eam us<strong>in</strong>g an a<strong>to</strong>mic beam shutter, see figure 7.4. The <strong>to</strong>p of the a<strong>to</strong>mic beam shutter<br />

was polished <strong>to</strong> achieve a mirror-like f<strong>in</strong>ish, so that it is possible <strong>to</strong> look <strong>in</strong><strong>to</strong> the oven<br />

chamber as well as <strong>in</strong><strong>to</strong> the differential pump<strong>in</strong>g tube. This greatly simplifies the <strong>in</strong>itial<br />

alignment of the Zeeman slower beam through the vacuum chamber.<br />

a<strong>to</strong>mic beam<br />

shutter xed a<strong>to</strong>mic<br />

beam block<br />

Figure 7.4: A<strong>to</strong>mic beam shutter <strong>and</strong> fixed a<strong>to</strong>mic beam block <strong>in</strong>side the 6 <strong>in</strong>ch nipple.<br />

In addition <strong>to</strong> the movable a<strong>to</strong>mic beam shutter, a fixed a<strong>to</strong>mic beam block is<br />

mounted <strong>to</strong> a 6 <strong>in</strong>ch flange at the bot<strong>to</strong>m of the 6 <strong>in</strong>ch nipple, see figure 7.4. At the<br />

a<strong>to</strong>mic beam height the beam block has a 5 mm diameter hole. This setup only allows<br />

a<strong>to</strong>ms with<strong>in</strong> a small divergence angle <strong>to</strong> enter the differential pump<strong>in</strong>g tube. The beam<br />

block reduces the flux of a<strong>to</strong>ms <strong>to</strong> the science chamber by select<strong>in</strong>g only a<strong>to</strong>ms with<strong>in</strong> a<br />

small divergence angle around the Zeeman slower axis.<br />

A titanium sublimation pump is mounted on <strong>to</strong>p of the 6 <strong>in</strong>ch nipple. In between<br />

the 6 <strong>in</strong>ch nipple <strong>and</strong> the differential pump<strong>in</strong>g tube, an all-metal gate valve (VAT Valve,<br />

48124-CE01) allows for separation of the vacuum chamber <strong>in</strong><strong>to</strong> two separate chambers.<br />

This way the vacuum pressure <strong>in</strong> the science chamber can be ma<strong>in</strong>ta<strong>in</strong>ed, even when<br />

vacuum needs <strong>to</strong> be broken on the oven chamber side <strong>to</strong> refill lithium.<br />

Perpendicular <strong>to</strong> the Zeeman slower axis a 90 ◦ elbow is attached. An ion pump<br />

(Duniway S<strong>to</strong>ckroom, VA-60-TR), an ion gauge (Duniway S<strong>to</strong>ckroom, I-NUDE-F) with<br />

95