<strong>Intel</strong> ® Server Board S2600CP and <strong>Intel</strong> ® Server System P4000CP Plat<strong>for</strong>m Management<br />
<strong>Intel</strong> ® Server Board S2600CP and Server System P4000CP TPS<br />
52<br />
o Inventory data/system in<strong>for</strong>mation export (partial SMBIOS table)<br />
Enhancements to fan speed control.<br />
DCMI compliance (product-specific).<br />
Support <strong>for</strong> embedded web server UI in Basic Manageability feature set.<br />
Enhancements to embedded web server<br />
o Human-readable SEL<br />
o Additional system configurability<br />
o Additional system monitoring capability<br />
o Enhanced on-line help<br />
Enhancements to KVM redirection<br />
o Support <strong>for</strong> higher resolution<br />
Support <strong>for</strong> EU Lot6 compliance<br />
Management support <strong>for</strong> PMBus rev1.2 compliant power supplies<br />
Integrated BMC FW reliability enhancements:<br />
o Redundant Integrated BMC boot blocks to avoid possibility of a corrupted boot<br />
block resulting in a scenario that prevents a user from updating the Integrated<br />
BMC.<br />
5.2 Basic and Optional Advanced Management Features<br />
This section explains the advanced management features supported by the BMC firmware. The<br />
table in below lists basic and advanced feature support. Individual features may vary by plat<strong>for</strong>m.<br />
Table 15. Basic and Advanced Management Features<br />
Feature Basic* Advanced**<br />
IPMI 2.0 Feature Support X X<br />
In-circuit BMC Firmware Update X X<br />
FRB 2 X X<br />
Chassis Intrusion Detection X X<br />
Fan Redundancy Monitoring X X<br />
Hot-Swap Fan Support X X<br />
Acoustic Management X X<br />
Diagnostic Beep Code Support X X<br />
Power State Retention X X<br />
ARP/DHCP Support X X<br />
PECI Thermal Management Support X X<br />
E-mail Alerting X X<br />
Embedded Web Server X X<br />
SSH Support X X<br />
Integrated KVM X<br />
Integrated Remote Media Redirection X<br />
Local Directory Access Protocol (LDAP) X X<br />
<strong>Intel</strong> Confidential Revision 0.8<br />
<strong>Intel</strong> order number G26942-003