(e) 3 rd treatment of the supernatant and precipitate<br />

When the radioactivity concentration of the supernatant after secondary<br />

treatment is higher than the criteria for discharge, transfer the water in the 1 ton<br />

plastic tank to 100 L tank using a small capacity engine pump where 3rd treatment is conducted using the zeolite (photos shown below). Measure the<br />

radioactivity of the transferred water and write down the measurement results in<br />

the form, “Record 14: Radioactivity concentration in the supernatant before the<br />

3rd treatment”.<br />

Add zeolite to the water in the 100 L tank. No flocculant (PAC) is used in the 3rd treatment.<br />

Transfer supernatant with the radioactivity concentration higher<br />

than the criteria for discharge to the 100 L tank using a small<br />

capacity engine pump, and provide 3 rd treatment using the zeolite.<br />

Add zeolite only for the 3 rd treatment<br />

Treat the precipitate left on the bottom of the tank using the same method as that<br />

applied to the precipitate left on the bottom of the plastic tank, as described in the<br />

section “(6) Treat the precipitate left on the bottom of the 1 ton plastic tanks”.<br />

Keep at rest for one night and measure radioactivity concentration of filtrated<br />

water accumulated in the tray, and write down the results in the form, “Record 15:<br />

Radioactivity concentration in the water after filtration with a filter cloth”.<br />

When the radioactivity concentration is lower than that in the criteria for<br />

discharge, discharge the water in the tray. When it is higher, dilute the water with<br />

the tap water, and discharge it after checking for the compliance.<br />

- 163 -<br />