Figure 4.5 – Leg states for 120° inverter.<br />

Since the leg of the 180° inverter is switched either high or low, the leg state to be represented by<br />

a single variable, resulting in the simplified diagram shown in Figure 4.6.<br />

Figure 4.6 – Representation of leg in 180° inverter.<br />

The allowable leg states for the 180° inverter are shown in Figure 4.7.<br />

Figure 4.7 – Leg states for 180° inverter.<br />

So far, the definition of the two types is based on the leg control scheme: either each leg must<br />

have one transistor on at any given time (180°) or there will be a period where both transistors are<br />

off (120°). These restrictions enforce a different restriction on the allowable gating period.<br />

Traditionally, these 120° and 180° were are derived from the full-on conduction periods of the<br />

transistors or thyristors in the 120° six-step inverter and the 180° six-step inverter [79], but it is<br />

apparent from the literature that these terms have been modified over the years to accommodate<br />

PWM inverters. 180° is one half-cycle so that is the maximum. If the duration was below 120°<br />

164