Calculation of Absorptivity<br />

Absorptivity (ABU-L/g-cm) =<br />

Where:<br />

Example<br />

ABS std # x df<br />

Iron Stock Conc.<br />

ABS std # = recorded absorbance for each standard<br />

measured at 477 nm<br />

df = dilution factor for corresponding standard<br />

1000 mL 100 mL<br />

x<br />

3.0 mL pipet size<br />

Iron Stock Conc. = calculated amount of iron in iron wire<br />

stock solution (refer to section on<br />

Preparation of 10 g/L Iron Stock<br />

Solution.)<br />

Absorptivity (ABU-L/g-cm) =<br />

0.330 x 6666.7<br />

= 205.7<br />

10.695<br />

Typical Absorptivity<br />

mL Diluted Stock Absorbance Absorptivity<br />

3.0 0.192 204.85<br />

3.0 0.195 204.05<br />

3.0 0.194 206.99<br />

5.0 0.322 206.13<br />

5.0 0.319 204.21<br />

5.0 0.322 206.13<br />

10.0 0.638 204.21<br />

10.0 0.642 205.49<br />

10.0 0.641 205.17<br />

15.0 0.955 203.78<br />

15.0 0.953 203.36<br />

15.0 0.958 204.42<br />

x = 205.2<br />

s = 1.4<br />

Figure 1 Calibration of Total Iron in ECN-2 or ECP-2<br />

“KUL” Bleach<br />

0.00<br />

0<br />

F002_0937AC<br />

6 <strong>Processing</strong> KODAK Motion Picture Films, Module 3, Analytical Procedures H24.03<br />

Absorbance @ 447 nm<br />

1.20<br />

1.00<br />

0.80<br />

0.60<br />

0.40<br />

0.20<br />

2<br />

4<br />

ABSORBANCE<br />

6<br />

mL Diluted Stock<br />

8<br />

10<br />

12<br />

14<br />

16<br />

18<br />

20