Appendix D: Plat<strong>for</strong>m Specific BMC Appendix ® <strong>Intel</strong> ® Server Board S2600CP and Server System P4000CP TPS <strong>Intel</strong> ® Serv<br />
188<br />
<strong>Intel</strong> ® Server Chassis P4308 (UPM Base/BRP with fixed fan 4U)<br />
o 8-bay 3.5” HDD – FUP8X35HSBP<br />
<strong>Intel</strong> ® Server Chassis P4208 (UPM LX with redundant fan 4U)<br />
o 8-bay 2.5” HDD – FXX8X25HSBP<br />
<strong>Intel</strong> ® Server Chassis P4308 (UPM LX with redundant fan 4U)<br />
o 8-bay 3.5” HDD – FUP8X35HSBP<br />
<strong>Intel</strong> ® Server Chassis P4216 (UPM LX with redundant fan 4U)<br />
o 8-bay 2.5” HDD – FXX8X25HSBP<br />
Power unit support<br />
<strong>Intel</strong> ® Server Chassis P4208/P4308 (UPM Base with fixed fan 4U)<br />
PS Module<br />
Number<br />
550W Fixed<br />
Power Supply<br />
PMBus<br />
Not<br />
support<br />
<strong>Product</strong> Name(in<br />
product area of<br />
the FRU)<br />
PSU<br />
Redundant<br />
Cold<br />
Redundant<br />
<strong>Intel</strong> Confidential<br />
<strong>Intel</strong> order number G26942-003<br />
Fans in<br />
each PS<br />
No FRU Not support Not Support NA<br />
<strong>Intel</strong> ® Server Chassis P4208 (UPM BRP with fixed fan 4U)<br />
PS Module<br />
Number<br />
460W HS<br />
Power Supply<br />
750W HS<br />
Power Supply<br />
PMBus<br />
<strong>Product</strong> Name(in<br />
product area of<br />
the FRU)<br />
PSU<br />
Redundant<br />
Cold<br />
Redundant<br />
Fans in<br />
each PS<br />
Support DPS-460KB A Support Support 1 PS fan<br />
Support DPS-750XB A Support Support 1 PS fan<br />
<strong>Intel</strong> ® Server Chassis P4308 (UPM BRP with fixed fan 4U)<br />
PS Module<br />
Number<br />
750W HS<br />
Power Supply<br />
PMBus <strong>Product</strong> Name(in<br />
product area of<br />
the FRU)<br />
PSU<br />
Redundant<br />
Cold<br />
Redundant<br />
Fans in<br />
each PS<br />
Support DPS-750XB A Not support Not support 1 PS fan<br />
<strong>Intel</strong> ® Server Chassis P4208/P4308 (UPM LX with redundant fan 4U)<br />
PS Module<br />
Number<br />
750W HS<br />
Power Supply<br />
1200W HS<br />
Power Supply<br />
PMBus <strong>Product</strong> Name(in<br />
product area of the<br />
FRU)<br />
PSU<br />
Redundant<br />
Cold<br />
Redundant<br />
Fans in<br />
each PS<br />
Support DPS-750XB A Support Support 1 PS fan<br />
Support DPS-1200TB A Support Support 2PS fan<br />
<strong>Intel</strong> ® Server Chassis P4216 (UPM LX with redundant fan 4U)<br />
PS Module PMBus <strong>Product</strong> Name(in PSU Cold Fans in