Slowly slide the choke control back to the middle<br />

position when the engine has started.<br />

Set the desired engine speed with the throttle. Allow<br />

the engine to run at a moderate speed, “half throttle”<br />

for 3-5 minutes before loading it to heavily. USE FULL<br />

THROTTLE WHEN MOWING (no choke).<br />

Weak Battery<br />

WARNING!<br />

Engine exhaust and certain vehicle<br />

c<strong>om</strong>ponents contain or emit chemicals<br />

considered to cause cancer, birth<br />

defects, or other reproductive system<br />

damage. The engine exhaust contains<br />

carbon monoxide, which is a odorless,<br />

colorless, poisonous gas. Do not use<br />

the machine in enclosed spaces.<br />

WARNING!<br />

Lead-acid batteries generate<br />

explosive gases. Keep sparks,<br />

flame and smoking materials away<br />

fr<strong>om</strong> batteries. Always wear eye<br />

protection when around batteries.<br />

If your battery is too weak to start the engine, it should<br />

be recharged. (See “Battery” in the Maintenance<br />

Section.)<br />

If “jumper cables” are used for emergency starting,<br />

follow this procedure:<br />

Jumper cables<br />

• Connect each end of the RED cable to the<br />

POSItIVE (+) terminal on each battery, taking<br />

care not to short against chassis.<br />

• Connect one end of the BLACK cable to the<br />

NEGAtIVE (-) terminal of the fully charged battery.<br />

• Connect the other end of the BLACK cable to a<br />

good CHASSIS GROUND on the mower with the<br />

discharged battery, away fr<strong>om</strong> the fuel tank and<br />

battery.<br />

To remove cables, reverse order<br />

• Remove BLACK cable first fr<strong>om</strong> chassis and then<br />

fr<strong>om</strong> the fully charged battery.<br />

• Remove RED cable last fr<strong>om</strong> both batteries.<br />

OPERAtION<br />

Use full throttle when mowing<br />

IMPORTANT INFORMATION<br />

Your mower is equipped with a 12-volt<br />

negative grounded system. The other vehicle<br />

must also be a 12-volt negative grounded<br />

system. Do not use your mower to start other<br />

vehicles.<br />

Jumper cable connection<br />

8050-007<br />

8011-642<br />

HUSQVARNA-27