Appendix A: Integration and Usage Tips Intel ® Server Board S2600CP and Server System P4000CP TPS 164 Appendix A: Integration and Usage Tips When adding or removing components or peripherals from the server board, AC power must be removed. With AC power plugged into the server board, 5-V standby is still present even though the server board is powered off. This server board supports The Intel ® Xeon ® Processor E5-2600 product family with a Thermal Design Power (TDP) of up to and including 130 Watts. Previous generations of the Intel ® Xeon ® processors are not supported. Processors must be installed in order. CPU 1 must be populated for the server board to operate. On the back edge of the server board are eight diagnostic LEDs that display a sequence of amber POST codes during the boot process. If the server board hangs during POST, the LEDs display the last POST event run before the hang. This server board only supports registered DDR3 DIMMs (RDIMMs) and unbuffered DDR3 DIMMs (UDIMMs). Mixing of RDIMMs and UDIMMs is not supported. For the best performance, the number of DDR3 DIMMs installed should be balanced across both processor sockets and memory channels. For example, a two-DIMM configuration performs better than a one-DIMM configuration. In a two-DIMM configuration, DIMMs should be installed in DIMM sockets A1 and D1. The Intel ® Remote Management Module 4 (Intel ® RMM4) connector is not compatible with any previous versions of the Intel ® Remote Management Module (Product Order Code – AXXRMM, AXXRMM2, and AXXRMM3). Clear the CMOS with AC power cord plugged. Removing the AC power before performing the CMOS clear operation causes the system to automatically power up and immediately power down after the CMOS clear procedure is followed and AC power is re-applied. If this happens, remove the AC power cord, wait 30 seconds, and then reconnect the AC power cord. Power up the system and proceed to the BIOS Setup utility to reset the desired settings. Normal Integrated BMC functionality is disabled with the BMC Force Update jumper set to the “enabled” position (pins 2-3). The server should never be run with the BMC Force Update jumper set in this position and should only be used when the standard firmware update process fails. This jumper should remain in the default (disabled) position (pins 1- 2) when the server is running normally. When performing a normal BIOS update procedure, the BIOS recovery jumper must be set to its default position (pins 1-2). The recommended cable routings of the server board in the supported chassis are shown as below. Intel Confidential Revision 0.8 Intel order number G26942-003
Intel ® Server Board S2600CP and Server System P4000CP TPS Appendix A: Integration and Usage Tips Callout Description Callout Description A CPU1/CPU2 Power Cable B Server Board Main Power Cable C Fixed HDD Power Cable D ODD Power Cable E Front Panel Cable, USB Cable F G Fixed HDD Data Cable H System FAN 1 I System FAN 2 Revision 0.8 Intel Confidential Intel order number G26942-003 ODD Data Cable (Connect To White SATA 6G Connectors On Server Board) Figure 61. Intel ® Server Board S2600CP Cable Routing in Intel ® Server Chassis P4000M base SKU 165
- Page 129 and 130: Intel ® Server Board S2600CP and S
- Page 131 and 132: Intel ® Server Board S2600CP and S
- Page 133 and 134: Intel ® Server Board S2600CP and S
- Page 135 and 136: Intel ® Server Board S2600CP and S
- Page 137 and 138: Intel ® Server Board S2600CP and S
- Page 139 and 140: Intel ® Server Board S2600CP and S
- Page 141 and 142: Intel ® Server Board S2600CP and S
- Page 143 and 144: Intel ® Server Board S2600CP and S
- Page 145 and 146: Intel ® Server Board S2600CP and S
- Page 147 and 148: Intel ® Server Board S2600CP and S
- Page 149 and 150: Intel ® Server Board S2600CP and S
- Page 151 and 152: Intel ® Server Board S2600CP and S
- Page 153 and 154: Intel ® Server Board S2600CP and S
- Page 155 and 156: Intel ® Server Board S2600CP and S
- Page 157 and 158: Intel ® Server Board S2600CP and S
- Page 159 and 160: Intel ® Server Board S2600CP and S
- Page 161 and 162: Intel ® Server Board S2600CP and S
- Page 163 and 164: Intel ® Server Board S2600CP and S
- Page 165 and 166: Intel ® Server Board S2600CP and S
- Page 167 and 168: Intel ® Server Board S2600CP and S
- Page 169 and 170: Intel ® Server Board S2600CP and S
- Page 171 and 172: Intel ® Server Board S2600CP and S
- Page 173 and 174: Intel® Server System P4000CP TPS D
- Page 175 and 176: Intel ® Server Board S2600CP and S
- Page 177 and 178: Intel ® Server Board S2600CP and S
- Page 179: Intel ® Server Board S2600CP and S
- Page 183 and 184: Intel® Server System P4000CP TPS A
- Page 185 and 186: Intel ® Server Board S2600CP and S
- Page 187 and 188: Intel ® Server Board S2600CP and S
- Page 189 and 190: Intel ® Server Board S2600CP and S
- Page 191 and 192: Intel ® Server Board S2600CP and S
- Page 193 and 194: Intel ® Server Board S2600CP and S
- Page 195 and 196: Intel ® Server Board S2600CP and S
- Page 197 and 198: Intel ® Server Board S2600CP and S
- Page 199 and 200: Intel ® Server Board S2600CP and S
- Page 201 and 202: Intel® Server System P4000CP TPS A
- Page 203 and 204: Intel® Server System P4000CP TPS A
- Page 205 and 206: Intel® Server System P4000CP TPS A
- Page 207 and 208: Intel® Server System P4000CP TPS A
- Page 209 and 210: Intel® Server System P4000CP TPS A
- Page 211 and 212: Error! No text of specified style i
- Page 213 and 214: Error! No text of specified style i
- Page 215 and 216: Error! No text of specified style i
- Page 217 and 218: ® Intel ® Server Board S2600CP an
- Page 219 and 220: ® Intel ® Server Board S2600CP an
<strong>Intel</strong> ® Server Board S2600CP and Server System P4000CP TPS Appendix A: Integration and Usage Tips<br />
Callout Description Callout Description<br />
A CPU1/CPU2 Power Cable B Server Board Main Power Cable<br />
C Fixed HDD Power Cable D ODD Power Cable<br />
E Front Panel Cable, USB Cable F<br />
G Fixed HDD Data Cable H System FAN 1<br />
I System FAN 2<br />
Revision 0.8 <strong>Intel</strong> Confidential<br />
<strong>Intel</strong> order number G26942-003<br />
ODD Data Cable (Connect To White SATA<br />
6G Connectors On Server Board)<br />
Figure 61. <strong>Intel</strong> ® Server Board S2600CP Cable Routing in <strong>Intel</strong> ® Server Chassis P4000M base SKU<br />
165