03.07.2013 Views

Technical Product Specification for Canoe Pass - Preminary - Intel

Technical Product Specification for Canoe Pass - Preminary - Intel

Technical Product Specification for Canoe Pass - Preminary - Intel

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Appendix C: BMC Sensor Tables <strong>Intel</strong> ® Server Board S2600CP and Server System P4000CP TPS<br />

Full Sensor Name<br />

(Sensor name in SDR)<br />

Processor 4 DIMM<br />

Thermal Trip<br />

(P4 Mem Thrm Trip)<br />

Global Aggregate<br />

Temperature Margin 1<br />

(Agg Therm Mrgn 1)<br />

Global Aggregate<br />

Temperature Margin 2<br />

(Agg Therm Mrgn 2)<br />

Global Aggregate<br />

Temperature Margin 3<br />

(Agg Therm Mrgn 3)<br />

Global Aggregate<br />

Temperature Margin 4<br />

(Agg Therm Mrgn 4)<br />

Global Aggregate<br />

Temperature Margin 5<br />

(Agg Therm Mrgn 5)<br />

Global Aggregate<br />

Temperature Margin 6<br />

(Agg Therm Mrgn 6)<br />

Global Aggregate<br />

Temperature Margin 7<br />

(Agg Therm Mrgn 7)<br />

Global Aggregate<br />

Temperature Margin 8<br />

(Agg Therm Mrgn 8)<br />

Baseboard +12V<br />

(BB +12.0V)<br />

Baseboard +5V<br />

(BB +5.0V)<br />

Baseboard +3.3V<br />

(BB +3.3V)<br />

182<br />

Sensor<br />

#<br />

Plat<strong>for</strong>m<br />

Applicability<br />

C3h All<br />

C8h<br />

C9h<br />

CAh<br />

CBh<br />

CCh<br />

CDh<br />

CEh<br />

CFh<br />

Plat<strong>for</strong>m<br />

Specific<br />

Plat<strong>for</strong>m<br />

Specific<br />

Plat<strong>for</strong>m<br />

Specific<br />

Plat<strong>for</strong>m<br />

Specific<br />

Plat<strong>for</strong>m<br />

Specific<br />

Plat<strong>for</strong>m<br />

Specific<br />

Plat<strong>for</strong>m<br />

Specific<br />

Plat<strong>for</strong>m<br />

Specific<br />

D0h All<br />

D1h All<br />

D2h All<br />

Sensor Type Event/Readi<br />

ng Type<br />

Memory<br />

0Ch<br />

Temperature<br />

01h<br />

Temperature<br />

01h<br />

Temperature<br />

01h<br />

Temperature<br />

01h<br />

Temperature<br />

01h<br />

Temperature<br />

01h<br />

Temperature<br />

01h<br />

Temperature<br />

01h<br />

Voltage<br />

02h<br />

Voltage<br />

02h<br />

Voltage<br />

02h<br />

Digital<br />

Discrete<br />

03h<br />

Threshold<br />

01h<br />

Threshold<br />

01h<br />

Threshold<br />

01h<br />

Threshold<br />

01h<br />

Threshold<br />

01h<br />

Threshold<br />

01h<br />

Threshold<br />

01h<br />

Threshold<br />

01h<br />

Threshold<br />

01h<br />

Threshold<br />

01h<br />

Threshold<br />

01h<br />

Event Offset Triggers Contrib. To<br />

System Status<br />

0A- Critical<br />

overtemperature<br />

Fatal<br />

Assert/<br />

Deassert<br />

Readable<br />

Value /<br />

Offsets<br />

Event<br />

Data<br />

<strong>Intel</strong> Confidential Revision 0.8<br />

<strong>Intel</strong> order number G26942-003<br />

As<br />

and<br />

De<br />

Rearm Standby<br />

– Trig Offset M X<br />

- - - Analog R, T A –<br />

- - - Analog R, T A –<br />

- - - Analog R, T A –<br />

- - - Analog R, T A –<br />

- - - Analog R, T A –<br />

- - - Analog R, T A –<br />

- - - Analog R, T A –<br />

- - - Analog R, T A –<br />

[u,l] [c,nc]<br />

[u,l] [c,nc]<br />

[u,l] [c,nc]<br />

nc =<br />

Degraded<br />

c = Non-fatal<br />

nc =<br />

Degraded<br />

c = Non-fatal<br />

nc =<br />

Degraded<br />

c = Non-fatal<br />

As<br />

and<br />

De<br />

As<br />

and<br />

De<br />

As<br />

and<br />

De<br />

Analog R, T A –<br />

Analog R, T A –<br />

Analog R, T A –

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!