MAINTENANCE AND SERVICE G-<strong>13.mft</strong> totalizer<br />

Troubleshooting<br />

Problem<br />

Totalizer<br />

does not<br />

accept coin<br />

Totalizer<br />

accepts<br />

coin but no<br />

credit is<br />

given<br />

Malfunctions can occur in all electronic devices. These do not always have<br />

to be faults in the device. In many cases the reason is improper connections<br />

or incorrect settings. Therefore: please first of all check, whether the<br />

malfunction can simply be remedied using the following table:<br />

Possible causes<br />

No power supply<br />

Return lever/button<br />

pressed/got stuck<br />

Coin runway dirty<br />

Coin inhibited<br />

Price/time DIL<br />

switches set to OFF<br />

Coin does not exit the<br />

device<br />

Remedy, hints<br />

• Connect ribbon cable to totalizer and<br />

machine correctly<br />

• Supply vending maching with voltage<br />

Make sure, that return lever/button is not<br />

inadvertently pressed<br />

Open flight deck and clean coin runway<br />

(see section "Cleaning totalizer" in this<br />

chapter)<br />

• Make sure that (common) inhibit line<br />

(pin 2/pin 6) is not activated by machine<br />

(see section "Interfaces" in Chap. 8<br />

"Technical data")<br />

• Make sure that the coin is not inhibited<br />

using the DIL switches on the rear of the<br />

device or not only the narrow coin channel<br />

is enabled and the normal one is inhibited<br />

(see section "Inhibit coin types" in Chap. 4<br />

"Function and operation")<br />

Set price(s)/timer time (see section "Set the<br />

price(s)/timer time" in Chap. 4 "Function<br />

and operation")<br />

Make sure that the coin outlet is not<br />

jammed by foreign objects or devices<br />

connected to the bottom of the totalizer<br />

56 National Rejectors, Inc. GmbH, Buxtehude