MAINTENANCE AND SERVICE G-<strong>13.mft</strong> totalizer<br />
Troubleshooting<br />
Problem<br />
Totalizer<br />
does not<br />
accept coin<br />
Totalizer<br />
accepts<br />
coin but no<br />
credit is<br />
given<br />
Malfunctions can occur in all electronic devices. These do not always have<br />
to be faults in the device. In many cases the reason is improper connections<br />
or incorrect settings. Therefore: please first of all check, whether the<br />
malfunction can simply be remedied using the following table:<br />
Possible causes<br />
No power supply<br />
Return lever/button<br />
pressed/got stuck<br />
Coin runway dirty<br />
Coin inhibited<br />
Price/time DIL<br />
switches set to OFF<br />
Coin does not exit the<br />
device<br />
Remedy, hints<br />
• Connect ribbon cable to totalizer and<br />
machine correctly<br />
• Supply vending maching with voltage<br />
Make sure, that return lever/button is not<br />
inadvertently pressed<br />
Open flight deck and clean coin runway<br />
(see section "Cleaning totalizer" in this<br />
chapter)<br />
• Make sure that (common) inhibit line<br />
(pin 2/pin 6) is not activated by machine<br />
(see section "Interfaces" in Chap. 8<br />
"Technical data")<br />
• Make sure that the coin is not inhibited<br />
using the DIL switches on the rear of the<br />
device or not only the narrow coin channel<br />
is enabled and the normal one is inhibited<br />
(see section "Inhibit coin types" in Chap. 4<br />
"Function and operation")<br />
Set price(s)/timer time (see section "Set the<br />
price(s)/timer time" in Chap. 4 "Function<br />
and operation")<br />
Make sure that the coin outlet is not<br />
jammed by foreign objects or devices<br />
connected to the bottom of the totalizer<br />
56 National Rejectors, Inc. GmbH, Buxtehude