JAEA-Testing-2011-007.pdf:46.74MB - 日本原子力研究開発機構
JAEA-Testing-2011-007.pdf:46.74MB - 日本原子力研究開発機構
JAEA-Testing-2011-007.pdf:46.74MB - 日本原子力研究開発機構
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>JAEA</strong>-<strong>Testing</strong> <strong>2011</strong>-007<br />
<strong>JAEA</strong>-<strong>Testing</strong> <strong>2011</strong>-007<br />
(e) 3 rd treatment of the supernatant and precipitate<br />
When the radioactivity concentration of the supernatant after secondary<br />
treatment is higher than the criteria for discharge, transfer the water in the 1 ton<br />
plastic tank to 100 L tank using a small capacity engine pump where 3rd treatment is conducted using the zeolite (photos shown below). Measure the<br />
radioactivity of the transferred water and write down the measurement results in<br />
the form, “Record 14: Radioactivity concentration in the supernatant before the<br />
3rd treatment”.<br />
Add zeolite to the water in the 100 L tank. No flocculant (PAC) is used in the 3rd treatment.<br />
Transfer supernatant with the radioactivity concentration higher<br />
than the criteria for discharge to the 100 L tank using a small<br />
capacity engine pump, and provide 3 rd treatment using the zeolite.<br />
Add zeolite only for the 3 rd treatment<br />
Treat the precipitate left on the bottom of the tank using the same method as that<br />
applied to the precipitate left on the bottom of the plastic tank, as described in the<br />
section “(6) Treat the precipitate left on the bottom of the 1 ton plastic tanks”.<br />
Keep at rest for one night and measure radioactivity concentration of filtrated<br />
water accumulated in the tray, and write down the results in the form, “Record 15:<br />
Radioactivity concentration in the water after filtration with a filter cloth”.<br />
When the radioactivity concentration is lower than that in the criteria for<br />
discharge, discharge the water in the tray. When it is higher, dilute the water with<br />
the tap water, and discharge it after checking for the compliance.<br />
- 163 -<br />
- 163 -