G-13.mft parallel - NRI
G-13.mft parallel - NRI
G-13.mft parallel - NRI
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
STARTING UP G-<strong>13.mft</strong> totalizer<br />
Installing sorting device ...<br />
If you want to operate the G-<strong>13.mft</strong> with the <strong>NRI</strong> 3-fold sorting device, you<br />
must use a special bracket to install the <strong>NRI</strong> sorting device on the top entry<br />
model or on the front entry model:<br />
... on the top entry model<br />
1 If necessary, fasten chute extension 1 with screw 2 to sorting<br />
device 3 (see Fig. 5a).<br />
2 Fasten mounting frame 4 by means of screws 5 and 6 to the rear of<br />
the sorting device.<br />
3 Hang the totalizer by its mounting studs 7 in the mounting frame.<br />
4 Use the 3-pole sorting plug 8 on the PCB 9 and on the rear of the<br />
totalizer to connect the sorting device to the G-<strong>13.mft</strong> with the help of<br />
the appropriate sorting cable.<br />
5 Use the 10-pole connecting plug 10 on the PCB 9 and on the rear of<br />
the totalizer to connect the sorting device to the G-<strong>13.mft</strong> for the<br />
power supply of the sorting magnets with the help of the appropriate<br />
connecting cable.<br />
6 Use the 10-pole connection plug 10 on the PCB 9 and the same<br />
connecting cable to connect the totalizer to the machine (see also<br />
section "Installing totalizer in the machine" in this chapter).<br />
52 National Rejectors, Inc. GmbH, Buxtehude