A<br />

B<br />

C<br />

D<br />

E<br />

F<br />

$$W ATERMARKD$$<br />

H340940-1400-05-030-0005<br />

TANK OFF-GAS<br />

1500-05-030-0003<br />

WASTE SOLUTION STORAGE TANK<br />

TANK OFF-GAS<br />

1400-05-030-0004<br />

WASTE SOLUTION TREATMENT<br />

TANK OFF-GAS<br />

1400-05-030-0002<br />

CAUSTIC LEACH CIRCUIT<br />

BUILDING VENTILATION<br />

HVAC<br />

NOTE 2<br />

TREATED RETORT OFF-GAS<br />

1400-05-030-0003<br />

RETORT SO SCRUBBER<br />

2<br />

COMPRESSED AIR<br />

1500-05-030-0001<br />

DISTRIBUTION<br />

HYGIENE GAS<br />

1400-05-030-0001<br />

RETORT AREA<br />

HYGIENE GAS<br />

1400-05-030-0002<br />

FILTER PRESS AREA<br />

1 2 3 4 5 6 7 8<br />

452<br />

258<br />

167<br />

301<br />

351<br />

107<br />

168<br />

DWG. NO.<br />

DRAWING NO. DRAWING TITLE<br />

REFERENCE DRAWINGS<br />

1430-CL-040 1430-CL-041<br />

CARBON COLUMN #1 CARBON COLUMN #2<br />

2<br />

1<br />

0<br />

C<br />

B<br />

A<br />

305<br />

NOTE 1<br />

1450-DC-101<br />

HYGIENE DUST COLLECTOR<br />

VENT GAS HEPA FILTER<br />

1450-FE-111<br />

DUST COLLECTOR<br />

ROTARY VALVE<br />

1430-FL-110<br />

ISSUED FOR INFORMATION KM AO<br />

1430-FA-123<br />

STAND BY<br />

VENT GAS FAN<br />

1430-FA-044<br />

VENT GAS FAN<br />

ISSUE FOR DESIGN EC SS 2012-12-14<br />

ISSUE FOR DESIGN<br />

ISSUE FOR DESIGN DE AO 2012-10-22<br />

REVISED & ISSUED FOR DISCIPLINE REVIEW DE AO 2012-10-12<br />

ISSUED FOR CLIENT REVIEW KM AO 2012-06-19<br />

DR<br />

SS 2012-11-14<br />

1450-FL-105<br />

DUST COLLECTOR<br />

OUTLET HEPA FILTER<br />

1450-FL-106<br />

CARBON FILTER<br />

NO. DESCRIPTION BY CHK’D APP’D DATE REV. ISSUE FOR AUTH. BY DATE<br />

REVISIONS<br />

ISSUE AUTHORIZATION<br />

FORKLIFT<br />

1450-FA-107<br />

HYGIENE FAN<br />

1450-FA-112<br />

STAND-BY<br />

HYGIENE FAN<br />

DESIGNED BY<br />

R. FUKUZAWA<br />

DATE<br />

G. KERAMARIS<br />

M. SUCHARDA<br />

DRAWN BY<br />

K. MCLEAN<br />

CHECKED BY DISCIP. ENGR.<br />

DATE<br />

PROJ. DES. COORD.<br />

DATE<br />

R. FUKUZAWA<br />

DATE<br />

J. CHALMERS S. SENNIK<br />

DATE DATE<br />

PROJ. ENGR.<br />

PROJ. MGR. SCALE<br />

NTS<br />

OR AS NOTED<br />

NOTE:<br />

1.<br />

2.<br />

DUST COLLECTOR BYPASS LINE AS PROVISION<br />

FOR MAINTENANCE. TO BE USED ONLY WHEN<br />

NO DUST GENERATING ACTIVITIES OCCURING.<br />

SEE PROCESS/STORAGE BUILDING HVAC<br />

CONTROL SCHEMATIC H340940-0000-45-083-0001.<br />

TO ATMOSPHERE<br />

302<br />

1430-SK-045<br />

EXHAUST DUCT<br />

303<br />

LEGEND<br />

DUST COLLECTOR DUST<br />

1400-05-030-0001<br />

RETORT<br />

MAJOR PROCESS<br />

SECONDARY PROCESS<br />

INTERMITTENT PROCESS<br />

VENDOR SUPPLY LIMIT<br />

DUST PICKUP POINTS<br />

PRECIOUS METALS RECOVERY <strong>LLC</strong><br />

DRY HILLS FACILITY PROJECT<br />

HYGIENE & VENT GAS<br />

TREATMENT AND EXHAUST<br />

PROCESS FLOW DIAGRAM<br />

DWG. NO.<br />

H340940-1400-05-030-0005<br />

1 2 3 4 5 6 7 8<br />

DATE<br />

PRECIOUS METALS RECOVERY <strong>LLC</strong><br />

REV.<br />

2<br />

A<br />

B<br />

C<br />

D<br />

E