STARTING UP G-<strong>13.mft</strong> totalizer<br />
... on the front entry model<br />
1 If necessary, fasten holding plate 1 with two screws 2 and 3 to<br />
sorting device 4 (see Fig. 5b).<br />
2 Remove screw 5 from totalizer.<br />
3 Use the holding plate to insert the sorting device from the right-hand<br />
side onto the totalizer.<br />
4 Fasten the sorting device with screw 5 to the totalizer.<br />
5 Use the 3-pole sorting plug 6 on the PCB 7 and on the rear of the<br />
totalizer to connect the sorting device to the G-<strong>13.mft</strong> with the help of<br />
the appropriate sorting cable.<br />
6 Use the 10-pole connecting plug 8 on the PCB 7 and on the rear of<br />
the totalizer to connect the sorting device to the G-<strong>13.mft</strong> for the<br />
power supply of the sorting magnets with the help of the appropriate<br />
connecting cable.<br />
7 Use the 10-pole connection plug 8 on the PCB 7 and the same<br />
connecting cable to connect the totalizer to the machine (see also<br />
section "Installing totalizer in the machine " in this chapter).<br />
7<br />
6<br />
8<br />
54 National Rejectors, Inc. GmbH, Buxtehude<br />