01.07.2013 Views

G-13.mft parallel - NRI

G-13.mft parallel - NRI

G-13.mft parallel - NRI

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

FUNCTION AND OPERATION G-<strong>13.mft</strong> totalizer<br />

Select memory block<br />

(only for double block data-management)<br />

If the 32 coin channels, divided in 16 coin channels each, are data-managed<br />

in two (memory) blocks (B-0 and B-1, see label), these (memory) blocks are<br />

programmed separately from one another by the manufacturer on a customerspecific<br />

basis. The data of the two blocks 0 and 1 differ when they are being<br />

used in the device, e.g. by the acceptance of different currencies, such as<br />

national currency and Euro. Only one block can be active at a time and be<br />

used for the coin measurement and for further coin processing.<br />

If the totalizer is to access the other memory block and, e.g., accept Euro<br />

coins instead of national currency coins, the correct block can be selected<br />

using the upper switching block.<br />

S1 S1<br />

Memory block 0 selected Memory block 1 selected<br />

Set DIL switch S1.10 of the upper switching block downward to OFF to<br />

select memory block 0 and upward to ON to select memory block 1.<br />

Inhibit coin types<br />

If coins are no longer to be accepted for payment at the machine, you can<br />

either inhibit the entire coin acceptance using the machine control system<br />

(common inhibit) or inhibit individual types using the switching blocks on the<br />

totalizer.<br />

External common inhibit<br />

The machine can inhibit coin acceptance via the common inhibit signal line.<br />

The totalizer no longer accepts coins (see section "Interfaces (pin assignment<br />

and connection diagrams)" in Chap. 8 "Technical data").<br />

Internal inhibit of single coin types/coin groups ...<br />

Using the DIL switches on the totalizer, you can inhibit individual coin types<br />

or also groups of coins on site.<br />

Depending on whether the 32 coin channels are being data-managed in one<br />

or, when divided in 16 coin channels each, in two memory blocks (B-0 and<br />

B-1, see label), the coin types are inhibited differently.<br />

Alternatively: deactivate individual coin types on a long-term basis<br />

38 National Rejectors, Inc. GmbH, Buxtehude