Step Command Purpose<br />

Fine-Tuning E&M Voice Ports<br />

11 timing digit milliseconds If the <strong>voice</strong>-<strong>port</strong> dial type is DTMF, configure the<br />

DTMF digit signal duration. The range of the DTMF<br />

digit signal duration is from 50 to 100 milliseconds.<br />

The <strong>de</strong>fault is 100.<br />

12 timing inter-digit milliseconds If the <strong>voice</strong>-<strong>port</strong> dial type is DTMF, configure the<br />

DTMF inter-digit signal duration. The range of the<br />

DTMF inter-digit signal duration is from 50 to 500<br />

milliseconds. The <strong>de</strong>fault is 100.<br />

13 timing pulse-digit milliseconds If the <strong>voice</strong>-<strong>port</strong> dial type is pulse, configure the<br />

pulse digit signal duration. The range of the pulse<br />

digit signal duration is from10 to 20 milliseconds.<br />

The <strong>de</strong>fault is 20.<br />

14 timing pulse-inter-digit milliseconds If the <strong>voice</strong>-<strong>port</strong> dial type is pulse, configure the<br />

pulse inter-digit signal duration. The range of the<br />

pulse inter-digit signal duration is from 100 to 1000<br />

milliseconds. The <strong>de</strong>fault is 500.<br />

15 timing wink-duration milliseconds Configure the timing wink-duration value. This<br />

value sets the wink signal duration for a wink-start<br />

signal. This value applies only if the signal<br />

command is set to “wink-start.” The range is from<br />

100 to 400 milliseconds and the <strong>de</strong>fault is 200.<br />

16 timing wink-wait milliseconds Configure the timing wink-wait value. This value<br />

sets the wink wait duration for a wink-start signal.<br />

This value applies only if the signal command is set<br />

to “wink-start.” The range is from 100 to 5000<br />

milliseconds and the <strong>de</strong>fault is 200.<br />

17 timing clear-wait milliseconds Configure the timing clear-wait value. This value<br />

sets the amount of time between the inactive seizure<br />

signal and the call being cleared. The range is from<br />

100 to 2000 milliseconds and the <strong>de</strong>fault is 400.<br />

18 timing <strong>de</strong>lay-duration milliseconds Configure the timing <strong>de</strong>lay-duration value. This<br />

value sets the <strong>de</strong>lay signal duration for <strong>de</strong>lay dial<br />

signaling. This value applies only if the signal<br />

command is set to “<strong>de</strong>lay-dial.” The range is from<br />

100 to 5000 milliseonds and the <strong>de</strong>fault is 140.<br />

19 timing <strong>de</strong>lay-start milliseconds Configure the timing <strong>de</strong>lay-start value. This value<br />

sets the <strong>de</strong>lay interval between the generation of the<br />

<strong>de</strong>lay-start signal from incoming <strong>de</strong>tection seizure.<br />

This value applies only if the signal command is set<br />

to “<strong>de</strong>lay-dial.” The range is from 100 to 290<br />

milliseconds and the <strong>de</strong>fault is 150.<br />

20 timing percentbreak percent Configure the timing percent-break value. This value<br />

sets the percentage of the break period for a dialing<br />

pulse. The <strong>de</strong>fault is 50 percent.<br />

Note After you change any <strong>voice</strong>-<strong>port</strong> command, it is a good i<strong>de</strong>a to cycle the <strong>port</strong> by using the<br />

shutdown and no shutdown commands.<br />