Appendix D: Platform Specific BMC Appendix ® Intel ® Server Board S2600CP and Server System P4000CP TPS Intel ® Serv Chassis-specific sensors 186 Intel® Server Chassis P4208/P4308(UPM base/BRP with fixed fan 4U) P4208/P4308/P4216( UPM LX with redundant fan 4U) Hot-plug fan support Fan Tachometer sensors Fan Presence sensors Physical security (Chassis intrusion) Sensor Intel Confidential Intel order number G26942-003 FP interrupt (FP NMI Diag Int) System Fan 1(30h) NA Physical Scrty(04h) FP NMI Diag Int(05h) System Fan 2(31h) NA NA NA System Fan 1 (30h) Fan 1 Present (40h) Physical Scrty(04h) FP NMI Diag Int(05h) System Fan 2 (31h) Fan 2 Present (41h) NA NA System Fan 3 (32h) Fan 3 Present (42h) NA NA System Fan 4 (33h) Fan 4 Present (43h) NA NA System Fan 5 (34h) Fan 5 Present (44h) NA NA Supported on Intel ® Server Chassis P4208 (UPM LX with redundant fan 4U) Intel ® Server Chassis P4308 (UPM LX with redundant fan 4U) Intel ® Server Chassis P4216 (UPM LX with redundant fan 4U) Fan redundancy support Supported on Intel ® Server Chassis P4208 (UPM LX with redundant fan 4U) Intel ® Server Chassis P4308 (UPM LX with redundant fan 4U) Intel ® Server Chassis P4216 (UPM LX with redundant fan 4U) Fan domain definition Chassis P4208/ P4308 (UPM Base/BRP with fixed fan 4U) Fan Domain 0 1 Major Components Cooled (Temperature sensor number) Memory channels C & D(B1h) Memory channels E & F(B2h) BMC Temp(23h) Memory VR(25h) Baseboard NIC(2Fh) Server South Bridge(22h) Hot-swap backplane 1(29h) Hot-swap backplane 2(2Ah) P1 Therm Margin(74h) P2 Therm Margin(75h) Memory channels A & B(B0h) Memory channels C & D(B1h) Memory channels E & F(B2h) Memory channels G & H(B3h) BB P2 VR Temp(24h) Memory VR(25h) Hot-swap backplane 1(29h) Hot-swap backplane 2(2Ah) Fans (Sensor number) System Fan 1(30h) System Fan 2(31h)

Intel® Server System P4000CP TPS Appendix D: Platform Specific BMC Appendix Chassis P4208/ P4308/ P4216 (UPM LX with redundant fan 4U) HSC Availability Fan Domain 0 1 2 3 4 Major Components Cooled (Temperature sensor number) BMC Temp(23h) Memory VR(25h) Baseboard NIC(2Fh) Server South Bridge(22h) Hot-swap backplane 1(29h) Hot-swap backplane 2(2Ah) P1 Therm Margin(74h) P2 Therm Margin(75h) Memory channels C & D(B1h) Memory channels E & F(B2h) BMC Temp(23h) Memory VR(25h) Baseboard NIC(2Fh) Server South Bridge(22h) Hot-swap backplane 1(29h) Hot-swap backplane 2(2Ah) P1 Therm Margin(74h) P2 Therm Margin(75h) Memory channels A & B(B0h) Memory channels C & D(B1h) Memory channels E & F(B2h) Memory channels G & H(B3h) BB P2 VR Temp(24h) Memory VR(25h) Hot-swap backplane 1(29h) Hot-swap backplane 2(2Ah) P1 Therm Margin(74h) P2 Therm Margin(75h) Memory channels A & B(B0h) Memory channels C & D(B1h) Memory channels E & F(B2h) Memory channels G & H(B3h) BB P2 VR Temp(24h) Memory VR(25h) Hot-swap backplane 1(29h) Hot-swap backplane 2(2Ah) P2 Therm Margin(75h) Memory channels A & B(B0h) Memory channels G & H(B3h) BB P2 VR Temp(24h) Hot-swap backplane 1(29h) Hot-swap backplane 2(2Ah) Intel ® Server Chassis P4208 (UPM Base/BRP with fixed fan 4U) o 8-bay 2.5” HDD – FXX8X25HSBP Revision 0.8 Intel Confidential Intel order number G26942-003 Fans (Sensor number) System Fan 1 (30h) System Fan 2 (31h) System Fan 3 (32h) System Fan 4 (33h) System Fan 5 (34h) 187

<strong>Intel</strong>® Server System P4000CP TPS Appendix D: Plat<strong>for</strong>m Specific BMC Appendix<br />

Chassis<br />

P4208/<br />

P4308/<br />

P4216<br />

(UPM LX<br />

with<br />

redundant<br />

fan 4U)<br />

HSC Availability<br />

Fan Domain<br />

0<br />

1<br />

2<br />

3<br />

4<br />

Major Components Cooled<br />

(Temperature sensor number)<br />

BMC Temp(23h)<br />

Memory VR(25h)<br />

Baseboard NIC(2Fh)<br />

Server South Bridge(22h)<br />

Hot-swap backplane 1(29h)<br />

Hot-swap backplane 2(2Ah)<br />

P1 Therm Margin(74h)<br />

P2 Therm Margin(75h)<br />

Memory channels C & D(B1h)<br />

Memory channels E & F(B2h)<br />

BMC Temp(23h)<br />

Memory VR(25h)<br />

Baseboard NIC(2Fh)<br />

Server South Bridge(22h)<br />

Hot-swap backplane 1(29h)<br />

Hot-swap backplane 2(2Ah)<br />

P1 Therm Margin(74h)<br />

P2 Therm Margin(75h)<br />

Memory channels A & B(B0h)<br />

Memory channels C & D(B1h)<br />

Memory channels E & F(B2h)<br />

Memory channels G & H(B3h)<br />

BB P2 VR Temp(24h)<br />

Memory VR(25h)<br />

Hot-swap backplane 1(29h)<br />

Hot-swap backplane 2(2Ah)<br />

P1 Therm Margin(74h)<br />

P2 Therm Margin(75h)<br />

Memory channels A & B(B0h)<br />

Memory channels C & D(B1h)<br />

Memory channels E & F(B2h)<br />

Memory channels G & H(B3h)<br />

BB P2 VR Temp(24h)<br />

Memory VR(25h)<br />

Hot-swap backplane 1(29h)<br />

Hot-swap backplane 2(2Ah)<br />

P2 Therm Margin(75h)<br />

Memory channels A & B(B0h)<br />

Memory channels G & H(B3h)<br />

BB P2 VR Temp(24h)<br />

Hot-swap backplane 1(29h)<br />

Hot-swap backplane 2(2Ah)<br />

<strong>Intel</strong> ® Server Chassis P4208 (UPM Base/BRP with fixed fan 4U)<br />

o 8-bay 2.5” HDD – FXX8X25HSBP<br />

Revision 0.8 <strong>Intel</strong> Confidential<br />

<strong>Intel</strong> order number G26942-003<br />

Fans<br />

(Sensor number)<br />

System Fan 1 (30h)<br />

System Fan 2 (31h)<br />

System Fan 3 (32h)<br />

System Fan 4 (33h)<br />

System Fan 5 (34h)<br />

187