G-<strong>13.mft</strong> totalizer FUNCTION AND OPERATION<br />

Options<br />

The G-<strong>13.mft</strong> totalizer can optionally be equipped for the following applications<br />

at the manufacturer.<br />

Battery or low-power applications<br />

If the G-<strong>13.mft</strong> is to be used independent of the mains in battery-operated<br />

machines, it can optionally be fitted with a wake-up sensor (not available for<br />

retrofitting).<br />

The wake-up sensor monitors the insertion area of the totalizer. The first<br />

coin inserted wakes up the totalizer. The coin is measured and accepted or<br />

rejected, a possible credit or timer time is processed. If the vending process<br />

is completed, the totalizer returns to sleep mode after 3.5 sec. A credit which<br />

is not honoured is stored for 5 min. after the last coin has been inserted<br />

(battery protection) before the totalizer returns to sleep mode. The current<br />

consumption in sleep mode is less than 15 µA until the unit is woken up again<br />

by insertion of a coin. (See section "Interfaces" in Chap. 8 "Technical Data")<br />

Credit dwell time: Possible setting: 1–25 min., standard setting: 5 min.<br />

If the device is in teach mode, it remains awake until the coin/token is taught,<br />

i.e. the teach mode is switched off again.<br />

At the factory the totalizer can optionally be set, so that it transmits a wakeup<br />

signal to the machine via the return signal line, as soon as it is woken up<br />

by insertion of a coin (not ECV totalizer).<br />

High-voltage applications up to 42 V<br />

If the totalizer is to be supplied with more than 10–16 V, at the factory it can<br />

be equipped with a switching power supply which makes a supply voltage<br />

of up to 42 V possible (not available for retrofitting).<br />