<strong>Intel</strong> ® Server Board S2600CP and <strong>Intel</strong> ® Server System P4000CP Plat<strong>for</strong>m Management<br />

<strong>Intel</strong> ® Server Board S2600CP and Server System P4000CP TPS<br />

52<br />

o Inventory data/system in<strong>for</strong>mation export (partial SMBIOS table)<br />

Enhancements to fan speed control.<br />

DCMI compliance (product-specific).<br />

Support <strong>for</strong> embedded web server UI in Basic Manageability feature set.<br />

Enhancements to embedded web server<br />

o Human-readable SEL<br />

o Additional system configurability<br />

o Additional system monitoring capability<br />

o Enhanced on-line help<br />

Enhancements to KVM redirection<br />

o Support <strong>for</strong> higher resolution<br />

Support <strong>for</strong> EU Lot6 compliance<br />

Management support <strong>for</strong> PMBus rev1.2 compliant power supplies<br />

Integrated BMC FW reliability enhancements:<br />

o Redundant Integrated BMC boot blocks to avoid possibility of a corrupted boot<br />

block resulting in a scenario that prevents a user from updating the Integrated<br />

BMC.<br />

5.2 Basic and Optional Advanced Management Features<br />

This section explains the advanced management features supported by the BMC firmware. The<br />

table in below lists basic and advanced feature support. Individual features may vary by plat<strong>for</strong>m.<br />

Table 15. Basic and Advanced Management Features<br />

Feature Basic* Advanced**<br />

IPMI 2.0 Feature Support X X<br />

In-circuit BMC Firmware Update X X<br />

FRB 2 X X<br />

Chassis Intrusion Detection X X<br />

Fan Redundancy Monitoring X X<br />

Hot-Swap Fan Support X X<br />

Acoustic Management X X<br />

Diagnostic Beep Code Support X X<br />

Power State Retention X X<br />

ARP/DHCP Support X X<br />

PECI Thermal Management Support X X<br />

E-mail Alerting X X<br />

Embedded Web Server X X<br />

SSH Support X X<br />

Integrated KVM X<br />

Integrated Remote Media Redirection X<br />

Local Directory Access Protocol (LDAP) X X<br />

<strong>Intel</strong> Confidential Revision 0.8<br />

<strong>Intel</strong> order number G26942-003