5. Final finishing<br />

<strong>JAEA</strong>-<strong>Testing</strong> <strong>2011</strong>-007<br />

<strong>JAEA</strong>-<strong>Testing</strong> <strong>2011</strong>-007<br />

(1) Measure ambient dose rate at the condition without pool water<br />

(a) Measure the ambient dose rate at the bottom of the swimming pool and pool<br />

side.<br />

Survey ambient dose rates at the same measurement points as those before<br />

starting the work (Record 2: Ambient dose rate map of the swimming pool and<br />

pool side before the work)<br />

Measurement points are at four corners and the center, in principle, of the bottom<br />

of the swimming pool. Add locations where drain water is collected such as drain<br />

port as measurement points.<br />

Write down the measurement results in the form, “Record 19: Ambient dose rate<br />

map at the pool and pool side”.<br />

(b) Survey ambient dose rate at the places used for the work<br />

Survey ambient dose rate at the same measurement points as those in the<br />

swimming pool, outlet to external water way, along work flow lines, temporary<br />

storage of waste surveyed before starting the procedures, and write down the<br />

measurement results in the form, “Record 20: Ambient dose rate map in the work<br />

area (after the work)”.<br />

- 175<br />