03.07.2013 Views

Technical Product Specification for Canoe Pass - Preminary - Intel

Technical Product Specification for Canoe Pass - Preminary - Intel

Technical Product Specification for Canoe Pass - Preminary - Intel

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Intel</strong> ® Server Board S2600CP and Server System P4000CP TPS <strong>Intel</strong>® Server Board S2600CP Functional Architecture<br />

4.3.23 On-board SAS/SATA Support and Options<br />

The <strong>Intel</strong> ® C600 chipset provides storage support via two integrated controllers: AHCI and SCU.<br />

By default the server board will support up to 10 SATA ports: Two white 6Gb/sec SATA ports<br />

and four black 3Gb/sec SATA ports routed from the AHCI controller labeled as “SATA_0”<br />

through “SATA_5” and eight blue 6Gb/sec SATA/SAS ports routed from the SCU controller<br />

labeled as “SAS_0” through “SAS_7”.<br />

Note: The four blue ports from SCU labeled as “SAS_4”~”SAS_7” are NOT functional by default<br />

and is only enabled with the addition of an <strong>Intel</strong> ® RAID C600 Upgrade Key option supporting 8<br />

SAS/SATA ports.<br />

The server board is capable of supporting additional chipset embedded SAS and RAID options<br />

from the SCU controller when configured with one of several available <strong>Intel</strong> ® RAID C600<br />

Upgrade Keys. Upgrade keys install onto a 4-pin connector on the server board labeled as<br />

“Storage Upgrade key”. The following table identifies available upgrade key options and their<br />

supported features.<br />

The storage ports from SCU can be configured with the two embedded software RAID options:<br />

<strong>Intel</strong> ® Embedded Server RAID Technology 2 (ESRT2) based on LSI* MegaRAID SW<br />

RAID technology supporting RAID levels 0,1,and 10.<br />

<strong>Intel</strong> ® Rapid Storage Technology (RSTe) supporting RAID levels 0, 1, 5, and 10.<br />

Table 12. <strong>Intel</strong> ® RAID C600 Upgrade Key Options<br />

<strong>Intel</strong> ® RAID C600 Upgrade Key Options<br />

(<strong>Intel</strong> <strong>Product</strong> Codes)<br />

Key Color Description<br />

Default – No option key installed N/A 4 Port SATA with <strong>Intel</strong> ® ESRT RAID 0,1,10 and<br />

<strong>Intel</strong> ® RSTe RAID 0,1,5,10<br />

RKSATA4R5 Black 4 Port SATA with <strong>Intel</strong> ® ESRT2 RAID 0,1, 5, 10 and<br />

<strong>Intel</strong> ® RSTe RAID 0,1,5,10<br />

RKSATA8 Blue 8 Port SATA with <strong>Intel</strong> ® ESRT2 RAID 0,1, 10 and<br />

<strong>Intel</strong> ® RSTe RAID 0,1,5,10<br />

RKSATA8R5 White 8 Port SATA with <strong>Intel</strong> ® ESRT2 RAID 0,1, 5, 10 and<br />

<strong>Intel</strong> ® RSTe RAID 0,1,5,10<br />

RKSAS4 Green 4 Port SAS with <strong>Intel</strong> ® ESRT2 RAID 0,1, 10 and <strong>Intel</strong> ®<br />

RSTe RAID 0,1,10<br />

RKSAS4R5 Yellow 4 Port SAS with <strong>Intel</strong> ® ESRT2 RAID 0,1, 5, 10 and<br />

<strong>Intel</strong> ® RSTe RAID 0,1,10<br />

RKSAS8 Orange 8 Port SAS with <strong>Intel</strong> ® ESRT2 RAID 0,1, 10 and <strong>Intel</strong> ®<br />

RSTe RAID 0,1,10<br />

RKSAS8R5 Purple 8 Port SAS with <strong>Intel</strong> ® ESRT2 RAID 0,1, 5, 10 and<br />

<strong>Intel</strong> ® RSTe RAID 0,1,10<br />

Additional in<strong>for</strong>mation <strong>for</strong> the on-board RAID features and functionality can be found in the <strong>Intel</strong> ®<br />

RAID Software Users Guide (<strong>Intel</strong> Document Number D29305-015).<br />

4.4 PCI Subsystem<br />

The primary I/O buses <strong>for</strong> the <strong>Intel</strong> ® Server Board S2600CP are PCI Express* Gen3 with six<br />

independent PCI bus segments. The following tables list the characteristics of the PCI bus<br />

segments.<br />

Revision 0.8 <strong>Intel</strong> Confidential<br />

<strong>Intel</strong> order number G26942-003<br />

43