3v 3e 3v<br />

v v v v v v 3v<br />

AM BM CM AN BN CN NM<br />

ZS ZS NM<br />

vNMvZS eZS<br />

(D.22)<br />

For the impedance load it was concluded that the ZS component in the source had no ability to<br />

drive currents in the load and Equation (D.22) shows that this is true for the motor load as well. In<br />

addition Equation (D.22) shows the same comments apply to the ZS component of the bEMF.<br />

The motor load may be redrawn by using the concept in Figure D.5, as shown in Figure D.8. 54<br />

Figure D.8 – Equivalent motor bEMF arrangement.<br />

Figure D.8 shows the rearranging of the bEMF only. To show the total influence on the neutral<br />

voltage, the concept used in Figure D.6 (which was found to be valid for the motor as well) is<br />

combined with the concept shown in Figure D.8 to yield Figure D.9.<br />

54 In Figure D.7 the lines connecting source and load are thin to emphasize that the source and load are<br />

separate parts; the connection of the source to the midpoint M is likewise a lightweight line. In contrast, in<br />

Figure D.6 and Figure D.8 the “connection” to the neutral point is a heavyweight line, indicating that it is<br />

an integral part of the load.<br />

317