Technical Product Specification for Canoe Pass - Preminary - Intel
Technical Product Specification for Canoe Pass - Preminary - Intel
Technical Product Specification for Canoe Pass - Preminary - Intel
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Appendix D: Plat<strong>for</strong>m Specific BMC Appendix ® <strong>Intel</strong> ® Server Board S2600CP and Server System P4000CP TPS <strong>Intel</strong> ® Serv<br />
Chassis-specific sensors<br />
186<br />
<strong>Intel</strong>® Server<br />
Chassis<br />
P4208/P4308(UPM<br />
base/BRP with fixed<br />
fan 4U)<br />
P4208/P4308/P4216(<br />
UPM LX with<br />
redundant fan 4U)<br />
Hot-plug fan support<br />
Fan Tachometer<br />
sensors<br />
Fan Presence<br />
sensors<br />
Physical security<br />
(Chassis intrusion)<br />
Sensor<br />
<strong>Intel</strong> Confidential<br />
<strong>Intel</strong> order number G26942-003<br />
FP interrupt (FP NMI<br />
Diag Int)<br />
System Fan 1(30h) NA Physical Scrty(04h) FP NMI Diag Int(05h)<br />
System Fan 2(31h) NA NA NA<br />
System Fan 1 (30h) Fan 1 Present (40h) Physical Scrty(04h) FP NMI Diag Int(05h)<br />
System Fan 2 (31h) Fan 2 Present (41h) NA NA<br />
System Fan 3 (32h) Fan 3 Present (42h) NA NA<br />
System Fan 4 (33h) Fan 4 Present (43h) NA NA<br />
System Fan 5 (34h) Fan 5 Present (44h) NA NA<br />
Supported on<br />
<strong>Intel</strong> ® Server Chassis P4208 (UPM LX with redundant fan 4U)<br />
<strong>Intel</strong> ® Server Chassis P4308 (UPM LX with redundant fan 4U)<br />
<strong>Intel</strong> ® Server Chassis P4216 (UPM LX with redundant fan 4U)<br />
Fan redundancy support<br />
Supported on<br />
<strong>Intel</strong> ® Server Chassis P4208 (UPM LX with redundant fan 4U)<br />
<strong>Intel</strong> ® Server Chassis P4308 (UPM LX with redundant fan 4U)<br />
<strong>Intel</strong> ® Server Chassis P4216 (UPM LX with redundant fan 4U)<br />
Fan domain definition<br />
Chassis<br />
P4208/<br />
P4308<br />
(UPM<br />
Base/BRP<br />
with fixed<br />
fan 4U)<br />
Fan Domain<br />
0<br />
1<br />
Major Components Cooled<br />
(Temperature sensor number)<br />
Memory channels C & D(B1h)<br />
Memory channels E & F(B2h)<br />
BMC Temp(23h)<br />
Memory VR(25h)<br />
Baseboard NIC(2Fh)<br />
Server South Bridge(22h)<br />
Hot-swap backplane 1(29h)<br />
Hot-swap backplane 2(2Ah)<br />
P1 Therm Margin(74h)<br />
P2 Therm Margin(75h)<br />
Memory channels A & B(B0h)<br />
Memory channels C & D(B1h)<br />
Memory channels E & F(B2h)<br />
Memory channels G & H(B3h)<br />
BB P2 VR Temp(24h)<br />
Memory VR(25h)<br />
Hot-swap backplane 1(29h)<br />
Hot-swap backplane 2(2Ah)<br />
Fans<br />
(Sensor number)<br />
System Fan 1(30h)<br />
System Fan 2(31h)