,0 2,2 1,6 1,0 460x510x755 incl. 670.0031 3<br />
UC022w-1* -10...40 25 3,0 2,2 1,6 1,0 460x510x755 incl. 670.0041 3<br />
UC020-1* -10...40 25 3,0 2,0 2,0 1,3 460x510x755 incl. 672.0031 3<br />
UC020w-1* -10...40 25 3,0 2,0 2,0 1,3 460x510x755 incl. 672.0041 3<br />
UC025-1* -10...40 25 3,0 2,5 2,0 1,2 460x615x755 incl. 674.0041 3<br />
UC025w-1* -10...40 25 3,0 2,5 2,0 1,2 460x510x755 incl. 674.0051 3<br />
* 3 controller options Option heating for minichiller-x 1 kW, for UC models 2 kW<br />
www.huber-online.com · Tel. +49-781-96030<br />
Programmer<br />
cc2 up to 5 steps<br />
cc3 50 steps divisible in<br />
10 programs<br />
from 10 kW:<br />
9 programs with 30 steps<br />
Self Diagnostic<br />
Automatically after switch on<br />
Multifunctional Alarm<br />
visual and audio, adjustable alarm<br />
values volt free contact programmable<br />
(not cc1 and cc2)<br />
Calibrateable<br />
Internal and external Pt100 sensor<br />
calibrated through offset correction.<br />
Mains Failure Programmable<br />
Option to switch the thermostat off<br />
in the event of mains failure or auto<br />
restart on reinstatement of electrical<br />
supply.<br />
Fault Diagnosis<br />
Flow-control<br />
Over- and undertemperature control<br />
overheating protection<br />
for units from 10 kW on remote<br />
maintenance via modem<br />
constant memory for the logging<br />
of the unit’s state<br />
Autostart<br />
Date/time and after mains failure<br />
(from 10 kW)<br />
Option:<br />
Accessories see page 43, 45..<br />
UC015-3<br />
Natural<br />
Refrigerants<br />
(Page 50...)
Plug & Play<br />
3 Years<br />
Warranty<br />
Plug & Play UNICHILLERS<br />
New Look:<br />
Unichiller in<br />
Tower Casings<br />
Unichillers.<br />
0,6 kW…100 kW @ 15°C<br />
The smaller Unichillers consume<br />
minimum floor space<br />
with the new tower construction.<br />
High cooling powers are<br />
matched with low volume<br />
(to DIN 12876) in typical<br />
HUBER style so that <strong>high</strong><br />
cooling powers does not<br />
mean sacrificing valuable<br />
laboratory floor space.<br />
New: to save power and reduce<br />
noise, the chillers are<br />
fitted with condensor fans<br />
that vary their speed according<br />
to the load conditions.<br />
Familiar HUBER flexibility is<br />
brought via the “CC” choice<br />
of interchangeable/upgradeable<br />
controllers.<br />
Controller Options<br />
UC006Tw-3<br />
Controller CC1 – Basic and practical<br />
New…User and Administrator levels<br />
New…Digital encoder “turn to search -<br />
push to select”<br />
New…48 character, 4-line LCD display<br />
New…Full character user menu<br />
Visual and audible alarms<br />
Also includes programmable alarm functions<br />
Microprocessor based controller ... and more.<br />
Controller CC2 – External process oriented<br />
All that the CC1 is furnished with plus<br />
Process control capability, Ramping function,<br />
5-step internal programmer ... and more.<br />
Controller CC3 – Automation capable<br />
All that the CC2 is furnished with plus<br />
10-program, 50 step internal programmer<br />
RS232, RS485 and analogue interfaces<br />
... and more.<br />
www.huber-online.com · Tel. +49-781-96030<br />
39
UNICHILLERS in Tower Casings<br />
Unichillers (air cooled bench models)<br />
Model Working Tempera- Pump max. Cooling Power [kW] at [°C] Dimensions [W/dm³] at Cat.No. G Price<br />
ture Range [°C] Type [l/min] [bar] 15 0 -10 -20 W x D x H [mm] 15°C 0°C<br />
UC006T-1* -25..40 A 30 0,7 0,6 0,45 0,25 0,07 350x310x615 9,0 6,7 582.0011 3<br />
UC009T-1* -25..40 A 30 0,7 0,9 0,7 0,48 0,25 350x310x615 13,5 10,5 584.0011 3<br />
UC012T-1* -25..40 A 30 0,7 1,2 1,0 0,7 0,4 350x310x615 18,0 15,0 586.0011 3<br />
* 3 controller options Option heating 2 kW to 100°C<br />
Controller Options<br />
CC1: CC2: CC3:<br />
Basic and practical External process oriented Automation capable<br />
Please see page 37 for full details.<br />
Option:<br />
Natural<br />
Refrigerants<br />
(Page 50...)<br />
UC012T-1 UC016T-3<br />
UC055T-2<br />
Unichillers (air cooled)<br />
Model Working Tempera- Pump max. Cooling Power [kW] at [°C] Dimensions [W/dm³] at Cat.No. G Price<br />
ture Range [°C] Type [l/min] [bar] 15 0 -10 -20 W x D x H [mm] 15°C 0°C<br />
UC016T-1* -10..40 B 22 3,0 1,7 0,9 0,4 - 450x510x1160 6,4 3,4 587.0011 3<br />
UC020T-1* -20..40 B 22 3,0 2,0 2,0 1,3 0,5 450x510x1160 7,5 7,5 588.0011 3<br />
UC025T-1* -10..40 B 22 3,0 2,5 1,2 0,6 - 450x510x1160 9,4 4,5 589.0011 3<br />
UC040T-1* -10..40 B 22 3,0 4,0 2,2 1,0 - 500x550x1265 11,5 6,3 590.0011 3<br />
UC045T-1* -20..40 B 22 3,0 4,5 4,3 2,9 1,5 500x550x1265 12,9 12,4 591.0011 3<br />
UC055T-1* -10..40 C3 65 4,0 5,5 3,0 1,3 - 600x630x1570 9,3 5,1 592.0011 3<br />
UC060T-1* -20..40 C3 65 4,0 6,0 6,0 3,9 1,5 600x630x1570 10,1 10,1 593.0011 3<br />
UC080T-1* -10..40 C3 65 4,0 8,0 4,8 2,5 - 600x730x1570 11,6 7,0 594.0011 3<br />
UC100T-4 -20..40 C3 65 4,0 10,0 10,0 6,5 2,5 600x790x1570 13,4 13,4 595.0006 4<br />
UC110T-4 -10..40 C3 65 4,0 11,0 6,0 2,7 - 600x790x1570 14,8 8,1 596.0006 4<br />
UC130T-4** -10..40 C3 65 4,0 13,0 7,2 3,2 - 874x1185x1870 6,7 3,7 597.0006 4<br />
UC150T-4** -20..40 D3 140 4,0 15,0 15,0 9,7 3,7 874x1485x1870 6,2 6,2 598.0005 4<br />
UC160T-4** -10..40 D3 140 4,0 16,0 8,8 4,0 - 874x1185x1870 8,3 4,5 600.0005 4<br />
UC200T-4** -10..40 D3 140 4,0 20,0 11,0 5,0 - 874x1485x1870 8,2 4,5 601.0005 4<br />
UC210T-4** -20..40 D3 140 4,0 21,0 21,0 13,6 5,2 874x1985x1870 6,5 6,5 602.0005 4<br />
UC250T-4** -10..40 D3 140 4,0 25,0 14,0 6,2 - 874x1985x1870 7,7 4,3 603.0005 5<br />
UC260T-4** -20..40 D3 140 4,0 26,0 26,0 13,6 5,2 874x1985x1870 8,0 8,0 604.0005 5<br />
UC300T-4** -10..40 D3 140 4,0 30,0 16,5 7,5 - 874x1985x1870 9,2 5,1 605.0005 5<br />
UC400T-4** -10..40 D3 140 4,0 40,0 22,0 10,0 - 2500x1685x1800 5,3 2,9 650.0005 5<br />
* 3 controller options ** without trolley Option heating 2 kW to 100°C Dimension may vary slightly<br />
40 www.huber-online.com · Tel. +49-781-96030<br />
Accessories see page 43, 45..
Unichillers (water cooled bench models)<br />
Heating Option<br />
All models (except UC006Tw and UC009Tw)<br />
can be factory-fitted with a heating. The temperature<br />
range is ex ten ded to +100°C. Please<br />
ask for the additional price for the heating.<br />
The model name and Order No. get the addition<br />
“H”. Increased heating powers available<br />
on request.<br />
in Tower Casings UNICHILLERS<br />
Model Working Tempera- Pump max. Cooling Power [kW] at [°C] Dimensions [W/dm³] at Cat.No. G Price<br />
ture Range [°C] Type [l/min] [bar] 15 0 -10 -20 W x D x H [mm] 15°C 0°C<br />
UC006Tw-1* -20..40 A 30 0,7 0,6 0,45 0,4 0,25 230x280x550 16,9 12,7 606.0031 3<br />
UC009Tw-1* -25..40 A 30 0,7 0,9 0,7 0,4 0,2 230x280x550 25,4 22,6 607.0031 3<br />
UC012Tw-1* -25..40 A 30 0,7 1,2 1,0 0,6 0,3 350x310x615 18,0 15,0 611.0011 3<br />
UC015Tw-1* -25..40 A 30 0,7 1,5 1,2 0,8 0,4 350x310x615 22,5 18,0 613.0011 3<br />
UC023Tw-1* -25..40 A 30 0,7 2,3 1,6 0,9 0,5 350x310x615 34,5 24,0 615.0011 3<br />
* 3 controller options Option heating 2 kW to 100°C, except UC006Tw and UC009Tw<br />
UC006Tw-3 UC012Tw-3 UC055Tw-1 UC100Tw-4<br />
Unichillers (water cooled)<br />
Model Working Tempera- Pump max. Cooling Power [kW] at [°C] Dimensions [W/dm³] at Cat.No. G Price<br />
ture Range [°C] Type [l/min] [bar] 15 0 -10 -20 W x D x H [mm] 15°C 0°C<br />
UC016Tw-1* -10..40 B 22 3,0 1,7 0,9 0,4 - 400x440x1100 8,8 4,6 616.0011 3<br />
UC020Tw-1* -20..40 B 22 3,0 2,0 2,0 1,3 0,5 400x440x1100 10,3 10,3 617.0011 3<br />
UC025Tw-1* -10..40 B 22 3,0 2,5 1,2 0,6 - 400x440x1100 12,9 6,2 618.0011 3<br />
UC030Tw-1* -20..40 B 22 3,0 3,0 3,0 2,0 1,0 400x440x1100 15,5 15,5 619.0011 3<br />
UC040Tw-1* -10..40 B 22 3,0 4,0 2,1 0,95 - 400x440x1100 20,7 10,8 620.0011 3<br />
UC055Tw-1* -10..40 C3 65 4,0 5,5 4,0 2,0 - 500x550x1265 15,8 11,5 621.0011 3<br />
UC060Tw-1* -20..40 C3 65 4,0 6,0 6,0 3,8 1,4 500x550x1265 17,2 17,2 622.0011 3<br />
UC080Tw-1* -10..40 C3 65 4,0 8,0 4,65 2,35 - 500x550x1265 23,0 13,4 623.0011 3<br />
UC100Tw-4 -20..40 C3 65 4,0 10,0 10,0 6,3 3,0 600x600x1450 19,2 19,2 624.0005 4<br />
UC110Tw-4 -10..40 C3 65 4,0 11,0 5,8 2,55 - 600x600x1450 21,1 11,1 625.0005 4<br />
UC130Tw-4 -10..40 C3 65 4,0 13,0 7,0 3,0 - 600x600x1450 24,9 13,4 626.0005 4<br />
UC150Tw-4 -20..40 D3 140 4,0 15,0 15,0 10,0 5,0 760x800x1560 15,8 15,8 627.0005 4<br />
UC160Tw-4 -10..40 D3 140 4,0 16,0 9,5 5,5 - 600x600x1450 30,7 18,2 628.0005 4<br />
UC200Tw-4 -10..40 D3 140 4,0 20,0 10,7 4,7 - 760x800x1560 21,1 11,3 629.0005 4<br />
UC210Tw-4 -20..40 D3 140 4,0 21,0 21,0 16,5 10,0 760x800x1560 22,1 22,1 630.0007 4<br />
UC250Tw-4 -10..40 D3 140 4,0 25,0 13,6 5,8 - 760x800x1560 26,4 14,3 631.0005 5<br />
UC260Tw-4 -20..40 D3 140 4,0 26,0 26,0 20,0 12,0 760x800x1560 27,4 27,4 632.0005 5<br />
UC300Tw-4** -10..40 D3 140 4,0 30,0 16,0 7,1 - 760x800x1560 31,6 16,9 633.0005 5<br />
UC400Tw-4** -10..40 D3 140 4,0 40,0 21,0 10,0 - 1000x920x1665 26,1 13,7 634.0005 5<br />
UC500Tw-4** -10..40 D3 140 4,0 50,0 26,0 - - 1000x920x1665 32,6 17,0 635.0005 5<br />
* 3 controller options ** without trolley Option heating 2 kW to 100°C Dimension may vary slightly<br />
Accessories see page 43, 45..<br />
www.huber-online.com · Tel. +49-781-96030<br />
Option:<br />
Natural<br />
Refrigerants<br />
(Page 50...)<br />
41
42<br />
UNICHILLERS Specials<br />
ROTACOOL – a Co-product<br />
Unichiller ETH<br />
Unichillers are intelligent circulation<br />
coolers which have been specially designed<br />
to operate under the workbench<br />
and in general to be connected to an<br />
air-extract duct. The refrigeration unit is<br />
a development, in terms of thermodynamics,<br />
of the unique Unistat Tan go unit.<br />
The term Unichiller indicates that it is universally<br />
suitable for heat dissipation.<br />
Air-cooled refrigeration units which operate<br />
under the workbench or in similarly<br />
con fined areas usually cause heat<br />
to accumu late. Integrated Unichillers are<br />
both air- and water-cooled. The waste<br />
heat can therefore be removed either<br />
using air or cooling water, as desired.<br />
The unit will automati cally switch to water-cooled<br />
operation if the cooling-water<br />
supply is connected. The unit will automatically<br />
switch to air-cooled operation<br />
if the water is not connected or if there<br />
is no cooling-water supply.<br />
Model Working Temperature Cooling Power [kW] at [°C] Pump max. Dimensions Cat.No. G Price<br />
Range [°C] 15 0 -10 [l/min] [bar] W x D x H [mm]<br />
Unichiller ETH-1 wl -10..40 2,5 2,0 1,2 30 1,4 460x615x760 673.0011 3<br />
Unichiller ETH-2 wl -10..40 2,5 2,0 1,2 30 1,4 460x615x760 673.0012 3<br />
Unichiller ETH-3 wl -10..40 2,5 2,0 1,2 30 1,4 460x615x760 673.0013 3<br />
The „Rotacool“ is a product co-developed<br />
with Heidolph to provide a dedicated<br />
cooling service to small bench top<br />
Rotary Evaporators.<br />
Benefits are:<br />
– Independent cooling for individual<br />
rotary evaporators<br />
– Non-reliance on un-predictable<br />
house water supplies<br />
– Consumes no additional bench space,<br />
the rotary evaporator sits on top<br />
– Compact and powerful<br />
Also available from:<br />
Heidolph Instruments GmbH & Co. KG<br />
Walpersdorferstrasse 12, D-91126 Schwabach<br />
Tel. 09122-9920-69<br />
E-Mail: Heidolph.Instruments@Heidolph.de<br />
Internet: www.heidolph.com<br />
From a customer in New Zealand „…I’ve had<br />
a regular trickle of inquisitive people into the<br />
lab to view the Rotacool. I ran it with DCM and<br />
our house vacuum. Using 200 ml in the flask,<br />
I normally recover less than 50 ml. With the<br />
Rotacool down at -10 I got 175 ml and with it<br />
starting off at -20 I got 195 ml back so it does a<br />
superb job of saving our vacuum system“.<br />
Model Working Temperature Cooling Power [kW] at [°C] Pump max. Dimensions Cat.No. G Price<br />
Range [°C] 15 0 -10 [l/min] [bar] W x D x H [mm]<br />
RotaCool -20..40 0,42 0,35 0,22 10 0,2 470x580x420 659.0001 3<br />
www.huber-online.com · Tel. +49-781-96030<br />
Option:<br />
Natural<br />
Refrigerants<br />
(Page 50...)<br />
Option:<br />
Natural<br />
Refrigerants<br />
(Page 50...)<br />
Accessories see page 43, 45..
Pump Pump duty [l/min] at [bar]<br />
0,2 0,5 1,0 2,0 2,5 3,0 4,0<br />
A 20 10 – – – – –<br />
B* 22 20 17 10 – 5 –<br />
B1* – 40 35 28 24 20 10<br />
C3** – – 65 60 45 40 25<br />
C4* ** – – 80 75 75 60 30<br />
D3** – – 140 120 110 90 50<br />
*Stronger pump options available from UC006T and UC012Tw and above ** Pump suitable for UC055 and above<br />
Pump Reduction in cooling power Price<br />
B for A 150 W<br />
B1 for B 150 W<br />
C4 for C3 400 W<br />
D3 for C3 750 W<br />
D3 for C4 350 W<br />
Ocassionally it might be necessarry to increase the unit housing to the next bigger size.<br />
Sensors (standard cable length 1,5 m) Cat.No. G Price<br />
Ø 6 mm 180 mm 6138 1<br />
with handle Ø 6 mm 200 mm 6105 1<br />
Ø 8 mm 400 mm 6064 1<br />
mounted in protective pipe Ø 8 mm 170 mm 6205 1<br />
M16x1 sensor for flow or return 6352 1<br />
M16x1 sensor for flow or return double 6353 1<br />
M30x1,5 sensor for flow or return 6509 1<br />
M30x1,5 sensor for flow or return double 6363 1<br />
Extension cable Pt100, 3m 6292 1<br />
Control cables Compatible Control Cat.No. G Price<br />
CC RS232 / PC RS232 (3m) 6198 1<br />
CC RS485 / open (3m) 6236 1<br />
CC AIF / POKO open (3m) 6218 1<br />
CC AIF / open (3m) 6320 1<br />
CC complete / open (3m) 6319 1<br />
Y cable PC / AIF 6651 1<br />
15-pole plug (plug only, no cable) 6335 1<br />
Communication cables Control Panel CP (standard cable length 3 m) Cat.No. G Price<br />
from to Note<br />
CP PC RS232 6146 1<br />
CP Unistat controller Extension cable for control panel 6147 1<br />
CP RS485 Cable end open 6279 1<br />
CP Analog Cable end open 6254 1<br />
CP Remote control CC3 6737 1<br />
Y cable unistat/PC + analogue 6326 1<br />
Other accessories Cat.No. G Price<br />
Float switch 6173 1<br />
Trolley UC015 6235 2<br />
Weather resistant option on request<br />
Accessories UNICHILLERS<br />
Pumps<br />
Instead of the standard pump you can<br />
get stronger pumps for systems with a<br />
<strong>high</strong>er pressure drop.<br />
The bench top models with standard<br />
pump A are for external closed systems<br />
only. The air-cooled models UC006T to<br />
UC012T and the water-cooled models<br />
UC012Tw to UC023Tw (not UC006Tw<br />
and UC009Tw) are also available with a<br />
stronger pump B which allows the temperature<br />
control of open baths and closed<br />
systems. Model names and Cat.No. will<br />
then get the additional induction ‚B‘<br />
(e.g. UC012Tw-3 B, Cat.No. 611.0013B).<br />
External Pt100 sensors<br />
For external <strong>thermoregulation</strong> applications<br />
there are different sensors available.<br />
Special versions can be made on<br />
request.<br />
Control cables for use with<br />
CC controllers<br />
Control cables (for CC3) allow remote<br />
control via the RS232, RS485 or the analogue<br />
interfaces (AIF). Open ends allow<br />
flexibility to connect as required.<br />
Control cables for use with<br />
Unistat Control<br />
Control cable for use with RS232, RS485<br />
or analogue interface (AIF). Control cables<br />
can be configured to request.<br />
Other accessories<br />
www.huber-online.com · Tel. +49-781-96030<br />
43
SPECIALS Models<br />
Hotbox<br />
HOTBOX – really hot units are the new,<br />
compact recircu lators to maintain the<br />
temperature of externally open systems.<br />
Safety first: The safety standards of industry<br />
and research are reached with an<br />
adjustable overheat protection and level<br />
protection (pressure switch). Casing and<br />
pump made of stainless steel. HB2-HB5<br />
with swirl ca s tors. The temperature is<br />
controlled with the exchan ge able microprocessor<br />
controllers CC1, CC2 or CC3<br />
with 3 years warranty.<br />
Controller Options<br />
CC1: CC2: CC3:<br />
Basic and practical External process oriented Automation capable<br />
Please see page 37 for full details.<br />
Beer „Force Ageing“<br />
Thermostats<br />
We offer a special air- or water chilled<br />
chiller unit for the Beer Forcier-Test. Both<br />
models are equipped with a comfortable<br />
programmer for the usual change between<br />
0°C and 60°C in the usual 24 hour<br />
cycle. The BFT 2 is for 20 bottles in the<br />
original Eurobox.<br />
The CFC free units comply with the safety<br />
class FL, III. Ca sings and bath parts are<br />
made of Stainless steel.<br />
HB1-3<br />
HB5-3<br />
Model Working Tempera- Pump Connections Heating Power Dimensions Cat.No. G Price<br />
ture Range [°C] [l/min] [bar] [kW] W x D x H [mm]<br />
Hotbox HB1 -1 45..250 M16x1 18 at 0,5 4,5 180x430x360 290.0051 3<br />
Hotbox HB2 -1 60..250 M16x1 25 at 0,5 6,0 455x320x500 290.0061 3<br />
Hotbox HB3 -1 60..250 M30x1,5 50 at 0,5 6,0 455x320x500 290.0071 3<br />
Hotbox HB4 -1 60..250 M30x1,5 50 at 0,5 12,0 455x320x500 290.0081 3<br />
Hotbox HB5 -1 60..250 M30x1,5 56 at 0,5 12,0 455x320x500 290.0091 3<br />
3 controller options<br />
BFT1-2 BFT2w-2<br />
Model Working Tempera- Bath Opening Bath Depth Heating Power Cooling Power Dimensions Cat.No. G Price<br />
ture Range W x D at 20°C W x D x H<br />
[°C] [mm] [mm] [kW] [kW] [mm]<br />
BFT 1-2 0..80 280x280 150 2,0 1,0 420x590x700 569.0005 2<br />
BFT 1w-2 0..80 280x280 150 2,0 1,0 420x590x700 569.0006 2<br />
BFT 2-2 0..80 530x400 360 3,0 2,5 670x720x1070 249.0005 2<br />
BFT 2w-2 0..80 530x400 360 3,0 2,5 670x720x1070 249.0006 2<br />
BFT 4-2 0..80 300x400 300 2,0 0,35 540x600x775 414.0001 2<br />
also available with controller CC3<br />
44 www.huber-online.com · Tel. +49-781-96030<br />
Option:<br />
Natural<br />
Refrigerants<br />
(Page 50...)<br />
Accessories see page 45..
DW-Therm -90°C...+200°C<br />
Specifications<br />
Appearance and odour: transparent, colourless or yellow<br />
liquid with characteristic odour<br />
Silane content: 99%<br />
Viscosity: 2,0-2,2 mm²/sec at 20°C<br />
Density: 0,88 g/cm³ at 15°C<br />
Boiling range: 228-235°C<br />
Solidification at: -137°C<br />
Flash point: 101°C<br />
Ignition temperature: 265°C<br />
Properties<br />
DW-Therm is a mixture of isometric triethoxysilanes and has<br />
been developed for hydraulically sealed systems.<br />
Notes<br />
– broad working range from -90°C to +200°C (hydraulically<br />
sealed systems)<br />
– excellent thermooxidative stability at <strong>high</strong> temperatures<br />
– low viscosity at low temperatures<br />
– low volatility and pleasant odour<br />
– easy handling (no creeping like silicone oils)<br />
– good compatibility with silicone oils<br />
– insoluble in water and environmentally friendly<br />
– no known toxicity<br />
DW-Therm HT +20°C...+330°C<br />
Specifications<br />
Appearance: clear, orange coloured liquid<br />
Content: 99,5% partially hydrogenated<br />
terphenyls<br />
kinematic viscosity: 101 mm²/sec at 20°C<br />
Density: 1,004 g/cm³ at 20°C<br />
Boiling starts at: approx. 350°C<br />
Pour point: -33°C<br />
Flash point: approx. 190°C<br />
Ignition temperature: approx. 390°C<br />
Properties<br />
DW-Therm HT is a mixture of partially hydrogenated terphenyls.<br />
It is especially suited for <strong>high</strong> temperature applications<br />
using hydraulically sealed thermostats.<br />
Notes<br />
– broad working range from +20°C to +330°C<br />
(hydraulically sealed system)<br />
– long lifetime at <strong>high</strong> temperatures under inert atmosphere:<br />
3-4 years<br />
– good thermal properties for heat transfer<br />
– <strong>high</strong> oxidation stability<br />
– not classified as dangerous goods, no known toxicity<br />
More information available at www.dws-synthese.de<br />
Thermal Fluids ACCESSORIES<br />
Operating range of thermal fluids<br />
P20.330.90: plus 20°C +330°C 90 mm²/s at 25°C<br />
M40.165.10: minus 40°C +165°C 10 mm²/s at 25°C<br />
-120 -100 -80 -60 -40 -20 0 +20 +40 +60 +80 +100 +200 +300<br />
M120.M08.02<br />
DW-Therm M90.200.02<br />
M90.055.03<br />
M80.055.03<br />
M60.115.05<br />
M40.165.10<br />
M20.235.20<br />
M10.155.08<br />
DW-Therm HT P20.330.90<br />
P20.190.40<br />
P20.275.50<br />
-120 -100 -80 -60 -40 -20 0 +20 +40 +60 +80 +100 +200 +300<br />
Thermal Fluid (G1) Litre Cat.No. Price<br />
DW-Therm* M90.200.02 10 6479<br />
DW-Therm HT* P20.330.90 5 6672<br />
10 6673<br />
MinOil P20.190.40 5 6155<br />
20 6156<br />
SynOil M10.155.08 5 6159<br />
10 6160<br />
SilOil P20.275.50 5 6157<br />
10 6158<br />
SilOil M20.235.20 5 6161<br />
10 6162<br />
SilOil M40.165.10 5 6163<br />
10 6164<br />
SilOil M60.115.05 5 6165<br />
10 6166<br />
SilOil M80.055.03 5 6167<br />
10 6168<br />
SilOil M80.100.03 5 6275<br />
10 6276<br />
SilOil M90.055.03 5 6258<br />
10 6259<br />
Kryothermal S M120.M08.02 5 6282<br />
Antifreeze (Ethylenglycol) 10 6170<br />
50 6171<br />
Algae Protection 0,1 6172<br />
* exclusive for Unistats<br />
www.huber-online.com · Tel. +49-781-96030<br />
45
ACCESSORIES General<br />
M16x1<br />
M24x1,5<br />
M30x1,5<br />
M38x1,5<br />
1/2“<br />
3/4“<br />
Accessories M16x1 (G1) Cat.No. Price<br />
Hose Connector NW 8 6086<br />
Hose Connector NW 12 6087<br />
Blank Plug 6088<br />
Nut 6089<br />
Micro Hose Connector NW 3,2 6090<br />
90° Adaptor 6195<br />
Ball Valve 6091<br />
2-way Header 6194<br />
3-way Header 6193<br />
4-way Header 6187<br />
5-way Header 6815<br />
2-way Valve System 6284<br />
3-way Valve System 6285<br />
4-way Valve System 6286<br />
5-way Valve System 6816<br />
Accessories M24x1,5 (G1) Cat.No. Price<br />
90° Adaptor 9256<br />
Ball Valve 9236<br />
2-way Header 9233<br />
3-way Header 9234<br />
4-way Header 9235<br />
2-way Valve System 9245<br />
3-way Valve System 9246<br />
4-way Valve System 9247<br />
Accessories M30x1,5 (G1) Cat.No. Price<br />
90° Adaptor 6461<br />
Ball Valve 6451<br />
2-way Header 6420<br />
3-way Header 6421<br />
4-way Header 6422<br />
2-way Header with Ball Valves 6423<br />
3-way Header with Ball Valves 6463<br />
4-way Header with Ball Valves 6464<br />
Accessories M38x1,5 (G1) Cat.No. Price<br />
90° Adaptor 6699<br />
Ball Valve 6700<br />
2-way Header 6706<br />
3-way Header 6707<br />
4-way Header 6708<br />
2-way Valve System 6709<br />
3-way Valve System 6710<br />
4-way Valve System 6711<br />
Accessories 1/2“ and 3/4“ (G1) Cat.No. Price<br />
Hose connections 1/2“ 2294<br />
for 3/8“ hose<br />
Hose connections 3/4“ 2295<br />
for 1/2“ hose<br />
46 www.huber-online.com · Tel. +49-781-96030<br />
Adaptors<br />
Adaptor (G1) Cat.No. Price<br />
M16x1 male to M16x1 male 6278<br />
M16x1 female to M16x1 female 6359<br />
M16x1 male to 1/2“ male 6299<br />
M16x1 male to 1/2“ female 6364<br />
M16x1 female to 1/2“ male 6360<br />
M16x1 female to 1/2“ female 6229<br />
M16x1 male to 3/4“ female 5443<br />
M16x1 female to 3/4“ female 6361<br />
M16x1 female to M30x1,5 male 6431<br />
M16x1 male to M30x1,5 male 6449<br />
M16x1 male to M30x1,5 female 6454<br />
M24x1,5 female to M30x 1,5 male 6723<br />
M24x1,5 female to M16x1 male 6724<br />
M24x1,5 female to 3/4“ NPT female 6874<br />
M24x1,5 male to M16x1 female 6945<br />
M30x1,5 male to M30x1,5 male 6448<br />
M30x1,5 female to 3/8“ male 6445<br />
M30x1,5 male to 1/2“ male 6393<br />
M30x1,5 male to 1/2“ female 6394<br />
M30x1,5 female to 1/2“ male 6391<br />
M30x1,5 female to 1/2“ female 6392<br />
M30x1,5 male to 3/4“ male 6447<br />
M30x1,5 male to 3/4“ female 6442<br />
M30x1,5 female to 3/4“ NPT male 6472<br />
M30x1,5 female to 3/4“ female 6452<br />
M30x1,5 male to 1“ male 6444<br />
M30x1,5 female to 1“ female 6453<br />
1/2“ female to 1/2“ female 6358<br />
1/2“ female to 3/4“ NPT female 6356<br />
M38x1,5 female to 1“ NPT male 6600<br />
M38x1,5 female to M30x1,5 male 6612<br />
M38x1,5 female to 3/4“ male 6665<br />
Other adaptors on request
Hoses<br />
Hose max. [°C] Length Cat.No. G Price<br />
NW 3,2 PVC 60 variable 6072 1<br />
NW 8 PVC 60 variable 6071 1<br />
NW 12 PVC 60 variable 6070 1<br />
NW 8 Perbunan 120 variable 6075 1<br />
NW 12 Perbunan 120 variable 6073 1<br />
NW 8 Silicon 180 variable 6077 1<br />
NW 12 Silicon 180 variable 6076 1<br />
NW 8 Viton 200 variable 6079 1<br />
NW 12 Viton 200 variable 6078 1<br />
NW 8 Teflon 200 variable 6350 1<br />
NW 12 Teflon 200 variable 6351 1<br />
Insulated hose Temperature Length Cat.No. G Price<br />
Range<br />
NW 10 M16x1 -100...350°C 100 cm 6084 1<br />
NW 10 M16x1 -100...350°C 150 cm 6085 1<br />
NW 10 M16x1 -100...350°C 200 cm 6136 1<br />
NW 10 M16x1 -100...350°C 300 cm 6255 1<br />
NW 12 M24x1,5 -120...400°C 100 cm 6784 1<br />
NW 12 M24x1,5 -120...400°C 150 cm 6785 1<br />
NW 12 M24x1,5 -120...400°C 200 cm 6786 1<br />
NW 12 M24x1,5 -120...400°C 300 cm 6787 1<br />
NW 20 M30x1,5 -100...350°C 100 cm 6426 1<br />
NW 20 M30x1,5 -100...350°C 150 cm 6386 1<br />
NW 20 M30x1,5 -100...350°C 200 cm 6427 1<br />
NW 20 M30x1,5 -100...350°C 300 cm 6428 1<br />
NW 25 M38x1,5 -100...350°C 100 cm 6655 1<br />
NW 25 M38x1,5 -100...350°C 150 cm 6656 1<br />
NW 25 M38x1,5 -100...350°C 200 cm 6657 1<br />
NW 25 M38x1,5 -100...350°C 300 cm 6658 1<br />
Cooling Water Hoses<br />
Cooling Water Hose Temperature Length Cat.No. G Price<br />
(Flexible braided hose) Range<br />
1/2“ -10...100°C 100 cm 16851 1<br />
1/2“ -10...100°C 150 cm 16852 1<br />
1/2“ -10...100°C 200 cm 16853 1<br />
3/4“ -10...100°C 100 cm 16854 1<br />
3/4“ -10...100°C 150 cm 16855 1<br />
3/4“ -10...100°C 200 cm 16856 1<br />
1“ -10...100°C 100 cm 16857 1<br />
1“ -10...100°C 150 cm 16858 1<br />
1“ -10...100°C 200 cm 16859 1<br />
General ACCESSORIES<br />
Hose insulation Digital thermometer<br />
Hose insulation Internal Ø Thickness Cat.No. G Price<br />
For hose:<br />
For metal hose:<br />
13 mm 7 mm NW 8 6083 1<br />
17 mm 7 mm NW 12 6082 1<br />
17 mm 12 mm NW 12 3968 1<br />
42 mm 22 mm M16x1 6375 1<br />
57 mm 23 mm M30x1,5 6377 1<br />
50 mm 22 mm 1/2“ 6376 1<br />
for precise temperature measurement<br />
from -60 to +400°C<br />
Digital thermometer D400 Cat.No. Price<br />
(G1)<br />
Digital thermometer D400 307.0001<br />
Handle D400 for dense masses 6116<br />
Imitation leather pocket for D400 6190<br />
Battery 9V IEC 6F22 (pack of 3) 6191<br />
Heat transfer paste 15 g 6122<br />
Heat transfer paste 50 g 6149<br />
www.huber-online.com · Tel. +49-781-96030<br />
47
QUICK FINDER<br />
Quick Finder Thermostats<br />
Low<br />
Demand<br />
„A“ Series<br />
„B“ Series<br />
VPC Range<br />
304B Series<br />
308B Series<br />
315B Series<br />
Above 30°C<br />
Heating<br />
High<br />
Demand<br />
Internal<br />
(e.g. Sample immersion,<br />
test tubes etc.)<br />
Below 30°C<br />
Heating + Cooling<br />
Low<br />
Demand<br />
„K“ Series<br />
„DC“ Series<br />
„TC“ Series<br />
VPC Range<br />
Variostat<br />
Ministat Series<br />
48 www.huber-online.com · Tel. +49-781-96030<br />
High<br />
Demand<br />
Thermal Control<br />
Required<br />
Open Bath Systems<br />
80°C…400°C<br />
Heating<br />
Unistat range<br />
CC400 Series<br />
CC401 Series<br />
Unistat range<br />
T326 Series<br />
T327 Series<br />
Unistat range<br />
Tango<br />
34x Series<br />
14x Series<br />
15x Series<br />
16x Series<br />
36x Series<br />
38x Series<br />
39x Series<br />
29x Series<br />
42x Series<br />
External<br />
(e. g. reactor,<br />
reaction block, rotary<br />
evap. etc.)<br />
100°C…300°C<br />
Heating<br />
Low Volume Sealed<br />
Systems<br />
-120°C…300°C<br />
Heating +<br />
Cooling
Quick Finder Chillers<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
QUICK FINDER<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
www.huber-online.com · Tel. +49-781-96030<br />
49
TECHNICAL DATA<br />
Model<br />
Catalogue Page<br />
COMPATIBLE CONTROL THERMOSTATS<br />
Temperature Range<br />
Tmin with cooling<br />
Tmin with water cooling<br />
Heating Power<br />
Bath Volume<br />
min. Filling Capacity<br />
Bath Volume with<br />
Displacement Insert<br />
Bath Opening WxDxH<br />
Resolution of Display<br />
CC1-E 7 25...200 -30 20 2 0.1 0.02<br />
CC1-300B2X vpc 7 28...300 -20 2 0.1 0.02<br />
CC1-300B4X vpc 7 28...300 -20 3.0 / 4.0 0.1 0.02<br />
CC1-105A 8 25...100 -30 20 2 5 5 120x110x150 0.1 0.02<br />
CC1-106A 8 25...100 -30 20 2 6 6 120x210x150 0.1 0.02<br />
CC1-107A 8 25...100 -30 20 2 7 7 120x310x150 0.1 0.02<br />
CC1-111A 8 25...100 -30 20 2 11 11 302x165x150 0.1 0.02<br />
CC1-118A 8 25...100 -30 20 2 18 18 302x325x150 0.1 0.02<br />
CC1-130A Visco 3 8 20...80 20 2 31 90x90x370 0,01 0,01<br />
CC1-130A Visco 5 8 20...80 20 2 31 Ø51x370 0,01 0,01<br />
CC1-208B 9 25...200 -30 20 2 8.5 8.5 235x165x150 0.1 0.02<br />
CC1-212B 9 25...200 -30 20 2 12 12 295x193x150 0.1 0.02<br />
CC1-215B 9 25...200 -30 20 2 15 15 295x193x200 0.1 0.02<br />
CC1-220B 9 25...200 -30 20 2 20 20 295x370x150 0.1 0.02<br />
CC1-225B 9 25...200 -30 20 2 25 25 295x370x200 0.1 0.02<br />
CC1-202C 10 45...200 -30 20 2 1.8 1.8 Ø25x150 0.1 0.05<br />
CC1-205B 10 45...200 -30 20 2 4.5 3.1 3.1 105x90x150 0.1 0.05<br />
CC1-304B vpc 10 28...300 -20 2 4 100x130x145 0.1 0.02<br />
CC1-308B vpc 10 28...300 -20 3 8.5 5.2 130x110x155 0.1 0.02<br />
CC1-315B vpc 10 28...300 -20 3.0 / 4.0 15 8.5 270x145x200 0.1 0.02<br />
CC1-K12 11 -20...200 2 12 8 295x193x150 0.1 0.02 0.18<br />
CC1-K15 11 -20...200 2 15 11 295x193x200 0.1 0.02 0.2<br />
Cooling Power at<br />
CC1-K20 11 -30...200 2 20 12 295x370x150 0.1 0.02 0.35 0.21<br />
CC1-K25 11 -30...200 2 25 17 295x370x200 0.1 0.02 0.35 0.21<br />
variostat cc-1 12 -30...150 1 0.1 0.02 0.3 0.3 0.2 0.12<br />
CC1-K6 13 -25...200 2 4.5 150x140x150 0.1 0.02 0.15 0.05<br />
ministat 125-1 14 -25...150 1 2.75 1.3 178x80x120 0.1 0.02 0.3 0.3 0.21 0.05<br />
ministat 125w-1 14 -25...150 1 2.75 1.3 178x80x120 0.1 0.02 0.3 0.3 0.2 0.1<br />
ministat 230-1 14 -33...200 2 3.2 1.7 170x83x135 0.1 0.02 0.4 0.4 0.35 0.25<br />
ministat 230w-1 14 -33...200 2 3.2 1.7 170x83x135 0.1 0.02 0.4 0.4 0.35 0.25<br />
ministat 240-1 14 -40...200 2 4.9 2.8 200x85x157 0.1 0.02 0.55 0.55 0.5 0.35 0.03<br />
ministat 240w-1 14 -40...200 2 4.9 2.8 200x85x157 0.1 0.02 0.55 0.55 0.5 0.35 0.03<br />
CC1-305 vpc 16 -30...150 1.5 20 300x330x150 0.1 0.02 0.35 0.35 0.35 0.23<br />
CC1-405 vpc 16 -40...200 1.5 5 120x110x150 0.1 0.02 0.7 0.7 0.7 0.45 0.03<br />
CC1-405w vpc 16 -40...200 1.5 5 120x110x150 0.1 0.02 0.7 0.7 0.7 0.45 0.03<br />
CC1-415 vpc 16 -40...200 1.5 5 120x110x150 0.1 0.02 1.2 1.2 1 0.6 0.05<br />
CC1-415wl vpc 16 -40...200 1.5 5 120x110x150 0.1 0.02 1.2 1.2 1 0.6 0.05<br />
CC1-410wl vpc 16 -45...200 1.5 / 4.5 22 8.5 280x280x200 0.1 0.02 0.8 0.8 0.8 0.5 0.1<br />
CC1-505 vpc 17 -50...200 1.5 5 120x110x150 0.1 0.02 1.2 1.2 1 0.6 0.15<br />
CC1-505wl vpc 17 -50...200 1.5 5 120x110x150 0.1 0.02 1.2 1.2 1 0.6 0.15<br />
CC1-510 vpc 17 -50...100 3 18 11 270x150x200 0.1 0.02 2.1 2.1 2.1 1 0.4<br />
CC1-510w vpc 17 -50...100 3 18 11 270x150x200 0.1 0.02 2.4 2.4 2.4 1 0.4<br />
CC1-515 vpc 17 -55...100 3 26 15 260x260x200 0.1 0.02 3.3 3.3 3.3 1.6 0.6<br />
CC1-515w vpc 17 -55...100 3 18 11 270x150x200 0.1 0.02 3.3 3.3 3.3 1.6 0.6<br />
CC1-520w vpc 17 -55...100 3 17 10 270x150x200 0.1 0.02 5 5 5 3 1.5<br />
CC1-525w vpc 17 -55...100 3 17 10 270x150x200 0.1 0.02 7 7 5 3 1.5<br />
Temperature Stability<br />
300°C<br />
200°C<br />
100°C<br />
20°C<br />
0°C<br />
-20°C<br />
-40°C<br />
-60°C<br />
-80°C<br />
-100°C<br />
°C °C °C kW l l l mm K K kW kW kW kW kW kW kW kW kW kW<br />
CC1-705 vpc 18 -75...100 1.5 5 120x110x150 0.1 0.02 0.25 0.25 0.25 0.2 0.15 0.1<br />
CC1-805 vpc 18 -80...100 1.5 5 120x110x150 0.1 0.02 0.5 0.5 0.5 0.4 0.3 0.3<br />
CC1-820 vpc 18 -80...100 3 17 10 270x150x200 0.1 0.02 1.2 1.2 1.2 1.1 0.9 0.5 0.14<br />
CC1-820w vpc 18 -80...100 3 17 10 270x150x200 0.1 0.02 1.2 1.2 1.2 1.1 0.9 0.5 0.14<br />
Models with CC1 controller: Technical Data remains identical with controller change (CC2, CC3) FL = Suitable for inflammable and non-inflammable fluids<br />
50 www.huber-online.com · Tel. +49-781-96030
max. Flow Rate - Pressure Pump<br />
max. Press - Pressure Pump<br />
max. Flow Rate - Suction Pump<br />
max. Press - Suction Pump<br />
Pump Connection<br />
Circulation Pump<br />
Safety Standard<br />
Low Level Protection<br />
Overtemperature Protection<br />
Dimensions WxDxH<br />
TECHNICAL DATA<br />
Power supply<br />
Cooling of refrigeration machine<br />
l/min bar l/min bar mm kg V; Hz °C °C<br />
10 0.2 FL Yes Yes 120x135x300 4 230;50/60 5 32 688.0051 CC1-E<br />
Weight<br />
min. Ambient Temperature<br />
max. Ambient Temperature<br />
Natural Refrigerant**<br />
Cat.No.<br />
Cooling Water Connection<br />
33 0.7 22 0.4 M16x1 FL Yes Yes 345x190x380 11 230;50/60 5 32 683.0011BX CC1-300B2X vpc<br />
34 0.7 22 0.4 M16x1 FL Yes Yes 345x190x395 13 230;50/60 / 400;3~N;50* 5 32 684.0011BX CC1-300B4X vpc<br />
10 0.2 M16x1 FL Yes Yes 132x280x320 4.5 230;50/60 5 32 405.0001 CC1-105A<br />
10 0.2 M16x1 FL Yes Yes 132x380x320 5 230;50/60 5 32 405.0011 CC1-106A<br />
10 0.2 M16x1 FL Yes Yes 132x480x320 5 230;50/60 5 32 405.0021 CC1-107A<br />
10 0.2 M16x1 FL Yes Yes 333x313x325 6.5 230;50/60 5 32 405.0031 CC1-111A<br />
10 0.2 M16x1 FL Yes Yes 333x473x325 8 230;50/60 5 32 405.0041 CC1-118A<br />
10 0.2 FL Ja Ja 500x200x560 11 230;50/60 5 32 405.0051 CC1-130A Visco 3<br />
10 0,2 FL Ja Ja 500x200x560 11 230;50/60 5 32 405.0061 CC1-130A Visco 5<br />
10 0.2 M16x1 FL Yes Yes 290x350x375 10 230;50/60 5 32 407.0001 CC1-208B<br />
10 0.2 M16x1 FL Yes Yes 350x375x375 11 230;50/60 5 32 407.0011 CC1-212B<br />
10 0.2 M16x1 FL Yes Yes 350x375x420 12 230;50/60 5 32 407.0021 CC1-215B<br />
10 0.2 M16x1 FL Yes Yes 350x555x375 14 230;50/60 5 32 407.0031 CC1-220B<br />
10 0.2 M16x1 FL Yes Yes 350x555x420 16 230;50/60 5 32 407.0041 CC1-225B<br />
10 0.2 M16x1 FL Yes Yes 150x215x350 7.5 230;50/60 5 32 685.0011 CC1-202C<br />
10 0.2 M16x1 FL Yes Yes 150x285x350 8.5 230;50/60 5 32 686.0011 CC1-205B<br />
34 0.7 22 0.4 M16x1 FL Yes Yes 210x310x390 13 230;50/60 5 32 679.0001 CC1-304B vpc<br />
33 0.7 22 0.4 M16x1 FL Yes Yes 240x405x390 18 230;50/60 5 32 683.0021 CC1-308B vpc<br />
34 0.7 22 0.4 M16x1 FL Yes Yes 335x385x430 22 230; 50/60 / 400;3~N;50* 5 32 684.0011 CC1-315B vpc<br />
10 0.2 M16x1 FL Yes Yes 350x558x375 24 230;50 AIR 5 32 S 653.0021 CC1-K12<br />
10 0.2 M16x1 FL Yes Yes 350x558x420 28 230;50 AIR 5 32 S 645.0031 CC1-K15<br />
10 0.2 M16x1 FL Yes Yes 350x558x550 34 230;50/60 AIR 5 32 S 646.0031 CC1-K20<br />
10 0.2 M16x1 FL Yes Yes 350x558x600 36 230;50/60 AIR 5 32 S 647.0031 CC1-K25<br />
18 0.6 12 0.3 M16x1 FL Yes Yes 183x455x395 24 230;50/60 AIR 5 32 O 654.0011 variostat cc-1<br />
10 0.2 M16x1 FL Yes Yes 210x370x535 20 230;50 AIR 5 32 O 666.0021 CC1-K6<br />
27 0.7 20 0.4 M16x1 FL Yes Yes 225x370x360 25 230;50 AIR 5 32 O 740.0001 ministat 125-1<br />
27 0.7 20 0.4 M16x1 FL Yes Yes 225x370x360 25 230;50 WATER 5 32 1/2“ O 740.0011 ministat 125w-1<br />
27 0.7 20 0.4 M16x1 FL Yes Yes 255x450x400 35 230;50 AIR 5 32 O 741.0001 ministat 230-1<br />
27 0.7 20 0.4 M16x1 FL Yes Yes 255x450x400 35 230;50 WATER 5 32 1/2“ O 741.0011 ministat 230w-1<br />
27 0.7 20 0.4 M16x1 FL Yes Yes 300x465x455 41 230;50 AIR 5 32 O 742.0001 ministat 240-1<br />
27 0.7 20 0.4 M16x1 FL Yes Yes 300x465x455 41 230;50 WATER 5 32 1/2“ O 742.0011 ministat 240w-1<br />
33 0.7 22 0.4 M16x1 FL Yes Yes 350x575x600 43 230;50 AIR 5 32 O 690.0011 CC1-305 vpc<br />
33 0.7 22 0.4 M16x1 FL Yes Yes 370x480x660 55 230;50/60 AIR 5 32 O 697.0011 CC1-405 vpc<br />
33 0.7 22 0.4 M16x1 FL Yes Yes 370x480x660 55 230;50/60 WATER 5 32 1/2“ O 697.0021 CC1-405w vpc<br />
33 0.7 22 0.4 M16x1 FL Yes Yes 410x480x720 60 230;50/60 / 400;3~N;50* AIR 5 32 O 694.0011 CC1-415 vpc<br />
33 0.7 22 0.4 M16x1 FL Yes Yes 410x480x720 62 230;50/60 / 400;3~N;50* AIR+WATER 5 32 1/2“ O 694.0021 CC1-415wl vpc<br />
33 0.7 22 0.4 M16x1 FL Yes Yes 420x590x700 72 230;50 / 400;3~N;50* AIR+WATER 5 32 1/2“ O 695.0011 CC1-410wl vpc<br />
33 0.7 22 0.4 M16x1 FL Yes Yes 410x480x720 60 230;50/60 / 400;3~N;50* AIR 5 32 O 696.0011 CC1-505 vpc<br />
33 0.7 22 0.4 M16x1 FL Yes Yes 410x480x720 62 230;50/60 / 400;3~N;50* AIR+WATER 5 32 1/2“ O 696.0021 CC1-505wl vpc<br />
31 0.6 24 0.35 M16x1 FL Yes Yes 455x515x995 99 400;3~N;50 AIR 5 32 O 564.0021 CC1-510 vpc<br />
31 0.6 24 0.35 M16x1 FL Yes Yes 455x515x995 96 400;3~N;50 WATER 5 32 1/2“ O 564.0031 CC1-510w vpc<br />
31 0.6 24 0.35 M16x1 FL Yes Yes 600x700x1130 98 400;3~N;50 AIR 5 32 O 651.0011 CC1-515 vpc<br />
31 0.6 24 0.35 M16x1 FL Yes Yes 455x515x995 98 400;3~N;50 WATER 5 32 1/2“ O 651.0021 CC1-515w vpc<br />
31 0.6 24 0.35 M16x1 FL Yes Yes 540x630x1085 142 400;3~N;50 WATER 5 32 1/2“ O 698.0011 CC1-520w vpc<br />
31 0.6 24 0.35 M16x1 FL Yes Yes 540x630x1085 142 400;3~N;50 WATER 5 32 1/2“ O 700.0001 CC1-525w vpc<br />
33 0.7 22 0.4 M16x1 FL Yes Yes 410x480x720 78 230;50 / 400;3~N;50* AIR 5 32 O 692.0011 CC1-705 vpc<br />
33 0.7 22 0.4 M16x1 FL Yes Yes 410x480x720 81 230;50 / 400;3~N;50* AIR 5 32 O 693.0011 CC1-805 vpc<br />
31 0.6 24 0.35 M16x1 FL Yes Yes 540x630x1085 150 400;3~N;50 AIR 5 32 O 567.0021 CC1-820 vpc<br />
31 0.6 24 0.35 M16x1 FL Yes Yes 540x630x1085 150 400;3~N;50 WATER 5 32 1/2“ O 567.0031 CC1-820w vpc<br />
* Voltage can be changed, must be specified with order ** S = Standard, O = Option, R = on Request<br />
www.huber-online.com · Tel. +49-781-96030<br />
Model<br />
51
TECHNICAL DATA<br />
Model<br />
CC1-815 vpc 18 -85...100 1.5 5 120x110x150 0.1 0.02 1 1 1 0.8 0.75 0.6<br />
CC1-905 vpc 18 -90...100 3 26 15 260x260x200 0.1 0.02 2 2 2 1.9 1.7 0.5 0.34<br />
CC1-905w vpc 18 -90...100 3 26 15 260x260x200 0.1 0.02 2 2 2 1.9 1.7 0.5 0.34<br />
DC30 19 -30...50 0.15 0.07<br />
DC31 19 -30...50 0.35 0.1<br />
DC32 19 -30...50 0.47 0.12<br />
TC45 19 45...100 0.24 0.18 0.05<br />
TC45E 19 -45...100 0.1 0.5 0.24 0.18 0.05<br />
TC50 19 -50...50 0.3 0.26<br />
TC50E 19 -50...50 0.1 0.5 0.3 0.26<br />
TC100 19 -100...40 0.15 0.14<br />
TC100E 19 -100...40 0.1 0.5 0.15 0.14<br />
K12 20 -20...200 12 295x320x150 0.18<br />
K15 20 -20...200 15 295x320x200 0.2<br />
K20 20 -30...200 20 295x500x150 0.35 0.21<br />
K25 20 -30...200 25 295x500x200 0.35 0.21<br />
UNISTATS<br />
Catalogue Page<br />
Temperature Range<br />
Tmin with cooling<br />
Heating Power<br />
Tmin with water cooling<br />
Bath Volume<br />
min. Filling Capacity<br />
Bath Volume with<br />
Displacement Insert<br />
Bath Opening WxDxH<br />
Resolution of Display<br />
unistat T326 29 65...300 15 3.0 / 6.0 1.45 0.1 0.02<br />
unistat T326 HT 29 65...300 3.0 / 6.0 1.9 0.1 0.02 3.2 2.3 0.6<br />
unistat T326w HT 29 65...300 15 3.0 / 6.0 1.9 0.1 0.02 10 10 10<br />
unistat T327 29 65...300 15 12 3.5 0.1 0.02<br />
unistat T327w HT 29 65...300 15 12 3.5 0.1 0.02 10 10 6<br />
unistat cc 400-3 29 75...400 3 0.8 0.1 0.05<br />
unistat cc 401-3 29 50...400 3.0 / 9.0 3 0.1 0.05<br />
unistat cc 401w HT-3 29 50...400 3.0 / 9.0 2.3 0.1 0.05 10 10 10<br />
Cooling Power at<br />
unistat tango 31 -40...200 1.5 / 3.0 1.45 0.1 0.02 0.7 0.7 0.7 0.7 0.4 0.05<br />
unistat tango HT 31 -40...300 1.5 / 3.0 1.9 0.1 0.02 3.2 2.3 1.3 0.7 0.7 0.4 0.05<br />
unistat 340 31 -40...200 1.5 / 3.0 1.45 0.1 0.02 1 1 1 1 0.6 0.1<br />
unistat 340w 31 -40...200 1.5 / 3.0 1.45 0.1 0.02 1 1 1 1 0.6 0.1<br />
unistat 340 HT 31 -40...300 1.5 / 3.0 1.9 0.1 0.02 3.2 2.3 1.8 1 1 0.6 0.1<br />
unistat 340w HT 31 -40...300 1.5 / 3.0 1.9 0.1 0.02 3.5 2.3 1.8 1 1 0.6 0.1<br />
unistat 140 31 -40...200 2 3.6 0.1 0.02 2 2 2 2.5 1.8 0.2<br />
unistat 140w 31 -40...200 2 3.6 0.1 0.02 2 2 2 2.5 1.8 0.2<br />
unistat 140w-FB 31 -40...200 2 4.7 0.1 0.02 2 2 2 2.5 1.8 0.2<br />
unistat 140 HT 31 -40...300 2 5 0.1 0.02 3.2 2.3 2.7 2 2.5 1.8 0.2<br />
unistat 140w HT 31 -40...300 2 5 0.1 0.02 3.5 3 2.7 2 2.5 1.8 0.2<br />
unistat 141 31 -40...200 4 3.9 0.1 0.02 3.5 3.5 3.5 3.5 2.2 0.3<br />
unistat 141w 31 -40...200 4 3.9 0.1 0.02 3.5 3.5 3.5 3.5 2.2 0.2<br />
unistat 141w-FB 31 -40...200 4 4.1 0.1 0.02 3.5 3.5 3.5 3.5 2.2 0.2<br />
unistat 141 HT 31 -40...300 4 5 0.1 0.02 3.2 4 3.5 3.5 3.5 2.2 0.3<br />
unistat 141w HT 31 -40...300 4 5 0.1 0.02 3.5 4 3.5 3.5 3.5 2.2 0.2<br />
unistat 150w 31 -50...200 6 4.3 0.1 0.02 5 5 5 2.8 0.9<br />
unistat 150w HT 31 -50...300 6 6.4 0.1 0.02 3.5 6 5.5 5 2.8 0.9<br />
unistat 151w 31 -55...200 6 5.1 0.1 0.02 6 6 6 4.2 1.5<br />
unistat 151w-FB 31 -55...200 6 8.6 0.1 0.02 5 5 6 4.2 1.5<br />
Temperature Stability<br />
300°C<br />
200°C<br />
100°C<br />
20°C<br />
0°C<br />
-20°C<br />
-40°C<br />
-60°C<br />
-80°C<br />
-100°C<br />
°C °C °C kW l l l mm K K kW kW kW kW kW kW kW kW kW kW<br />
unistat 160w 31 -60...200 6 5.65 0.1 0.02 7 7 7 6 3.3 0.8<br />
unistat 161w 31 -60...200 12 5.65 0.1 0.02 9 9 9 7 5 1<br />
unistat 162w 31 -60...200 12 5.2 0.1 0.02 12 12 12 12 7 2<br />
unistat 163w 31 -60...200 12 3.4 0.1 0.02 16 16 16 16 13.5 8.4 2.2<br />
unistat 164w 31 -60...200 24 20 0.1 0.02 22 22 20 18 15 5<br />
unistat 165w 31 -60...200 24 21 0.1 0.02 26 26 25 24 18 6<br />
Models with CC1 controller: Technical Data remains identical with controller change (CC2, CC3) FL = Suitable for inflammable and non-inflammable fluids<br />
52 www.huber-online.com · Tel. +49-781-96030
max. Flow Rate - Pressure Pump<br />
max. Press - Pressure Pump<br />
max. Flow Rate - Suction Pump<br />
max. Press - Suction Pump<br />
Pump Connection<br />
Circulation Pump<br />
Safety Standard<br />
Low Level Protection<br />
Overtemperature Protection<br />
Dimensions WxDxH<br />
TECHNICAL DATA<br />
Power supply<br />
Cooling of refrigeration machine<br />
l/min bar l/min bar mm kg V; Hz °C °C<br />
Weight<br />
min. Ambient Temperature<br />
max. Ambient Temperature<br />
Natural Refrigerant**<br />
Cat.No.<br />
Cooling Water Connection<br />
33 0.7 22 0.4 M16x1 FL Yes Yes 550x600x890 139 230;50 AIR 5 32 O 699.0001 CC1-815 vpc<br />
31 0.6 24 0.35 M16x1 FL Yes Yes 600x700x1130 162 400;3~N;50 AIR 5 32 O 568.0011 CC1-905 vpc<br />
31 0.6 24 0.35 M16x1 FL Yes Yes 600x700x1130 170 400;3~N;50 WATER 5 32 1/2“ O 568.0021 CC1-905w vpc<br />
M16x1 No No 190x250x360 16 230;50 AIR 5 32 O 574.0002 DC30<br />
M16x1 No No 250x310x400 25 230;50/60 AIR 5 32 S 575.0002 DC31<br />
M16x1 No No 280x340x460 30 230;50 AIR 5 32 O 652.0002 DC32<br />
No No 190x250x360 16 230;50 AIR S 570.0008 TC45<br />
No No 190x250x360 16 230;50 AIR S 570.0009 TC45E<br />
No No 250x310x400 25 230;50/60 AIR S 572.0006 TC50<br />
No No 250x310x400 25 230;50/60 AIR S 572.0007 TC50E<br />
No No 280x440x525 55 230;50 AIR O 573.0007 TC100<br />
No No 280x440x525 55 230;50 AIR O 573.0008 TC100E<br />
No No 350x558x215 20 230;50 AIR S 653.0020 K12<br />
No No 350x558x240 19 230;50 AIR S 645.0021 K15<br />
No No 350x558x370 30 230;50/60 AIR S 646.0021 K20<br />
No No 350x558x420 35 230;50/60 AIR S 647.0021 K25<br />
15 0.5 M16x1 FL Yes Yes 425x220x635 35 230;50/60 / 400;3~N;50* 5 32 1/2“ 532.0002 unistat T326<br />
15 0.5 M16x1 FL Yes Yes 425x220x635 36 230;50/60 / 400;3~N;50* 5 32 531.0002 unistat T326 HT<br />
15 0.5 M16x1 FL Yes Yes 425x220x635 42 230;50/60 / 400;3~N;50* 5 32 1/2“ 530.0002 unistat T326w HT<br />
70 1.6 M30x1,5 FL Yes Yes 460x550x1336 90 400;3~N;50 5 32 1/2“ 525.0002 unistat T327<br />
60 1.6 M30x1,5 FL Yes Yes 460x550x1336 124 400;3~N;50 5 32 1/2“ 526.0002 unistat T327w HT<br />
27 0.75 FL Yes Yes 190x240x635 21 230;50/60 5 32 1/2“ 400.0003 unistat cc 400-3<br />
31 1 FL Yes Yes 285x330x735 37 230;50 / 400;3~N;50* 5 40 1/2“ 400.0023 unistat cc 401-3<br />
31 1.0 FL Yes Yes 285x330x735 45 230;50 / 400;3~N;50* 5 40 1/2“ 400.0033 unistat cc 401w HT-3<br />
15 0.5 M16x1 FL Yes Yes 425x270x636 58 230;50/60 / 400;3~N;50* AIR 5 32 O 534.0003 unistat tango<br />
15 0.5 M16x1 FL Yes Yes 425x270x636 59 230;50/60 / 400;3~N;50* AIR 5 32 O 533.0003 unistat tango HT<br />
20 0.7 M16x1 FL Yes Yes 425x300x636 62 230;50/60 / 400;3~N;50* AIR 5 32 O 710.0004 unistat 340<br />
20 0.7 M16x1 FL Yes Yes 425x270x636 55 230;50/60 / 400;3~N;50* WATER 5 32 1/2“ O 710.0003 unistat 340w<br />
15 0.5 M16x1 FL Yes Yes 425x300x636 65 230;50/60 / 400;3~N;50* AIR 5 32 O 711.0003 unistat 340 HT<br />
15 0.5 M16x1 FL Yes Yes 425x300x636 62 230;50/60 / 400;3~N;50* WATER 5 32 1/2“ O 711.0004 unistat 340w HT<br />
100 1.5 M30x1,5 FL Yes Yes 460x550x1336 155 400;3~N;50 AIR 5 32 R 544.0004 unistat 140<br />
100 1.5 M30x1,5 FL Yes Yes 460x550x1336 159 400;3~N;50 WATER 5 32 1/2“ R 545.0004 unistat 140w<br />
100 1.5 M30x1,5 FL Yes Yes 920x635x740 153 400;3~N;50 WATER 5 32 1/2“ R 545.0004FB unistat 140w-FB<br />
60 1.6 M30x1,5 FL Yes Yes 460x550x1336 190 400;3~N;50 AIR 5 32 R 712.0001 unistat 140 HT<br />
60 1.6 M30x1,5 FL Yes Yes 460x550x1336 178 400;3~N;50 WATER 5 32 1/2“ R 712.0002 unistat 140w HT<br />
90 1.5 M30x1,5 FL Yes Yes 460x550x1336 161 400;3~N;50 AIR 5 32 R 550.0005 unistat 141<br />
90 1.5 M30x1,5 FL Yes Yes 460x550x1336 159 400;3~N;50 WATER 5 32 1/2“ R 551.0005 unistat 141w<br />
70 1.6 M30x1,5 FL Yes Yes 920x635x740 153 400;3~N;50 WATER 5 32 1/2“ R 551.0005FB unistat 141w-FB<br />
60 1.6 M30x1,5 FL Yes Yes 460x550x1336 159 400;3~N;50 AIR 5 32 R 713.0003 unistat 141 HT<br />
60 1.6 M30x1,5 FL Yes Yes 460x550x1336 159 400;3~N;50 WATER 5 32 1/2“ R 713.0004 unistat 141w HT<br />
100 1.5 M30x1,5 FL Yes Yes 460x550x1336 163 400;3~N;50 WATER 5 32 1/2“ R 715.0001 unistat 150w<br />
80 1.5 M30x1,5 FL Yes Yes 460x550x1336 180 400;3~N;50 WATER 5 32 1/2“ R 716.0001 unistat 150w HT<br />
60 1.5 M30x1,5 FL Yes Yes 540x600x1336 203 400;3~N;50 WATER 5 32 1/2“ R 717.0001 unistat 151w<br />
60 1.5 M30x1,5 FL Yes Yes 920x635x740 202 400;3~N;50 WATER 5 32 1/2“ R 717.0001FB unistat 151w-FB<br />
50 1.5 M30x1,5 FL Yes Yes 600x700x1515 348 400;3~N;50 WATER 5 32 1/2“ R 552.0005 unistat 160w<br />
50 1.5 M30x1,5 FL Yes Yes 600x700x1515 358 400;3~N;50 WATER 5 32 1/2“ R 556.0005 unistat 161w<br />
90 2.5 M30x1,5 FL Yes Yes 700x800x1515 440 400;3~N;50 WATER 5 32 3/4“ R 557.0005 unistat 162w<br />
90 2.5 M30x1,5 FL Yes Yes 700x800x1515 448 400;3~N;50 WATER 5 32 3/4“ R 559.0004 unistat 163w<br />
110 2.5 M38x1,5 FL Yes Yes 920x1000x1655 740 400;3~N;50 WATER 5 32 3/4“ R 719.0001 unistat 164w<br />
110 2.5 M38x1,5 FL Yes Yes 920x1000x1655 734 400;3~;50 WATER 5 32 3/4“ R 720.0001 unistat 165w<br />
* Voltage can be changed, must be specified with order ** S = Standard, O = Option, R = on Request<br />
www.huber-online.com · Tel. +49-781-96030<br />
Model<br />
53
TECHNICAL DATA<br />
Model<br />
unistat 166w 31 -60...200 30 27.5 0.1 0.02 30 30 30 27 20 6<br />
unistat 167w 31 -60...200 36 30 0.1 0.02 40 40 40 40 22 7<br />
unistat 169w 31 -60...200 48 28 0.1 0.02 65 65 65 65 38 11<br />
unistat 1060w 31 -60...200 96 40 0.1 0.02 130 130 80 60 20<br />
unistat minus 55w-FB-3 31 -55...50 2 16.7 0.1 1 6 6 4.2 1.5<br />
unistat minus 85w-3-FB 31 -85...50 2 3 0.1 1.5 2.3 2.3 2.3 2 1.2 0.2<br />
unistat minus 90w-3 31 -90...50 4 3.8 0.1 1.5 5.2 5.2 5 4.2 2.9 0.75<br />
unistat minus 90w-FB-3 31 -90...50 4 3.8 0.1 1.5 5.2 5.2 5 4.2 2.9 0.75<br />
unistat 360 32 -75...200 1.5 / 3.0 1.45 0.1 0.02 0.6 0.6 0.6 0.6 0.6 0.6 0.3<br />
unistat 360w 32 -75...200 1.5 / 3.0 1.45 0.1 0.02 0.6 0.6 0.6 0.6 0.6 0.6 0.3<br />
unistat 360 HT 32 -75...300 1.5 / 3.0 1.9 0.1 0.02 3.2 2.3 1.4 0.6 0.6 0.6 0.6 0.3<br />
unistat 360w HT 32 -75...300 1.5 / 3.0 1.9 0.1 0.02 3.5 2.3 1.4 0.6 0.6 0.6 0.6 0.3<br />
unistat 380 32 -80...200 2 3.8 0.1 0.02 1.3 1.3 1.3 1.3 1.3 1.3 0.9 0.2<br />
unistat 380w 32 -80...200 2 3.2 0.1 0.02 1.5 1.5 1.5 1.5 1.5 1.5 0.9 0.2<br />
unistat 380 HT 32 -80...300 2 3.8 0.1 0.02 3.2 2.3 1.8 1.3 1.3 1.3 1.3 0.9 0.2<br />
unistat 380w HT 32 -80...300 2 3.8 0.1 0.02 3.5 2.3 1.8 1.5 1.5 1.5 1.5 0.9 0.2<br />
unistat 380w HT-FB 32 -80...300 2 3.8 0.1 0.02 3.5 2.3 1.8 1.5 1.5 1.5 1.5 0.9 0.2<br />
unistat 385 32 -85...200 3 2.9 0.1 0.02 2.3 2.3 2.3 2.3 2.3 2 1.2 0.3<br />
unistat 385w 32 -85...200 3 3 0.1 0.02 2.3 0 2.3 2.3 2.3 2 1.2 0.3<br />
unistat 385w-FB 32 -85...200 3 0.1 0.02 2.3 2.3 2.3 2.3 2.3 2 1.2 0.3<br />
unistat 385 HT 32 -85...300 3 3.8 0.1 0.02 3.2 2.3 2.7 2.3 2.3 2.3 2 1.2 0.3<br />
unistat 385w HT 32 -85...300 3 4.6 0.1 0.02 3.5 2.3 2.7 2.3 2.3 2.3 2 1.2 0.3<br />
unistat 386 32 -85...200 3 3 0.1 0.02 4.0 3.8 3.6 3.5 3.5 3 2 0.6<br />
unistat 386w 32 -85...200 3 3 0.1 0.02 4.0 3.8 3.6 3.5 3.5 3 2 0.6<br />
unistat 390w 32 -90...200 6 4.3 0.1 0.02 5.2 5.2 5.2 5 4.2 3.1 0.9<br />
unistat 390w HT 32 -90...300 6 6.4 0.1 0.02 4.5 2.6 7 5.2 5.2 5 4.2 3.1 0.9<br />
unistat 290w 32 -90...200 12 5.5 0.1 0.02 16 16 16 16 16 15 13.5 3.5<br />
unistat 291w 32 -90...200 24 5.5 0.1 0.02 19 19 19 19 19 17 15 6<br />
unistat 292 32 -90...200 36 11 0.1 0.02 30 30 30 30 30 28 24 10<br />
unistat 292w 32 -90...200 36 11 0.1 0.02 30 30 30 30 30 28 24 10<br />
unistat 420w 33 -120...100 2 3.6 0.1 0.02 1.5 1.5 1.5 1.5 1.5 1.4 1.3 1<br />
unistat 420w HT 33 -120...300 2 5 0.1 0.02 3.5 3.2 3 1.5 1.5 1.5 1.5 1.4 1.3 1<br />
unistat 421w 33 -120...100 4 7 0.1 0.02 2.5 2.5 2.5 2.5 2.5 2.5 2 2<br />
CAL 1 33 -20...150 1 7 0 Ø120 x 400 0.1 0.01 0.3<br />
CAL 2 33 -40...200 1.5 7 7 Ø120 x 400 0.1 0.01 0.5<br />
CAL 3 33 -80...150 1.5 7 7 Ø120 x 400 0.1 0.01 0.3<br />
CAL 4 33 25...250 1.5 7 7 Ø120 x 400 0.1 0.01<br />
UNICHILLERS<br />
Catalogue Page<br />
Temperature Range<br />
Tmin with cooling<br />
Heating Power<br />
Tmin with water cooling<br />
Bath Volume<br />
min. Filling Capacity<br />
Bath Volume with<br />
Displacement Insert<br />
Bath Opening WxDxH<br />
Resolution of Display<br />
minichiller 38 -20...40 1.4 0.1 1 0.2 0.07<br />
minichiller w 38 -20...40 1.4 0.1 1 0.2 0.07<br />
minichiller-1 38 -20...40 1.4 0.1 1 0.2 0.07<br />
minichiller w-1 38 -20...40 2.6 0.1 1 0.2 0.07<br />
UC006A-1 38 -20...40 1.25 0.1 0.5 0.5<br />
UC007 38 -20...40 4.4 0.1 1 0.55 0.16<br />
UC007-1 38 -20...40 4.4 0.1 1 0.55 0.16<br />
UC015-1 38 -10...40 0.9 0.1 0.5 1<br />
UC015w-1 38 -10...40 0.9 0.1 0.5 1<br />
UC022-1 38 -10...40 3.5 0.1 0.5 1.6<br />
UC022w-1 38 -10...40 0.8 0.1 0.5 1.6<br />
UC020-1 38 -10...40 0.8 0.1 0.5 2<br />
UC020w-1 38 -10...40 0.8 0.1 0.5 2<br />
Cooling Power at<br />
Temperature Stability<br />
300°C<br />
200°C<br />
100°C<br />
20°C<br />
0°C<br />
-20°C<br />
-40°C<br />
-60°C<br />
-80°C<br />
-100°C<br />
°C °C °C kW l l l mm K K kW kW kW kW kW kW kW kW kW kW<br />
Models with CC1 controller: Technical Data remains identical with controller change (CC2, CC3) FL = Suitable for inflammable and non-inflammable fluids<br />
54 www.huber-online.com · Tel. +49-781-96030
max. Flow Rate - Pressure Pump<br />
max. Press - Pressure Pump<br />
max. Flow Rate - Suction Pump<br />
max. Press - Suction Pump<br />
Pump Connection<br />
Circulation Pump<br />
Safety Standard<br />
Overtemperature Protection<br />
Low Level Protection<br />
Dimensions WxDxH<br />
TECHNICAL DATA<br />
Power supply<br />
Cooling of refrigeration machine<br />
l/min bar l/min bar mm kg V; Hz °C °C<br />
100 2.5 M38x1,5 FL Yes Yes 920x1200x1655 825 400;3~;50 WATER 5 32 3/4“ R 723.0001 unistat 166w<br />
100 2.5 M38x1,5 FL Yes Yes 1800x1200x1830 1400 400;3~;50 WATER 5 32 1 1/2“ R 724.0001 unistat 167w<br />
100 2.5 M38x1,5 FL Yes Yes 1800x1200x1830 1400 400;3~;50 WATER 5 32 1 1/2“ R 726.0001 unistat 169w<br />
100 2.5 M38x1,5 FL Yes Yes 4500x2000x2000 3500 400;3~N;50 WATER 5 32 2“ R 733.0001 unistat 1060w<br />
55 1.6 M30x1,5 FL Yes Yes 920x635x740 206 400;3~N;50 WATER 5 32 1/2“ R 717.0106 unistat minus 55w FB-3<br />
18 0.7 M30x1,5 FL Yes Yes 1200x650x745 277 400;3~N;50 WATER 5 32 1/2“ R 549.0105 unistat minus 85w-3-FB<br />
40 1.5 M30x1,5 FL Yes Yes 600x700x1550 392 400;3~N;50 WATER 5 32 1/2“ R 554.0112 unistat minus 90w-3<br />
40 1.5 M30x1,5 FL Yes Yes 1500x700x900 399 400;3~N;50 WATER 5 30 1/2“ R 554.0109 unistat minus 90w-FB-3<br />
25 0.8 M16x1 FL Yes Yes 425x400x720 88 230;50 / 400;3~N;50* AIR 5 32 O 536.0006 unistat 360<br />
25 0.8 M16x1 FL Yes Yes 425x400x720 87 230;50 / 400;3~N;50* WATER 5 32 1/2“ O 536.0005 unistat 360w<br />
16 0.8 M16x1 FL Yes Yes 425x400x720 91 230;50 / 400;3~N;50* AIR 5 32 O 535.0006 unistat 360 HT<br />
16 0.8 M16x1 FL Yes Yes 425x400x720 91 230;50 / 400;3~N;50* WATER 5 32 1/2“ O 535.0005 unistat 360w HT<br />
35 0.8 M30x1,5 FL Yes Yes 460x600x1346 186 400;3~N;50 AIR 5 32 R 539.0006 unistat 380<br />
35 0.8 M30x1,5 FL Yes Yes 460x600x1346 190 400;3~N;50 WATER 5 32 1/2“ R 540.0006 unistat 380w<br />
30 0.8 M30x1,5 FL Yes Yes 460x600x1346 190 400;3~N;50 AIR 5 32 R 537.0006 unistat 380 HT<br />
30 0.8 M30x1,5 FL Yes Yes 460x600x1346 190 400;3~N;50 WATER 5 32 1/2“ R 538.0006 unistat 380w HT<br />
30 0.8 M30x1,5 FL Yes Yes 1200x650x740 190 400;3~N;50 WATER 5 32 1/2“ R 538.0006FB unistat 380w HT-FB<br />
30 0.8 M30x1,5 FL Yes Yes 460x600x1346 208 400;3~N;50 AIR 5 32 R 548.0006 unistat 385<br />
30 0.8 M30x1,5 FL Yes Yes 460x600x1346 204 400;3~N;50 WATER 5 32 1/2“ R 549.0006 unistat 385w<br />
30 0.8 M30x1,5 FL Yes Yes 1200x650x740 234 400;3~N;50 WATER 5 30 1/2“ R 549.0005FB unistat 385w-FB<br />
30 0.8 M30x1,5 FL Yes Yes 460x600x1346 212 400;3~N;50 AIR 5 32 R 546.0006 unistat 385 HT<br />
30 0.8 M30x1,5 FL Yes Yes 460x600x1346 212 400;3~N;50 WATER 5 32 1/2“ R 547.0006 unistat 385w HT<br />
32 0.8 M30x1,5 FL Yes Yes 540x650x1490 245 400;3~N;50 AIR 5 32 R 721.0002 unistat 386<br />
32 0.8 M30x1,5 FL Yes Yes 540x650x1490 238 400;3~N;50 WATER 5 32 1/2“ R 722.0002 unistat 386w<br />
40 1.5 M30x1,5 FL Yes Yes 600x700x1560 390 400;3~N;50 WATER 5 32 1/2“ R 554.0005 unistat 390w<br />
35 1.5 M30x1,5 FL Yes Yes 600x700x1560 424 400;3~N;50 WATER 5 32 1/2“ R 553.0005 unistat 390w HT<br />
57 1.3 M38x1,5 FL Yes Yes 920x1200x1655 995 400;3~;50 WATER 5 32 3/4“ R 558.0003 unistat 290w<br />
80 2.5 M38x1,5 FL Yes Yes 920x1200x1655 991 400;3~;50 WATER 5 32 3/4“ R 705.0001 unistat 291w<br />
100 2.5 1 1/4“ FL Yes Yes 1700x3500x1850 2100 400;3~;50 AIR 5 32 R 706.0001 unistat 292<br />
100 2.5 1 1/4“ FL Yes Yes 2400x1200x1750 1950 400;3~;50 WATER 5 32 1“ R 706.0002 unistat 292w<br />
18 0.7 M16x1 FL Yes Yes 700x800x1515 355 400;3~;50 WATER 5 32 1/2“ R 543.0004 unistat 420w<br />
16 0.7 M16x1 FL Yes Yes 700x800x1515 390 400;3~;50 WATER 5 32 1/2“ R 541.0004 unistat 420w HT<br />
44 1.5 M30x1,5 FL Yes Yes 920x1200x1655 685 400;3~;50 WATER 5 32 1/2“ R 707.0001 unistat 421w<br />
FL Yes Yes 585x425x550 73 230;50 AIR 5 32 R 665.0004 CAL 1<br />
FL Yes Yes 585x425x550 71 230;50 AIR 5 32 R 665.0005 CAL 2<br />
FL Yes Yes 585x560x550 128 230;50 AIR 5 32 R 665.0003 CAL 3<br />
FL Yes Yes 585x355x550 49 230;50 5 32 665.0006 CAL 4<br />
12 0.2 0.1 M16x1 Yes No No 225x360x380 23 230;50/60 AIR 5 32 R 466.0010 minichiller<br />
12 0.2 0.1 M16x1 Yes No No 225x360x380 23 230;50 WATER 5 32 1/2“ R 466.0020 minichiller w<br />
12 0.2 0.1 M16x1 Yes NFL No No 225x360x380 23 230;50/60 AIR 5 32 O 466.0011 minichiller-1<br />
12 0.2 0.1 M16x1 Yes NFL No No 225x360x380 23 230;50 WATER 5 32 1/2“ O 466.0021 minichiller w-1<br />
18 0.5 M16x1 A NFL No Yes 277x500x425 37 230;50 AIR 5 32 O 576.0031 UC006A-1<br />
22 3.0 M16x1 B No No 320x500x493 41 230;50 AIR 5 32 O 576.0050 UC007<br />
Weight<br />
min. Ambient Temperature<br />
max. Ambient Temperature<br />
Natural Refrigerant**<br />
Cat.No.<br />
Cooling Water Connection<br />
22 3.0 M16x1 B NFL No Yes 320x500x493 41 230;50 AIR 5 32 O 576.0051 UC007-1<br />
25 3.0 M16x1 B NFL No Yes 410x480x540 52 230;50 AIR 5 32 O 677.0021 UC015-1<br />
25 3.0 M16x1 B NFL No Yes 410x480x540 53 230;50 WATER 5 32 1/2“ O 677.0031 UC015w-1<br />
25 3.0 3/4“ B NFL No Yes 460x510x755 78 400;3~N;50 AIR 5 32 O 670.0031 UC022-1<br />
25 3.0 3/4“ B NFL No Yes 460x510x755 93 400;3~N;50 WATER 5 32 1/2“ O 670.0041 UC022w-1<br />
25 3.0 3/4“ B NFL No Yes 460x510x755 76 400;3~N;50 AIR 5 32 O 672.0031 UC020-1<br />
25 3.0 3/4“ B NFL No Yes 460x510x755 73 400;3~N;50 WATER 5 32 1/2“ O 672.0041 UC020w-1<br />
* Voltage can be changed, must be specified with order ** S = Standard, O = Option, R = on Request<br />
www.huber-online.com · Tel. +49-781-96030<br />
Model<br />
55
TECHNICAL DATA<br />
Model<br />
Catalogue Page<br />
Temperature Range<br />
Tmin with cooling<br />
Heating Power<br />
Tmin with water cooling<br />
Bath Volume<br />
min. Filling Capacity<br />
Bath Volume with<br />
Displacement Insert<br />
Bath Opening WxDxH<br />
Resolution of Display<br />
UC025-1 38 -10...40 0,8 0.1 0.5 2<br />
UC025w-1 38 -10...40 0.8 0.1 0.5 2<br />
UC006T-1 40 -25...40 1.25 0.1 0.5 0.45 0.07<br />
UC009T-1 40 -25...40 1.25 0.1 0.5 0.7 0.25<br />
UC012T-1 40 -25...40 1.25 0.1 0.5 1 0.4<br />
UC016T-1 40 -10...40 2.5 0.1 0.5 0.9<br />
UC020T-1 40 -20...40 2.5 0.1 0.5 2 0.5<br />
UC025T-1 40 -10...40 2.5 0.1 0.5 1.2<br />
UC040T-1 40 -10...40 2.1 0.1 0.5 2.2<br />
UC045T-1 40 -20...40 2 0.1 0.5 4.3 1.5<br />
UC055T-1 40 -10...40 5 0.1 0.5 3<br />
UC060T-1 40 -20...40 5 0.1 0.5 6 1.5<br />
UC080T-1 40 -10...40 5 0.1 0.5 4.8<br />
UC100T-4 40 -20...40 8.36 0.1 0.5 10 2.5<br />
UC110T-4 40 -10...40 8.36 0.1 0.5 6<br />
UC130T-4 40 -10...40 8.36 0.1 0.5 7.2<br />
UC150T-4 40 -20...40 17 0.1 0.5 15 3.7<br />
UC160T-4 40 -10...40 17 0.1 0.5 8.8<br />
UC200T-4 40 -10...40 17 0.1 0.5 11<br />
UC210T-4 40 -20...40 17 0.1 0.5 21 5.2<br />
UC250T-4 40 -10...40 20 0.1 0.5 14<br />
UC260T-4 40 -20...40 20 0.1 0.5 26 5.2<br />
UC300T-4 40 -10...40 25 0.1 0.5 16.5<br />
UC400T-4 40 -10...40 25 0.1 0.5 22<br />
UC006Tw-1 41 -20...40 1.25 0.1 0.5 0.45 0.25<br />
UC009Tw-1 41 -25...40 1.25 0.1 0.5 0.7 0.2<br />
UC012Tw-1 41 -25...40 1.25 0.1 0.5 1 0.3<br />
UC015Tw-1 41 -25...40 1.55 0.1 0.5 1.2 0.4<br />
UC023Tw-1 41 -25...40 1.55 0.1 0.5 1.6 0.5<br />
UC016Tw-1 41 -10...40 2.5 0.1 0.5 0.9<br />
UC020Tw-1 41 -20...40 2.5 0.1 0.5 2 0.5<br />
UC025Tw-1 41 -10...40 2.5 0.1 0.5 1.2 0.1<br />
UC030Tw-1 41 -20...40 2.5 0.1 0.5 3 1<br />
UC040Tw-1 41 -10...40 2.5 0.1 0.5 2.1<br />
UC055Tw-1 41 -10...40 5.9 0.1 0.5 4<br />
UC060Tw-1 41 -20...40 5.9 0.1 0.5 6 1.4<br />
UC080Tw-1 41 -10...40 5.9 0.1 0.5 4.65<br />
UC100Tw-4 41 -20...40 6.5 0.1 0.5 10 3<br />
UC110Tw-4 41 -10...40 6.5 0.1 0.5 5.8<br />
UC130Tw-4 41 -10...40 6.5 0.1 0.5 7<br />
UC150Tw-4 41 -20...40 11 0.1 0.5 15 5<br />
UC160Tw-4 41 -10...40 11 0.1 0.5 9.5<br />
UC200Tw-4 41 -10...40 11 0.1 0.5 10.7<br />
UC210Tw-4 41 -20...40 12.3 0.1 0.5 21 10<br />
UC250Tw-4 41 -10...40 12.3 0.1 0.5 13.6<br />
UC260Tw-4 41 -20...40 12.3 0.1 0.5 26 12<br />
UC300Tw-4 41 -10...40 12.3 0.1 0.5 16<br />
UC400Tw-4 41 -10...40 18 0.1 0.5 21<br />
UC500Tw-4 41 -10...40 25 0.1 0.5 26<br />
Unichiller ETH-1 wl 42 -10...40 5.2 0.1 0.5 2<br />
Rotacool 42 -20...40 1.5 0.1 1 0.3<br />
Cooling Power at<br />
Temperature Stability<br />
300°C<br />
200°C<br />
100°C<br />
20°C<br />
0°C<br />
-20°C<br />
-40°C<br />
-60°C<br />
-80°C<br />
-100°C<br />
°C °C °C kW l l l mm K K kW kW kW kW kW kW kW kW kW kW<br />
Models with CC1 controller: Technical Data remains identical with controller change (CC2, CC3) FL = Suitable for inflammable and non-inflammable fluids<br />
56 www.huber-online.com · Tel. +49-781-96030
max. Flow Rate - Pressure Pump<br />
max. Press - Pressure Pump<br />
max. Flow Rate - Suction Pump<br />
max. Press - Suction Pump<br />
Pump Connection<br />
Circulation Pump<br />
Safety Standard<br />
Low Level Protection<br />
Overtemperature Protection<br />
Dimensions WxDxH<br />
TECHNICAL DATA<br />
Power supply<br />
Cooling of refrigeration machine<br />
l/min bar l/min bar mm kg V; Hz °C °C<br />
Weight<br />
min. Ambient Temperature<br />
max. Ambient Temperature<br />
Natural Refrigerant**<br />
Cat.No.<br />
Cooling Water Connection<br />
25 3.0 3/4“ B NFL No Yes 460x615x755 88 400;3~N;50 AIR 5 32 O 674.0041 UC025-1<br />
26.5 3.5 3/4“ B NFL No Yes 460x510x755 88 400;3~N;50 WATER 5 32 1/2“ O 674.0051 UC025w-1<br />
30 0.7 M16x1 A NFL No No 350x310x615 40 230;50 AIR 5 32 O 582.0011 UC006T-1<br />
30 0.7 M16x1 A NFL No No 350x310x615 41 230;50 AIR 5 32 O 584.0011 UC009T-1<br />
30 0.7 M16x1 A NFL No No 350x310x615 44 230;50 AIR 5 32 O 586.0011 UC012T-1<br />
22 3.0 1 1/4“ B NFL No Yes 450x510x1160 114 230;50 AIR 5 32 O 587.0011 UC016T-1<br />
22 3.0 3/4“ B NFL No Yes 450x510x1160 130 230;50 AIR 5 32 O 588.0011 UC020T-1<br />
22 3.0 3/4“ B NFL No Yes 450x510x1160 119 230;50 AIR 5 32 O 589.0011 UC025T-1<br />
22 3.0 3/4“ B NFL No Yes 500x550x1265 110 400;3~N;50 AIR 5 32 O 590.0011 UC040T-1<br />
22 3.0 3/4“ B NFL No Yes 500x550x1265 164 400;3~N;50 AIR 5 32 O 591.0011 UC045T-1<br />
65 4.0 1 1/4“ C3 NFL No Yes 600x630x1600 175 400;3~N;50 AIR 5 32 O 592.0011 UC055T-1<br />
65 4.0 1 1/4“ C3 NFL No Yes 600x630x1570 199 400;3~N;50 AIR 5 32 O 593.0011 UC060T-1<br />
65 4.0 1 1/4“ C3 NFL No Yes 600x730x1570 223 400;3~N;50 AIR 5 32 O 594.0011 UC080T-1<br />
65 4.0 1 1/4“ C3 NFL No Yes 600x790x1570 230 400;3~N;50 AIR 5 32 O 595.0006 UC100T-4<br />
65 4.0 1 1/4“ C3 NFL No Yes 600x790x1570 230 400;3~N;50 AIR 5 32 R 596.0006 UC110T-4<br />
65 4.0 1 1/4“ C3 NFL No Yes 874x1185x1870 480 400;3~N;50 AIR 5 32 R 597.0006 UC130T-4<br />
140 4.0 1 1/4“ D3 NFL No Yes 874x1485x1870 480 400;3~N;50 AIR 5 32 R 598.0005 UC150T-4<br />
140 4.0 1 1/4“ D3 NFL No Yes 874x1185x1870 235 400;3~N;50 AIR 5 32 R 600.0005 UC160T-4<br />
140 4.0 1 1/4“ D3 NFL No Yes 874x1465x1870 480 400;3~N;50 AIR 5 32 R 601.0005 UC200T-4<br />
140 4.0 1 1/4“ D3 NFL No Yes 874x1985x1870 430 400;3~N;50 AIR 5 32 R 602.0005 UC210T-4<br />
140 4.0 1 1/4“ D3 NFL No Yes 874x1985x1870 430 400;3~N;50 AIR 5 32 R 603.0005 UC250T-4<br />
140 4.0 1 1/4“ D3 NFL No Yes 874x1985x1870 430 400;3~N;50 AIR 5 32 R 604.0005 UC260T-4<br />
140 4.0 1 1/4“ D3 NFL No Yes 874x1985x1870 450 400;3~N;50 AIR 5 32 R 605.0005 UC300T-4<br />
140 4.0 1 1/4“ D3 NFL No Yes 2500x1685x1800 480 400;3~N;50 AIR 5 32 R 650.0005 UC400T-4<br />
30 0.7 M16x1 A NFL No Yes 230x280x550 30 230;50 WATER 5 40 1/2“ O 606.0031 UC006Tw-1<br />
30 0.7 M16x1 A NFL No Yes 230x280x550 32 230;50 WATER 5 40 1/2“ O 607.0031 UC009Tw-1<br />
30 0.7 M16x1 A NFL No Yes 350x310x615 40 230;50 WATER 5 40 1/2“ O 611.0011 UC012Tw-1<br />
30 0.7 M16x1 A NFL No Yes 350x310x615 43 230;50 WATER 5 40 1/2“ O 613.0011 UC015Tw-1<br />
30 0.7 M16x1 A NFL No Yes 350x310x615 50 230;50 WATER 5 40 1/2“ O 615.0011 UC023Tw-1<br />
22 3.0 3/4“ B NFL No Yes 400x440x1100 96 230;50 WATER 5 40 1/2“ O 616.0011 UC016Tw-1<br />
22 3.0 3/4“ B NFL No Yes 400x440x1100 109 230;50 WATER 5 40 1/2“ O 617.0011 UC020Tw-1<br />
22 3.0 3/4“ B NFL No Yes 400x440x1100 97 230;50 WATER 5 40 1/2“ O 618.0011 UC025Tw-1<br />
22 3.0 3/4“ B NFL No Yes 400x440x1100 115 400;3~N;50 WATER 5 40 1/2“ O 619.0011 UC030Tw-1<br />
22 3.0 3/4“ B NFL No Yes 400x440x1100 110 400;3~N;50 WATER 5 40 1/2“ O 620.0011 UC040Tw-1<br />
65 4.0 1 1/4“ C3 NFL No Yes 500x550x1265 168 400;3~N;50 WATER 5 40 1/2“ O 621.0011 UC055Tw-1<br />
65 4.0 1 1/4“ C3 NFL No Yes 500x550x1265 173 400;3~N;50 WATER 5 40 1/2“ O 622.0011 UC060Tw-1<br />
65 4.0 1 1/4“ C3 NFL No Yes 500x550x1265 225 400;3~N;50 WATER 5 40 1/2“ O 623.0011 UC080Tw-1<br />
90 5.5 1 1/4“ C3 NFL No Yes 600x600x1450 230 400;3~N;50 WATER 5 40 1/2“ O 624.0005 UC100Tw-4<br />
65 4.0 1 1/4“ C3 NFL No Yes 600x600x1450 230 400;3~N;50 WATER 5 40 1/2“ R 625.0005 UC110Tw-4<br />
65 4.0 1 1/4“ C3 NFL No Yes 600x600x1450 370 400;3~N;50 WATER 5 40 1/2“ R 626.0005 UC130Tw-4<br />
140 4.0 1 1/4“ D3 NFL No Yes 760x800x1560 370 400;3~N;50 WATER 5 40 1/2“ R 627.0005 UC150Tw-4<br />
140 4.0 1 1/4“ D3 NFL No Yes 600x600x1450 235 400;3~N;50 WATER 5 40 1/2“ R 628.0005 UC160Tw-4<br />
140 4.0 1 1/4“ D3 NFL No Yes 760x800x1560 430 400;3~N;50 WATER 5 40 3/4“ R 629.0005 UC200Tw-4<br />
140 4.0 1 1/4“ D3 NFL No Yes 760x800x1560 430 400;3~N;50 WATER 5 40 1/2“ R 630.0007 UC210Tw-4<br />
140 4.0 1 1/4“ D3 NFL No Yes 760x800x1560 430 400;3~N;50 WATER 5 40 3/4“ R 631.0005 UC250Tw-4<br />
140 4.0 1 1/4“ D3 NFL No Yes 760x800x1560 430 400;3~N;50 WATER 5 40 3/4“ R 632.0005 UC260Tw-4<br />
140 4.0 1 1/4“ D3 NFL No Yes 760x800x1560 450 400;3~N;50 WATER 5 40 3/4“ R 633.0005 UC300Tw-4<br />
140 4.0 1 1/4“ D3 NFL No Yes 1000x920x1665 480 400;3~N;50 WATER 5 40 3/4“ R 634.0005 UC400Tw-4<br />
140 4.0 1 1/4“ D3 NFL No Yes 1000x920x1665 520 400;3~N;50 WATER 5 40 1/2“ R 635.0005 UC500Tw-4<br />
30 1.4 3/4“ Yes NFL No Yes 460x615x760 93 400;3~N;50 AIR+WATER 5 32 1/2“ R 673.0011 Unichiller ETH-1 wl<br />
10 0.2 M16x1 Yes No Yes 470x580x420 32 230;50/60 AIR 5 32 O 659.0001 Rotacool<br />
* Voltage can be changed, must be specified with order ** S = Standard, O = Option, R = on Request<br />
www.huber-online.com · Tel. +49-781-96030<br />
Model<br />
57
TECHNICAL DATA<br />
Model<br />
SPECIALS<br />
Catalogue Page<br />
Temperature Range<br />
Tmin with cooling<br />
Tmin with water cooling<br />
Heating Power<br />
Bath Volume<br />
min. Filling Capacity<br />
Bath Volume with<br />
Displacement Insert<br />
Bath Opening WxDxH<br />
°C °C °C kW l l l mm K K kW kW kW kW kW kW kW kW kW kW<br />
Hotbox HB1-1 44 45...250 4.5 3.5 0.1<br />
Hotbox HB2-1 44 60...250 6 3.5 0.1<br />
Hotbox HB3-1 44 60...250 6 3.5 0.1<br />
Hotbox HB4-1 44 25...250 12 3.5 0.1<br />
Hotbox HB5-1 44 25...250 12 3.5 0.1<br />
Resolution of Display<br />
BFT1-2 44 0...80 2 22 8.5 280x280x150 0.1 0.02 1<br />
BFT1w-2 44 0...80 2 22 280x280x150 0.1 0.02 1<br />
BFT2-2 44 0...80 3 90 530x400x360 0.1 0.02 2.5<br />
BFT2w-2 44 0...80 3 90 530x400x360 0.1 0.02 2.5<br />
Cooling Power at<br />
Temperature Stability<br />
300°C<br />
200°C<br />
100°C<br />
20°C<br />
0°C<br />
-20°C<br />
-40°C<br />
-60°C<br />
-80°C<br />
-100°C<br />
Models with CC1 controller: Technical Data remains identical with controller change (CC2, CC3) FL = Suitable for inflammable and non-inflammable fluids<br />
58 www.huber-online.com · Tel. +49-781-96030
max. Flow Rate - Pressure Pump<br />
max. Press - Pressure Pump<br />
max. Flow Rate - Suction Pump<br />
max. Press - Suction Pump<br />
Pump Connection<br />
Circulation Pump<br />
Safety Standard<br />
Overtemperature Protection<br />
Low Level Protection<br />
Dimensions WxDxH<br />
l/min bar l/min bar mm kg V; Hz °C °C °C<br />
TECHNICAL DATA<br />
Weight<br />
Power supply<br />
min. Ambient Temperature<br />
Cooling of refrigeration machine<br />
max. Ambient Temperature<br />
Cooling Water Connection<br />
Natural Refrigerant**<br />
Cat.No.<br />
M16x1 FL Yes Yes 180x430x360 19 400;3~N;50 5 32 290.0051 Hotbox HB1-1<br />
M16x1 FL Yes Yes 455x320x500 50 400;3~N;50 5 32 290.0061 Hotbox HB2-1<br />
80 1.6 M30x1,5 FL Yes Yes 455x320x500 44 400;3~N;50 5 32 290.0071 Hotbox HB3-1<br />
M30x1,5 FL Yes Yes 455x320x500 44 400;3~N;50 5 32 290.0081 Hotbox HB4-1<br />
M30x1,5 FL Yes Yes 455x320x500 50 400;3~N;50 5 32 290.0091 Hotbox HB5-1<br />
FL Yes Yes 420x590x700 70 230;50 AIR 5 32 O 569.0005 BFT1-2<br />
FL Yes Yes 420x590x700 70 230;50 WATER 5 32 1/2“ O 569.0006 BFT1w-2<br />
FL Yes Yes 670x720x1070 116 400;3~N;50 AIR 5 32 O 249.0005 BFT2-2<br />
FL Yes Yes 670x720x1070 116 400;3~N;50 WATER 5 32 1/2“ O 249.0006 BFT2w-2<br />
* Voltage can be changed, must be specified with order ** S = Standard, O = Option, R = on Request<br />
www.huber-online.com · Tel. +49-781-96030<br />
Model<br />
59
GLOSSARY<br />
AAmbient Temperature<br />
Range<br />
Ambient Temperature Range is the permissible<br />
temperature range of the environment<br />
in which the unit will function. lt is 5...32°C<br />
for all Huber units in this catalogue. The<br />
quoted cooling powers are for an ambient<br />
temperature of 20°C.<br />
Automatic<br />
Compressor Control<br />
Is a procedure used in refrigeration machines<br />
to save energy. A microprocessor<br />
control decides if the refrigeration machine<br />
is required or if it can be switched off.<br />
Automatic Cooling Capacity<br />
Control<br />
is a control routine to save energy. The microprocessor<br />
based controller determines<br />
whether it is possible to reduce the cooling<br />
power. In addition to saving energy, this<br />
also saves wear and tear of the compressor,<br />
reduces the amount of heat discharged<br />
into the environment, and gives better temperature<br />
control.<br />
CCalibration<br />
Thermostat (CAL)<br />
is a bath thermostat with especially <strong>high</strong><br />
temperature stability and especially consistent<br />
temperature distribution through<br />
the bath.<br />
DDischarge Pressure<br />
is the positive pressure of the circulating<br />
pump of a thermostat directly at the pump<br />
discharge. lf only one value is given in the<br />
tables, then this involves the maximum<br />
B<br />
delivery pressure for flow rate zero. Pump<br />
Bath/Circulation<br />
curves illustrate discharge in relation to the<br />
Thermostat<br />
flow rate.<br />
is a thermostat with a bath opening which<br />
is allows objects to be directly thermoregu-<br />
E<br />
lated in the bath as well as a pump (Com- Extended Working<br />
patible Control thermostats have pressure Temperature Range<br />
and suction pump) for closed (pressure Extended Working Temperature Range is<br />
pump) and open (suction and pressure the temperature range that can be attained<br />
pumps) external circuits.<br />
when using a factory-fitted cooling coil<br />
when operating with cooling water.<br />
Bath Opening<br />
is the usable surface that is available for<br />
direct <strong>thermoregulation</strong>, as a rule over the<br />
entire usable depth.<br />
Bath Thermostat<br />
is a thermostat which is equipped with a<br />
pump and a bath that contains the object<br />
to be thermoregulated. The built-in circulating<br />
pump is used to mix the bath liquid,<br />
but can also be used if necessary to circulate<br />
the thermofluid through an externally<br />
connected circuit, e.g. connection of<br />
a through-flow cooler to allow the cooling<br />
of heating thermostats.<br />
Bath Volume<br />
(also fill volume)<br />
is the volume of the bath liquid that is<br />
required for adequate operation of the<br />
thermostat, but without considering the<br />
volume of thermofluid in the external circuit.<br />
lf two values are given, the lower<br />
value indicates the minimum required vol-<br />
60 www.huber-online.com · Tel. +49-781-96030<br />
ume with displacement insert, the upper<br />
value the permissible maximum amount.<br />
The difference is the so-called expansion<br />
volume. Especially in the case of external<br />
applications, the size of the expansion tank<br />
must be considered, since the circulating<br />
thermostat must also take up the expansion<br />
of the liquid in the external circuit. The<br />
smaller the surface area of the expansion<br />
tank the lower is the area of thermofluid<br />
open to attack from oxidation and air humidity<br />
absorption.<br />
Clear-view Thermostat<br />
is a bath thermostat with transparent walls<br />
for direct observation of the object being<br />
thermoregulated.<br />
FFlow Rate<br />
is the volume of liquid delivered per time<br />
unit by the circulating pump measured with<br />
water. If only one value is given in the table,<br />
this is the maximum flow rate for a zero<br />
discharge pressure. Pump curves illustrate<br />
discharge in relation to the flow rate.<br />
HHeat Load<br />
is the maximum capacity of the installed<br />
N<br />
electric heater. The heating is controlled Net Cooling Capacity<br />
proportionally. The heating is continually is the effective capacity available in refrig-<br />
controlled, and as the set point temperaeration thermostats or circulating chillers.<br />
ture is approached the power is reduced This is the net cooling power of the unit<br />
automatically.<br />
after the frictional heat produced by the<br />
circulating pump and the heat entering as<br />
a result of non-ideal insulation has been<br />
subtracted.<br />
Heating Thermostat<br />
is a thermostat whose working temperature<br />
range is primarily above the ambient<br />
temperature adds heat to the thermofluid.<br />
I O<br />
lmmersion Cooler<br />
is an additional chiller with a flexible tube<br />
and a cooling coil (evaporator) for immersion<br />
cooling of any desired bath.<br />
lmmersion Thermostat<br />
is a thermostat that can be combined with<br />
a bath and to form a complete unit. Immersion<br />
thermostats are equipped with a screw<br />
clamp to attach them to any desired bath<br />
wall or can be fixed on a stand. Immersion<br />
thermostats can also be fitted to a bridge<br />
and mounted permanently in a bath.<br />
Industrial Thermostats<br />
(UC-Hx)<br />
are refrigerated circulators (Unichiller<br />
range) with factory fitted heating. The<br />
units have <strong>high</strong> cooling, heating and<br />
pump powers which allow quick cooling<br />
and heating rates due to the small<br />
internal volumes. They are ideal for<br />
temperature control in process technology,<br />
within a smaller temperature range<br />
(-20..120°C).<br />
Interface, analogue<br />
is used to input the set value or to output<br />
the actual value of temperature in analogue<br />
form, generally in the form of a current<br />
(4...20 mA).<br />
Interface, digital<br />
is used to transfer data between connected<br />
units in digital form via data cable. The set<br />
and actual temperature values are the main<br />
items transferred. The serial RS 232 interface<br />
allows a point-to-point connection.<br />
This means that at anyone time only two<br />
participants such as the thermostat and the<br />
PC can communicate with each other via<br />
the interface. The RS 485 interface is an<br />
addressable interface where up to 32 participants<br />
can be connected. Each participant<br />
of the bus system has its address.<br />
Intrinsic Temperature<br />
is the operating temperature of a heating<br />
thermostat that is reached when the heating<br />
is switched off. lt depends on the pump<br />
power, thermofluid (viscosity and density)<br />
used and the insulation of the thermostat,<br />
e.g. with or without a cover on the bath.<br />
Operating Temperature<br />
Range<br />
Operating Temperature Range is the temperature<br />
range that is limited by the permissible<br />
lowest and <strong>high</strong>est operating<br />
temperatures.
P<br />
Pressure Pump<br />
is used for circulation of the thermofluid in<br />
an external closed circuit and in the bath.<br />
Pressure/Suction Pump<br />
This pump has a pressure and a suction<br />
stage which are driven by the same motor.<br />
The thermofluid is delivered from the<br />
pressure stage from the thermostat into<br />
the circuit, and the suction stage draws<br />
the liquid back into the thermostat. A pressure/suction<br />
pump can be used in just the<br />
same way as a pressure pump for a closed<br />
circuit. lt has the advantage compared to<br />
a pressure pump that the pressure in the<br />
external circuit falls from positive values<br />
(pressure) in the flow line and to negative<br />
values (suction) in the return line and is almost<br />
zero in the application itself. Thus it is<br />
suitable for the <strong>thermoregulation</strong> of pressure-sensitive<br />
glass vessels. Additionally<br />
it is possible to thermoregulate an open<br />
external circuit (e.g. a bath) with the aid of<br />
a pressure/suction pump. This cannot be<br />
done with a pure pressure pump, since this<br />
delivers thermofluid to the bath. The thermofluid<br />
can only be returned to the bath<br />
via a suction stage. In any case a so-called<br />
constant Ievel device is required to maintain<br />
a constant level in the bath and this<br />
ensures that the flows of both pump stages<br />
are controlled so that they are equal. This<br />
is the only way that the Ievel in the external<br />
bath can be maintained constant.<br />
TTemperature Constance<br />
is half of the temperature difference between<br />
the <strong>high</strong>est and bowest temperatures<br />
which are measured for a specific set<br />
point after attaining a stable value over a<br />
30 minute period. The details are quoted for<br />
70°C (using water) for a heating thermostat<br />
and at -10°C (using ethanol) for a cooling<br />
thermostat (see also DIN 12876).<br />
WWorking Temperature<br />
Range<br />
Working Temperature Range is the temperature<br />
range which can be attained at an<br />
ambient temperature of 20°C by the thermostat<br />
alone and with the exclusive use of<br />
electrical energy. In the case of a heating<br />
thermostat the working temperature begins<br />
above room temperature (as a result<br />
of the energy introduced by the pump and<br />
the effective insulation) and ends at the upper<br />
limit of the operating temperature. The<br />
WTR of a refrigeration thermostat begins<br />
with the lowest operating temperature of<br />
the unit and finishes with the upper temperature<br />
at which the refrigeration machine<br />
can permanently operate.<br />
SSafety Classes<br />
lt is possible to use non-flammable or flammable<br />
bath liquids with thermostats. The<br />
relevant safety requirements are given in<br />
DIN EN 61010-2-010. There is a distinction<br />
made between the NFL classes with built-in<br />
over-heating protection that are exclusively<br />
for non-flammable liquids and FL (Flammable)<br />
with adjustable overtemperature<br />
protection and bw level protection for flam-<br />
RRecirculation Thermostat mable liquids (all Huber thermostats).<br />
(Unistats)<br />
Is a thermostat in which thermofluid is<br />
pumped through an open or closed external<br />
circuit. Recirculation thermostats e.g.<br />
the Unistats can have a thermally discoupled<br />
expansion vessel, whose surface temperature<br />
is not the operating temperature.<br />
They do not have an accessible bath. Unistats<br />
have a thermally discoupled active<br />
surface (expansion vessel), where by the<br />
surface temperature is not necessarily the<br />
same as the operating temperature.<br />
Process Control<br />
Often cascade control, is when the temperature<br />
control is dictated by the temperature<br />
of the connected external application.<br />
A temperature sensor (often a Pt100 4 wire<br />
configuration with a Lemosa plug) is therefore<br />
required in the external application,<br />
which is connected to the thermostat. The<br />
actual value measured at the external application<br />
is measured and a set point for<br />
the thermostat is continually calculated.<br />
Depending on the operating temperature,<br />
insulation losses and exothermic reactions,<br />
the bath temperature and thus the<br />
flow temperature of the thermostat can be<br />
considerably above or below the set point.<br />
(Always consider the safety limits of the<br />
fluid!!)<br />
Refrigerated Circulator<br />
is a special cooling thermostat which is designed<br />
exclusively as a circulation thermostat.<br />
Circulation chillers have evolved from<br />
thermostats and form a separate range of<br />
units in terms of their type of construction<br />
(DeskTop, Tower), the cooling and pump<br />
capacities. Generally they have no accessible<br />
bath. They are often used as a substitute<br />
for cooling with tap water. (exception:<br />
minichiller)<br />
Refrigerated/Heating<br />
Thermostat<br />
is a thermostat whose working temperature<br />
range is above and below the ambient<br />
temperature, and which can either add heat<br />
to or extract heat from the bath liquid.<br />
Refrigerant<br />
This is used in the refrigeration unit within<br />
the thermostat and extracts the heat from<br />
the thermoregulating liquid, when the<br />
compressed gas expands in the evaporator.<br />
Huber has been completely CFC free<br />
since 1992 and HCFC (e.g. R22) free since<br />
1994. Huber uses only refrigerants which<br />
do no damage to the ozone layer (ODP<br />
Ozone Depletion Potential, ODP=0), and<br />
minimal Global warming potential (GWP,<br />
i.e. Green house effect).<br />
Refrigerated Thermostat<br />
is a thermostat whose working temperature<br />
range is below the ambient temperature<br />
and draws heat from the thermofluid.<br />
Huber refrigerated thermostats are strictly<br />
speaking cooling/heating thermostats,<br />
since their working temperature range is<br />
above and below the ambient temperature.<br />
Heat can be extracted from and added to<br />
the thermofluid.<br />
Standards<br />
The safety requirements for electrical<br />
Iaboratory equipment, and especially also<br />
those for thermostats, have been defined<br />
in European standards EN 61010-1 and EN<br />
61010-2-01 0, replacement for DIN 12879,<br />
among others. The terms and characteristic<br />
of characteristic data is defined in DIN<br />
12876-1 and DIN 12876-2.<br />
Suction Pressure<br />
is the negative pressure of the circulating<br />
pump of a thermostat directly at the pump<br />
suction. lf only one value is given in the<br />
GLOSSARY<br />
tables, then this involves the maximum<br />
suction pressure for zero flow rate. Pump<br />
curves illustrate suction pressure in relation<br />
to the flow rate.<br />
Through-flow Coolers (DC)<br />
are add-on coolers which are connected<br />
into an external circuit to upgrade a heating<br />
thermostat to a heating/cooling thermostat.<br />
They are used to replace water<br />
cooling, and also to extend the Iower operating<br />
temperature.<br />
www.huber-online.com · Tel. +49-781-96030<br />
61
GENERAL<br />
Hotline<br />
Have you a <strong>thermoregulation</strong> problem<br />
or questions relating to our<br />
products? You can contact us Mon-<br />
day to Friday from 7:30 to 18:00<br />
(CET).<br />
Hotline: +49-781-9603-244<br />
3-2-1 Warranty<br />
on Registration<br />
Many years experience with minimal<br />
failures have allowed us to<br />
extend our warranty conditions.<br />
Since the 1.1.2000 we have extended<br />
our warranty on the refrigeration<br />
system to 2 years.<br />
If you register your unit serial<br />
number with us (in writing), you<br />
will receive the following warranty<br />
conditions:<br />
3 Years warranty on exchangeable<br />
electronic controllers (Plug & Play),<br />
2 Years warranty on the refrige-<br />
ration technology (including compressors)<br />
and 1 Year warranty on<br />
the mechanical and electrical components.<br />
Please register your unit under<br />
SERVICE at www.huber-online.<br />
com or by Fax +49-781-57211,<br />
the warranty period starts on the<br />
dispatch date (ex works). Please<br />
note that these extended warranty<br />
conditions will not necessarily be<br />
adopted by our foreign service<br />
partners. Please speak to our distributors<br />
regarding the conditions<br />
being offered.<br />
We reserve the right to change<br />
specification at any time.<br />
We accept no liability for printing<br />
errors.<br />
62 www.huber-online.com · Tel. +49-781-96030<br />
Extract from the<br />
General Terms and<br />
Conditions<br />
Validity<br />
By placing the order the purchaser<br />
accepts the Sales, Delivery and<br />
Payment Terms of Peter Huber<br />
Kältemaschinenbau GmbH (www.<br />
huber-online.com). The specific<br />
delivery conditions are detailed in<br />
the Confirmation of Order issued<br />
by Huber.<br />
Payment Terms<br />
If pro forma payment has not been<br />
agreed, invoices are all payable<br />
within 30 days net, no discount.<br />
Delivery<br />
Delivery is always ex-works; we reserve<br />
the right to supply the goods<br />
via a third party.<br />
Transport / Transport Damage-<br />
The transport of goods is always<br />
ordered by the purchaser. Should<br />
loss or damage be incurred during<br />
transport the purchaser must contact<br />
the transport company and request<br />
that the goods are inspected<br />
by a loss adjuster, in advance of an<br />
insurance claim.<br />
Faults<br />
The purchaser must check the<br />
goods immediately on receipt, if<br />
any problems are discovered details<br />
should be forwarded to the<br />
Peter Huber Kältemaschinenbau<br />
GmbH within 5 days of receipt. If<br />
the complaint is upheld by Peter<br />
Huber Kältemaschinenbau GmbH<br />
the purchaser is entitled to claim<br />
a repair or replacement part. The<br />
purchaser can only claim damages,<br />
when he can prove that the<br />
Peter Huber Kältemaschinenbau<br />
GmbH has been grossly negligent.<br />
Claims for loss of profit will not be<br />
considered.<br />
Sale or Return of Goods<br />
If goods which have been dispatched<br />
on a sale or return basis are<br />
not returned within the agreed<br />
period the goods are then considered<br />
to be sold. If no return date<br />
is issued, it is considered to be 4<br />
weeks. The date is calculated from<br />
the date on the delivery note.<br />
Retention of Title<br />
The delivered goods shall remain<br />
the property of the Peter Huber<br />
Kältemaschinenbau GmbH until<br />
all claims against the purchaser<br />
arising from the business association<br />
have been settled.<br />
Redemption in acc. with WEEE /<br />
ElektroG (German law on electric<br />
and electronic devices)<br />
The sales prices are valid exclusive<br />
of the costs for the redemption and<br />
disposal of old devices from users<br />
other than private households.<br />
Upon request, the supplier shall<br />
also organize the redemption and<br />
recycling/disposal of such devices<br />
against compensation of the accrueing<br />
costs, given such devices are<br />
distributed by the supplier.<br />
Validity of Contract<br />
If a clause of these conditions is<br />
unworkable, the validity of the<br />
other clauses is unaffected. If one<br />
of the clauses has an unworkable<br />
section, the remainder of the clause<br />
will remain valid. The parties<br />
involved are bound to agree a<br />
replacement clause, with a similar<br />
function.
NOTES
<strong>high</strong> <strong>precision</strong> <strong>thermoregulation</strong><br />
Peter Huber Kältemaschinenbau GmbH<br />
Werner-von-Siemens-Straße 1<br />
D-77656 Offenburg /Germany<br />
Tel. +49-781-96030 · Fax +49-781-57211<br />
E-Mail: info@huber-online.com<br />