<strong>Intel</strong>® Server Board S2600CP Functional Architecture <strong>Intel</strong> ® Server Board S2600CP and Server System P4000CP TPS<br />
Error Severity System Action<br />
Processor <strong>Intel</strong> ® QuickPath Fatal The BIOS detects the QPI link frequencies and responds as follows:<br />
Interconnect link frequencies<br />
not identical<br />
Adjusts all QPI interconnect link frequencies to highest common<br />
frequency.<br />
No error is generated – this is not an error condition.<br />
Continues to boot the system successfully.<br />
28<br />
Processor microcode update<br />
missing<br />
Processor microcode update<br />
failed<br />
If the link frequencies <strong>for</strong> all QPI links cannot be adjusted to be the<br />
same, then this is an error, and the BIOS responds as follows:<br />
Logs the POST Error Code into the SEL.<br />
Alerts the BMC to set the System Status LED to steady Amber.<br />
Displays “0195: PProcessor <strong>Intel</strong>(R) QPI link frequencies unable to<br />
synchronize” message in the Error Manager.<br />
Does not disable the processor. Takes Fatal Error action (see above)<br />
and will not boot until the fault condition is remedied.<br />
Minor The BIOS detects the error condition and responds as follows:<br />
Logs the POST Error Code into the SEL.<br />
Displays “818x: Processor 0x microcode update not found” message<br />
in the Error Manager or on the screen.<br />
The system continues to boot in a degraded state, regardless of the<br />
setting of POST Error Pause in the Setup.<br />
Major The BIOS detects the error condition and responds as follows:<br />
Logs the POST Error Code into the SEL.<br />
Displays “816x: Processor 0x unable to apply microcode update”<br />
message in the Error Manager or on the screen.<br />
Takes Major Error action. The system may continue to boot in a<br />
degraded state, depending on the setting of POST Error Pause in<br />
Setup, or may halt with the POST Error Code in the Error Manager<br />
waiting <strong>for</strong> operator intervention.<br />
<strong>Intel</strong> Confidential Revision 0.8<br />
<strong>Intel</strong> order number G26942-003