Manual CEPR 96 - Balogh technical center

Manual CEPR 96 - Balogh technical center Manual CEPR 96 - Balogh technical center

technical.balogh.rfid.com
from technical.balogh.rfid.com More from this publisher
17.07.2013 Views

Instructions manual for CEPR96 / MRUC20 M97.10.01 SYNTAX Hexadecimal : Mnemonic : EXECUTION READ the ACCUMULATOR MEMORY REQUEST RESPONSE NC 24 FF NB AD0...ADN...04 NC 24 FF NB AD0 DV0..ADN DVN..04 LD ,ADO...,ADN. SUPERVISION SEPARATED FORMAT MEMOIRE ACCU ADN DVN COMMENTS Allows to read the Accumulator memory (the selected one). The separated format dictate to the user to specify each address to read. The response is return as : address,data;address,data... SYMBOLS DEFINITION LIMITS EXAMPLE To read address 00H and 7FH from the accumulator memory. REQUEST : hexa : 01 24 FF 07 00 7F 04 mné. : LD,0,7FH. PAGE 8 USER NB Number of bytes for the message 0 à FFH ADN address to read 0 à FFH DVN Data return from the address ADN 0 à FFH RESPONSE : Data from address 00H and 7FH have the values 4EH et 00. hexa : 01 24 FF 09 00 4E 7F 00 04 24H LD

SYNTAX Hexadecimal : Mnémonic : EXECUTION COMMENTS SYMBOLS DEFINITION LIMITS EXAMPLE Read the data from the bloc defined as 07H to 0BH in the accumulator memory (NC=01). PAGE 9 Instructions manual for CEPR96 / MRUC20 M97.10.01 READ the ACCUMULATOR MEMORY REQUEST RESPONSE NC 25 FF 07 ADdeb ADfin 04 NC 25 FF NB ADdeb ADfin DVO..DVN 04 LD.B,ADdeb,ADfin. SUPERVISION BLOC FORMAT MEMOIREACCU. ADdeb ADfin DVN USER 25H LD.B Allows to the user to get a bloc of data from the selected accumulator memory. The bloc format dictate to the user to specify the first address and the last address of the bloc to read. The response is return as a data list (data between ADdeb and ADfin). NB number of bytes for the message. ADdeb First address of the bloc. ADfin Last address of the bloc. DVN Data from the defined bloc DEMANDE :hexadecimal : NC 25 FF 07 07 0B 04 mnemonic : LD.B,07,0B. RESPONSE : from address 07 to 0BH the data are (in héxa) 0C, 4F, 5E, FF et 04. hexadecimal : NC 25 FF 0C 07 0B 0C 4F 5E FF 04 04 0 à FFH 0 à FFH 0 à FFH 0 à FFH

SYNTAX<br />

Hexadecimal :<br />

Mnémonic :<br />

EXECUTION<br />

COMMENTS<br />

SYMBOLS DEFINITION LIMITS<br />

EXAMPLE<br />

Read the data from the bloc defined as 07H to 0BH in the accumulator memory (NC=01).<br />

PAGE 9<br />

Instructions manual for <strong>CEPR</strong><strong>96</strong> / MRUC20 M97.10.01<br />

READ the ACCUMULATOR MEMORY<br />

REQUEST RESPONSE<br />

NC 25 FF 07 ADdeb ADfin 04 NC 25 FF NB ADdeb ADfin DVO..DVN 04<br />

LD.B,ADdeb,ADfin.<br />

SUPERVISION<br />

BLOC FORMAT<br />

MEMOIREACCU.<br />

ADdeb<br />

ADfin<br />

DVN<br />

USER<br />

25H<br />

LD.B<br />

Allows to the user to get a bloc of data from the selected accumulator memory. The<br />

bloc format dictate to the user to specify the first address and the last address of the<br />

bloc to read.<br />

The response is return as a data list (data between ADdeb and ADfin).<br />

NB number of bytes for the message.<br />

ADdeb First address of the bloc.<br />

ADfin Last address of the bloc.<br />

DVN Data from the defined bloc<br />

DEMANDE :hexadecimal : NC 25 FF 07 07 0B 04<br />

mnemonic : LD.B,07,0B.<br />

RESPONSE : from address 07 to 0BH the data are (in héxa) 0C, 4F, 5E, FF et 04.<br />

hexadecimal : NC 25 FF 0C 07 0B 0C 4F 5E FF 04 04<br />

0 à FFH<br />

0 à FFH<br />

0 à FFH<br />

0 à FFH