Another method of assuring that the screen grid is at rf ground is<br />

to use a quarter- wavelength coaxial stub, shorted at one end and<br />

resonant at the operating frequency, connected from the screen<br />

to ground. A blocking capacitor is required to prevent shorting<br />

the screen dc supply voltage to ground. This is generally used<br />

in an amplifier operating at a single fixed frequency at VHF. The<br />

length of the stub becomes physically too long at lower operating<br />

frequencies.<br />

3.8 GROUNDED-GRID CIRC<strong>UI</strong>TS<br />

Zero-bias triodes employed in rf power amplifiers for general<br />

purpose rf amplification, linear and even class-C FM service are<br />

typically used only in the grounded-grid configuration. The control<br />

grid is operated at rf ground, similar to the screen grid in a tetrode<br />

or pentode; therefore, good isolation is obtained between the<br />

input and output. The control grid may be bypassed directly at<br />

the socket or grounded directly to the chassis. The dc-grounded<br />

approach is favored, because no bypass capacitor is required and<br />

stability is optimum. Figures 34 and 35 illustrate the two circuit<br />

configurations.<br />

Above 30 MHz the example in fig. 35 should be avoided because<br />

of less than ideal rf grounding associated with this configuration. A<br />

case can also be made wherein fig. 35 has less inherent reliability.<br />

In the event of an internal or external arc from anode to grid, the grid<br />

bypass capacitor and metering circuit could be destroyed, unless<br />

the available energy is limited to less than a few joules. Protection<br />

diodes connected across the meters are highly recommended in<br />

both circuits.<br />

Figure 34. A typical circuit using “zero-bias” triodes showing<br />

metering circuits and method of grounding the grid<br />

to r-f. The grid current is measured in the return lead<br />

from ground to filament.<br />

59