Waste Pile Inspection - 40 CFR 264.254 Not Applicable. The facility does not have any hazardous waste surface impoundments. Land Treatment Inspection - 40 CFR 264.278 Not Applicable. The facility does not have any hazardous waste surface impoundments. Landfill Inspection - 40 CFR 264.303 Not Applicable. The facility does not have any hazardous waste surface impoundments. Incinerator Inspection - 40 CFR 264.347 Not Applicable. The facility does not have any hazardous waste surface impoundments. Run-On and Run-Off Not applicable because this TSF is an enclosed facility. No run-on/run-off control systems are present. Security, Safety, and Emergency Response Equipment Security fences and gates and safety and emergency response equipment listed in the Contingency Plan are inspected monthly to ensure the equipment is operable and available, as appropriate. Monitoring Well Inspections Wells are inspected to verify they are locked, undamaged, and free from apparent tampering on a quarterly basis. Miscellaneous Unit Inspections – 40 CFR 264.602 Retort Circuit The retort skid is visually inspected daily. Operating units (two domes, condenser, and air cooling unit) are inspected for indications of a leak or malfunction. Inspection findings are recorded on the inspection form. The functionality of retort circuit controller is observed. Filter Press The filter press skid is visually inspected daily. The unit is inspected for indications of leaks or malfunction. The area surrounding the filter cake collection containers is inspected for indications of spills and cleaned, as necessary. Inspection findings are recorded on the inspection form. The functionality of the filter press instrumentation is observed. Inspection Plan App 4A-Page 4 JBR Environmental Consultants, Inc. March 2013
Boilers and Industrial Furnaces Inspection – 40 CFR 264.15, 266102, and 266.11 Not Applicable. The facility does not have any hazardous boilers or industrial furnaces. Containment Building Inspection – 40 CFR 270.14 and 264.1101 Not Applicable. The facility does not have containment buildings as defined. Inspection Plan App 4A-Page 5 JBR Environmental Consultants, Inc. March 2013
- Page 355 and 356: Table 4. Suitable Filter Holders 1
- Page 357 and 358: Table 6. Multi-Laboratory TCLP Meta
- Page 359 and 360: Table 8. Multi-Laboratory Semi-Vola
- Page 361 and 362: Figure 1. Rotary Agitation Apparatu
- Page 363 and 364: METHOD 1311 (CONTINUED) TOXICITY CH
- Page 365 and 366: Designation: D4979 − 08 Standard
- Page 367 and 368: Designation: D4978 − 95 (Reapprov
- Page 369 and 370: FIG. 1 Method B, Sulfide Test Appar
- Page 371 and 372: TABLE 1 Determination of Bias, Pycn
- Page 373 and 374: for four known specific gravity lev
- Page 375 and 376: 21.7.1 To check the precision of sa
- Page 377 and 378: Designation: D4981 − 08 Standard
- Page 379 and 380: Designation: D5058 − 12 Standard
- Page 381 and 382: 11.6.1 Compare the temperature here
- Page 383 and 384: APPENDIX 2-E Characterization Data
- Page 385 and 386: 5. Fire-fighting measures General I
- Page 387 and 388: Carcinogenicity: CAS# 10112‐91‐
- Page 393 and 394: Combined Hazen Solution Analysis pH
- Page 395 and 396: irritation and possible burns. May
- Page 397 and 398: OSHA Vacated PELs: Mercury: 0.05 mg
- Page 399 and 400: Chemical waste generators must dete
- Page 401 and 402: APPENDIX 4-A Inspection Plan
- Page 403 and 404: 1 INSPECTION PLAN This Inspection P
- Page 405: Inspections are intended to detect
- Page 409 and 410: PMR Daily Inspection Form #1 Date:
- Page 411 and 412: PMR Daily Inspection Form #2 Date:
- Page 413 and 414: PMR Weekly Inspection Form #3 Date:
- Page 415 and 416: damage or vandalism. Other Inspecti
- Page 417 and 418: TABLE OF CONTENTS 1 CONTINGENCY PLA
- Page 419 and 420: Potential Emergency Condition Fire,
- Page 421 and 422: Other duties of the emergency coord
- Page 423 and 424: Determine proper storage and placem
- Page 425 and 426: Neoprene boots - protect feet. Res
- Page 427 and 428: Fire Extinguishers. Absorbent pads
- Page 429 and 430: Table 2: Coordinating Agency Contac
- Page 431 and 432: Stay low in smoke filled areas. Co
- Page 433 and 434: the area or the National Response C
- Page 435 and 436: Description of the spilled material
- Page 437 and 438: APPENDIX 6-B Emergency Coordinators
- Page 439: Ambulance EXTERNAL CONTACTS Name Ti
Boilers and Industrial Furnaces Inspection – 40 CFR 264.15, 266102, and 266.11<br />
Not Applicable. The facility does not have any hazardous boilers or industrial furnaces.<br />
Containment Building Inspection – 40 CFR 270.14 and 264.1101<br />
Not Applicable. The facility does not have containment buildings as defined.<br />
Inspection Plan App 4A-Page 5<br />
JBR Environmental Consultants, Inc. March 2013