Manual CEPR 96 - Balogh technical center
Manual CEPR 96 - Balogh technical center
Manual CEPR 96 - Balogh technical center
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Instructions manual for <strong>CEPR</strong><strong>96</strong> / MRUC20 M97.10.01<br />
SYNTAX<br />
Hexadecimal : NC 1E NL NB ADdeb ADfin DV0 ..DVN..04<br />
Mnemonic :<br />
EXECUTION<br />
COMMENTS<br />
Transfert a bloc of immediat data (DB) into the accumulator memory. The destination<br />
bloc is define by the first address to write (ADdeb) and the last address to write (ADfin).<br />
If only 1 data is given, the data is write everywhere in the destination table.<br />
EXAMPLE<br />
ACCU. MEMORY<br />
ADdeb<br />
ADfin<br />
SYMBOLS DEFINITION LIMITS<br />
Clear the ACCU memory by write 0 in the 256 bytes of the zone.<br />
Hexadecimal : NC 1E FF 08 00 FF 00 04<br />
Mnemonic : MOV.B,0,FFH,0.<br />
DATA TRANSFERT<br />
IMMEDIAT ADRESSING - BLOC FORMAT<br />
MOV.B,ADdeb,ADfin,DV0..,DVN.<br />
PAGE 14<br />
IMMEDIATE<br />
ADDRESSING<br />
ADdeb First address of the destination zone<br />
ADfin Last address of the destination zone<br />
DVN List of data to write<br />
DV The same value to write everywhere<br />
DB :<br />
Data bloc<br />
DVN<br />
DVN..<br />
1EH<br />
MOV.B<br />
0 to FFH<br />
0 to FFH<br />
0 to FFH<br />
0 to FFH