(c) Secondary treatment of the water left in the 1 ton plastic tanks<br />
Similar to precedent works, feed 100 g of the zeolite and 150 mL of the flocculant<br />
(PAC solution) into each 1 ton plastic tank.<br />
Pour suspended zeolite solution prepared in a separate container and stir it with a<br />
long handle ladle. After 30 minutes, add 150 ml of the flocculant (PAC solution)<br />
and stir it with a long handle ladle.<br />
Keep the plastic tank at rest for one night to allow the zeolite and flocculant<br />
functioning sufficiently effective.<br />
Secondary treatment using the zeolite: Feed 100 g/ton of zeolite, and<br />
150 ml/ton of flocculant (PAC, and leave it for one night.)<br />
Feed the zeolite and stir with a ladle. Feed the PAC and stir with a ladle.<br />
(d) Measure radioactivity of the supernatant, and discharge it when it meet the<br />
criteria.<br />
Measure the radioactivity of the supernatant in each plastic tank. Write down the<br />
measurement results in the form, “Record 13: Radioactivity concentration in the<br />
pool water and precipitate after the 2nd treatment”<br />
Discharge the supernatant using a medium capacity engine pump while taking<br />
care of not to pump precipitate when the radioactivity concentration meets the<br />
criteria for discharge. When it does not meet the criteria for discharge, provide 3rd treatment as described in the section (e).<br />
- 159 -<br />