Table 2.5-2: Test Methods<br />

Parameter Method Name Method Number<br />

Leachable <strong>Metals</strong> TCLP SW-846 Method 1311<br />

Total <strong>RCRA</strong> <strong>Metals</strong><br />

TCLP<br />

XRF Evaluation<br />

SW-846 Method 1311 (Total)<br />

SW-846 Method 6200<br />

SW-846 Method 9040 (liquids)<br />

Corrosivity pH<br />

SW-846 Method 9045 (nonliquids)<br />

Total Organics TCLP SW-846 Method 1311 (Total)<br />

Ignitability Flashpoint ASTM D93-11<br />

Free Liquids Paint Filter Test SW-846 Method 9095<br />

An appropriately certified off-site analytical laboratory will analyze waste characterization<br />

samples for the applicable SW-846 or ASTM method. The analytical laboratory selected for<br />

these analyses will be required to comply with SW-846 Quality Assurance/Quality Control<br />

procedures for each procedure performed.<br />

2.6 Sampling Methods – 40 CFR 264.13(b)(2) & 40 CFR 264.13(b)(3)<br />

2.6.1 Collection Method<br />

The appropriate representative sampling techniques, devices, and containers will be selected<br />

from the SW-846 or the ASTM method. Samples will be collected in a representative<br />

manner, either as a composite sample or as a discrete grab sample (i.e., randomly collected<br />

small sample), based on the material characteristics, container size, and access.<br />

Safe sampling procedures will be developed and reviewed prior to implementation.<br />

Laboratory preparation methods will be selected based on the data use. If the TCLP<br />

procedure is required for characterization, the appropriate leaching and extraction methods<br />

specified in SW-846 will be followed. All metals samples will be preserved per quality<br />

control requirements. Specific sampling methods and analytical methods are specified in<br />

Table 2.6-1.<br />

Repeat negative results may result in the analysis being removed for that waste stream.<br />

Multiple negative results during initial characterization for a parameter may result in<br />

removing a parameter from the analytical list for that waste stream.<br />