Figure 37. Tetrode and pentode protection chart. This chart<br />

indicates the location of a suitable relay which should<br />

act to remove the principal supply voltage from the<br />

stage or transmitter to prevent damage to the tubes.<br />

the maximum allowable screen dissipation will almost always be<br />

exceeded and tube damage will result.<br />

Figure 38 is a chart for the protection of a triode tube. This chart<br />

covers the grid driven triode amplifier and the high-µ (zero bias)<br />

cathode driven triode amplifier. Drive voltage must never be<br />

applied to a zero-bias triode amplifier without anode voltage being<br />

applied.<br />

62