Technical Product Specification for Canoe Pass - Preminary - Intel
Technical Product Specification for Canoe Pass - Preminary - Intel
Technical Product Specification for Canoe Pass - Preminary - Intel
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Intel</strong> ® Server Board S2600CP and Server System P4000CP TPS<br />
<strong>Intel</strong> ® Server Board S2600CP and <strong>Intel</strong> ® Server System P4000CP Plat<strong>for</strong>m Management<br />
LDAP server <strong>for</strong> login authentication. This is only supported <strong>for</strong> non-IPMI logins including the<br />
embedded web UI and SM-CLP. IPMI users/passwords and sessions are not supported over<br />
LDAP.<br />
LDAP can be configured (IP address of LDAP server, port, etc.) via the IBMC’s Embedded Web<br />
UI. LDAP authentication and authorization is supported over the any NIC configured <strong>for</strong> system<br />
management. The BMC uses a standard Open LDAP implementation <strong>for</strong> Linux.<br />
5.3 Plat<strong>for</strong>m Control<br />
This server plat<strong>for</strong>m has embedded plat<strong>for</strong>m control which is capable of automatically adjusting<br />
system per<strong>for</strong>mance and acoustic levels.<br />
Acoustic<br />
Management<br />
Per<strong>for</strong>mance<br />
Management<br />
Figure 20. Plat<strong>for</strong>m Control<br />
Plat<strong>for</strong>m control optimizes system per<strong>for</strong>mance and acoustics levels through:<br />
Per<strong>for</strong>mance management<br />
Per<strong>for</strong>mance throttling<br />
Thermal monitoring<br />
Fan speed control<br />
Acoustics management<br />
Integrated<br />
Control<br />
Fan Speed<br />
Control<br />
The plat<strong>for</strong>m components used to implement plat<strong>for</strong>m control include:<br />
Integrated baseboard management controller<br />
Plat<strong>for</strong>m sensors<br />
Variable speed system fans<br />
System BIOS<br />
BMC firmware<br />
Revision 0.8 <strong>Intel</strong> Confidential<br />
<strong>Intel</strong> order number G26942-003<br />
Per<strong>for</strong>mance<br />
Throttling<br />
Thermal<br />
Monitoring<br />
57