Absorbance Measurement<br />

Measure the absorbance of the dilution with the<br />

spectrophotometer at 345 nm (A34s). Use the hydrogen<br />

lamp. See instructions given in Method ULM-0001/1,<br />

Instructions for Performance Checks of Ultraviolet-Visible<br />

Spectrophotometers and Quartz Cells.<br />

Calculations<br />

Citrazinic acid, g/L = 2.53(A 345 ) + 0.09<br />

2 <strong>Processing</strong> KODAK Motion Picture Films, Module 3, Analytical Procedures H24.03