03.07.2013 Views

Technical Product Specification for Canoe Pass - Preminary - Intel

Technical Product Specification for Canoe Pass - Preminary - Intel

Technical Product Specification for Canoe Pass - Preminary - Intel

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Intel</strong> ® Server Board S2600CP and Server System P4000CP TPS <strong>Intel</strong> ® Light Guided Diagnostics<br />

9.4.2 System Status LED<br />

The bi-color (green/amber) System Status LED operates as follows:<br />

Table 45. System Status LED<br />

Color State Criticality Description<br />

Green Solid on Ok Indicates that the System Status is ‘Healthy’. The system is not<br />

exhibiting any errors. AC power is present and BMC has booted and<br />

manageability functionality is up and running.<br />

Green ~1 Hz blink Degraded System degraded:<br />

1. Redundancy loss such as power-supply or fan. Applies only if the<br />

associated plat<strong>for</strong>m sub-system has redundancy capabilities.<br />

2. Fan warning or failure when the number of fully operational fans is<br />

more than minimum number needed to cool the system.<br />

3. Non-critical threshold crossed – Temperature (including HSBP<br />

temp), voltage, input power to power supply, output current <strong>for</strong> main<br />

power rail from power supply and Processor Thermal Control<br />

(Therm Ctrl) sensors.<br />

4. Power supply predictive failure occurred while redundant power<br />

supply configuration was present.<br />

5. Unable to use all of the installed memory (more than 1 DIMM<br />

installed).<br />

6. Correctable Errors over a threshold and migrating to a spare DIMM<br />

(memory sparing). This indicates that the user no longer has spared<br />

DIMMs indicating a redundancy lost condition. Corresponding DIMM<br />

LED lit.<br />

7. In mirrored configuration, when memory mirroring takes place and<br />

system loses memory redundancy.<br />

8. Battery failure.<br />

Amber ~1 Hz blink Non-critical<br />

9. BMC executing in uBoot. (Indicated by Chassis ID blinking at<br />

Blinking at 3Hz). System in degraded state (no manageability). BMC<br />

uBoot is running but has not transferred control to BMC Linux.<br />

Server will be in this state 6-8 seconds after BMC reset while it pulls<br />

the Linux image into flash<br />

10. BMC booting Linux. (Indicated by Chassis ID solid ON). System in<br />

degraded state (no manageability). Control has been passed from<br />

BMC uBoot to BMC Linux itself. It will be in this state <strong>for</strong> ~10-~20<br />

seconds.<br />

11. BMC Watchdog has reset the BMC.<br />

12. Power Unit sensor offset <strong>for</strong> configuration error is asserted.<br />

13. HDD HSC is off-line or degraded.<br />

Non-fatal alarm – system is likely to fail:<br />

1. Critical threshold crossed – Voltage, temperature (including HSBP<br />

temp), input power to power supply, output current <strong>for</strong> main power<br />

rail from power supply and PROCHOT (Therm Ctrl) sensors.<br />

2. VRD Hot asserted.<br />

3. Minimum number of fans to cool the system not present or failed<br />

4. Hard drive fault<br />

5. Power Unit Redundancy sensor – Insufficient resources offset<br />

(indicates not enough power supplies present)<br />

6. In non-sparing and non-mirroring mode if the threshold of<br />

correctable errors is crossed within the window<br />

Revision 0.8 <strong>Intel</strong> Confidential<br />

<strong>Intel</strong> order number G26942-003<br />

85

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!